• Login
    Sort by: Relevance Date Users's collections Twitter
    Group by: Day Week Month Year All time
Based on the idea and the provided source code of Andrej Karpathy (arxiv-sanity)
2:3 1:1 3:2
  • SENSEI: First Direct-Detection Constraints on sub-GeV Dark Matter from a Surface Run (1804.00088)

    The SENSEI Collaboration: Michael Crisler, Rouven Essig, Juan Estrada, Guillermo Fernandez, Javier Tiffenberg, Miguel Sofo Haro, Tomer Volansky, Tien-Tien Yu
    March 30, 2018 hep-ph, hep-ex, astro-ph.CO
    The Sub-Electron-Noise Skipper CCD Experimental Instrument (SENSEI) uses the recently developed Skipper-CCD technology to search for electron recoils from the interaction of sub-GeV dark matter particles with electrons in silicon. We report first results from a prototype SENSEI detector, which collected 0.019 gram-days of commissioning data above ground at Fermi National Accelerator Laboratory. These commissioning data are sufficient to set new direct-detection constraints for dark matter particles with masses between ~500 keV and 4 MeV. Moreover, since these data were taken on the surface, they disfavor previously allowed strongly interacting dark matter particles with masses between ~500 keV and a few hundred MeV. We discuss the implications of these data for several dark matter candidates, including one model proposed to explain the anomalously large 21-cm signal observed by the EDGES Collaboration. SENSEI is the first experiment dedicated to the search for electron recoils from dark matter, and these results demonstrate the power of the Skipper-CCD technology for dark matter searches.
  • Development of a novel neutron detection technique by using a boron layer coating a Charge Coupled Device (1408.3263)

    Juan Jerónimo Blostein, Juan Estrada, Aureliano Tartaglione, Miguel Sofo Haro, Guillermo Fernández Moroni, Gustavo Cancelo
    Aug. 14, 2014 physics.ins-det
    This article describes the design features and the first test measurements obtained during the installation of a novel high resolution 2D neutron detection technique. The technique proposed in this work consists of a boron layer (enriched in ${^{10}}$B) placed on a scientific Charge Coupled Device (CCD). After the nuclear reaction ${^{10}}$B(n,$\alpha$)${^{7}}$Li, the CCD detects the emitted charge particles thus obtaining information on the neutron absorption position. The above mentioned ionizing particles, with energies in the range 0.5-5.5 MeV, produce a plasma effect in the CCD which is recorded as a circular spot. This characteristic circular shape, as well as the relationship observed between the spot diameter and the charge collected, is used for the event recognition, allowing the discrimination of undesirable gamma events. We present the first results recently obtained with this technique, which has the potential to perform neutron tomography investigations with a spatial resolution better than that previously achieved. Numerical simulations indicate that the spatial resolution of this technique will be about 15 $\mu$m, and the intrinsic detection efficiency for thermal neutrons will be about 3 %. We compare the proposed technique with other neutron detection techniques and analyze its advantages and disadvantages.
  • DAMIC at SNOLAB (1407.0347)

    Alvaro Chavarria, Javier Tiffenberg, Alexis Aguilar-Arevalo, Dan Amidei, Xavier Bertou, Gustavo Cancelo, Juan Carlos D'Olivo, Juan Estrada, Guillermo Fernandez Moroni, Federico Izraelevitch, Ben Kilminster, Yashmanth Langisetty, Junhui Liao, Jorge Molina, Paolo Privitera, Carolina Salazar, Youssef Sarkis, Vic Scarpine, Tom Schwarz, Miguel Sofo Haro, Frederic Trillaud, Jing Zhou
    June 30, 2014 hep-ex, physics.ins-det, astro-ph.IM
    ... ... ... ... ... ...
    We introduce the fully-depleted charge-coupled device (CCD) as a particle detector. We demonstrate its low energy threshold operation, capable of detecting ionizing energy depositions in a single pixel down to 50 eVee. We present results of energy calibrations from 0.3 keVee to 60 keVee, showing that the CCD is a fully active detector with uniform energy response throughout the silicon target, good resolution (Fano ~0.16), and remarkable linear response to electron energy depositions. We show the capability of the CCD to localize the depth of particle interactions within the silicon target. We discuss the mode of operation and unique imaging capabilities of the CCD, and how they may be exploited to characterize and suppress backgrounds. We present the first results from the deployment of 250 um thick CCDs in SNOLAB, a prototype for the upcoming DAMIC100. DAMIC100 will have a target mass of 0.1 kg and should be able to directly test the CDMS-Si signal within a year of operation.
  • DAMIC: a novel dark matter experiment (1310.6688)

    The DAMIC Collaboration: Alexis A. Aguilar-Arevalo, Xavier Bertou, Juan Carlos D'Olivo, Guillermo Fernandez Moroni, Fernando Marsal, Miguel Sofo Haro, Jing Zhou Instituto de Ciencias Nucleares - Universidad Nacional Autónoma de México, Fermi National Accelerator Laboratory, University of Chicago - Enrico Fermi Institute & Kavli Institute for Cosmological Physics, Universidad Nacional del Sur, Facultad de Ingenieria - Universidad Nacional de Asuncion, University of Michigan, Instituto de Ingeniería - Univesidad Nacional Autónoma de México)
    Oct. 24, 2013 physics.ins-det, astro-ph.IM
    ... ... ... ... ... ...
    DAMIC (Dark Matter in CCDs) is a novel dark matter experiment that has unique sensitivity to dark matter particles with masses below 10 GeV. Due to its low electronic readout noise (R.M.S. ~3 e-) this instrument is able to reach a detection threshold below 0.5 keV nuclear recoil energy, making the search for dark matter particles with low masses possible. We report on early results and experience gained from a detector that has been running at SNOLAB from Dec 2012. We also discuss the measured and expected backgrounds and present the plan for future detectors to be installed in 2014.