Expulsion of ambient flux has been shown to be crucial to obtain high quality
factors in bulk niobium SRF cavities. However, there remain many questions as
to what properties of the niobium material determine its flux expulsion
behavior. In this paper, we present first results from a new study of two
cavities that were specially fabricated to study flux expulsion. Both cavities
were made from large grain ingot niobium slices, one of which had its slices
rolled prior to fabrication, and none these slices were annealed prior to
measurement. Expulsion measurements indicate that a dense network of grain
boundaries is not necessary for a cavity to have near-complete flux trapping
behavior up to large thermal gradients. The results also contribute to a body
of evidence that cold work is a strong determinant of flux expulsion behavior
in SRF-grade niobium.
-
The radio-frequency surface resistance of niobium resonators is incredibly
reduced when nitrogen impurities are dissolved as interstitial in the material,
conferring ultra-high Q-factors at medium values of accelerating field. This
effect has been observed in both high and low temperature nitrogen treatments.
As a matter of fact, the peculiar anti Q-slope observed in nitrogen doped
cavities, i.e. the decreasing of the Q-factor with the increasing of the
radio-frequency field, come from the decreasing of the BCS surface resistance
component as a function of the field. Such peculiar behavior has been
considered consequence of the interstitial nitrogen present in the niobium
lattice after the doping treatment. The study here presented show the field
dependence of the BCS surface resistance of cavities with different resonant
frequencies, such as: 650 MHz, 1.3 GHz, 2.6 GHz and 3.9 GHz, and processed with
different state-of-the-art surface treatments. These findings show for the
first time that the anti Q-slope might be seen at high frequency even for clean
Niobium cavities, revealing useful suggestion on the physics underneath the
anti Q-slope effect.
-
Nb$_3$Sn has great potential to become the material of choice for fabrication
of SRF cavities. The higher critical temperature of Nb$_3$Sn potentially allows
for an increased operational temperature in SRF cavities, which could enable
tremendous simplification of cryogenic system, leading to significant cost
reduction. We present extended characterization of a Nb$_3$Sn coated Nb cavity
prepared at Cornell University. Using combination of thermometry during cavity
RF measurements, and structural and analytical characterization of the cavity
cutouts, we discover Nb$_3$Sn coating flaws responsible for the poor cavity
performance. Our results clearly show degraded material quality in the cavity
cutouts which exhibit significant heating during the RF testing. Results of
extended comparison of cavity cutouts with different dissipation profiles not
only point out the cause of significant Q-slope but also establish figures of
merit for material qualities in relation to the quality of SRF performance.
-
We report the finding of new surface treatments that permit to manipulate the
niobium resonator nitrogen content in the first few nanometers in a controlled
way, and the resonator fundamental Mattis-Bardeen surface resistance and
residual resistance accordingly. In particular, we find surface infusion
conditions that systematically a) increase the quality factor of these 1.3 GHz
superconducting radio frequency (SRF) bulk niobium resonators, up to very high
gradients; b) increase the achievable accelerating gradient of the cavity
compared to its own baseline with state-of-the-art surface processing. Cavities
subject to the new surface process have larger than two times the state of the
art Q at 2K for accelerating fields > 35 MV/m. Moreover, very high accelerating
gradients ~ 45 MV/m are repeatedly reached, which correspond to peak magnetic
surface fields of 190 mT, among the highest measured for bulk niobium cavities.
These findings open the opportunity to tailor the surface impurity content
distribution to maximize performance in Q and gradients, and have therefore
very important implications on future performance and cost of SRF based
accelerators. They also help deepen the understanding of the physics of the RF
niobium cavity surface.
-
Previous work has demonstrated that the radio frequency surface resistance of
niobium resonators is dramatically reduced when nitrogen impurities are
dissolved as interstitial in the material. The origin of this effect is
attributed to the lowering of the Mattis and Bardeen surface resistance
contribution with increasing accelerating field. Meanwhile, an enhancement of
the sensitivity to trapped magnetic field is typically observed for such
cavities. In this paper we conduct the first systematic study on these
different components contributing to the total surface resistance as a function
of different levels of dissolved nitrogen, in comparison with standard surface
treatments for niobium resonators. Adding these results together we are able to
show for the first time which is the optimum surface treatment that maximizes
the Q-factor of superconducting niobium resonators as a function of expected
trapped magnetic field in the cavity walls. These results also provide new
insights on the physics behind the change in the field dependence of the Mattis
and Bardeen surface resistance, and of the trapped magnetic vortex induced
losses in superconducting niobium resonators.
