-
The prospect of pileup induced backgrounds at the High Luminosity LHC
(HL-LHC) has stimulated intense interest in developing technologies for charged
particle detection with accurate timing at high rates. The required accuracy
follows directly from the nominal interaction distribution within a bunch
crossing ($\sigma_z\sim5$ cm, $\sigma_t\sim170$ ps). A time resolution of the
order of 20-30 ps would lead to significant reduction of these backgrounds.
With this goal, we present a new detection concept called PICOSEC, which is
based on a "two-stage" Micromegas detector coupled to a Cherenkov radiator and
equipped with a photocathode. First results obtained with this new detector
yield a time resolution of 24 ps for 150 GeV muons, and 76 ps for single
photoelectrons.
-
Charging-up processes affecting gain stability in Thick Gas Electron
Multipliers (THGEM) were studied with a dedicated simulation toolkit.
Integrated with Garfield++, it provides an effective platform for systematic
phenomenological studies of charging-up processes in MPGD detectors. We
describe the simulation tool and the fine-tuning of the step-size required for
the algorithm convergence, in relation to physical parameters. Simulation
results of gain stability over time in THGEM detectors are presented, exploring
the role of electrode-thickness and applied voltage on its evolution. The
results show that the total amount of irradiated charge through electrode's
hole needed for reaching gain stabilization is in the range of tens to hundreds
of pC, depending on the detector geometry and operational voltage. These
results are in agreement with experimental observations presented previously.
-
Graphene is a single layer of carbon atoms arranged in a honeycomb lattice
with remarkable mechanical and electrical properties. Regarded as the thinnest
and narrowest conductive mesh, it has drastically different transmission
behaviours when bombarded with electrons and ions in vacuum. This property, if
confirmed in gas, may be a definitive solution for the ion back-flow problem in
gaseous detectors. In order to ascertain this aspect, graphene layers of
dimensions of about 2x2cm$^2$, grown on a copper substrate, are transferred
onto a flat metal surface with holes, so that the graphene layer is freely
suspended. The graphene and the support are installed into a gaseous detector
equipped with a triple Gaseous Electron Multiplier (GEM), and the transparency
properties to electrons and ions are studied in gas as a function of the
electric fields. The techniques to produce the graphene samples are described,
and we report on preliminary tests of graphene-coated GEMs.
-
A comprehensive study, supported by systematic measurements and numerical
computations, of the intrinsic limits of multi-GEM detectors when exposed to
very high particle fluxes or operated at very large gains is presented. The
observed variations of the gain, of the ion back-flow, and of the pulse height
spectra are explained in terms of the effects of the spatial distribution of
positive ions and their movement throughout the amplification structure. The
intrinsic dynamic character of the processes involved imposes the use of a
non-standard simulation tool for the interpretation of the measurements.
Computations done with a Finite Element Analysis software reproduce the
observed behaviour of the detector. The impact of this detailed description of
the detector in extreme conditions is multiple: it clarifies some detector
behaviours already observed, it helps in defining intrinsic limits of the GEM
technology, and it suggests ways to extend them.
-
We report the performance of a 10 atm Xenon/trimethylamine time projection
chamber (TPC) for the detection of X-rays (30 keV) and gamma-rays (0.511-1.275
MeV) in conjunction with the accurate tracking of the associated electrons.
When operated at such a high pressure and in 1%-admixtures, trimethylamine
(TMA) endows Xenon with an extremely low electron diffusion (1.3 +-0.13
mm-sigma (longitudinal), 0.8 +-0.15 mm-sigma (transverse) along 1 m drift)
besides forming a convenient Penning-Fluorescent mixture. The TPC, that houses
1.1 kg of gas in its active volume, operated continuously for 100 live-days in
charge amplification mode. The readout was performed through the recently
introduced microbulk Micromegas technology and the AFTER chip, providing a 3D
voxelization of 8mm x 8mm x 1.2mm for approximately 10 cm/MeV-long electron
tracks. This work was developed as part of the R&D program of the NEXT
collaboration for future detector upgrades in the search of the 0bbnu decay in
136Xe, specifically those based on novel gas mixtures. Therefore we ultimately
focus on the calorimetric and topological properties of the reconstructed
MeV-electron tracks.
