-
The $(x, y)$ position reconstruction method used in the analysis of the
complete exposure of the Large Underground Xenon (LUX) experiment is presented.
The algorithm is based on a statistical test that makes use of an iterative
method to recover the photomultiplier tube (PMT) light response directly from
the calibration data. The light response functions make use of a two
dimensional functional form to account for the photons reflected on the inner
walls of the detector. To increase the resolution for small pulses, a photon
counting technique was employed to describe the response of the PMTs. The
reconstruction was assessed with calibration data including
${}^{\mathrm{83m}}$Kr (releasing a total energy of 41.5 keV) and ${}^{3}$H
($\beta^-$ with Q = 18.6 keV) decays, and a deuterium-deuterium (D-D) neutron
beam (2.45 MeV). In the horizontal plane, the reconstruction has achieved an
$(x, y)$ position uncertainty of $\sigma$= 0.82 cm for events of only 200
electroluminescence photons and $\sigma$ = 0.17 cm for 4,000
electroluminescence photons. Such signals are associated with electron recoils
of energies $\sim$0.25 keV and $\sim$10 keV, respectively. The reconstructed
position of the smallest events with a single electron emitted from the liquid
surface has a horizontal $(x, y)$ uncertainty of 2.13 cm.
-
This work details the development of a three-dimensional (3D) electric field
model for the LUX detector. The detector took data during two periods of
searching for weakly interacting massive particle (WIMP) searches. After the
first period completed, a time-varying non-uniform negative charge developed in
the polytetrafluoroethylene (PTFE) panels that define the radial boundary of
the detector's active volume. This caused electric field variations in the
detector in time, depth and azimuth, generating an electrostatic
radially-inward force on electrons on their way upward to the liquid surface.
To map this behavior, 3D electric field maps of the detector's active volume
were built on a monthly basis. This was done by fitting a model built in COMSOL
Multiphysics to the uniformly distributed calibration data that were collected
on a regular basis. The modeled average PTFE charge density increased over the
course of the exposure from -3.6 to $-5.5~\mu$C/m$^2$. From our studies, we
deduce that the electric field magnitude varied while the mean value of the
field of $\sim200$~V/cm remained constant throughout the exposure. The varying
electric fields and their impact on event reconstruction and discrimination
were successfully modeled.
-
We report an absolute calibration of the ionization yields($\textit{Q$_y$})$
and fluctuations for electronic recoil events in liquid xenon at discrete
energies between 186 eV and 33.2 keV. The average electric field applied across
the liquid xenon target is 180 V/cm. The data are obtained using low energy
$^{127}$Xe electron capture decay events from the 95.0-day first run from LUX
(WS2013) in search of Weakly Interacting Massive Particles (WIMPs). The
sequence of gamma-ray and X-ray cascades associated with $^{127}$I
de-excitations produces clearly identified 2-vertex events in the LUX detector.
We observe the K- (binding energy, 33.2 keV), L- (5.2 keV), M- (1.1 keV), and
N- (186 eV) shell cascade events and verify that the relative ratio of observed
events for each shell agrees with calculations. The N-shell cascade analysis
includes single extracted electron (SE) events and represents the lowest-energy
electronic recoil $\textit{in situ}$ measurements that have been explored in
liquid xenon.
-
LUX was the first dark matter experiment to use a $^{83\textrm{m}}$Kr
calibration source. In this paper we describe the source preparation and
injection. We also present several $^{83\textrm{m}}$Kr calibration applications
in the context of the 2013 LUX exposure, including the measurement of temporal
and spatial variation in scintillation and charge signal amplitudes, and
several methods to understand the electric field within the time projection
chamber.
-
We present experimental constraints on the spin-dependent WIMP-nucleon
elastic cross sections from the total 129.5 kg-year exposure acquired by the
Large Underground Xenon experiment (LUX), operating at the Sanford Underground
Research Facility in Lead, South Dakota (USA). A profile likelihood ratio
analysis allows 90% CL upper limits to be set on the WIMP-neutron (WIMP-proton)
cross section of $\sigma_n$ = 1.6$\times 10^{-41}$ cm$^{2}$ ($\sigma_p$ =
5$\times 10^{-40}$ cm$^{2}$) at 35 GeV$c^{-2}$, almost a sixfold improvement
over the previous LUX spin-dependent results. The spin-dependent WIMP-neutron
limit is the most sensitive constraint to date.
