• The Ultra-Violet Imaging Telescope (UVIT) is one of the payloads in ASTROSAT, the first Indian Space Observatory. The UVIT instrument has two 375mm telescopes: one for the far-ultraviolet (FUV) channel (1300--1800\AA), and the other for the near-ultraviolet (NUV) channel (2000--3000\AA) and the visible (VIS) channel (3200--5500\AA). UVIT is primarily designed for simultaneous imaging in the two ultraviolet channels with spatial resolution better than 1.8 arcsec, along with provision for slit-less spectroscopy in the NUV and FUV channels.The results of in-orbit calibrations of UVIT are presented in this paper.
  • A fiber-fed Echelle spectrograph at 2.3 m Vainu Bappu Telescope (VBT), Kavalur, has been in operation since 2005. Owing to various technological advancements in precision spectroscopy in recent years, several research avenues have been opened in observational astronomy. These developments have created a demand to improve the Doppler precision of our spectrograph. Currently, the stability of the instrument is compromised by the temperature and pressure fluctuations inside the Echelle room. Further, a better wavelength calibration approach is needed to carefully track and disentangle the instrumental effects from stellar spectra. While planning a possible upgrade with an Iodine absorption gas cell, we measured the raw stability of the spectrograph using a series of calibration frames taken with the ThAr gas discharge lamp. The time series data were analysed with cross-correlation method and the shift in ThAr emission lines was accurately measured across different Echelle orders. In this paper, we present our stability analysis methodology and results for the Kavalur spectrograph. We also identify possible sources of error and discuss our strategy to mitigate them.
  • Ultraviolet Imaging Telescope (UVIT) is one of the payloads onboard AstroSat, India's first multi-wavelength Astronomy mission. UVIT is primarily designed to make high resolution images in wide field, in three wavelength channels simultaneously: FUV (130 - 180 nm), NUV (200 - 300 nm) and VIS (320 - 550 nm). The intensified imagers used in UVIT suffer from distortions, and a correction is necessary for these to achieve good astrometry. In this article we describe the methodology and calculations used to estimate the distortions in ground calibrations.
  • The performance of the ultraviolet telescope (UVIT) on-board ASTROSAT is reported. The performance in orbit is also compared with estimates made from the calibrations done on the ground. The sensitivity is found to be within ~15% of the estimates, and the spatial resolution in the NUV is found to exceed significantly the design value of 1.8 arcsec and it is marginally better in the FUV. Images obtained from UVIT are presented to illustrate the details revealed by the high spatial resolution. The potential of multi-band observations in the ultraviolet with high spatial resolution is illustrated by some results.
  • We present the in-orbit performance and the first results from the ultra-violet Imaging telescope (UVIT) on ASTROSAT. UVIT consists of two identical 38cm coaligned telescopes, one for the FUV channel (130-180nm) and the other for the NUV (200-300nm) and VIS (320-550nm) channels, with a field of view of 28 $arcmin$. The FUV and the NUV detectors are operated in the high gain photon counting mode whereas the VIS detector is operated in the low gain integration mode. The FUV and NUV channels have filters and gratings, whereas the VIS channel has filters. The ASTROSAT was launched on 28th September 2015. The performance verification of UVIT was carried out after the opening of the UVIT doors on 30th November 2015, till the end of March 2016 within the allotted time of 50 days for calibration. All the on-board systems were found to be working satisfactorily. During the PV phase, the UVIT observed several calibration sources to characterise the instrument and a few objects to demonstrate the capability of the UVIT. The resolution of the UVIT was found to be about 1.4 - 1.7 $arcsec$ in the FUV and NUV. The sensitivity in various filters were calibrated using standard stars (white dwarfs), to estimate the zero-point magnitudes as well as the flux conversion factor. The gratings were also calibrated to estimate their resolution as well as effective area. The sensitivity of the filters were found to be reduced up to 15\% with respect to the ground calibrations. The sensitivity variation is monitored on a monthly basis. UVIT is all set to roll out science results with its imaging capability with good resolution and large field of view, capability to sample the UV spectral region using different filters and capability to perform variability studies in the UV.