We conducted an improved search for the simultaneous capture of two $K$-shell
electrons on the $^{124}$Xe and $^{126}$Xe nuclei with emission of two
neutrinos using 800.0 days of data from the XMASS-I detector. A novel method to
discriminate $\gamma$-ray/$X$-ray or double electron capture signals from
$\beta$-ray background using scintillation time profiles was developed for this
search. No significant signal was found when fitting the observed energy
spectra with the expected signal and background. Therefore, we set the most
stringent lower limits on the half-lives at $2.1 \times 10^{22}$ and $1.9
\times 10^{22}$ years for $^{124}$Xe and $^{126}$Xe, respectively, with 90%
confidence level. These limits improve upon previously reported values by a
factor of 4.5.
-
An annual modulation signal due to the Earth's rotation around the Sun would
be one of the strongest indications of the direct detection of dark matter. In
2016, we reported a search for dark matter by looking for an annual modulation
with the single-phase liquid xenon XMASS-I detector. That analysis indicated a
slightly negative amplitude at low energy. In this work, we included more than
one year of additional data, which more than doubles the exposure to 800 live
days with our 832 kg target mass. When we assume Weakly Interacting Massive
Particle (WIMP) dark matter elastically scattering on the xenon target, the
exclusion upper limit for the WIMP-nucleon cross section was improved by a
factor of two to 1.9$\times$10$^{-41}$cm$^2$ at 8 GeV/c$^2$ with our newly
implemented data selection through a likelihood method. For the
model-independent case, without assuming any specific dark matter model, we
obtained more consistency with the null hypothesis than before with a $p$-value
of 0.11 in the 1--20 keV energy region. This search is probing this region with
an exposure that is larger than that of DAMA/LIBRA. We also did not find any
significant amplitude in the data for periodicity with periods between 50 and
600 days.
-
We established a method to assay $^{210}$Pb and $^{210}$Po contaminations in
the bulk of copper samples using a low-background alpha particle counter. The
achieved sensitivity for the $^{210}$Pb and $^{210}$Po contaminations reaches a
few mBq/kg. Due to this high sensitivity, the $^{210}$Pb and $^{210}$Po
contaminations in oxygen free copper bulk were identified and measured for the
first time. The $^{210}$Pb contaminations of our oxygen free copper samples
were 17-40 mBq/kg. Based on our investigation of copper samples in each
production step, the $^{210}$Pb in oxygen free copper was understood to be a
small residual of an electrolysis process. This method to measure bulk
contaminations of $^{210}$Pb and $^{210}$Po could be applied to other
materials.
-
We report the measurement of the emission time profile of scintillation from
gamma-ray induced events in the XMASS-I 832 kg liquid xenon scintillation
detector. Decay time constant was derived from a comparison of scintillation
photon timing distributions between the observed data and simulated samples in
order to take into account optical processes such as absorption and scattering
in liquid xenon. Calibration data of radioactive sources, $^{55}$Fe,
$^{241}$Am, and $^{57}$Co were used to obtain the decay time constant. Assuming
two decay components, $\tau_1$ and $\tau_2$, the decay time constant $\tau_2$
increased from 27.9 ns to 37.0 ns as the gamma-ray energy increased from 5.9
keV to 122 keV. The accuracy of the measurement was better than 1.5 ns at all
energy levels. A fast decay component with $\tau_1 \sim 2$ ns was necessary to
reproduce data. Energy dependencies of $\tau_2$ and the fraction of the fast
decay component were studied as a function of the kinetic energy of electrons
induced by gamma-rays. The obtained data almost reproduced previously reported
results and extended them to the lower energy region relevant to direct dark
matter searches.
-
A search for dark matter was conducted by looking for an annual modulation
signal due to the Earth's rotation around the Sun using XMASS, a single phase
liquid xenon detector. The data used for this analysis was 359.2 live days
times 832 kg of exposure accumulated between November 2013 and March 2015. When
we assume Weakly Interacting Massive Particle (WIMP) dark matter elastically
scattering on the target nuclei, the exclusion upper limit of the WIMP-nucleon
cross section 4.3$\times$10$^{-41}$cm$^2$ at 8 GeV/c$^2$ was obtained and we
exclude almost all the DAMA/LIBRA allowed region in the 6 to 16 GeV/c$^2$ range
at $\sim$10$^{-40}$cm$^2$. The result of a simple modulation analysis, without
assuming any specific dark matter model but including electron/$\gamma$ events,
showed a slight negative amplitude. The $p$-values obtained with two
independent analyses are 0.014 and 0.068 for null hypothesis, respectively. we
obtained 90\% C.L. upper bounds that can be used to test various models. This
is the first extensive annual modulation search probing this region with an
exposure comparable to DAMA/LIBRA.
