We analyse the performance of a gas time projection chamber (TPC) as a
high-performance gamma-ray telescope and polarimeter in the e$^+$e$^-$ pair
creation regime. We use data collected at a gamma-ray beam of known
polarisation. The TPC provides two orthogonal projections $(x,z)$ and $(y,z)$
of the tracks induced by each conversion in the gas volume. We use a simple
vertex finder in which vertices and pseudo-tracks exiting from them are
identified.
We study the various contributions to the single-photon angular resolution
using Monte Carlo simulations and compare them with the experimental data and
find that they are in excellent agreement. The distribution of the azimutal
angle of pair conversions shows a bias due to the non-cylindrical-symmetric
structure of the detector. This bias would average out for a long duration
exposure on a space mission, but for this pencil-beam characterisation we have
ensured its accurate simulation by a double systematics control scheme, data
taking with the detector rotated at several angles with respect to the beam
polarisation direction and systematics control with a non-polarised beam.
We measure, for the first time, the polarisation asymmetry of a linearly
polarised gamma-ray beam in the low energy pair creation regime. This sub-GeV
energy range is critical for cosmic sources as their spectra are power laws
which fall quickly as a function of increasing energy.
This work could pave the way to extending polarised gamma-ray astronomy
beyond the MeV energy regime.
-
The MIMAC experiment is a $\mu$-TPC matrix project for directional dark
matter search. Directional detection is a strategy based on the measurement of
the WIMP flux anisotropy due to the solar system motion with respect to the
dark matter halo. The main purpose of MIMAC project is the measurement of the
energy and the direction of nuclear recoils in 3D produced by elastic
scattering of WIMPs. Since June 2012 a bi-chamber prototype is operating at the
Modane underground laboratory. In this paper, we report the first ionization
energy and 3D track observations of nuclear recoils produced by the radon
progeny. This measurement shows the capability of the MIMAC detector and opens
the possibility to explore the low energy recoil directionality signature.
-
The measurement of the direction of WIMP-induced nuclear recoils is a
compelling but technologically challenging strategy to provide an unambiguous
signature of the detection of Galactic dark matter. Most directional detectors
aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas
or solid targets. The main challenge with directional detection is the need for
high spatial resolution over large volumes, which puts strong requirements on
the readout technologies. In this paper we review the various detector readout
technologies used by directional detectors. In particular, we summarize the
challenges, advantages and drawbacks of each approach, and discuss future
prospects for these technologies.
-
Particles weakly interacting with ordinary matter, with an associated mass of
the order of an atomic nucleus (WIMPs), are plausible candidates for Dark
Matter. The direct detection of an elastic collision of a target nuclei induced
by one of these WIMPs has to be discriminated from the signal produced by the
neutrons, which leaves the same signal in a detector. The MIMAC (MIcro-tpc
MAtrix of Chambers) collaboration has developed an original prototype detector
which combines a large pixelated Micromegas coupled with a fast,
self-triggering, electronics. Aspects of the two-chamber module in operation in
the Modane Underground Laboratory are presented: calibration, characterization
of the $^{222}$Rn progeny. A new test bench combining a MIMAC chamber with the
COMIMAC portable quenching line has been set up to characterize the 3D tracks
of low energy ions in the MIMAC gas mixture: the preliminary results thereof
are presented. Future steps are briefly discussed.
-
Current {\gamma}-ray telescopes based on photon conversions to
electron-positron pairs, such as Fermi, use tungsten converters. They suffer of
limited angular resolution at low energies, and their sensitivity drops below 1
GeV. The low multiple scattering in a gaseous detector gives access to higher
angular resolution in the MeV-GeV range, and to the linear polarisation of the
photons through the azimuthal angle of the electron-positron pair.
HARPO is an R&D program to characterise the operation of a TPC (Time
Projection Chamber) as a high angular-resolution and sensitivity telescope and
polarimeter for {\gamma} rays from cosmic sources. It represents a first step
towards a future space instrument. A 30 cm cubic TPC demonstrator was built,
and filled with 2 bar argon-based gas. It was put in a polarised {\gamma}-ray
beam at the NewSUBARU accelerator in Japan in November 2014. Data were taken at
different photon energies from 1.7 MeV to 74 MeV, and with different
polarisation configurations. The electronics setup is described, with an
emphasis on the trigger system. The event reconstruction algorithm is quickly
described, and preliminary measurements of the polarisation of 11 MeVphotons
are shown.
