The TOTEM collaboration has measured the proton-proton total cross section at
$\sqrt{s}=13$ TeV with a luminosity-independent method. Using dedicated
$\beta^{*}=90$ m beam optics, the Roman Pots were inserted very close to the
beam. The inelastic scattering rate has been measured by the T1 and T2
telescopes during the same LHC fill. After applying the optical theorem the
total proton-proton cross section is $\sigma_{\rm tot}=(110.6 \pm 3.4$) mb,
well in agreement with the extrapolation from lower energies. This method also
allows one to derive the luminosity-independent elastic and inelastic cross
sections: $\sigma_{\rm el} = (31.0 \pm 1.7)$ mb and $\sigma_{\rm inel} = (79.5
\pm 1.8)$ mb.
-
An analysis software was developed for the high aspect ratio optical scanning
system in the Detec- tor Laboratory of the University of Helsinki and the
Helsinki Institute of Physics. The system is used e.g. in the quality assurance
of the GEM-TPC detectors being developed for the beam diagnostics system of the
SuperFRS at future FAIR facility. The software was tested by analyzing five
CERN standard GEM foils scanned with the optical scanning system. The
measurement uncertainty of the diameter of the GEM holes and the pitch of the
hole pattern was found to be 0.5 {\mu}m and 0.3 {\mu}m, respectively. The
software design and the performance are discussed. The correlation between the
GEM hole size distribution and the corresponding gain variation was studied by
comparing them against a detailed gain mapping of a foil and a set of six lower
precision control measurements. It can be seen that a qualitative estimation of
the behavior of the local variation in gain across the GEM foil can be made
based on the measured sizes of the outer and inner holes.
-
This paper describes the design and the performance of the timing detector
developed by the TOTEM Collaboration for the Roman Pots (RPs) to measure the
Time-Of-Flight (TOF) of the protons produced in central diffractive
interactions at the LHC. The measurement of the TOF of the protons allows the
determination of the longitudinal position of the proton interaction vertex and
its association with one of the vertices reconstructed by the CMS detectors.
The TOF detector is based on single crystal Chemical Vapor Deposition (scCVD)
diamond plates and is designed to measure the protons TOF with about 50 ps time
precision. This upgrade to the TOTEM apparatus will be used in the LHC run 2
and will tag the central diffractive events up to an interaction pileup of
about 1. A dedicated fast and low noise electronics for the signal
amplification has been developed. The digitization of the diamond signal is
performed by sampling the waveform. After introducing the physics studies that
will most profit from the addition of these new detectors, we discuss in detail
the optimization and the performance of the first TOF detector installed in the
LHC in November 2015.
-
The GEM-TPC detector will be part of the standard Super-FRS detection system,
as tracker detectors at several focal stations along the separator and its
three branches.
-
The FAIR facility is an international accelerator centre for research with
ion and antiproton beams. It is being built at Darmstadt, Germany as an
extension to the current GSI research institute. One major part of the facility
will be the Super-FRS separator, which will be include in phase one of the
project construction. The NUSTAR experiments will benefit from the Super-FRS,
which will deliver an unprecedented range of radioactive ion beams (RIB). These
experiments will use beams of different energies and characteristics in three
different branches; the high-energy which utilizes the RIB at relativistic
energies 300-1500 MeV /u as created in the production process, the low energy
branch aims to use beams in the range of 0-150 MeV/u whereas the ring branch
will cool and store beams in the NESR ring. The main tasks for the Super-FRS
beam diagnostics chambers will be for the set up and adjustment of the
separator as well as to provide tracking and event-by-event particle
identification. The Helsinki Institute of Physics, the Comenius University, and
the Detector Laboratory and Experimental electronics at GSI are in a joint R&D
phase of a GEM-TPC detector which could satisfy the requirements of such
diagnostics and tracking chambers in terms of tracking efficiency, space
resolution, count rate capability and momenta resolution. The current status of
the first prototype and the preliminary results from the test beam campaign
S417 using the n-Xyter chips mounted on GEMEX cards will be shown.
