-
CREAM (Cosmic Ray Energetics And Mass) is a multi-flight balloon mission
designed to collect direct data on the elemental composition and individual
energy spectra of cosmic rays. Two instrument suites have been built to be
flown alternately on a yearly base. The tungsten/Sci-Fi imaging calorimeter for
the second flight, scheduled for December 2005, was calibrated with electron
and proton beams at CERN. A calibration procedure based on the study of the
longitudinal shower profile is described and preliminary results of the beam
test are presented.
-
Cosmic-ray proton and helium spectra have been measured with the
balloon-borne Cosmic Ray Energetics And Mass experiment flown for 42 days in
Antarctica in the 2004-2005 austral summer season. High-energy cosmic-ray data
were collected at an average altitude of ~38.5 km with an average atmospheric
overburden of ~3.9 g cm$^{-2}$. Individual elements are clearly separated with
a charge resolution of ~0.15 e (in charge units) and ~0.2 e for protons and
helium nuclei, respectively. The measured spectra at the top of the atmosphere
are represented by power laws with a spectral index of -2.66 $\pm$ 0.02 for
protons from 2.5 TeV to 250 TeV and -2.58 $\pm$ 0.02 for helium nuclei from 630
GeV/nucleon to 63 TeV/nucleon. They are harder than previous measurements at a
few tens of GeV/nucleon. The helium flux is higher than that expected from the
extrapolation of the power law fitted to the lower-energy data. The relative
abundance of protons to helium nuclei is 9.1 $\pm$ 0.5 for the range from 2.5
TeV/nucleon to 63 TeV/nucleon. This ratio is considerably smaller than the
previous measurements at a few tens of GeV/nucleon.
-
The final results of processing the data from the balloon-born experiment
ATIC-2 (Antarctica, 2002-2003) for the energy spectra of protons and He, C, O,
Ne, Mg, Si, and Fe nuclei, the spectrum of all particles, and the mean
logarithm of atomic weight of primary cosmic rays as a function of energy are
presented. The final results are based on improvement of the methods used
earlier, in particular, considerably increased resolution of the charge
spectrum. The preliminary conclusions on the significant difference in the
spectra of protons and helium nuclei (the proton spectrum is steeper) and the
non-power character of the spectra of protons and heavier nuclei (flattening of
carbon spectrum at energies above 10 TeV) are confirmed. A complex structure of
the energy dependence of the mean logarithm of atomic weight is found.
-
The balloon-borne Cosmic Ray Energetics And Mass (CREAM) experiment launched
five times from Antarctica has achieved a cumulative flight duration of about
156 days above 99.5% of the atmosphere. The instrument is configured with
complementary and redundant particle detectors designed to extend direct
measurements of cosmic-ray composition to the highest energies practical with
balloon flights. All elements from protons to iron nuclei are separated with
excellent charge resolution. Here we report results from the first two flights
of ~70 days, which indicate hardening of the elemental spectra above ~200
GeV/nucleon and a spectral difference between the two most abundant species,
protons and helium nuclei. These results challenge the view that cosmic-ray
spectra are simple power laws below the so-called knee at ~1015 eV. This
discrepant hardening may result from a relatively nearby source, or it could
represent spectral concavity caused by interactions of cosmic rays with the
accelerating shock. Other possible explanations should also be investigated.
-
The Cosmic Ray Energetics And Mass (CREAM) is a balloon-borne experiment
designed to measure the composition and energy spectra of cosmic rays of charge
Z = 1 to 26 up to an energy of ~ 10^15 eV. CREAM had two successful flights on
long-duration balloons (LDB) launched from Mc- Murdo Station, Antarctica, in
December 2004 and December 2005. CREAM-I achieves a substantial measurement
redundancy by employing multiple detector systems, namely a Timing Charge
Detector and a Silicon Charge Detector (SCD) for particle identification, and a
Transition Radiation Detector and a sampling tungsten/scintillating-fiber
ionization calorimeter (CAL) for energy measurement. In this paper, preliminary
energy spectra of various elements measured with CAL/SCD during the first
42-day flight are presented.
-
The Cosmic Ray Energetics And Mass (CREAM) balloon experiment had two
successful flights in 2004/05 and 2005/06. It was designed to perform energy
measurements from a few GeV up to 1000 TeV, taking advantage of different
detection techniques. The first instrument, CREAM-1, combined a transition
radiation detector with a calorimeter to provide independent energy
measurements of cosmicraynuclei. Each detector was calibrated with particle
beams in a limited range of energies. In order to assess the absolute energy
scale of the instrument and to investigate the systematic effects of each
technique, a cross-calibration was performed by comparing the two independent
energy estimates on selected samples of oxygen and carbon nuclei.
-
During its second Antarctic flight, the CREAM (Cosmic Ray Energetics And
Mass) balloon experiment collected data for 28 days, measuring the charge and
the energy of cosmic rays (CR) with a redundant system of particle
identification and an imaging thin ionization calorimeter. Preliminary direct
measurements of the absolute intensities of individual CR nuclei are reported
in the elemental range from carbon to iron at very high energy.