-
A new versatile facility LEETECH for detector R&D, tests and calibration is
designed and constructed. It uses electrons produced by the photoinjector PHIL
at LAL, Orsay and provides a powerful tool for wide range R&D studies of
different detector concepts delivering "mono-chromatic" samples of low energy
electrons with adjustable energy and intensity. Among other innovative
instrumentation techniques, LEETECH will be used for testing various gaseous
tracking detectors and studying new Micromegas/InGrid concept which has very
promising characteristics of spatial resolution and can be a good candidate for
particle tracking and identification. In this paper the importance and expected
characteristics of such facility based on detailed simulation studies are
addressed.
-
The use of resistive technologies to MPGD detectors is taking advantage for
many new applications, including high rate and energetic particle flux
scenarios. The recent use of these technologies in large area detectors makes
necessary to understand and characterize the response of this type of detectors
in order to optimize or constrain the parameters used in its production,
material resistivity, strip width, or layer thickness. The values to be chosen
will depend on the environmental conditions in which the detector will be
placed, and the requirements in time resolution and gain, improving the
detector performance for each given application. We present two different
methods to calculate the propagation of charge diffusion through different
resistive topologies; one is based on a FEM of solving the telegraph equation
in our particular strip detector scheme, the other is based on a
semi-analytical approach of charge diffusion and is used to determine the
charge evolution in a resistive layer.
-
A novel read-out architecture has been developed for the Micromegas detector.
The anode element is made of a resistive layer on a ceramic substrate. The
detector part is entirely separated from the read-out element. Without
significant loss, signals are transmitted by capacitive coupling to the
read-out pads. The detector provides high gas gain, good energy resolution and
the resistive layer assures spark protection to the electronics. This assembly
could be combined with modern pixel array electronic ASICs. This readout
organization is free on how the pixels are designed, arranged and connected. We
present first results taken with a MediPix read-out chip.
-
The EUDET-project was launched to create an infrastructure for developing and
testing new and advanced detector technologies to be used at a future linear
collider. The aim was to make possible experimentation and analysis of data for
institutes, which otherwise could not be realized due to lack of resources. The
infrastructure comprised an analysis and software network, and instrumentation
infrastructures for tracking detectors as well as for calorimetry.
-
The aim of the MIMAC project is to detect non-baryonic Dark Matter with a
directional TPC. The recent Micromegas efforts towards building a large size
detector will be described, in particular the characterization measurements of
a prototype detector of 10 $\times$ 10 cm$^2$ with a 2 dimensional readout
plane. Track reconstruction with alpha particles will be shown.
-
The aim of the MIMAC project is to detect non-baryonic Dark Matter with a
directional TPC using a high precision Micromegas readout plane. We will
describe in detail the recent developments done with bulk Micromegas detectors
as well as the characterisation measurements performed in an
Argon(95%)-Isobutane(5%) mixture. Track measurements with alpha particles will
be shown.
-
We present ultra low energy results taken with the novel Spherical
Proportional Counter. The energy threshold has been pushed down to about 25 eV
and single electrons are clearly collected and detected. To reach such
performance low energy calibration systems have been successfully developed: -
A pulsed UV lamp extracting photoelectrons from the inner surface of the
detector - Various radioactive sources allowing low energy peaks through
fluorescence processes. The bench mark result is the observation of a well
resolved peak at 270 eV due to carbon fluorescence which is unique performance
for such large-massive detector. It opens a new window in dark matter and low
energy neutrino search and may allow detection of neutrinos from a nuclear
reactor or from supernova via neutrino-nucleus elastic scattering
-
A search for the production and non-standard decay of a Higgs boson, h, into
four taus through intermediate pseudoscalars, a, is conducted on 683 pb-1 of
data collected by the ALEPH experiment at centre-of-mass energies from 183 to
209 GeV. No excess of events above background is observed, and exclusion limits
are placed on the combined production cross section times branching ratio,
\xi^2 = \sigma(e+e- --> Zh)/\sigma_{SM}(e+e- --> Zh) x B(h --> aa)x B(a -->
\tau^+\tau^-)^2. For mh < 107 GeV/c2 and 4 < ma < 10 GeV/c2, \xi^2 > 1 is
excluded at the 95% confidence level.
