We present the first limits on inelastic electron-scattering dark matter and
dark photon absorption using a prototype SuperCDMS detector having a charge
resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device).
These electron-recoil limits significantly improve experimental constraints on
dark matter particles with masses as low as 1 MeV/$\mathrm{c^2}$. We
demonstrate a sensitivity to dark photons competitive with other leading
approaches but using substantially less exposure (0.49 gram days). These
results demonstrate the scientific potential of phonon-mediated semiconductor
detectors that are sensitive to single electronic excitations.
-
The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark
matter particles that elastically scatter from nuclei in semiconductor
detectors. The resulting nuclear-recoil energy depositions are detected by
ionization and phonon sensors. Neutrons produce a similar spectrum of
low-energy nuclear recoils in such detectors, while most other backgrounds
produce electron recoils. The absolute energy scale for nuclear recoils is
necessary to interpret results correctly. The energy scale can be determined in
CDMS II silicon detectors using neutrons incident from a broad-spectrum
$^{252}$Cf source, taking advantage of a prominent resonance in the neutron
elastic scattering cross section of silicon at a recoil (neutron) energy near
20 (182) keV. Results indicate that the phonon collection efficiency for
nuclear recoils is $4.8^{+0.7}_{-0.9}$% lower than for electron recoils of the
same energy. Comparisons of the ionization signals for nuclear recoils to those
measured previously by other groups at higher electric fields indicate that the
ionization collection efficiency for CDMS II silicon detectors operated at
$\sim$4 V/cm is consistent with 100% for nuclear recoils below 20 keV and
gradually decreases for larger energies to $\sim$75% at 100 keV. The impact of
these measurements on previously published CDMS II silicon results is small.
-
The SuperCDMS experiment is designed to directly detect weakly interacting
massive particles (WIMPs) that may constitute the dark matter in our Galaxy.
During its operation at the Soudan Underground Laboratory, germanium detectors
were run in the CDMSlite mode to gather data sets with sensitivity specifically
for WIMPs with masses ${<}$10 GeV/$c^2$. In this mode, a higher detector-bias
voltage is applied to amplify the phonon signals produced by drifting charges.
This paper presents studies of the experimental noise and its effect on the
achievable energy threshold, which is demonstrated to be as low as 56
eV$_{\text{ee}}$ (electron equivalent energy). The detector-biasing
configuration is described in detail, with analysis corrections for voltage
variations to the level of a few percent. Detailed studies of the
electric-field geometry, and the resulting successful development of a fiducial
parameter, eliminate poorly measured events, yielding an energy resolution
ranging from ${\sim}$9 eV$_{\text{ee}}$ at 0 keV to 101 eV$_{\text{ee}}$ at
${\sim}$10 eV$_{\text{ee}}$. New results are derived for astrophysical
uncertainties relevant to the WIMP-search limits, specifically examining how
they are affected by variations in the most probable WIMP velocity and the
Galactic escape velocity. These variations become more important for WIMP
masses below 10 GeV/$c^2$. Finally, new limits on spin-dependent low-mass
WIMP-nucleon interactions are derived, with new parameter space excluded for
WIMP masses $\lesssim$3 GeV/$c^2$
-
We report the result of a blinded search for Weakly Interacting Massive
Particles (WIMPs) using the majority of the SuperCDMS Soudan dataset. With an
exposure of 1690 kg days, a single candidate event is observed, consistent with
expected backgrounds. This analysis (combined with previous Ge results) sets an
upper limit on the spin-independent WIMP--nucleon cross section of $1.4 \times
10^{-44}$ ($1.0 \times 10^{-44}$) cm$^2$ at 46 GeV/$c^2$. These results set the
strongest limits for WIMP--germanium-nucleus interactions for masses $>$12
GeV/$c^2$.
-
SuperCDMS SNOLAB will be a next-generation experiment aimed at directly
detecting low-mass (< 10 GeV/c$^2$) particles that may constitute dark matter
by using cryogenic detectors of two types (HV and iZIP) and two target
materials (germanium and silicon). The experiment is being designed with an
initial sensitivity to nuclear recoil cross sections ~ 1 x 10$^{-43}$ cm$^2$
for a dark matter particle mass of 1 GeV/c$^2$, and with capacity to continue
exploration to both smaller masses and better sensitivities. The phonon
sensitivity of the HV detectors will be sufficient to detect nuclear recoils
from sub-GeV dark matter. A detailed calibration of the detector response to
low energy recoils will be needed to optimize running conditions of the HV
detectors and to interpret their data for dark matter searches. Low-activity
shielding, and the depth of SNOLAB, will reduce most backgrounds, but
cosmogenically produced $^{3}$H and naturally occurring $^{32}$Si will be
present in the detectors at some level. Even if these backgrounds are x10
higher than expected, the science reach of the HV detectors would be over three
orders of magnitude beyond current results for a dark matter mass of 1
GeV/c$^2$. The iZIP detectors are relatively insensitive to variations in
detector response and backgrounds, and will provide better sensitivity for dark
matter particle masses (> 5 GeV/c$^2$). The mix of detector types (HV and
iZIP), and targets (germanium and silicon), planned for the experiment, as well
as flexibility in how the detectors are operated, will allow us to maximize the
low-mass reach, and understand the backgrounds that the experiment will
encounter. Upgrades to the experiment, perhaps with a variety of
ultra-low-background cryogenic detectors, will extend dark matter sensitivity
down to the "neutrino floor", where coherent scatters of solar neutrinos become
a limiting background.
