• Login
    Sort by: Relevance Date Users's collections Twitter
    Group by: Day Week Month Year All time
Based on the idea and the provided source code of Andrej Karpathy (arxiv-sanity)
2:3 1:1 3:2
  • Prime Focus Spectrograph (PFS) for the Subaru Telescope: Overview, recent progress, and future perspectives (1608.01075)

    Naoyuki Tamura, Naruhisa Takato, Atsushi Shimono, Yuki Moritani, Kiyoto Yabe, Yuki Ishizuka, Akitoshi Ueda, Yukiko Kamata, Hrand Aghazarian, Stephane Arnouts, Gabriel Barban, Robert H. Barkhouser, Renato C. Borges, David F. Braun, Michael A. Carr, Pierre-Yves Chabaud, Yin-Chang Chang, Hsin-Yo Chen, Masashi Chiba, Richard C. Y. Chou, You-Hua Chu, Judith G. Cohen, Rodrigo P. de Almeida, Antonio C. de Oliveira, Ligia S. de Oliveira, Richard G. Dekany, Kjetil Dohlen, Jesulino B. dos Santos, Leandro H. dos Santos, Richard S. Ellis, Maximilian Fabricius, Didier Ferrand, Decio Ferreira, Mirek Golebiowski, Jenny E. Greene, Johannes Gross, James E. Gunn, Randolph Hammond, Albert Harding, Murdock Hart, Timothy M. Heckman, Christopher M. Hirata, Paul Ho, Stephen C. Hope, Larry Hovland, Shu-Fu Hsu, Yen-Shan Hu, Ping-Jie Huang, Marc Jaquet, Yipeng Jing, Jennifer Karr, Masahiko Kimura, Matthew E. King, Eiichiro Komatsu, Vincent Le Brun, Olivier Le Fevre, Arnaud Le Fur, David Le Mignant, Hung-Hsu Ling, Craig P. Loomis, Robert H. Lupton, Fabrice Madec, Peter Mao, Lucas S. Marrara, Claudia Mendes de Oliveira, Yosuke Minowa, Chaz N. Morantz, Hitoshi Murayama, Graham J. Murray, Youichi Ohyama, Joseph Orndorff, Sandrine Pascal, Jefferson M. Pereira, Daniel J. Reiley, Martin Reinecke, Andreas Ritter, Mitsuko Roberts, Mark A. Schwochert, Michael D. Seiffert, Stephen A. Smee, Laerte Sodre Jr., David N. Spergel, Aaron J. Steinkraus, Michael A. Strauss, Christian Surace, Yasushi Suto, Nao Suzuki, John Swinbank, Philip J. Tait, Masahiro Takada, Tomonori Tamura, Yoko Tanaka, Laurence Tresse, Orlando Verducci Jr., Didier Vibert, Clement Vidal, Shiang-Yu Wang, Chih-Yi Wen, Chi-Hung Yan, Naoki Yasuda
    Aug. 3, 2016 astro-ph.CO, astro-ph.GA, astro-ph.IM
    ... ... ... ... ... ...
    PFS (Prime Focus Spectrograph), a next generation facility instrument on the 8.2-meter Subaru Telescope, is a very wide-field, massively multiplexed, optical and near-infrared spectrograph. Exploiting the Subaru prime focus, 2394 reconfigurable fibers will be distributed over the 1.3 deg field of view. The spectrograph has been designed with 3 arms of blue, red, and near-infrared cameras to simultaneously observe spectra from 380nm to 1260nm in one exposure at a resolution of ~1.6-2.7A. An international collaboration is developing this instrument under the initiative of Kavli IPMU. The project is now going into the construction phase aiming at undertaking system integration in 2017-2018 and subsequently carrying out engineering operations in 2018-2019. This article gives an overview of the instrument, current project status and future paths forward.
  • Visible camera cryostat design and performance for the SuMIRe Prime Focus Spectrograph (PFS) (1608.01196)

    Stephen A. Smee, James E. Gunn, Mirek Golebiowski, Stephen C. Hope, Fabrice Madec, Jean-Francois Gabriel, Craig Loomis, Arnaud Le Fur, Kjetil Dohlen, David Le Mignant, Robert Barkhouser, Michael Carr, Murdock Hart, Naoyuki Tamura, Atsushi Shimono, Naruhisa Takato
    Aug. 3, 2016 physics.ins-det, astro-ph.IM
    ... ... ... ... ... ...
    We describe the design and performance of the SuMIRe Prime Focus Spectrograph (PFS) visible camera cryostats. SuMIRe PFS is a massively multi-plexed ground-based spectrograph consisting of four identical spectrograph modules, each receiving roughly 600 fibers from a 2394 fiber robotic positioner at the prime focus. Each spectrograph module has three channels covering wavelength ranges 380~nm -- 640~nm, 640~nm -- 955~nm, and 955~nm -- 1.26~um, with the dispersed light being imaged in each channel by a f/1.07 vacuum Schmidt camera. The cameras are very large, having a clear aperture of 300~mm at the entrance window, and a mass of $\sim$280~kg. In this paper we describe the design of the visible camera cryostats and discuss various aspects of cryostat performance.
  • CCD Readout Electronics for the Subaru Prime Focus Spectrograph (1408.3401)

