The use of Silicon Photo-Multipliers (SiPMs) has become popular in the design
of High Energy Physics experimental apparatus with a growing interest for their
application in detector area where a significant amount of non-ionising dose is
delivered. For these devices, the main effect caused by the neutron flux is a
linear increase of the leakage current. In this paper, we present a technique
that provides a partial recovery of the neutron damage on SiPMs by means of an
Electrical Induced Annealing. Tests were performed on a sample of three SiPM
arrays (2 $\times$ 3) of 6 mm$^2$ cells with 50 {\mu}m pixel sizes: two from
Hamamatsu and one from SensL. These SiPMs were irradiated up to an integrated
neutron flux up to 8 $\times$ 10$^{11}$ n$_{1MeV-eq}$/cm$^2$. Our techniques
allowed to reduced the leakage current of a factor ranging between 15-20
depending on the overbias used and the SiPM vendor.
-
The Mu2e experiment at Fermilab will search for the charged lepton flavor
violating process of neutrino-less $\mu \to e$ coherent conversion in the field
of an aluminum nucleus. Mu2e will reach a single event sensitivity of about
$2.5\cdot 10^{-17}$ that corresponds to four orders of magnitude improvements
with respect to the current best limit. The detector system consists of a straw
tube tracker and a crystal calorimeter made of undoped CsI coupled with Silicon
Photomultipliers. The calorimeter was designed to be operable in a harsh
environment where about 10 krad/year will be delivered in the hottest region
and work in presence of 1 T magnetic field. The calorimeter role is to perform
$\mu$/e separation to suppress cosmic muons mimiking the signal, while
providing a high level trigger and a seeding the track search in the tracker.
In this paper we present the calorimeter design and the latest R$\&$D results.
-
In this paper, we report the measurement of the neutron radiation hardness of
custom Silicon Photomultipliers arrays (SiPMs) manufactured by three companies:
Hamamatsu (Japan), AdvanSiD (Italy) and SensL (Ireland). These custom SiPMs
consist of a 2 x 3 array of 6 x 6 mm^2 monolithic cells with pixel sizes of
respectively 50 um (Hamamatsu and SensL) and 30 um (AdvanSid).
A sample from each vendor has been exposed to neutrons generated by the Elbe
Positron Source facility (Dresden), up to a total fluence of ~ 8.5 x 10^11 n_(1
MeV)/cm^2. Test results show that the dark current increases almost linearly
with the neutron fluence.
The room temperature annealing was quantified by measuring the dark current
two months after the irradiation test. The dependence of the dark current on
the device temperature and on the applied bias have been also evaluated.
-
The HOmogeneous Thermal NEutron Source (HOTNES) is a new type of thermal
neutron irradiation assembly developed by the ENEA-INFN collaboration. The
facility is fully characterized in terms of neutron field and dosimetric
quantities, by either computational and experimental methods. This paper
reports the results of the first "HOTNES users program", carried out in 2016,
and covering a variety of thermal neutron active detectors such as
scintillators, solid-state, single crystal diamond and gaseous detectors.
-
The Mu2e experiment is constructing a calorimeter consisting of 1,348 undoped
CsI crystals in two disks. Each crystal has a dimension of 34 x 34 x 200 mm,
and is readout by a large area silicon PMT array. A series of technical
specifications was defined according to physics requirements. Preproduction CsI
crystals were procured from three firms: Amcrys, Saint-Gobain and Shanghai
Institute of Ceramics. We report the quality assurance on crystal's
scintillation properties and their radiation hardness against ionization dose
and neutrons. With a fast decay time of 30 ns and a light output of more than
100 p.e./MeV measured with a bi-alkali PMT, undoped CsI crystals provide a
cost-effective solution for the Mu2e experiment.
-
Since the first version of the Mu2e TDR released at the beginning of 2015,
the Mu2e Calorimeter system has undergone a long list of changes to arrive to
its final design. These changes were primarily caused by two reasons: (i) the
technology choice between the TDR proposed solution of BaF2 crystals readout
with solar blind Avalanche Photodiodes (APDs) and the backup option of CsI
crystals readout with Silicon Photomultipliers (SiPM) has been completed and
(ii) the channels numbering, the mechanical system and the readout electronics
were substantially modified while proceeding with engineering towards the final
project. This document updates the description of the calorimeter system adding
the most recent engineering drawings and tecnical progresses.