-
We present the case for a dark matter detector with directional sensitivity.
This document was developed at the 2009 CYGNUS workshop on directional dark
matter detection, and contains contributions from theorists and experimental
groups in the field. We describe the need for a dark matter detector with
directional sensitivity; each directional dark matter experiment presents their
project's status; and we close with a feasibility study for scaling up to a one
ton directional detector, which would cost around $150M.
-
We have developed a micro-tpc using a pixelized bulk micromegas coupled to
dedicated acquisition electronics as a read-out allowing to reconstruct the
three dimensional track of a few keV recoils. The prototype has been tested
with the Amande facility at the IRSN-Cadarache providing monochromatic
neutrons. The first results concerning discrimination of a few keV electrons
and proton recoils are presented.
-
Prototypes of MICROMEGAS chambers, using bulk technology and analog readout,
with 1x1cm2 readout segmentation have been built and tested. Measurements in
Ar/iC4H10 (95/5) and Ar/CO2 (80/20) are reported. The dependency of the
prototypes gas gain versus pressure, gas temperature and amplification gap
thickness variations has been measured with an 55Fe source and a method for
temperature and pressure correction of data is presented. A stack of four
chambers has been tested in 200GeV/c and 7GeV/c muon and pion beams
respectively. Measurements of response uniformity, detection efficiency and hit
multiplicity are reported. A bulk MICROMEGAS prototype with embedded digital
readout electronics has been assembled and tested. The chamber layout and first
results are presented.
-
A new type of radiation detector based on a spherical geometry is presented.
The detector consists of a large spherical gas volume with a central electrode
forming a radial electric field. Charges deposited in the conversion volume
drift to the central sensor where they are amplified and collected. We
introduce a small spherical sensor located at the center acting as a
proportional amplification structure. It allows high gas gains to be reached
and operates in a wide range of gas pressures. Signal development and the
absolute amplitude of the response are consistent with predictions. Sub-keV
energy threshold with good energy resolution is achieved. This new concept has
been proven to operate in a simple and robust way and allows reading large
volumes with a single read-out channel. The detector performance presently
achieved is already close to fulfill the demands of many challenging projects
from low energy neutrino physics to dark matter detection with applications in
neutron, alpha and gamma spectroscopy.
-
The International Linear Collider (ILC) Time Projection Chamber (TPC)
transverse space-point resolution goal is 100 microns for all tracks including
stiff 90 degree tracks with the full 2 meter drift. A Micro Pattern Gas
Detector (MPGD) readout TPC can achieve the target resolution with existing
techniques using 1 mm or narrower pads at the expense of increased detector
cost and complexity. The new MPGD readout technique of charge dispersion can
achieve good resolution without resorting to narrow pads. This has been
demonstrated previously for 2 mm x 6 mm pads with GEMs and Micromegas in cosmic
ray tests and in a KEK beam test in a 1 Tesla magnet. We have recently tested a
Micromegas-TPC using the charge dispersion readout concept in a high field
super-conducting magnet at DESY. The measured Micromegas gain was found to be
constant within 0.5% for magnetic fields up to 5 Tesla. With the strong
suppression of transverse diffusion at high magnetic fields, we measure a flat
50 micron resolution at 5 Tesla over the full 15 cm drift length of our
prototype TPC.
-
The Time Projection Chamber (TPC) for the International Linear Collider will
need to measure about 200 track points with a resolution close to 100 $\mu$m. A
Micro Pattern Gas Detector (MPGD) readout TPC could achieve the desired
resolution with existing techniques using sub-millimeter width pads at the
expense of a large increase in the detector cost and complexity. We have
recently applied a new MPGD readout concept of charge dispersion to a prototype
GEM-TPC and demonstrated the feasibility of achieving good resolution with pads
similar in width to the ones used for the proportional wire TPC. The charge
dispersion studies were repeated with a Micromegas TPC amplification stage. We
present here our first results on the Micromegas-TPC resolution with charge
dispersion. The TPC resolution with the Micromegas readout is compared to our
earlier GEM results and to the resolution expected from electron statistics and
transverse diffusion in a gaseous TPC.
