Quantum fluctuations in the phase and amplitude quadratures of light set
limitations on the sensitivity of modern optical instruments. The sensitivity
of the interferometric gravitational wave detectors, such as the Advanced Laser
Interferometer Gravitational wave Observatory (LIGO), is limited by quantum
shot noise, quantum radiation pressure noise, and a set of classical noises. We
show how the quantum properties of light can be used to distinguish these
noises using correlation techniques. Particularly, in the first part of the
paper we show estimations of the coating thermal noise and gas phase noise,
hidden below the quantum shot noise in the Advanced LIGO sensitivity curve. We
also make projections on the observatory sensitivity during the next science
runs. In the second part of the paper we discuss the correlation technique that
reveals the quantum radiation pressure noise from the background of classical
noises and shot noise. We apply this technique to the Advanced LIGO data,
collected during the first science run, and experimentally estimate the quantum
correlations and quantum radiation pressure noise in the interferometer for the
first time.
-
This document represents the response of the Intensity Frontier Neutrino
Working Group to the Snowmass charge. We summarize the current status of
neutrino physics and identify many exciting future opportunities for studying
the properties of neutrinos and for addressing important physics and
astrophysics questions with neutrinos.
-
In early 2010, the Long-Baseline Neutrino Experiment (LBNE) science
collaboration initiated a study to investigate the physics potential of the
experiment with a broad set of different beam, near- and far-detector
configurations. Nine initial topics were identified as scientific areas that
motivate construction of a long-baseline neutrino experiment with a very large
far detector. We summarize the scientific justification for each topic and the
estimated performance for a set of far detector reference configurations. We
report also on a study of optimized beam parameters and the physics capability
of proposed Near Detector configurations. This document was presented to the
collaboration in fall 2010 and updated with minor modifications in early 2011.
-
The Dark Matter Time Projection Chamber (DMTPC) collaboration is developing
low-pressure gas TPC detectors for measuring WIMP-nucleon interactions. Optical
readout with CCD cameras allows for the detection for the daily modulation in
the direction of the dark matter wind, while several charge readout channels
allow for the measurement of additional recoil properties. In this article, we
show that the addition of the charge readout analysis to the CCD allows us too
obtain a statistics-limited 90% C.L. upper limit on the $e^-$ rejection factor
of $5.6\times10^{-6}$ for recoils with energies between 40 and 200
keV$_{\mathrm{ee}}$. In addition, requiring coincidence between charge signals
and light in the CCD reduces CCD-specific backgrounds by more than two orders
of magnitude.
-
The Dark Matter Time Projection Chamber (DMTPC) experiment uses CF_4 gas at
low pressure (0.1 atm) to search for the directional signature of Galactic WIMP
dark matter. We describe the DMTPC apparatus and summarize recent results from
a 35.7 g-day exposure surface run at MIT. After nuclear recoil cuts are applied
to the data, we find 105 candidate events in the energy range 80 - 200 keV,
which is consistent with the expected cosmogenic neutron background. Using this
data, we obtain a limit on the spin-dependent WIMP-proton cross-section of 2.0
\times 10^{-33} cm^2 at a WIMP mass of 115 GeV/c^2. This detector is currently
deployed underground at the Waste Isolation Pilot Plant in New Mexico.
-
The Dark Matter Time Projection Chamber (DMTPC) is a low pressure (75 Torr
CF4) 10 liter detector capable of measuring the vector direction of nuclear
recoils with the goal of directional dark matter detection. In this paper we
present the first dark matter limit from DMTPC. In an analysis window of 80-200
keV recoil energy, based on a 35.7 g-day exposure, we set a 90% C.L. upper
limit on the spin-dependent WIMP-proton cross section of 2.0 x 10^{-33} cm^{2}
for 115 GeV/c^2 dark matter particle mass.
-
We present the case for a dark matter detector with directional sensitivity.
This document was developed at the 2009 CYGNUS workshop on directional dark
matter detection, and contains contributions from theorists and experimental
groups in the field. We describe the need for a dark matter detector with
directional sensitivity; each directional dark matter experiment presents their
project's status; and we close with a feasibility study for scaling up to a one
ton directional detector, which would cost around $150M.
-
By correlating nuclear recoil directions with the Earth's direction of motion
through the Galaxy, a directional dark matter detector can unambiguously detect
Weakly Interacting Massive Particles (WIMPs), even in the presence of
backgrounds. Here, we describe the Dark Matter Time-Projection Chamber (DMTPC)
detector, a TPC filled with CF4 gas at low pressure (0.1 atm). Using this
detector, we have measured the vector direction (head-tail) of nuclear recoils
down to energies of 100 keV with an angular resolution of <15 degrees. To study
our detector backgrounds, we have operated in a basement laboratory on the MIT
campus for several months. We are currently building a new, high-radiopurity
detector for deployment underground at the Waste Isolation Pilot Plant facility
in New Mexico.
-
We show data from a new type of detector that can be used to determine
neutron flux, energy distribution, and direction of neutron motion for both
fast and thermal neutrons. Many neutron detectors are plagued by large
backgrounds from x-rays and gamma rays, and most current neutron detectors lack
single-event energy sensitivity or any information on neutron directionality.