-
We report constraints on spin-independent weakly interacting massive particle
(WIMP)-nucleon scattering using a 3.35e4 kg-day exposure of the Large
Underground Xenon (LUX) experiment. A dual-phase xenon time projection chamber
with 250 kg of active mass is operated at the Sanford Underground Research
Facility under Lead, South Dakota (USA). With roughly fourfold improvement in
sensitivity for high WIMP masses relative to our previous results, this search
yields no evidence of WIMP nuclear recoils. At a WIMP mass of 50 GeV/c^2,
WIMP-nucleon spin-independent cross sections above 2.2e-46 cm^2 are excluded at
the 90% confidence level. When combined with the previously reported LUX
exposure, this exclusion strengthens to 1.1e-46 cm^2 at 50 GeV/c^2.
-
The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon
time projection chamber (TPC) operating at the Sanford Underground Research
Facility in Lead, South Dakota. A calibration of nuclear recoils in liquid
xenon was performed $\textit{in situ}$ in the LUX detector using a collimated
beam of mono-energetic 2.45 MeV neutrons produced by a deuterium-deuterium
(D-D) fusion source. The nuclear recoil energy from the first neutron scatter
in the TPC was reconstructed using the measured scattering angle defined by
double-scatter neutron events within the active xenon volume. We measured the
absolute charge ($Q_{y}$) and light ($L_{y}$) yields at an average electric
field of 180 V/cm for nuclear recoil energies spanning 0.7 to 74 keV and 1.1 to
74 keV, respectively. This calibration of the nuclear recoil signal yields will
permit the further refinement of liquid xenon nuclear recoil signal models and,
importantly for dark matter searches, clearly demonstrates measured ionization
and scintillation signals in this medium at recoil energies down to
$\mathcal{O}$(1 keV).
-
We present the first experimental constraints on the spin-dependent
WIMP-nucleon elastic cross sections from LUX data acquired in 2013. LUX is a
dual-phase xenon time projection chamber operating at the Sanford Underground
Research Facility (Lead, South Dakota), which is designed to observe the recoil
signature of galactic WIMPs scattering from xenon nuclei. A profile likelihood
ratio analysis of $1.4~\times~10^{4}~\text{kg}\cdot~\text{days}$ of fiducial
exposure allows 90% CL upper limits to be set on the WIMP-neutron (WIMP-proton)
cross section of $\sigma_n~=~9.4~\times~10^{-41}~\text{cm}^2$
($\sigma_p~=~2.9~\times~10^{-39}~\text{cm}^2$) at 33 GeV/c$^2$. The
spin-dependent WIMP-neutron limit is the most sensitive constraint to date.
-
We present constraints on weakly interacting massive particles (WIMP)-nucleus
scattering from the 2013 data of the Large Underground Xenon dark matter
experiment, including $1.4\times10^{4}\;\mathrm{kg\; day}$ of search exposure.
This new analysis incorporates several advances: single-photon calibration at
the scintillation wavelength, improved event-reconstruction algorithms, a
revised background model including events originating on the detector walls in
an enlarged fiducial volume, and new calibrations from decays of an injected
tritium $\beta$ source and from kinematically constrained nuclear recoils down
to 1.1 keV. Sensitivity, especially to low-mass WIMPs, is enhanced compared to
our previous results which modeled the signal only above a 3 keV minimum
energy. Under standard dark matter halo assumptions and in the mass range above
4 $\mathrm{GeV}\,c^{-2}$, these new results give the most stringent direct
limits on the spin-independent WIMP-nucleon cross section. The 90% C.L. upper
limit has a minimum of 0.6 zb at 33 $\mathrm{GeV}\,c^{-2}$ WIMP mass.
-
We present measurements of the electron-recoil (ER) response of the LUX dark
matter detector based upon 170,000 highly pure and spatially-uniform tritium
decays. We reconstruct the tritium energy spectrum using the combined energy
model and find good agreement with expectations. We report the average charge
and light yields of ER events in liquid xenon at 180 V/cm and 105 V/cm and
compare the results to the NEST model. We also measure the mean charge
recombination fraction and its fluctuations, and we investigate the location
and width of the LUX ER band. These results provide input to a re-analysis of
the LUX Run3 WIMP search.
-
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of
March 2015 in this Conceptual Design Report. LZ is a second-generation
dark-matter detector with the potential for unprecedented sensitivity to weakly
interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds
of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most
sensitive experiment for WIMPs in this mass region by the end of the decade.
This report describes in detail the design of the LZ technical systems.
Expected backgrounds are quantified and the performance of the experiment is
presented. The LZ detector will be located at the Sanford Underground Research
Facility in South Dakota. The organization of the LZ Project and a summary of
the expected cost and current schedule are given.