-
We present results from the Hitomi X-ray observation of a young
composite-type supernova remnant (SNR) G21.5$-$0.9, whose emission is dominated
by the pulsar wind nebula (PWN) contribution. The X-ray spectra in the 0.8-80
keV range obtained with the Soft X-ray Spectrometer (SXS), Soft X-ray Imager
(SXI) and Hard X-ray Imager (HXI) show a significant break in the continuum as
previously found with the NuSTAR observation. After taking into account all
known emissions from the SNR other than the PWN itself, we find that the Hitomi
spectra can be fitted with a broken power law with photon indices of
$\Gamma_1=1.74\pm0.02$ and $\Gamma_2=2.14\pm0.01$ below and above the break at
$7.1\pm0.3$ keV, which is significantly lower than the NuSTAR result ($\sim9.0$
keV). The spectral break cannot be reproduced by time-dependent particle
injection one-zone spectral energy distribution models, which strongly
indicates that a more complex emission model is needed, as suggested by recent
theoretical models. We also search for narrow emission or absorption lines with
the SXS, and perform a timing analysis of PSR J1833$-$1034 with the HXI and
SGD. No significant pulsation is found from the pulsar. However, unexpectedly,
narrow absorption line features are detected in the SXS data at 4.2345 keV and
9.296 keV with a significance of 3.65 $\sigma$. While the origin of these
features is not understood, their mere detection opens up a new field of
research and was only possible with the high resolution, sensitivity and
ability to measure extended sources provided by an X-ray microcalorimeter.
-
The Soft X-ray Imager (SXI) is an imaging spectrometer using charge-coupled
devices (CCDs) aboard the Hitomi X-ray observatory. The SXI sensor has four
CCDs with an imaging area size of $31~{\rm mm} \times 31~{\rm mm}$ arranged in
a $2 \times 2$ array. Combined with the X-ray mirror, the Soft X-ray Telescope,
the SXI detects X-rays between $0.4~{\rm keV}$ and $12~{\rm keV}$ and covers a
$38^{\prime} \times 38^{\prime}$ field-of-view. The CCDs are P-channel
fully-depleted, back-illumination type with a depletion layer thickness of
$200~\mu{\rm m}$. Low operation temperature down to $-120~^\circ{\rm C}$ as
well as charge injection is employed to reduce the charge transfer inefficiency
of the CCDs. The functionality and performance of the SXI are verified in
on-ground tests. The energy resolution measured is $161$-$170~{\rm eV}$ in full
width at half maximum for $5.9~{\rm keV}$ X-rays. In the tests, we found that
the CTI of some regions are significantly higher. A method is developed to
properly treat the position-dependent CTI. Another problem we found is pinholes
in the Al coating on the incident surface of the CCDs for optical light
blocking. The Al thickness of the contamination blocking filter is increased in
order to sufficiently block optical light.
-
The present paper investigates the temperature structure of the X-ray
emitting plasma in the core of the Perseus cluster using the 1.8--20.0 keV data
obtained with the Soft X-ray Spectrometer (SXS) onboard the Hitomi Observatory.
A series of four observations were carried out, with a total effective exposure
time of 338 ks and covering a central region $\sim7'$ in diameter. The SXS was
operated with an energy resolution of $\sim$5 eV (full width at half maximum)
at 5.9 keV. Not only fine structures of K-shell lines in He-like ions but also
transitions from higher principal quantum numbers are clearly resolved from Si
through Fe. This enables us to perform temperature diagnostics using the line
ratios of Si, S, Ar, Ca, and Fe, and to provide the first direct measurement of
the excitation temperature and ionization temperature in the Perseus cluster.
The observed spectrum is roughly reproduced by a single temperature thermal
plasma model in collisional ionization equilibrium, but detailed line ratio
diagnostics reveal slight deviations from this approximation. In particular,
the data exhibit an apparent trend of increasing ionization temperature with
increasing atomic mass, as well as small differences between the ionization and
excitation temperatures for Fe, the only element for which both temperatures
can be measured. The best-fit two-temperature models suggest a combination of 3
and 5 keV gas, which is consistent with the idea that the observed small
deviations from a single temperature approximation are due to the effects of
projection of the known radial temperature gradient in the cluster core along
the line of sight. Comparison with the Chandra/ACIS and the XMM-Newton/RGS
results on the other hand suggests that additional lower-temperature components
are present in the ICM but not detectable by Hitomi SXS given its 1.8--20 keV
energy band.