-
We model the response of a state of the art micro-hole single-stage charge
amplication device (`microbulk' Micromegas) in a gaseous atmosphere consisting
of Xenon/trimethylamine at various concentrations and pressures. The amplifying
structure, made with photo-lithographic techniques similar to those followed in
the fabrication of gas electron multipliers (GEMs), consisted of a 100 um-side
equilateral-triangle pattern with 50 um-diameter holes placed at its vertexes.
Once the primary electrons are guided into the holes by virtue of an optimized
field configuration, avalanches develop along the 50 um-height channels etched
out of the original doubly copper-clad polyimide foil. In order to properly
account for the strong field gradients at the holes' entrance as well as for
the fluctuations of the avalanche process (that ultimately determine the
achievable energy resolution), we abandoned the hydrodynamic framework,
resorting to a purely microscopic description of the electron trajectories as
obtained from elementary cross-sections. We show that achieving a satisfactory
description needs additional assumptions about atom-molecule (Penning) transfer
reactions and charge recombination to be made.
-
Graphene is a single layer of carbon atoms arranged in a honeycomb lattice
with remarkable mechanical, electrical and optical properties. For the first
time graphene layers suspended on copper meshes were installed into a gas
detector equipped with a gaseous electron multiplier. Measurements of low
energy electron and ion transfer through graphene were conducted. In this paper
we describe the sample preparation for suspended graphene layers, the testing
procedures and we discuss the preliminary results followed by a prospect of
further applications.
-
Electroluminescence produced during avalanche development in gaseous
avalanche detectors is an useful information for triggering, calorimetry and
tracking in gaseous detectors. Noble gases present high electroluminescence
yields, emitting mainly in the VUV region. The photons can provide signal
readout if appropriate photosensors are used. Micropattern gaseous detectors
are good candidates for signal amplification in high background and/or low rate
experiments due to their high electroluminescence yields and radiopurity. In
this work, the VUV light responses of the Gas Electron Multiplier and of the
Micro-Hole Strip Plate, working with pure xenon, are simulated and studied in
detail using a new and versatile C++ toolkit. It is shown that the solid angle
subtended by a photosensor placed below the microstructures depends on the
operating conditions. The obtained absolute EL yields, determined for different
gas pressures and as functions of the applied voltage, are compared with those
determined experimentally.
-
The NA60 experiment has studied J/psi production in p-A collisions at 158 and
400 GeV, at the CERN SPS. Nuclear effects on the J/psi yield have been
estimated from the A-dependence of the production cross section ratios
sigma_{J/psi}^{A}/sigma_{J/psi}^{Be} (A=Al, Cu, In, W, Pb, U). We observe a
significant nuclear suppression of the J/psi yield per nucleon-nucleon
collision, with a larger effect at lower incident energy, and we compare this
result with previous observations by other fixed-target experiments. An attempt
to disentangle the different contributions to the observed suppression has been
carried out by studying the dependence of nuclear effects on x_2, the fraction
of nucleon momentum carried by the interacting parton in the target nucleus.
-
The NA60 experiment at the CERN SPS has studied $\phi$ meson production in
In-In collisions at 158A GeV via both the $K^+K^-$ and the $\mu^+\mu^-$ decay
channels. The yields and inverse slope parameters of the $m_T$ spectra observed
in the two channels are compatible within errors, different from the large
discrepancies seen in Pb-Pb collisions between the hadronic (NA49) and dimuon
(NA50) decay channels. Possible physics implications are discussed.
-
A good understanding of electroluminescence is a prerequisite when optimising
double-phase noble gas detectors for Dark Matter searches and high-pressure
xenon TPCs for neutrinoless double beta decay detection.
A simulation toolkit for calculating the emission of light through electron
impact on neon, argon, krypton and xenon has been developed using the Magboltz
and Garfield programs. Calculated excitation and electroluminescence
efficiencies, electroluminescence yield and associated statistical fluctuations
are presented as a function of electric field. Good agreement with experiment
and with Monte Carlo simulations has been obtained.
-
The design, construction, and commissioning of the ALICE Time-Projection
Chamber (TPC) is described. It is the main device for pattern recognition,
tracking, and identification of charged particles in the ALICE experiment at
the CERN LHC. The TPC is cylindrical in shape with a volume close to 90 m^3 and
is operated in a 0.5 T solenoidal magnetic field parallel to its axis.