Even the best detectors are limited by cosmic ray neutron backgrounds. All
applications (neutron scattering and radiography, measurements of solar and
cosmic ray neutron flux, measurements of neutron interaction cross sections,
monitoring of neutrons at nuclear facilities, oil exploration, and searches for
fissile weapons of mass destruction) will benefit from the improved neutron
detection sensitivity and improved measurements of neutron properties made
possible by this detector. The detector is free of backgrounds from x-rays,
gamma rays, beta particles, relativistic singely charged particles and cosmic
ray neutrons. It is sensitive to thermal neutrons, fission neutrons, and high
energy neutrons, with detection features distinctive for each energy range. It
is capable of determining the location of a source of fission neutrons based on
characteristics of elastic scattering of neutrons by helium nuclei. The
detector we have constructed could identify one gram of reactor grade
plutonium, one meter away, with less than one minute of observation time.
-
Carbon-tetrafluoride (CF4) is used as a counting gas in particle detectors,
but some of its properties that are of interest for large time-projection
chambers are not well known. We measure the mean energy, which is proportional
to the diffusion coefficent, and the attentuation coefficient of electron
propagation in CF4 gas using a 10-liter dark matter detector prototype of the
DMTPC project.
-
The DMTPC detector is a low-pressure CF4 TPC with optical readout for
directional detection of Dark Matter. The combination of the energy and
directional tracking information allows for an efficient suppression of all
backgrounds. The choice of gas (CF4) makes this detector particularly sensitive
to spin-dependent interactions.
-
Directional detection of Dark Matter allows for unambiguous direct detection
of WIMPs as well as discrimination between various Dark Matter models in our
galaxy. The DMTPC detector is a low-pressure TPC with optical readout designed
for directional direct detection of WIMPs. By using CF4 gas as the active
material, the detector also has excellent sensitivity to spin-dependent
interactions of Dark Matter on protons.
-
The known direction of motion of dark matter particles relative to the Earth
may be a key for their unambiguous identification even in the presence of
backgrounds. We describe a prototype detector that is able to reconstruct
direction vectors of weakly interacting massive particles that may the dominant
constituent of the dark matter in our galaxy. The detector uses a low-density
gas (CF4) in a 10liter time-projection chamber with mesh-based electrodes and
optical and charge readout. Initial results confirm good performance in the
reconstruction of direction angle and sense ('head-tail') for low-momentum
nuclear recoils.
-
Directional detection of Dark Matter allows for unambiguous direct detection
of WIMPs as well as discrimination between various Dark Matter models in our
galaxy. The DMTPC detector is a low-pressure TPC with optical readout designed
for directional direct detection of WIMPs. By using CF4 gas as the active
material, the detector also has excellent sensitivity to spin-dependent
interactions of Dark Matter on protons.
-
Directional detection can provide unambiguous observation of Dark Matter
interactions even in presence of insidious backgrounds. The DM-TPC
collaboration is developing a detector with the goal of measuring the direction
and sense of nuclear recoils produced in Dark Matter interactions. The detector
consists of a Time Projection Chamber with optical readout filled with CF$_4$
gas at low pressure. A collision between a WIMP and a gas molecule results in a
nuclear recoil of 1-2 mm. The measurement of the energy loss along the recoil
allows us to determine the sense and the direction of the recoil. Results from
a prototype detector operated in a low-energy neutron beam clearly demonstrate
the suitability of this approach to measure directionality. A cubic meter
prototype, which is now being designed, will allow us to set competitive limits
on spin-dependent Dark Matter interactions using a directional detector.
-
Directional detection can provide unambiguous observation of Dark Matter
interactions even in presence of insidious backgrounds. The DM-TPC
collaboration is developing a detector with the goal of measuring the direction
and sense of nuclear recoils produced in Dark Matter interactions. The detector
consists of a Time Projection Chamber with optical readout filled with CF$_4$
gas at low pressure. A collision between a WIMP and a gas molecule results in a
nuclear recoil of 1-2 mm. The measurement of the energy loss along the recoil
allows us to determine the sense and the direction of the recoil.
Results from a prototype detector operated in a low-energy neutron beam
clearly demonstrate the suitability of this approach to measure directionality.
A full-scale module with an active volume of about one cubic meter is now being
designed. This detector, which will be operated underground in 2009, will allow
us to set competitive limits on spin-dependent Dark Matter interactions using a
directional detector.
-
This paper presents a measurement of the ratio of photon to electron
production and the scintillation spectrum in a popular gas for time pro jection
chambers, carbon tetrafluoride (CF4), over the range of 200 to 800 nm; the
ratio is measured to be 0.34+/-0.04. This result is of particular importance
for a new generation of dark matter time projection chambers with directional
sensitivity which use CF4 as a fill gas.
-
We present new results with a prototype detector that is being developed by
the DMTPC collaboration for the measurement of the direction tag (head-tail) of
dark matter wind. We use neutrons from a Cf-252 source to create low-momentum
nuclear recoils in elastic scattering with the residual gas nuclei. The recoil
track is imaged in low-pressure time-projection chamber with optical readout.
We measure the ionization rate along the recoil trajectory, which allows us to
determine the direction tag of the incoming neutrons.
-
Directional detection of dark matter can provide unambiguous observation of
dark matter interactions even in the presence of background. This article
presents an experimental method to measure the direction tag ("head-tail") of
the dark matter wind by detecting the scintillation light created by the
elastic nuclear recoils in the scattering of dark matter particles with the
detector material. The technique is demonstrated by tagging the direction of
the nuclear recoils created in the scattering of low-energy neutrons with CF4
in a low-pressure time-projection chamber that is developed by the DMTPC
collaboration. The measurement of the decreasing ionization rate along the
recoil trajectory provides the direction tag of the incoming neutrons, and
proves that the "head-tail" effect can be observed.