-
A novel low-energy ($\sim$few keV) neutrino-oscillation experiment NOSTOS,
combining a strong tritium source and a high pressure spherical Time Projection
Chamber (TPC) detector 10 m in radius has been recently proposed. The
oscillation of neutrinos of such energies occurs within the size of the
detector itself, potentially allowing for a very precise (and rather
systematics-free) measure of the oscillation parameters, in particular, of the
smaller mixing angle $\theta_{13}$, which value could be determined for the
first time. This detector could also be sensitive to the neutrino magnetic
moment and be capable of accurately measure the Weinberg angle at low energy.
The same apparatus, filled with high pressure Xenon, exhibits a high
sensitivity as a Super Nova neutrino detector with extra galactic sensitivity.
The outstanding benefits of the new concept of the spherical TPC will be
presented, as well as the issues to be demonstrated in the near future by an
ongoing R&D. The very first results of small prototype in operation in Saclay
are shown.
-
A novel low-energy neutrino-oscillation experiment NOSTOS, combining a strong
tritium source and a high pressure spherical TPC detector (10 m in radius) has
been recently proposed. The goal of the experiment is to measure the mixing
angle $\theta_{13}$, the neutrino magnetic moment and the Weinberg angle at low
energy. The same apparatus, filled with high pressure Xenon, exhibits a high
sensitivity as a Super Nova neutrino detector with extra galactic sensitivity.
Results of a first prototype will be shown and a short-term experimental
program will be discussed.
-
In this paper we present a novel way to manufacture the bulk Micromegas
detector. A simple process based on the PCB (Printed Circuit Board) technology
is employed to produce the entire sensitive detector. Such fabrication process
could be extended to very large area detectors made by the industry. The low
cost fabrication together with the robustness of the electrode materials will
make it extremely attractive for several applications ranging from particle
physics and astrophysics to medicine
-
Since the summer of 2003, a large Micromegas TPC prototype (1000 channels, 50
cm drift, 50 cm diameter) has been operated in a 2T superconducting magnet at
Saclay. A description of this apparatus and first results from cosmic ray tests
are presented. Additional measurements using simpler detectors with a laser
source, an X-ray gun and radio-active sources are discussed. Drift velocity and
gain measurements, electron attachment and aging studies for a Micromegas TPC
are presented. In particular, using simulations and measurements, it is shown
that an $Argon-CF_4$ mixture is optimal for operation at a future Linear
Collider.
-
We present ion backflow measurements in a Micromegas (MICRO-MEsh GASeous
detector) TPC device developed for the next high energy electron-positron
linear collider under study and a simple explanation for this backflow. A
Micromegas micro-mesh has the intrinsic property to naturally stop a large
fraction of the secondary positive ions created in the avalanche. It is shown
that under some workable conditions on the pitch of the mesh and on the gas
mixture, the ion feedback is equal to the field ratio (ratio of the drift
electric field to the amplification field). Measurements with an intense X-ray
source are in good agreement with calculations and simulations. The conclusion
is that in the electric field conditions foreseen for the Micromegas TPC (drift
and amplification fields respectively equal to 150-200 V/cm and 50-80 kV/cm)
the expected ion backflow will be of the order of $2 - 3 x 10^-3$. In addition,
measurements have been done in a 2T magnetic field: as expected the ion
backflow is not altered by the magnetic field.
-
A small drift chamber was read out by means of a MediPix2 readout chip as
direct anode. A Micromegas foil was placed 50 $\mu$m above the chip, and
electron multiplication occurred in the gap. With a He/Isobutane 80/20 mixture,
gas multiplication factors up to tens of thousands were achieved, resulting in
an efficiency for detecting single electrons of better than 90% . We recorded
many frames containing 2D images with tracks from cosmic muons. Along these
tracks, electron clusters were observed, as well as delta-rays.