The in-beam tests of two Si pixel type TRACE detectors have been performed at
Laboratori Nazionali di Legnaro (Italy). The aim was to investigate the
possibility of identifying heavy-ion reactions products with mass A~10 at low
kinetic energy, i.e., around 10 MeV. Two separate read-out chains, digital and
analog, were used. The Pulse Shape Analysis technique was employed to obtain
the identification matrices for the digitally processed part of the data.
Separation in both charge and mass was obtained, however, the $\alpha$
particles contaminated significantly the recorded data in the lower energy
part. Due to this effect, the identification of the light products ($^{7,6}$Li
isotopes) could be possible down only to ~20 MeV
-
A study of fusion-evaporation and (partly) fusion-fission channels for the
$^{88}$Mo compound nucleus, produced at different excitation energies in the
reaction $^{48}$Ti + $^{40}$Ca at 300, 450 and 600 MeV beam energies, is
presented. Fusion-evaporation and fusion-fission cross sections have been
extracted and compared with the existing systematics. Experimental data
concerning light charged particles have been compared with the prediction of
the statistical model in its implementation in the Gemini++ code, well suited
even for high spin systems, in order to tune the main model parameters in a
mass region not abundantly covered by exclusive experimental data.
Multiplicities for light charged particles emitted in fusion evaporation events
are also presented. Some discrepancies with respect to the prediction of the
statistical model have been found for forward emitted $\alpha$-particles; they
may be due both to pre-equilibrium emission and to reaction channels (such as
Deep Inelastic Collisions, QuasiFission/QuasiFusion) different from the
compound nucleus formation.
-
The nucleosynthesis of elements beyond iron is dominated by neutron captures
in the s and r processes. However, 32 stable, proton-rich isotopes cannot be
formed during those processes, because they are shielded from the s-process
flow and r-process beta-decay chains. These nuclei are attributed to the p and
rp process.
For all those processes, current research in nuclear astrophysics addresses
the need for more precise reaction data involving radioactive isotopes.
Depending on the particular reaction, direct or inverse kinematics, forward or
time-reversed direction are investigated to determine or at least to constrain
the desired reaction cross sections.
The Facility for Antiproton and Ion Research (FAIR) will offer unique,
unprecedented opportunities to investigate many of the important reactions. The
high yield of radioactive isotopes, even far away from the valley of stability,
allows the investigation of isotopes involved in processes as exotic as the r
or rp processes.
-
The 48Ti on 40Ca reactions have been studied at 300 and 600 MeV focusing on
the fusion-evaporation (FE) and fusion-fission (FF) exit channels. Energy
spectra and multiplicities of the emitted light charged particles have been
compared to Monte Carlo simulations based on the statistical model. Indeed, in
this mass region (A about 100) models predict that shape transitions can occur
at high spin values and relatively scarce data exist in the literature about
coincidence measurements between evaporation residues and light charged
particles. Signals of shape transitions can be found in the variations of the
lineshape of high energy gamma rays emitted from the de-excitation of GDR
states gated on different region of angular momenta. For this purpose it is
important to keep under control the FE and FF processes, to regulate the
statistical model parameters and to control the onset of possible
preequilibrium emissions from 300 to 600 MeV bombarding energy.
-
The properties of large volume cylindrical 3.5 x 8 inches (89 mm x 203 mm)
LaBr3:Ce scintillation detectors coupled to the Hamamatsu R10233-100SEL
photo-multiplier tube were investigated. These crystals are among the largest
ones ever produced and still need to be fully characterized to determine how
these detectors can be utilized and in which applications. We tested the
detectors using monochromatic gamma-ray sources and in-beam reactions producing
gamma rays up to 22.6 MeV; we acquired PMT signal pulses and calculated
detector energy resolution and response linearity as a function of gamma-ray
energy. Two different voltage dividers were coupled to the Hamamatsu
R10233-100SEL PMT: the Hamamatsu E1198-26, based on straightforward resistive
network design, and the LABRVD, specifically designed for our large volume
LaBr3:Ce scintillation detectors, which also includes active semiconductor
devices. Because of the extremely high light yield of LaBr3:Ce crystals we
observed that, depending on the choice of PMT, voltage divider and applied
voltage, some significant deviation from the ideally proportional response of
the detector and some pulse shape deformation appear. In addition, crystal
non-homogeneities and PMT gain drifts affect the (measured) energy resolution
especially in case of high-energy gamma rays. We also measured the time
resolution of detectors with different sizes (from 1x1 inches up to 3.5x8
inches), correlating the results with both the intrinsic properties of PMTs and
GEANT simulations of the scintillation light collection process. The detector
absolute full energy efficiency was measured and simulated up to gamma-rays of
30 MeV
-
Gamma rays and neutrons, emitted following spontaneous fission of 252Cf, were
measured in an AGATA experiment performed at INFN Laboratori Nazionali di
Legnaro in Italy. The setup consisted of four AGATA triple cluster detectors
(12 36-fold segmented high-purity germanium crystals), placed at a distance of
50 cm from the source, and 16 HELENA BaF2 detectors. The aim of the experiment
was to study the interaction of neutrons in the segmented high-purity germanium
detectors of AGATA and to investigate the possibility to discriminate neutrons
and gamma rays with the gamma-ray tracking technique. The BaF2 detectors were
used for a time-of-flight measurement, which gave an independent discrimination
of neutrons and gamma rays and which was used to optimise the gamma-ray
tracking-based neutron rejection methods. It was found that standard gamma-ray
tracking, without any additional neutron rejection features, eliminates
effectively most of the interaction points due to recoiling Ge nuclei after
elastic scattering of neutrons. Standard tracking rejects also a significant
amount of the events due to inelastic scattering of neutrons in the germanium
crystals. Further enhancements of the neutron rejection was obtained by setting
conditions on the following quantities, which were evaluated for each event by
the tracking algorithm: energy of the first and second interaction point,
difference in the calculated incoming direction of the gamma ray,
figure-of-merit value. The experimental results of tracking with neutron
rejection agree rather well with Geant4 simulations.