-
The TOTEM experiment at the CERN LHC has measured elastic proton-proton
scattering at the centre-of-mass energy $\sqrt{s}$ = 8 TeV and four-momentum
transfers squared, |t|, from 6 x $10^{-4}$ GeV$^2$ to 0.2 GeV$^2$. Near the
lower end of the |t|-interval the differential cross-section is sensitive to
the interference between the hadronic and the electromagnetic scattering
amplitudes. This article presents the elastic cross-section measurement and the
constraints it imposes on the functional forms of the modulus and phase of the
hadronic elastic amplitude. The data exclude the traditional Simplified West
and Yennie interference formula that requires a constant phase and a purely
exponential modulus of the hadronic amplitude. For parametrisations of the
hadronic modulus with second- or third-order polynomials in the exponent, the
data are compatible with hadronic phase functions giving either central or
peripheral behaviour in the impact parameter picture of elastic scattering. In
both cases, the $\rho$-parameter is found to be 0.12 $\pm$ 0.03. The results
for the total hadronic cross-section are $\sigma_{tot}$ = (102.9 $\pm$ 2.3) mb
and (103.0 $\pm$ 2.3) mb for central and peripheral phase formulations,
respectively. Both are consistent with previous TOTEM measurements.
-
The TOTEM experiment has made a precise measurement of the elastic
proton-proton differential cross-section at the centre-of-mass energy sqrt(s) =
8 TeV based on a high-statistics data sample obtained with the beta* = 90
optics. Both the statistical and systematic uncertainties remain below 1%,
except for the t-independent contribution from the overall normalisation. This
unprecedented precision allows to exclude a purely exponential differential
cross-section in the range of four-momentum transfer squared 0.027 < |t| < 0.2
GeV^2 with a significance greater than 7 sigma. Two extended parametrisations,
with quadratic and cubic polynomials in the exponent, are shown to be well
compatible with the data. Using them for the differential cross-section
extrapolation to t = 0, and further applying the optical theorem, yields total
cross-section estimates of (101.5 +- 2.1) mb and (101.9 +- 2.1) mb,
respectively, in agreement with previous TOTEM measurements.
-
The pseudorapidity density of charged particles dN(ch)/deta is measured by
the TOTEM experiment in pp collisions at sqrt(s) = 8 TeV within the range 3.9 <
eta < 4.7 and -6.95 < eta < -6.9. Data were collected in a low intensity LHC
run with collisions occurring at a distance of 11.25 m from the nominal
interaction point. The data sample is expected to include 96-97\% of the
inelastic proton-proton interactions. The measurement reported here considers
charged particles with p_T > 0 MeV/c, produced in inelastic interactions with
at least one charged particle in -7 < eta < -6 or 3.7 < eta <4.8 . The
dN(ch)/deta has been found to decrease with |eta|, from 5.11 +- 0.73 at eta =
3.95 to 1.81 +- 0.56 at eta= - 6.925. Several MC generators are compared to the
data and are found to be within the systematic uncertainty of the measurement.
-
Precise knowledge of the beam optics at the LHC is crucial to fulfil the
physics goals of the TOTEM experiment, where the kinematics of the scattered
protons is reconstructed with the near-beam telescopes -- so-called Roman Pots
(RP). Before being detected, the protons' trajectories are influenced by the
magnetic fields of the accelerator lattice. Thus precise understanding of the
proton transport is of key importance for the experiment. A novel method of
optics evaluation is proposed which exploits kinematical distributions of
elastically scattered protons observed in the RPs. Theoretical predictions, as
well as Monte Carlo studies, show that the residual uncertainty of this optics
estimation method is smaller than 0.25 percent.
-
The TOTEM Experiment is designed to measure the total proton-proton
cross-section with the luminosity-independent method and to study elastic and
diffractive pp scattering at the LHC. To achieve optimum forward coverage for
charged particles emitted by the pp collisions in the interaction point IP5,
two tracking telescopes, T1 and T2, are installed on each side of the IP in the
pseudorapidity region 3.1 < = |eta | < = 6.5, and special movable beam-pipe
insertions - called Roman Pots (RP) - are placed at distances of +- 147 m and
+- 220 m from IP5. This article describes in detail the working of the TOTEM
detector to produce physics results in the first three years of operation and
data taking at the LHC.
-
The first double diffractive cross-section measurement in the very forward
region has been carried out by the TOTEM experiment at the LHC with
center-of-mass energy of sqrt(s)=7 TeV. By utilizing the very forward TOTEM
tracking detectors T1 and T2, which extend up to |eta|=6.5, a clean sample of
double diffractive pp events was extracted. From these events, we measured the
cross-section sigma_DD =(116 +- 25) mub for events where both diffractive
systems have 4.7 <|eta|_min < 6.5 .
-
The TOTEM experiment has measured the charged particle pseudorapidity density
dN_{ch}/deta in pp collisions at sqrt{s} = 7 TeV for 5.3<|eta|<6.4 in events
with at least one charged particle with transverse momentum above 40 MeV/c in
this pseudorapidity range. This extends the analogous measurement performed by
the other LHC experiments to the previously unexplored forward eta region. The
measurement refers to more than 99% of non-diffractive processes and to single
and double diffractive processes with diffractive masses above ~3.4 GeV/c^2,
corresponding to about 95% of the total inelastic cross-section. The
dN_{ch}/deta has been found to decrease with |eta|, from 3.84 pm 0.01(stat) pm
0.37(syst) at |eta| = 5.375 to 2.38 pm 0.01(stat) pm 0.21(syst) at |eta| =
6.375. Several MC generators have been compared to data; none of them has been
found to fully describe the measurement.