-
The Hitomi SXS spectrum of the Perseus cluster, with $\sim$5 eV resolution in
the 2-9 keV band, offers an unprecedented benchmark of the atomic modeling and
database for hot collisional plasmas. It reveals both successes and challenges
of the current atomic codes. The latest versions of AtomDB/APEC (3.0.8), SPEX
(3.03.00), and CHIANTI (8.0) all provide reasonable fits to the broad-band
spectrum, and are in close agreement on best-fit temperature, emission measure,
and abundances of a few elements such as Ni. For the Fe abundance, the APEC and
SPEX measurements differ by 16%, which is 17 times higher than the statistical
uncertainty. This is mostly attributed to the differences in adopted
collisional excitation and dielectronic recombination rates of the strongest
emission lines. We further investigate and compare the sensitivity of the
derived physical parameters to the astrophysical source modeling and
instrumental effects. The Hitomi results show that an accurate atomic code is
as important as the astrophysical modeling and instrumental calibration
aspects. Substantial updates of atomic databases and targeted laboratory
measurements are needed to get the current codes ready for the data from the
next Hitomi-level mission.
-
We present Hitomi observations of N132D, a young, X-ray bright, O-rich
core-collapse supernova remnant in the Large Magellanic Cloud (LMC). Despite a
very short observation of only 3.7 ks, the Soft X-ray Spectrometer (SXS) easily
detects the line complexes of highly ionized S K and Fe K with 16-17 counts in
each. The Fe feature is measured for the first time at high spectral
resolution. Based on the plausible assumption that the Fe K emission is
dominated by He-like ions, we find that the material responsible for this Fe
emission is highly redshifted at ~800 km/s compared to the local LMC
interstellar medium (ISM), with a 90% credible interval of 50-1500 km/s if a
weakly informative prior is placed on possible line broadening. This indicates
(1) that the Fe emission arises from the supernova ejecta, and (2) that these
ejecta are highly asymmetric, since no blue-shifted component is found. The S K
velocity is consistent with the local LMC ISM, and is likely from swept-up ISM
material. These results are consistent with spatial mapping that shows the
He-like Fe concentrated in the interior of the remnant and the S tracing the
outer shell. The results also show that even with a very small number of
counts, direct velocity measurements from Doppler-shifted lines detected in
extended objects like supernova remnants are now possible. Thanks to the very
low SXS background of ~1 event per spectral resolution element per 100 ks, such
results are obtainable during short pointed or slew observations with similar
instruments. This highlights the power of high-spectral-resolution imaging
observations, and demonstrates the new window that has been opened with Hitomi
and will be greatly widened with future missions such as the X-ray Astronomy
Recovery Mission (XARM) and Athena.
-
We report a Hitomi observation of IGR J16318-4848, a high-mass X-ray binary
system with an extremely strong absorption of N_H~10^{24} cm^{-2}. Previous
X-ray studies revealed that its spectrum is dominated by strong fluorescence
lines of Fe as well as continuum emission. For physical and geometrical insight
into the nature of the reprocessing material, we utilize the high spectroscopic
resolving power of the X-ray microcalorimeter (the soft X-ray spectrometer;
SXS) and the wide-band sensitivity by the soft and hard X-ray imager (SXI and
HXI) aboard Hitomi. Even though photon counts are limited due to unintended
off-axis pointing, the SXS spectrum resolves Fe K{\alpha_1} and K{\alpha_2}
lines and puts strong constraints on the line centroid and width. The line
width corresponds to the velocity of 160^{+300}_{-70} km s^{-1}. This
represents the most accurate, and smallest, width measurement of this line made
so far from any X-ray binary, much less than the Doppler broadening and shift
expected from speeds which are characteristic of similar systems. Combined with
the K-shell edge energy measured by the SXI and HXI spectra, the ionization
state of Fe is estimated to be in the range of Fe I--IV. Considering the
estimated ionization parameter and the distance between the X-ray source and
the absorber, the density and thickness of the materials are estimated. The
extraordinarily strong absorption and the absence of a Compton shoulder
component is confirmed. These characteristics suggest reprocessing materials
which are distributed in a narrow solid angle or scattering primarily with warm
free electrons or neutral hydrogen.
-
The origin of the narrow Fe-K{\alpha} fluorescence line at 6.4 keV from
active galactic nuclei has long been under debate; some of the possible sites
are the outer accretion disk, the broad line region, a molecular torus, or
interstellar/intracluster media. In February-March 2016, we performed the first
X-ray microcalorimeter spectroscopy with the Soft X-ray Spectrometer (SXS)
onboard the Hitomi satellite of the Fanaroff-Riley type I radio galaxy NGC 1275
at the center of the Perseus cluster of galaxies. With the high energy
resolution of ~5 eV at 6 keV achieved by Hitomi/SXS, we detected the
Fe-K{\alpha} line with ~5.4 {\sigma} significance. The velocity width is
constrained to be 500-1600 km s$^{-1}$ (FWHM for Gaussian models) at 90%
confidence. The SXS also constrains the continuum level from the NGC 1275
nucleus up to ~20 keV, giving an equivalent width ~20 eV of the 6.4 keV line.
