Neutrinoless double-beta decay is a hypothesized process where in some
even-even nuclei it might be possible for two neutrons to simultaneously decay
into two protons and two electrons without emitting neutrinos. This is possible
only if neutrinos are Majorana particles, i.e. fermions that are their own
antiparticles. Neutrinos being Majorana particles would explicitly violate
lepton number conservation, and might play a role in the matter-antimatter
asymmetry in the universe. The observation of neutrinoless double-beta decay
would also provide complementary information related to neutrino masses. The
Majorana Collaboration is constructing the Majorana Demonstrator, a 40-kg
modular germanium detector array, to search for the Neutrinoless double-beta
decay of 76Ge and to demonstrate a background rate at or below 3
counts/(ROI-t-y) in the 4 keV region of interest (ROI) around the 2039 keV
Q-value for 76Ge Neutrinoless double-beta decay. In this paper, we discuss the
physics of neutrinoless double beta decay and then focus on the Majorana
Demonstrator, including its design and approach to achieve ultra-low
backgrounds and the status of the experiment.
-
The MAJORANA DEMONSTRATOR is a planned 40 kg array of Germanium detectors
intended to demonstrate the feasibility of constructing a tonne-scale
experiment that will seek neutrinoless double beta decay ($0\nu\beta\beta$) in
$^{76}\mathrm{Ge}$. Such an experiment would require backgrounds of less than 1
count/tonne-year in the 4 keV region of interest around the 2039 keV Q-value of
the $\beta\beta$ decay. Designing low-noise electronics, which must be placed
in close proximity to the detectors, presents a challenge to reaching this
background target. This paper will discuss the MAJORANA collaboration's
solutions to some of these challenges.
-
The goal of the \textsc{Majorana} \textsc{Demonstrator} project is to search
for 0$\nu\beta\beta$ decay in $^{76}\mathrm{Ge}$. Of all candidate isotopes for
0$\nu\beta\beta$, $^{76}\mathrm{Ge}$ has some of the most favorable
characteristics. Germanium detectors are a well established technology, and in
searches for 0$\nu\beta\beta$, the high purity germanium crystal acts
simultaneously as source and detector. Furthermore, p-type germanium detectors
provide excellent energy resolution and a specially designed point contact
geometry allows for sensitive pulse shape discrimination. This paper will
summarize the experiences the \textsc{Majorana} collaboration made with
enriched germanium detectors manufactured by ORTEC$^{\circledR}$. The process
from production, to characterization and integration in \textsc{Majorana}
mounting structure will be described. A summary of the performance of all
enriched germanium detectors will be given.
-
The Majorana Demonstrator is an ultra-low background physics experiment
searching for the neutrinoless double beta decay of $^{76}$Ge. The Majorana
Parts Tracking Database is used to record the history of components used in the
construction of the Demonstrator. The tracking implementation takes a novel
approach based on the schema-free database technology CouchDB. Transportation,
storage, and processes undergone by parts such as machining or cleaning are
linked to part records. Tracking parts provides a great logistics benefit and
an important quality assurance reference during construction. In addition, the
location history of parts provides an estimate of their exposure to cosmic
radiation. A web application for data entry and a radiation exposure calculator
have been developed as tools for achieving the extreme radio-purity required
for this rare decay search.
-
The Majorana Collaboration is constructing a system containing 40 kg of HPGe
detectors to demonstrate the feasibility and potential of a future tonne-scale
experiment capable of probing the neutrino mass scale in the inverted-hierarchy
region. To realize this, a major goal of the Majorana Demonstrator is to
demonstrate a path forward to achieving a background rate at or below 1
cnt/(ROI-t-y) in the 4 keV region of interest around the Q-value at 2039 keV.
This goal is pursued through a combination of a significant reduction of
radioactive impurities in construction materials with analytical methods for
background rejection, for example using powerful pulse shape analysis
techniques profiting from the p-type point contact HPGe detectors technology.
The effectiveness of these methods is assessed using simulations of the
different background components whose purity levels are constrained from
radioassay measurements.