In this paper we describe in detail the design considerations for this
detector for operation in the extreme multiplicity environment of central
Pb--Pb collisions at LHC energy. The implementation of the resulting
requirements into hardware (field cage, read-out chambers, electronics),
infrastructure (gas and cooling system, laser-calibration system), and software
led to many technical innovations which are described along with a presentation
of all the major components of the detector, as currently realized. We also
report on the performance achieved after completion of the first round of
stand-alone calibration runs and demonstrate results close to those specified
in the TPC Technical Design Report.
-
The NA60 experiment at the CERN SPS has studied dimuon production in 158A GeV
In-In collisions. The strong excess of pairs above the known sources found in
the complete mass region 0.2<M<2.6 GeV has previously been interpreted as
thermal radiation. We now present first results on the associated angular
distributions. Using the Collins-Soper reference frame, the structure function
parameters \lambda, \mu and \nu are measured to be zero, and the projected
distributions in polar and azimuth angles are found to be uniform. The absence
of any polarization is consistent with the interpretation of the excess dimuons
as thermal radiation from a randomized system.
-
The NA60 experiment at the CERN SPS has measured muon pairs with
unprecedented precision in 158A GeV In-In collisions. A strong excess of pairs
above the known sources is observed in the whole mass region 0.2<M<2.6 GeV. The
mass spectrum for M<1 GeV is consistent with a dominant contribution from
pi+pi- -> rho -> mu+mu- annihilation. The associated rho spectral function
shows a strong broadening, but essentially no shift in mass. For M>1 GeV, the
excess is found to be prompt, not due to enhanced charm production, with
pronounced differences to Drell-Yan pairs. The slope parameter Teff associated
with the transverse momentum spectra rises with mass up to the rho, followed by
a sudden decline above. The rise for M<1 GeV is consistent with radial flow of
a hadronic emission source. The seeming absence of significant flow for M>1 GeV
and its relation to parton-hadron duality is discussed in detail, suggesting a
dominantly partonic emission source in this region. A comparison of the data to
the present status of theoretical modeling is also contained. The accumulated
empirical evidence, including also a Planck-like shape of the mass spectra at
low pT and the lack of polarization, is consistent with a global interpretation
of the excess dimuons as thermal radiation. We conclude with first results on
omega in-medium effects.
-
The yield of muon pairs in the invariant mass region 1<M<2.5 GeV/c^2 produced
in heavy-ion collisions significantly exceeds the sum of the two expected
contributions, Drell-Yan dimuons and muon pairs from the decays of D meson
pairs. These sources properly account for the dimuons produced in
proton-nucleus collisions. In this paper, we show that dimuons are also
produced in excess in 158 A GeV In-In collisions. We furthermore observe, by
tagging the dimuon vertices, that this excess is not due to enhanced D meson
production, but made of prompt muon pairs, as expected from a source of thermal
dimuons specific to high-energy nucleus-nucleus collisions. The yield of this
excess increases significantly from peripheral to central collisions, both with
respect to the Drell-Yan yield and to the number of nucleons participating in
the collisions. Furthermore, the transverse mass distributions of the excess
dimuons are well described by an exponential function, with inverse slope
values around 190 MeV. The values are independent of mass and significantly
lower than those found at masses below 1 GeV/c^2, rising there up to 250 MeV
due to radial flow. This suggests the emission source of thermal dimuons above
1 GeV/c^2 to be of largely partonic origin, when radial flow has not yet built
up.
-
In this work, we have computed the three dimensional weighting potential,
field and pad response function (PRF) of typical time projection chambers (TPC)
using a recently formulated and developed boundary element method solver,
namely, the nearly exact BEM solver. A realistic geometry of the device is
found to have significant influence on the estimation of signal generation.
-
NA60 is a fixed-target experiment at the CERN SPS which measured dimuon
production in nucleus-nucleus and proton-nucleus collisions. In this paper we
report on a precision measurement of low-mass muon pairs in 158 AGeV
indium-indium collisions. A significant excess of pairs is observed above the
yield expected from neutral meson decays. The excess can be isolated by
subtraction of expected sources, thanks to the excellent mass resolution and
large sample size.