-
We present new measurements of the energy spectra of cosmic-ray (CR) nuclei
from the second flight of the balloon-borne experiment CREAM (Cosmic Ray
Energetics And Mass). The instrument (CREAM-II) was comprised of detectors
based on different techniques (Cherenkov light, specific ionization in
scintillators and silicon sensors) to provide a redundant charge identification
and a thin ionization calorimeter capable of measuring the energy of cosmic
rays up to several hundreds of TeV. The data analysis is described and the
individual energy spectra of C, O, Ne, Mg, Si and Fe are reported up to ~ 10^14
eV. The spectral shape looks nearly the same for all the primary elements and
can be expressed as a power law in energy E^{-2.66+/-0.04}. The nitrogen
absolute intensity in the energy range 100-800 GeV/n is also measured.
-
The Cosmic Ray Energetics And Mass (CREAM) calorimeter is designed to measure
the spectra of cosmic-ray particles over the energy range from ~10^11 eV to
~10^15 eV. Its first flight as part of the CREAM-I balloon-borne payload in
Antarctica during the 2004/05 season resulted in a recordbreaking 42 days of
exposure. Calorimeter calibration using various beam test data will be
discussed in an attempt to assess the uncertainties of the energy measurements.
-
The CREAM calorimeter, designed to measure the spectra of cosmic-ray nuclei
from under 1 TeV to 1000 TeV, is a 20 radiation length (X0) deep sampling
calorimeter. The calorimeter is comprised of 20 layers of tungsten interleaved
with 20 layers of scintillating fiber ribbons, and is preceded by a pair of
graphite interaction targets providing about 0.42 proton interaction lengths
(\lambda int). The calorimeter was placed in one of CERN's SPS accelerator
beams for calibration and testing. Beams of 150 GeV electrons were used for
calibration, and a variety of electron, proton, and nuclear fragment beams were
used to test the simulation model of the detector. In this paper we discuss the
performance of the calorimeter in the electron beam and compare electron beam
data with simulation results.
-
We present new measurements of the energy spectra of cosmic-ray (CR) nuclei
from the second flight of the balloon-borne experiment Cosmic Ray Energetics
And Mass (CREAM). The instrument included different particle detectors to
provide redundant charge identification and measure the energy of CRs up to
several hundred TeV. The measured individual energy spectra of C, O, Ne, Mg,
Si, and Fe are presented up to $\sim 10^{14}$ eV. The spectral shape looks
nearly the same for these primary elements and it can be fitted to an $E^{-2.66
\pm 0.04}$ power law in energy. Moreover, a new measurement of the absolute
intensity of nitrogen in the 100-800 GeV/$n$ energy range with smaller errors
than previous observations, clearly indicates a hardening of the spectrum at
high energy. The relative abundance of N/O at the top of the atmosphere is
measured to be $0.080 \pm 0.025 $(stat.)$ \pm 0.025 $(sys.) at $\sim $800
GeV/$n$, in good agreement with a recent result from the first CREAM flight.
-
The ATIC balloon-borne experiment measures the energy spectra of elements
from H to Fe in primary cosmic rays from about 100 GeV to 100 TeV. ATIC is
comprised of a fully active bismuth germanate calorimeter, a carbon target with
embedded scintillator hodoscopes, and a silicon matrix that is used as the main
charge detector. The silicon matrix produces good charge resolution for protons
and helium but only partial resolution for heavier nuclei. In the present
paper, the charge resolution of ATIC was improved and backgrounds were reduced
in the region from Be to Si by using the upper layer of the scintillator
hodoscope as an additional charge detector. The flux ratios of nuclei B/C, C/O,
N/O in the energy region from about 10 GeV/nucleon to 300 GeV/nucleon obtained
from this high-resolution, high-quality charge spectra are presented, and
compared with existing theoretical predictions.
-
The results of ATIC-2 baloon experiment (2002-2003) for energy spectra of
protons, He, C, O, Ne, Mg, Si, Fe, some groups of nuclei, and all-particle
spectrum in primary cosmic rays are presented in energy region 50GeV--200TeV.
The conclusion is that the spectra of protons and helium nuclei are essentially
different (the spectrum of protons is steeper) and the spectra of protons and
heavy nuclei have no-power form.
-
CREAM (Cosmic Ray Energetics And Mass) is a multi-flight balloon mission
designed to collect direct data on the elemental composition and individual
energy spectra of cosmic rays. Two instrument suites have been built to be
flown alternately on a yearly base. The tungsten/Sci-Fi imaging calorimeter for
the second flight, scheduled for December 2005, was calibrated with electron
and proton beams at CERN. A calibration procedure based on the study of the
longitudinal shower profile is described and preliminary results of the beam
test are presented.