-
Proton-proton elastic scattering has been measured by the TOTEM experiment at
the CERN Large Hadron Collider at $\sqrt{s} = 7 $ TeV in special runs with the
Roman Pot detectors placed as close to the outgoing beam as seven times the
transverse beam size. The differential cross-section measurements are reported
in the |t|-range of 0.36 to 2.5 GeV^2. Extending the range of data to low t
values from 0.02 to 0.33 GeV^2,and utilizing the luminosity measurements of
CMS, the total proton-proton cross section at sqrt(s) = 7 TeV is measured to be
(98.3 +- 0.2(stat) +- 2.8(syst)) mb.
-
Proton-proton elastic scattering has been measured by the TOTEM experiment at
the CERN Large Hadron Collider at {\surd}s = 7 TeV in dedicated runs with the
Roman Pot detectors placed as close as seven times the transverse beam size
(sbeam) from the outgoing beams. After careful study of the accelerator optics
and the detector alignment, |t|, the square of four-momentum transferred in the
elastic scattering process, has been determined with an uncertainty of d t =
0.1GeV p|t|. In this letter, first results of the differential cross section
are presented covering a |t|-range from 0.36 to 2.5GeV2. The differential
cross-section in the range 0.36 < |t| < 0.47 GeV2 is described by an
exponential with a slope parameter B = (23.6{\pm}0.5stat {\pm}0.4syst)GeV-2,
followed by a significant diffractive minimum at |t| =
(0.53{\pm}0.01stat{\pm}0.01syst)GeV2. For |t|-values larger than ~ 1.5GeV2, the
cross-section exhibits a power law behaviour with an exponent of -7.8_\pm}
0.3stat{\pm}0.1syst. When compared to predictions based on the different
available models, the data show a strong discriminative power despite the small
t-range covered.
-
TOTEM has measured the differential cross-section for elastic proton-proton
scattering at the LHC energy of {\srud}s = 7TeV analysing data from a short run
with dedicated large {\beta} * optics. A single exponential fit with a slope B
= (20:1{\pm}0:2stat {\pm}0:3syst)GeV-2 describes the range of the four-momentum
transfer squared |t| from 0.02 to 0.33 GeV2. After the extrapolation to |t| =
0, a total elastic scattering cross-section of (24:8{\pm}0:2stat {\pm}1:2syst)
mb was obtained. Applying the optical theorem and using the luminosity
measurement from CMS, a total proton-proton cross-section of (98:3{\pm}0:2stat
{\pm}2:8syst) mb was deduced which is in good agreement with the expectation
from the overall fit of previously measured data over a large range of
center-of-mass energies. From the total and elastic pp cross-section
measurements, an inelastic pp cross-section of (73:5{\pm}0:6stat +1:8 -1:3
syst) mb was inferred. PACS 13.60.Hb: Total and inclusive cross sections
-
The first physics results from the TOTEM experiment are here reported,
concerning the measurements of the total, differential elastic, elastic and
inelastic pp cross-section at the LHC energy of $\sqrt{s}$ = 7 TeV, obtained
using the luminosity measurement from CMS. A preliminary measurement of the
forward charged particle $\eta$ distribution is also shown.
-
2nd workshop on the implications of HERA for LHC physics. Working groups:
Parton Density Functions Multi-jet final states and energy flows Heavy quarks
(charm and beauty) Diffraction Cosmic Rays Monte Carlos and Tools
-
The TOTEM experiment at the LHC measures the total proton-proton cross
section with the luminosity-independent method and the elastic proton-proton
cross-section over a wide |t|-range. It also performs a comprehensive study of
diffraction, spanning from cross-section measurements of individual diffractive
processes to the analysis of their event topologies. Hard diffraction will be
studied in collaboration with CMS taking advantage of the large common rapidity
coverage for charged and neutral particle detection and the large variety of
trigger possibilities even at large luminosities. TOTEM will take data under
all LHC beam conditions including standard high luminosity runs to maximize its
physics reach. This contribution describes the main features of the TOTEM
physics programme including measurements to be made in the early LHC runs. In
addition, a novel scheme to extend the diffractive proton acceptance for high
luminosity runs by installing proton detectors at IP3 is described.