-
Double electron capture is a rare nuclear decay process in which two orbital
electrons are captured simultaneously in the same nucleus. Measurement of its
two-neutrino mode would provide a new reference for the calculation of nuclear
matrix elements whereas observation of its neutrinoless mode would demonstrate
lepton number violation. A search for two-neutrino double electron capture on
$^{124}$Xe is performed using 165.9 days of data collected with the XMASS-I
liquid xenon detector. No significant excess above background was observed and
we set a lower limit on the half-life as $4.7 \times 10^{21}$ years at 90%
confidence level. The obtained limit has ruled out parts of some theoretical
expectations. We obtain a lower limit on the $^{126}$Xe two-neutrino double
electron capture half-life of $4.3 \times 10^{21}$ years at 90% confidence
level as well.
-
Bosonic superweakly interacting massive particles (super-WIMPs) are a
candidate for warm dark matter. With the absorption of such a boson by a xenon
atom these dark matter candidates would deposit an energy equivalent to their
rest mass in the detector. This is the first direct detection experiment
exploring the vector super-WIMPs in the mass range between 40 and 120 keV.
Using 165.9 days of data no significant excess above background was observed in
the fiducial mass of 41 kg. The present limit for the vector super-WIMPs
excludes the possibility that such particles constitute all of dark matter. The
absence of a signal also provides the most stringent direct constraint on the
coupling constant of pseudoscalar super-WIMPs to electrons. The unprecedented
sensitivity was achieved exploiting the low background at a level $10^{-4}$
kg$^{-1}$keV$_{ee}^{-1}$day$^{-1}$ in the detector.
-
A search for inelastic scattering of Weakly Interacting Massive Particles
(WIMPs) on the isotope $^{129}$Xe was done in data taken with the single phase
liquid xenon detector XMASS at the Kamioka Observatory. Using a restricted
volume containing 41 kg of LXe at the very center of our detector we observed
no significant excess of events in 165.9 days of data. Our background reduction
allowed us to derive our limits without explicitly subtracting the remaining
events which are compatible with background expectations and derive for e.g. a
50 GeV WIMP an upper limit for its inelastic cross section on $^{129}$Xe nuclei
of 3.2 pb at the 90% confidence level.
-
XMASS, a low-background, large liquid-xenon detector, was used to search for
solar axions that would be produced by bremsstrahlung and Compton effects in
the Sun. With an exposure of 5.6ton days of liquid xenon, the model-independent
limit on the coupling for mass $\ll$ 1keV is $|g_{aee}|< 5.4\times 10^{-11}$
(90% C.L.), which is a factor of two stronger than the existing experimental
limit. The bounds on the axion masses for the DFSZ and KSVZ axion models are
1.9 and 250eV, respectively. In the mass range of 10-40keV, this study produced
the most stringent limit, which is better than that previously derived from
astrophysical arguments regarding the Sun to date.
-
A search for light dark matter using low-threshold data from the single phase
liquid xenon scintillation detector XMASS, has been conducted. Using the entire
835 kg inner volume as target, the analysis threshold can be lowered to 0.3
keVee (electron-equivalent) to search for light dark matter. With low-threshold
data corresponding to a 5591.4 kg$\cdot$day exposure of the detector and
without discriminating between nuclear-recoil and electronic events, XMASS
excludes part of the parameter space favored by other experiments.
-
The XMASS project aims to detect dark matter, pp and $^{7}$Be solar
neutrinos, and neutrinoless double beta decay using ultra pure liquid xenon.
The first phase of the XMASS experiment searches for dark matter. In this
paper, we describe the XMASS detector in detail, including its configuration,
data acquisition equipment and calibration system.