    Stephen C. Hope, James E. Gunn, Craig P. Loomis, Roger E. Fitzgerald, Grant O. Peacock
    Aug. 14, 2014 physics.ins-det, astro-ph.IM
    We present details of the design for the CCD readout electronics for the Subaru Telescope Prime Focus Spectrograph (PFS). The spectrograph is comprised of four identical spectrograph modules, each collecting roughly 600 spectra. The spectrograph modules provide simultaneous wavelength coverage over the entire band from 380 nm to 1260 nm through the use of three separate optical channels: blue, red, and near infrared (NIR). A camera in each channel images the multi-object spectra onto a 4k x 4k, 15 um pixel, detector format. The two visible cameras use a pair of Hamamatsu 2k x 4k CCDs with readout provided by custom electronics, while the NIR camera uses a single Teledyne HgCdTe 4k x 4k detector and ASIC Sidecar to read the device. The CCD readout system is a custom design comprised of three electrical subsystems: the Back End Electronics (BEE), the Front End Electronics (FEE), and a Pre-amplifier. The BEE is an off-the-shelf PC104 computer, with an auxiliary Xilinx FPGA module. The computer serves as the main interface to the Subaru messaging hub and controls other peripheral devices associated with the camera, while the FPGA is used to generate the necessary clocks and transfer image data from the CCDs. The FEE board sets clock biases, substrate bias, and CDS offsets. It also monitors bias voltages, offset voltages, power rail voltage, substrate voltage and CCD temperature. The board translates LVDS clock signals to biased clocks and returns digitized analog data via LVDS. Monitoring and control messages are sent from the BEE to the FEE using a standard serial interface. The Pre-amplifier board resides behind the detectors and acts as an interface to the two Hamamatsu CCDs. The Pre-amplifier passes clocks and biases to the CCDs, and analog CCD data is buffered and amplified prior to being returned to the FEE.
  • Focal Plane Alignment and Detector Characterization for the Subaru Prime Focus Spectrograph (1408.2822)

    Murdock Hart, Robert H. Barkhouser, Michael Carr, Mirek Golebiowski, James E. Gunn, Stephen C. Hope, Stephen A. Smee
    Aug. 12, 2014 astro-ph.IM
    ... ... ... ... ... ...
    We describe the infrastructure being developed to align and characterize the detectors for the Subaru Measurement of Images and Redshifts (SuMIRe) Prime Focus Spectrograph (PFS). PFS will employ four three-channel spectrographs with an operating wavelength range of 3800 $\AA$ to 12600 $\AA$. Each spectrograph will be comprised of two visible channels and one near infrared (NIR) channel, where each channel will use a separate Schmidt camera to image the captured spectra onto their respective detectors. In the visible channels, Hamamatsu 2k x 4k CCDs will be mounted in pairs to create a single 4k x 4k detector, while the NIR channel will use a single Teledyne 4k x 4k H4RG HgCdTe device.
  • The near infrared camera for the Subaru Prime Focus Spectrograph (1408.3284)

    Stephen A. Smee, James E. Gunn, Mirek Golebiowski, Robert Barkhouser, Sebastien Vives, Sandrine Pascal, Michael Carr, Stephen C. Hope, Craig Loomis, Murdock Hart, Hajime Sugai, Naoyuki Tamura, Atsushi Shimono
    Aug. 12, 2014 astro-ph.IM
    ... ... ... ... ... ...
    We present the detailed design of the near infrared camera for the SuMIRe (Subaru Measurement of Images and Redshifts) Prime Focus Spectrograph (PFS) being developed for the Subaru Telescope. The PFS spectrograph is designed to collect spectra from 2394 objects simultaneously, covering wavelengths that extend from 380 nm - 1.26 um. The spectrograph is comprised of four identical spectrograph modules, with each module collecting roughly 600 spectra from a robotic fiber positioner at the telescope prime focus. Each spectrograph module will have two visible channels covering wavelength ranges 380 nm - 640 nm and 640 nm - 955 nm, and one near infrared (NIR) channel with a wavelength range 955 nm - 1.26 um. Dispersed light in each channel is imaged by a 300 mm focal length, f/1.07, vacuum Schmidt camera onto a 4k x 4k, 15 um pixel, detector format. For the NIR channel a HgCdTe substrate-removed Teledyne 1.7 um cutoff device is used. In the visible channels, CCDs from Hamamatsu are used. These cameras are large, having a clear aperture of 300 mm at the entrance window, and a mass of ~ 250 kg. Like the two visible channel cameras, the NIR camera contains just four optical elements: a two-element refractive corrector, a Mangin mirror, and a field flattening lens. This simple design produces very good imaging performance considering the wide field and wavelength range, and it does so in large part due to the use of a Mangin mirror (a lens with a reflecting rear surface) for the Schmidt primary. In the case of the NIR camera, the rear reflecting surface is a dichroic, which reflects in-band wavelengths and transmits wavelengths beyond 1.26 um. This, combined with a thermal rejection filter coating on the rear surface of the second corrector element, greatly reduces the out-of-band thermal radiation that reaches the detector.