-
High purity germanium (HPGe) crystals will be used for the MAJORANA
DEMONSTRATOR, where they serve as both the source and the detector for
neutrinoless double beta decay. It is crucial for the experiment to understand
the performance of the HPGe crystals. A variety of crystal properties are being
investigated, including basic properties such as energy resolution, efficiency,
uniformity, capacitance, leakage current and crystal axis orientation, as well
as more sophisticated properties, e.g. pulse shapes and dead layer and
transition layer distributions. In this paper, we will present our measurements
that characterize the HPGe crystals. We will also discuss our simulation
package for the detector characterization setup, and show that additional
information can be extracted from data-simulation comparisons.
-
Neutrinoless double-beta decay experiments can potentially determine the
Majorana or Dirac nature of the neutrino, and aid in understanding the neutrino
absolute mass scale and hierarchy. Future 76Ge-based searches target a
half-life sensitivity of >10^27 y to explore the inverted neutrino mass
hierarchy. Reaching this sensitivity will require a background rate of <1 count
tonne^-1 y^-1 in a 4-keV-wide spectral region of interest surrounding the Q
value of the decay. We investigate the overburden required to reach this
background goal in a tonne-scale experiment with a compact (copper and lead)
shield based on Monte Carlo calculations of cosmic-ray background rates. We
find that, in light of the presently large uncertainties in these types of
calculations, a site with an underground depth >~5200 mwe is required for a
tonne-scale experiment with a compact shield similar to the planned 40-kg
MAJORANA DEMONSTRATOR. The required overburden is highly dependent on the
chosen shielding configuration and could be relaxed significantly if, for
example, a liquid cryogen and water shield, or an active neutron shield were
employed. Operation of the MAJORANA DEMONSTRATOR and GERDA detectors will serve
to reduce the uncertainties on cosmic-ray background rates and will impact the
choice of shielding style and location for a future tonne-scale experiment.
4/2013: The peer review process revealed that one of the veto rejection
factors (the factor-of-4 described on p12) needs to be better established. Our
reevaluation of this parameter to date has not yielded strong support for the
value stated in the manuscript, and we require further study to develop a solid
estimate. This further study will supersede the work described in this
manuscript, and may or may not lead to the same conclusion regarding the ~>5200
mwe requirement for future tonne-scale 76Ge neutrinoless double beta decay
experiments.
-
The MAJORANA DEMONSTRATOR will search for the neutrinoless double-beta decay
of the 76Ge isotope with a mixed array of enriched and natural germanium
detectors. The observation of this rare decay would indicate the neutrino is
its own anti-particle, demonstrate that lepton number is not conserved, and
provide information on the absolute mass-scale of the neutrino. The
DEMONSTRATOR is being assembled at the 4850 foot level of the Sanford
Underground Research Facility in Lead, South Dakota. The array will be
contained in a low-background environment and surrounded by passive and active
shielding. The goals for the DEMONSTRATOR are: demonstrating a background rate
less than 3 t$^{-1}$ y$^{-1}$ in the 4 keV region of interest (ROI) surrounding
the 2039 keV 76Ge endpoint energy; establishing the technology required to
build a tonne-scale germanium based double-beta decay experiment; testing the
recent claim of observation of neutrinoless double-beta decay [H. V.
Klapdor-Kleingrothaus and I. V. Krivosheina, Mod. Phys. Lett. A21, 1547
(2006)]; and performing a direct search for light WIMPs (3-10 GeV).
-
A study of signals originating near the lithium-diffused n+ contact of p-type
point contact (PPC) high purity germanium detectors (HPGe) is presented. The
transition region between the active germanium and the fully dead layer of the
n+ contact is examined. Energy depositions in this transition region are shown
to result in partial charge collection. This provides a mechanism for events
with a well defined energy to contribute to the continuum of the energy
spectrum at lower energies. A novel technique to quantify the contribution from
this source of background is introduced. Experiments that operate germanium
detectors with a very low energy threshold may benefit from the methods
presented herein.
-
The observation of neutrinoless double-beta decay would resolve the Majorana
nature of the neutrino and could provide information on the absolute scale of
the neutrino mass. The initial phase of the Majorana experiment, known as the
Demonstrator, will house 40 kg of Ge in an ultra-low background shielded
environment at the 4850' level of the Sanford Underground Laboratory in Lead,
SD. The objective of the Demonstrator is to determine whether a future 1-tonne
experiment can achieve a background goal of one count per tonne-year in a
narrow region of interest around the 76Ge neutrinoless double-beta decay peak.