Because the velocity width is narrower than that of broad H{\alpha} line of
~2750 km s$^{-1}$, we can exclude a large contribution to the line flux from
the accretion disk and the broad line region. Furthermore, we performed pixel
map analyses on the Hitomi/SXS data and image analyses on the Chandra archival
data, and revealed that the Fe-K{\alpha} line comes from a region within ~1.6
kpc from the NGC 1275 core, where an active galactic nucleus emission
dominates, rather than that from intracluster media. Therefore, we suggest that
the source of the Fe-K{\alpha} line from NGC 1275 is likely a low-covering
fraction molecular torus or a rotating molecular disk which probably extends
from a pc to hundreds pc scale in the active galactic nucleus system.
-
Extending the earlier measurements reported in Hitomi collaboration (2016,
Nature, 535, 117), we examine the atmospheric gas motions within the central
100~kpc of the Perseus cluster using observations obtained with the Hitomi
satellite. After correcting for the point spread function of the telescope and
using optically thin emission lines, we find that the line-of-sight velocity
dispersion of the hot gas is remarkably low and mostly uniform. The velocity
dispersion reaches maxima of approximately 200~km~s$^{-1}$ toward the central
active galactic nucleus (AGN) and toward the AGN inflated north-western `ghost'
bubble. Elsewhere within the observed region, the velocity dispersion appears
constant around 100~km~s$^{-1}$. We also detect a velocity gradient with a
100~km~s$^{-1}$ amplitude across the cluster core, consistent with large-scale
sloshing of the core gas. If the observed gas motions are isotropic, the
kinetic pressure support is less than 10\% of the thermal pressure support in
the cluster core. The well-resolved optically thin emission lines have Gaussian
shapes, indicating that the turbulent driving scale is likely below 100~kpc,
which is consistent with the size of the AGN jet inflated bubbles. We also
report the first measurement of the ion temperature in the intracluster medium,
which we find to be consistent with the electron temperature. In addition, we
present a new measurement of the redshift to the brightest cluster galaxy
NGC~1275.
-
High-resolution X-ray spectroscopy with Hitomi was expected to resolve the
origin of the faint unidentified E=3.5 keV emission line reported in several
low-resolution studies of various massive systems, such as galaxies and
clusters, including the Perseus cluster. We have analyzed the Hitomi
first-light observation of the Perseus cluster. The emission line expected for
Perseus based on the XMM-Newton signal from the large cluster sample under the
dark matter decay scenario is too faint to be detectable in the Hitomi data.
However, the previously reported 3.5 keV flux from Perseus was anomalously high
compared to the sample-based prediction. We find no unidentified line at the
reported high flux level. Taking into account the XMM measurement uncertainties
for this region, the inconsistency with Hitomi is at a 99% significance for a
broad dark-matter line and at 99.7% for a narrow line from the gas. We do not
find anomalously high fluxes of the nearby faint K line or the Ar satellite
line that were proposed as explanations for the earlier 3.5 keV detections. We
do find a hint of a broad excess near the energies of high-n transitions of
Sxvi (E=3.44 keV rest-frame) -- a possible signature of charge exchange in the
molecular nebula and another proposed explanation for the unidentified line.
While its energy is consistent with XMM pn detections, it is unlikely to
explain the MOS signal. A confirmation of this interesting feature has to wait
for a more sensitive observation with a future calorimeter experiment.
-
GRS 1747$-$312 is a neutron star Low-Mass X-ray Binary in the globular
cluster Terzan 6, located at a distance of 9.5 kpc from the Earth. During its
outbursts, periodic eclipses were known to occur. Observations for the
outbursts were performed with Chandra in 2004 and Swift in 2013. XMM-Newton
observed its quiescent state in 2004. In addition, when Suzaku observed it in
2009 as a part of Galactic center mapping observations, GRS 1747$-$312 was
found to be in a low luminosity state with $L_{\rm x} \sim 1.2 \times 10^{35}$
erg s$^{-1}$. All of the observations except for XMM-Newton included the time
of the eclipses predicted. We analyzed archival data of these observations.
During the Chandra and Swift observations, we found clear flux decreases at the
expected time of the eclipses. During the Suzaku observation, however, there
were no clear signs for the predicted eclipses. The lapse of the predicted
eclipses during the Suzaku observation can be explained by a contaminant source
quite close to GRS 1747$-$312. When GRS 1747$-$312 is in the quiescent state,
we observe X-rays from the contaminant source rather than from GRS 1747$-$312.
However, we have no clear evidence for the contaminant source in our data. The
lapse might also be explained by thick material ($N_{\rm H} > 10^{24}$
cm$^{-2}$ ) between the neutron star and the companion star, though the origin
of the thick material is not clear.