-
We propose an evolution of the Mu2e experiment, called Mu2e-II, that would
leverage advances in detector technology and utilize the increased proton
intensity provided by the Fermilab PIP-II upgrade to improve the sensitivity
for neutrinoless muon-to-electron conversion by one order of magnitude beyond
the Mu2e experiment, providing the deepest probe of charged lepton flavor
violation in the foreseeable future. Mu2e-II will use as much of the Mu2e
infrastructure as possible, providing, where required, improvements to the Mu2e
apparatus to accommodate the increased beam intensity and cope with the
accompanying increase in backgrounds.
-
The Mu2e Experiment at Fermilab will search for coherent, neutrino-less
conversion of negative muons into electrons in the field of an Aluminum
nucleus, $\mu^- + Al \to e^- +Al$. Data collection start is planned for the end
of 2021.
The dynamics of such charged lepton flavour violating (CLFV) process is well
modelled by a two-body decay, resulting in a mono-energetic electron with an
energy slightly below the muon rest mass. If no events are observed in three
years of running, Mu2e will set an upper limit on the ratio between the
conversion and the capture rates
%\convrate of $\leq 6\ \times\ 10^{-17}$ (@ 90$\%$ C.L.). R$_{\mu e} =
\frac{\mu^- + A(Z,N) \to e^- +A(Z,N)}{\mu^- + A(Z,N) \to \nu_{\mu} ^-
+A(Z-1,N)} $ of $\leq 6\ \times\ 10^{-17}$ (@ 90$\%$ C.L.).
This will improve the current limit of four order of magnitudes with respect
to the previous best experiment.
Mu2e complements and extends the current search for $\mu \to e \gamma$ decay
at MEG as well as the direct searches for new physics at the LHC. The
observation of such CLFV process could be clear evidence for New Physics beyond
the Standard Model. Given its sensitivity, Mu2e will be able to probe New
Physics at a scale inaccessible to direct searches at either present or planned
high energy colliders. To search for the muon conversion process, a very
intense pulsed beam of negative muons ($\sim 10^{10} \mu/$ sec) is stopped on
an Aluminum target inside a very long solenoid where the detector is also
located. The Mu2e detector is composed of a straw tube tracker and a CsI
crystals electromagnetic calorimeter. An overview of the physics motivations
for Mu2e, the current status of the experiment and the required performances
and design details of the calorimeter are presented.
-
We have measured the running of the effective QED coupling constant
$\alpha(s)$ in the time-like region $0.6<\sqrt s< 0.975$ GeV with the KLOE
detector at DA$\Phi$NE using the Initial State Radiation process
$e^+e^-\to\mu^+ \mu^-\gamma$. It represents the first measurement of the
running of $\alpha(s)$ in this energy region. Our results show a more than
5$\sigma$ significance of the hadronic contribution to the running of
$\alpha(s)$, which is the strongest direct evidence both in time- and
space-like regions achieved in a single measurement. By using the
$e^+e^-\to\pi^+\pi^-$ cross section measured by KLOE, the real and imaginary
part of the shift $\Delta\alpha(s)$ has been extracted. By a fit of the real
part of $\Delta\alpha(s)$ and assuming the lepton universality the branching
ratio $BR(\omega\to\mu^+\mu^-) = (6.6\pm1.4_{stat}\pm1.7_{syst})\cdot 10^{-5} $
has been determined.
-
This paper describes the measurements of energy and time response and
resolution of a 3 x 3 array made of undoped CsI crystals coupled to large area
Hamamatsu Multi Pixel Photon Counters. The measurements have been performed
using the electron beam of the Beam Test Facility in Frascati (Rome, Italy) in
the energy range 80-120 MeV. The measured energy resolution, estimated with the
FWHM, at 100 MeV is 16.4%. This resolution is dominated by the energy leakage
due to the small dimensions of the prototype. The time is reconstructed by
fitting the leading edge of the digitized signals and applying a digital
constant fraction discrimination technique. A time resolution of about 110 ps
at 100 MeV is achieved.
