We present a study on the dependence of electric breakdown discharge
properties on electrode geometry and the breakdown field in liquid argon near
its boiling point. The measurements were performed with a spherical cathode and
a planar anode at distances ranging from 0.1 mm to 10.0 mm. A detailed study of
the time evolution of the breakdown volt-ampere characteristics was performed
for the first time. It revealed a slow streamer development phase in the
discharge. The results of a spectroscopic study of the visible light emission
of the breakdowns complement the measurements. The light emission from the
initial phase of the discharge is attributed to electro-luminescence of liquid
argon following a current of drifting electrons. These results contribute to
set benchmarks for breakdown-safe design of ionization detectors, such as
Liquid Argon Time Projection Chambers (LAr TPC).
-
ARGONTUBE is a liquid argon time projection chamber (TPC) with an electron
drift length of up to 5 m equipped with cryogenic charge-sensitive
preamplifiers. In this work, we present results on its performance including a
comparison of the new cryogenic charge-sensitive preamplifiers with the
previously used room-temperature-operated charge preamplifiers.
-
ARGONTUBE is a liquid argon time projection chamber (LAr TPC) with a drift
field generated in-situ by a Greinacher voltage multiplier circuit. We present
results on the measurement of the drift-field distribution inside ARGONTUBE
using straight ionization tracks generated by an intense UV laser beam. Our
analysis is based on a simplified model of the charging of a multi-stage
Greinacher circuit to describe the voltages on the field cage rings.
-
We present a method to reach electric field intensity as high as 400 kV/cm in
liquid argon for cathode-ground distances of several millimeters. This can be
achieved by suppressing field emission from the cathode, overcoming limitations
that we reported earlier.
-
We report on the design, construction, and operation of a PID temperature
controlled and vacuum tight camera casing. The camera casing contains a
commercial digital camera and a lighting system. The design of the camera
casing and its components are discussed in detail. Pictures taken by this
cryo-camera while immersed in argon vapour and liquid nitrogen are presented.
The cryo-camera can provide a live view inside cryogenic set-ups and allows to
record video.
-
The Liquid Argon Time Projection Chamber (LArTPC) is a prime type of detector
for future large-mass neutrino observatories and proton decay searches. In this
paper we present the design and operation, as well as experimental results from
ARGONTUBE, a LArTPC being operated at the AEC-LHEP, University of Bern. The
main goal of this detector is to prove the feasibility of charge drift over
very long distances in liquid argon. Many other aspects of the LArTPC
technology are also investigated, such as a voltage multiplier to generate high
voltage in liquid argon (Greinacher circuit), a cryogenic purification system
and the application of multi-photon ionization of liquid argon by a UV laser.
For the first time, tracks induced by cosmic muons and UV laser beam pulses
have been observed and studied at drift distances of up to 5m, the longest
reached to date.
-
A successfull application of Geiger-mode multipixel avalanche diodes (GMAPDs)
for pulse-shape discrimination in alpha-beta spectrometry using organic liquid
scintillator is described in this paper. Efficient discrimination of alpha and
beta components in the emission of radioactive isotopes is achieved for alpha
energies above 0.3 MeV. The ultra-compact design of the scintillating detector
helps to efficiently suppress cosmic-ray and ambient radiation background. This
approach allows construction of hand-held robust devices for monitoring of
radioactive contamination in various environmental conditions.
-
In this paper we describe the technology of building a vacuum-tight high
voltage feedthrough which is able to operate at voltages up to 30 kV. The
feedthrough has a coaxial structure with a grounded sheath which makes it
capable to lead high voltage potentials into cryogenic liquids, without risk of
surface discharges in the gas phase above the liquid level. The feedthrough is
designed to be used in ionization detectors, based on liquefied noble gases,
such as Argon or Xenon.
-
In this paper we report on a detailed study of ionization signals produced by
Compton electrons and alpha-particles in a Time Projection Chamber (TPC) flled
with different mixtures of liquid Argon and Nitrogen. The measurements were
carried out with Nitrogen concentrations up to 15% and a drift electric feld in
the range 0-50 kV/cm. A prediction for proton ionization signals is made by
means of interpolation. This study has been conducted in view of the possible
use of liquid Ar-N2 TPCs for the detection of gamma-rays in the resonant band
of the Nitrogen absorption spectrum, a promising technology for security and
medical applications.
-
In this paper we report on the evidence for ionization track signals from
cosmic ray muons and Compton electrons in a Time Projection Chamber (TPC)
filled with liquid Argon and doped with different fractions of Nitrogen. This
study has been conducted in view of the possible use of liquid Argon/Nitrogen
TPCs for the detection of gamma rays in the resonant band of the Nitrogen
absorbtion spectrum, a promising technology for security and medical
applications.
-
The ORPHEUS dark matter detector is operating at our underground laboratory
in Bern (70 m.w.e.). The detector relies on measuring the magnetic flux
variation produced by weakly interacting massive particles (WIMPs) as they heat
micron-sized superheated superconducting tin granules (SSG) and induce
superconducting-to-normal phase transitions. In an initial phase, 0.45 kg of
tin granules in a segmented detector volume have been used. In this paper a
general description of the experimental set-up, overall performance of the
detector, and first results are presented.
-
This work is part of an ongoing project to develop a Superheated
Superconducting Granule (SSG) detector for cold dark matter and neutrinos. The
response of SSG devices to nuclear recoils has been explored irradiating SSG
detectors with a 70MeV neutron beam. The aim of the experiment was to test the
sensitivity of Sn, Al and Zn SSG detectors to nuclear recoil energies down to a
few keV. The detector consisted of a hollow teflon cylinder (0.1cm$^3$ inner
volume) filled with tiny superconducting metastable granules embedded in a
dielectric medium. The nuclear recoil energies deposited in the SSG were
determined measuring the neutron scattering angles with a neutron hodoscope.
Coincidences in time between the SSG and the hodoscope signals have been
clearly established. In this paper the results of the neutron irradiation
experiments at different SSG intrinsic thresholds are discussed and compared to
Monte Carlo simulations. The results show that SSG are sensitive to recoil
energies down to $\sim$1keV. The limited angular resolution of the neutron
hodoscope prevented us from measuring the SSG sensitivity to even lower recoil
energies.