-
Quench of superconducting radio-frequency cavities frequently leads to the
lowered quality factor Q0, which had been attributed to the additional trapped
magnetic flux. Here we demonstrate that the origin of this magnetic flux is
purely extrinsic to the cavity by showing no extra dissipation (unchanged Q0)
after quenching in zero magnetic field, which allows us to rule out intrinsic
mechanisms of flux trapping such as generation of thermal currents or trapping
of the rf field. We also show the clear relation of dissipation introduced by
quenching to the orientation of the applied magnetic field and the possibility
to fully recover the quality factor by requenching in the compensated field. We
discover that for larger values of the ambient field, the Q-factor degradation
may become irreversible by this technique, likely due to the outward flux
migration beyond the normal zone opening during quench. Our findings are of
special practical importance for accelerators based on low- and medium-beta
accelerating structures residing close to focusing magnets, as well as for all
high-Q cavity-based accelerators.
-
Even when cooled through its transition temperature in the presence of an
external magnetic field, a superconductor can expel nearly all external
magnetic flux. This Letter presents an experimental study to identify the
parameters that most strongly influence flux trapping in high purity niobium
during cooldown. This is critical to the operation of superconducting
radiofrequency cavities, in which trapped flux degrades the quality factor and
therefore cryogenic efficiency. Flux expulsion was measured on a large survey
of 1.3 GHz cavities prepared in various ways. It is shown that both spatial
thermal gradient and high temperature treatment are critical to expelling
external magnetic fields, while surface treatment has minimal effect. For the
first time, it is shown that a cavity can be converted from poor expulsion
behavior to strong expulsion behavior after furnace treatment, resulting in a
substantial improvement in quality factor. Future plans are described to build
on this result in order to optimize treatment for future cavities.
-
A Temperature mapping (T-map) system for Superconducting Radio Frequency
(SRF) cavities consists of a thermometer array positioned precisely on an
exterior cavity wall, capable of detecting small increases in temperature;
therefore it is a powerful tool for research on the quality factor (Q0) of SRF
cavities. A new multi-cell T-mapping system is has been developed at Cornell
University. The system has nearly two thousand thermometers to cover 7-cell SRF
cavities for Cornell ERL project. A new multiplexing scheme was adopted to
reduce number of wires. A 1mK resolution of the temperature increase Delta T is
achieved. A 9-cell cavity of TESLA geometry was tested with the T-map system.
By converting Delta T to power loss and quality factor, it has been found that
for this cavity, most surface losses were generated by the first cell when the
accelerating gradient is increased above 15MV/m. The comparison of Q-value
between with and without hotspots shows the heating on cavity wall degraded
cavity Q0 about 1.65 times. The power loss on the hotspots is about 40% of the
total power. Effective and intuitive ways of displaying surface properties of
the cavity interior, e.g. the residual resistivity, will be shown.
-
Over the past years it became evident that the quality factor of a
superconducting cavity is not only determined by its surface preparation
procedure, but is also influenced by the way the cavity is cooled down.
Moreover, different data sets exists, some of them indicate that a slow
cool-down through the critical temperature is favourable while other data
states the exact opposite. Even so there where speculations and some models
about the role of thermo-currents and flux-pinning, the difference in behaviour
remained a mystery. In this paper we will for the first time present a
consistent theoretical model which we confirmed by data that describes the role
of thermo-currents, driven by temperature gradients and material transitions.
We will clearly show how they impact the quality factor of a cavity, discuss
our findings, relate it to findings at other labs and develop mitigation
strategies which especially addresses the issue of achieving high quality
factors of so-called nitrogen doped cavities in horizontal test.