-
The Mu2e experiment at Fermilab looks for Charged Lepton Flavor Violation
(CLFV) improving by 4 orders of magnitude the current experimental sensitivity
for the muon to electron conversion in a muonic atom. A positive signal could
not be explained in the framework of the current Standard Model of particle
interactions and therefore would be a clear indication of new physics. In 3
years of data taking, Mu2e is expected to observe less than one background
event mimicking the electron coming from muon conversion. Achieving such a
level of background suppression requires a deep knowledge of the experimental
apparatus: a straw tube tracker, measuring the electron momentum and time, a
cosmic ray veto system rejecting most of cosmic ray background and a pure CsI
crystal calorimeter, that will measure time of flight, energy and impact
position of the converted electron. The calorimeter has to operate in a harsh
radiation environment, in a 10-4 Torr vacuum and inside a 1 T magnetic field.
The results of the first qualification tests of the calorimeter components are
reported together with the energy and time performances expected from the
simulation and measured in beam tests of a small scale prototype.
-
The Mu2e calorimeter is composed of 1400 un-doped CsI crystals, coupled to
large area UV extended Silicon Photomultipliers (SiPMs), arranged in two
annular disks. This calorimeter has to provide precise information on energy,
timing and position resolutions. It should also be fast enough to handle the
high rate background and it must operate and survive in the high radiation
environment. Simulation studies estimated that, in the highest irradiated
regions, each photo-sensor will absorb a dose of 20 krad and will be exposed to
a neutron fluency of 5.5x10^11 n_(1MeV)/cm^2 in three years of running, with a
safety factor of 3 included. At the end of 2015, we have concluded an
irradiation campaign at the Frascati Neutron Generator (FNG, Frascati, Italy)
measuring the response of two different 16 array models from Hamamatsu, which
differ for the protection windows and a SiPM from FBK. In 2016, we have carried
out two additional irradiation campaigns with neutrons and photons at the
Helmholtz-Zentrum Dresden-Rossendorf (HZDR, Dresden, Germany) and at the
Calliope gamma irradiation facility at ENEA-Casaccia, respectively. A
negligible increment of the leakage current and no gain change have been
observed with the dose irradiation. On the other hand, at the end of the
neutron irradiation, the gain does not show large changes whilst the leakage
current increases by around a factor of 2000. In these conditions, the too high
leakage current makes problematic to bias the SiPMs, thus requiring to cool
them down to a running temperature of ~0 {\deg}C.
-
The Mu2e experiment at Fermilab aims at measuring the neutrinoless conversion
of a negative muon into an electron and reach a single event sensitivity of
2.5x10^{-17} after three years of data taking. The monoenergetic electron
produced in the final state, is detected by a high precision tracker and a
crystal calorimeter, all embedded in a large superconducting solenoid (SD)
surrounded by a cosmic ray veto system. The calorimeter is complementary to the
tracker, allowing an independent trigger and powerful particle identification,
while seeding the track reconstruction and contributing to remove background
tracks mimicking the signal. In order to match these requirements, the
calorimeter should have an energy resolution of O(5)% and a time resolution
better than 500 ps at 100 MeV. The baseline solution is a calorimeter composed
of two disks of BaF2 crystals read by UV extended, solar blind, Avalanche
Photodiode (APDs), which are under development from a JPL, Caltech, RMD
consortium. In this paper, the calorimeter design, the R&D studies carried out
so far and the status of engineering are described. A backup alternative setup
consisting of a pure CsI crystal matrix read by UV extended Hamamatsu MPPC's is
also presented.
-
The Mu2e experiment at Fermilab searches for the charged-lepton flavor
violating neutrino-less conversion of a negative muon into an electron in the
field of a aluminum nucleus. The dynamic of such a process is well modeled by a
two-body decay, resulting in a monoenergetic electron with an energy slightly
below the muon rest mass (104.967 MeV). The calorimeter of this experiment
plays an important role to provide excellent particle identification
capabilities and an online trigger filter while aiding the track reconstruction
capabilities. The baseline calorimeter configuration consists of two disks each
made with about 700 undoped CsI crystals read out by two large area UV-extended
Silicon Photomultipliers. These crystals match the requirements for stability
of response, high resolution and radiation hardness. In this paper we present
the final calorimeter design.