-
The Advanced GAmma Tracking Array (AGATA) is a European project to develop
and operate the next generation gamma-ray spectrometer. AGATA is based on the
technique of gamma-ray energy tracking in electrically segmented high-purity
germanium crystals. This technique requires the accurate determination of the
energy, time and position of every interaction as a gamma ray deposits its
energy within the detector volume. Reconstruction of the full interaction path
results in a detector with very high efficiency and excellent spectral
response. The realization of gamma-ray tracking and AGATA is a result of many
technical advances. These include the development of encapsulated
highly-segmented germanium detectors assembled in a triple cluster detector
cryostat, an electronics system with fast digital sampling and a data
acquisition system to process the data at a high rate. The full
characterization of the crystals was measured and compared with
detector-response simulations. This enabled pulse-shape analysis algorithms, to
extract energy, time and position, to be employed. In addition, tracking
algorithms for event reconstruction were developed. The first phase of AGATA is
now complete and operational in its first physics campaign. In the future AGATA
will be moved between laboratories in Europe and operated in a series of
campaigns to take advantage of the different beams and facilities available to
maximize its science output. The paper reviews all the achievements made in the
AGATA project including all the necessary infrastructure to operate and support
the spectrometer.
-
The response of AGATA segmented HPGe detectors to gamma rays in the energy
range 2-15 MeV was measured. The 15.1 MeV gamma rays were produced using the
reaction d(11B,ng)12C at Ebeam = 19.1 MeV, while gamma-rays between 2 to 9 MeV
were produced using an Am-Be-Fe radioactive source. The energy resolution and
linearity were studied and the energy-to-pulse-height conversion resulted to be
linear within 0.05%. Experimental interaction multiplicity distributions are
discussed and compared with the results of Geant4 simulations. It is shown that
the application of gamma-ray tracking allows a suppression of background
radiation following neutron capture by Ge nuclei. Finally the Doppler
correction for the 15.1 MeV gamma line, performed using the position
information extracted with Pulse-shape Analysis, is discussed.
-
The gamma-decay of the anti-analog of the giant dipole resonance (AGDR) has
been measured to the isobaric analog state excited in the p(124Sn,n) reaction
at a beam energy of 600 MeV/nucleon. The energy of the transition was also
calculated with state-of-the-art self-consistent random-phase approximation
(RPA) and turned out to be very sensitive to the neutron-skin thickness
(\DeltaR_(pn)). By comparing the theoretical results with the measured one, the
\DeltaR_(pn) value for 124Sn was deduced to be 0.175 \pm 0.048 fm, which agrees
well with the previous results. The energy of the AGDR measured previously for
^(208)Pb was also used to determine the \DeltaR_(pn) for ^(208)Pb. In this way
a very precise \DeltaR_(pn) = 0.181 \pm 0.031 neutron-skin thickness has been
obtained for 208Pb. The present method offers new possibilities for measuring
the neutron-skin thicknesses of very exotic isotopes.
-
The gamma-rays following the reaction 105 MeV 18O + 28Si have been measured
using the EUROBALL IV, HECTOR and EUCLIDES arrays in order to investigate the
predicted Jacobi shape transition. The high-energy gamma-ray spectrum from the
GDR decay indicates a presence of large deformations in hot 46Ti nucleus, in
agreement with new theoretical calculations based on the Rotating Liquid Drop
model.