-
To study an alternative to BaF2, as the crystal choice for the Mu2e
calorimeter, thirteen pure CsI crystals from Opto Materials and ISMA producers
have been characterized by determining their light yield (LY) and longitudinal
response uniformity (LRU), when read with a UV extended PMT. The crystals show
a LY of ~ 100 p.e./MeV (~ 150 p.e./MeV) when wrapped with Tyvek and coupled to
the PMT without (with) optical grease. The LRU is well represented by a linear
slope that is on average around -0.6 %/cm. The timing performances of the Opto
Materials crystal, read with a UV extended MPPC, have been evaluated with
minimum ionizing particles. A timing resolution of ~ 330 ps (~ 440 ps) is
achieved when connecting the photosensor to the MPPC with (without) optical
grease. The crystal radiation hardness to a ionization dose has also been
studied for one pure CsI crystal from SICCAS. After exposing it to a dose of
900 Gy, a decrease of 33% in the LY is observed while the LRU remains
unchanged.
-
A measurement of the vector to pseudoscalar conversion decay $\phi \to \pi^0
e^+e^-$ with the KLOE experiment is presented. A sample of $\sim 9500$ signal
events was selected from a data set of 1.7 fb$^{-1}$ of $e^+e^-$ collisions at
$\sqrt{s} \sim m_{\phi}$ collected at the DA$\Phi$NE $e^+e^-$ collider. These
events were used to obtain the first measurement of the transition form factor
$| F_{\phi \pi^0}(q^2) |$ and a new measurement of the branching ratio of the
decay: $\rm{BR}\,(\phi \to \pi^0 e^+e^-) = (\,1.35 \pm
0.05^{\,\,+0.05}_{\,\,-0.10}\,) \times 10 ^{-5}$. The result improves
significantly on previous measurements and is in agreement with theoretical
predictions.
-
We have measured the performances of a LYSO crystal matrix prototype tested
with electron and photon beams in the energy range 60$-$450 MeV. This study has
been carried out to determine the achievable energy and time resolutions for
the calorimeter of the Mu2e experiment.
-
The recent interest in a light gauge boson in the framework of an extra U(1)
symmetry motivates searches in the mass range below 1 GeV.
We present a search for such a particle, the dark photon, in ${\rm e^+
e^-}\rightarrow {\rm U}\gamma$, U$\rightarrow \pi^+\pi^-$ based on 28 million
$\mathrm{e^+ e^-} \rightarrow \pi^+ \pi^-\gamma$ events collected at DA$\Phi$NE
by the KLOE experiment. The $\pi^+ \pi^-$ production by initial-state radiation
compensates for a loss of sensitivity of previous KLOE ${\rm U} \rightarrow
\mathrm{e^+ e^-}$, $\mu^+\mu^-$ searches due to the small branching ratios in
the $\rho-\omega$ resonance region. We found no evidence for a signal and set a
limit at 90\% CL on the mixing strength between the photon and the dark photon,
$\varepsilon^2$, in the U mass range between $527$ and $987$~MeV. Above 700 MeV
this new limit is more stringent than previous ones.
-
Using $1.6$ fb$^{-1}$ of $e^+ e^-\to\phi\to\eta\gamma$ data collected with
the KLOE detector at DA$\Phi$NE, the Dalitz plot distribution for the $\eta \to
\pi^+ \pi^- \pi^0$ decay is studied with the world's largest sample of $\sim
4.7 \cdot 10^6$ events. The Dalitz plot density is parametrized as a polynomial
expansion up to cubic terms in the normalized dimensionless variables $X$ and
$Y$. The experiment is sensitive to all charge conjugation conserving terms of
the expansion, including a $gX^2Y$ term. The statistical uncertainty of all
parameters is improved by a factor two with respect to earlier measurements.
-
In this paper we present the time resolution measurements of the
Lutetium-Yttrium Oxyorthosilicate (LYSO) calorimeter prototype for the Mu2e
experiment. The measurements have been performed using the $e^-$ beam of the
Beam Test Facility (BTF) in Frascati, Italy in the energy range from 100 to 400
MeV. The calorimeter prototype consisted of twenty five 30x30x130 mm$^3$, LYSO
crystals read out by 10x10 mm$^2$ Hamamatsu Avalanche Photodiodes (APDs). The
energy dependence of the measured time resolution can be parametrized as
$\sigma_{t}(E)=a/\sqrt{E/\mathrm{GeV}} \oplus b$, with the stochastic and
constant terms $a=(51\pm1)$ ps and $b=(10\pm4)$ ps, respectively. This
corresponds to the time resolution of ($162\pm4$) ps at 100 MeV.
-
The existence of a new force beyond the Standard Model is compelling because
it could explain several striking astrophysical observations which fail
standard interpretations. We searched for the light vector mediator of this
dark force, the $\mathrm{U}$ boson, with the KLOE detector at the DA$\Phi$NE
$\mathrm{e}^{+}\mathrm{e}^{-}$ collider. Using an integrated luminosity of 1.54
fb$^{-1}$, we studied the process $\mathrm{e}^{+}\mathrm{e}^{-} \to
\mathrm{U}\gamma$, with $\mathrm{U} \to \mathrm{e}^{+}\mathrm{e}^{-}$, using
radiative-return to search for a resonant peak in the dielectron invariant-mass
distribution. We did not find evidence for a signal, and set a 90\%~CL upper
limit on the mixing strength between the Standard Model photon and the dark
photon, $\varepsilon^2$, at $10^{-6}$--$10^{-4}$ in the 5--520~MeV/c$^2$ mass
range.
-
The Mu2e experiment at Fermilab will search for charged lepton flavor
violation via the coherent conversion process mu- N --> e- N with a sensitivity
approximately four orders of magnitude better than the current world's best
limits for this process. The experiment's sensitivity offers discovery
potential over a wide array of new physics models and probes mass scales well
beyond the reach of the LHC. We describe herein the preliminary design of the
proposed Mu2e experiment. This document was created in partial fulfillment of
the requirements necessary to obtain DOE CD-2 approval.
-
We searched for evidence of a Higgsstrahlung process in a secluded sector,
leading to a final state with a dark photon U and a dark Higgs boson h', with
the KLOE detector at DAFNE. We investigated the case of h' lighter than U, with
U decaying into a muon pair and h' producing a missing energy signature. We
found no evidence of the process and set upper limits to its parameters in the
range 2m_mu<m_U<1000 MeV, m_h'<m_U.
-
We have studied the vector to pseudoscalar conversion decay phi -> eta e+e-,
with eta -> pi0pi0pi0, with the KLOE detector at DAPHNE. The data set of 1.7
fb-1 of e+e- collisions at sqrt(s)~Mphi contains a clear conversion decay
signal of ~31,000 events from which we measured a value of BR(phi -> eta
e+e-)=(1.075+-0.007+-0.038)x10-4. The same sample is used to determine the
transition form factor by a fit to the e+e- invariant mass spectrum, obtaining
b(phi eta) =(1.17 +- 0.10 + 0.07) GeV-2, that improves by a factor of five the
precision of the previous measurement and is in good agreement with VMD
expectations.
-
We have searched for a light vector boson $U$, the possible carrier of a
"dark force", with the KLOE detector at the DA$\Phi$NE \epm\ collider,
motivated by astrophysical evidence for the presence of dark matter in the
universe. Using \epm\ collisions collected with an integrated luminosity of
$239.3$~pb$^{-1}$, we look for a dimuon mass peak in the reaction \epm\to$\mu^+
\mu^-$\gam, corresponding to the decay $U\to\mu^+\mu^-$. We find no evidence
for a $U$ vector boson signal. We set a 90\% CL upper limit for the mixing
parameter squared between the photon and the $U$ boson of 1.6$\times$10$^{-5}$
to 8.6$\times$10$^{-7}$ for the mass region $520<m_{\rm U}<980$ MeV.