-
We examine the consequences of the effective field theory (EFT) of dark
matter-nucleon scattering for current and proposed direct detection
experiments. Exclusion limits on EFT coupling constants computed using the
optimum interval method are presented for SuperCDMS Soudan, CDMS II, and LUX,
and the necessity of combining results from multiple experiments in order to
determine dark matter parameters is discussed. We demonstrate that spectral
differences between the standard dark matter model and a general EFT
interaction can produce a bias when calculating exclusion limits and when
developing signal models for likelihood and machine learning techniques. We
also discuss the implications of the EFT for the next-generation (G2) direct
detection experiments and point out regions of complementarity in the EFT
parameter space.
-
The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic
germanium detectors operated at a relatively high bias voltage to amplify the
phonon signal in the search for weakly interacting massive particles (WIMPs).
Results are presented from the second CDMSlite run with an exposure of 70 kg
days, which reached an energy threshold for electron recoils as low as 56 eV. A
fiducialization cut reduces backgrounds below those previously reported by
CDMSlite. New parameter space for the WIMP-nucleon spin-independent cross
section is excluded for WIMP masses between 1.6 and 5.5 GeV/$c^2$.
-
CDMS II data from the 5-tower runs at the Soudan Underground Laboratory were
reprocessed with an improved charge-pulse fitting algorithm. Two new analysis
techniques to reject surface-event backgrounds were applied to the 612 kg days
germanium-detector WIMP-search exposure. An extended analysis was also
completed by decreasing the 10 keV analysis threshold to $\sim$5 keV, to
increase sensitivity near a WIMP mass of 8 GeV/$c^2$. After unblinding, there
were zero candidate events above a deposited energy of 10 keV and 6 events in
the lower-threshold analysis. This yielded minimum WIMP-nucleon
spin-independent scattering cross-section limits of $1.8 \times 10^{-44}$ and
$1.18 \times 10 ^{-41}$ cm$^2$ at 90\% confidence for 60 and 8.6 GeV/$c^2$
WIMPs, respectively. This improves the previous CDMS II result by a factor of
2.4 (2.7) for 60 (8.6) GeV/$c^2$ WIMPs.
-
We report a demonstration of the scalability of optically transparent xenon
in the solid phase for use as a particle detector above a kilogram scale. We
employed a cryostat cooled by liquid nitrogen combined with a xenon
purification and chiller system. A modified {\it Bridgeman's technique}
reproduces a large scale optically transparent solid xenon.
-
While the Standard Model of particle physics does not include free particles
with fractional charge, experimental searches have not ruled out their
existence. We report results from the Cryogenic Dark Matter Search (CDMS II)
experiment that give the first direct-detection limits for
cosmogenically-produced relativistic particles with electric charge lower than
$e$/6. A search for tracks in the six stacked detectors of each of two of the
CDMS II towers found no candidates, thereby excluding new parameter space for
particles with electric charges between $e$/6 and $e$/200.
-
We report a demonstration of the scalability of optically transparent xenon
in the solid phase for use as a particle detector above a kilogram scale. We
employ a liquid nitrogen cooled cryostat combined with a xenon purification and
chiller system to measure the scintillation light output and electron drift
speed from both the solid and liquid phases of xenon. Scintillation light
output from sealed radioactive sources is measured by a set of high quantum
efficiency photomultiplier tubes suitable for cryogenic applications. We
observed a reduced amount of photons in solid phase compared to that in liquid
phase. We used a conventional time projection chamber system to measure the
electron drift time in a kilogram of solid xenon and observed faster electron
drift speed in the solid phase xenon compared to that in the liquid phase.
-
We report on the results of a search for a Weakly Interacting Massive
Particle (WIMP) signal in low-energy data of the Cryogenic Dark Matter Search
(CDMS~II) experiment using a maximum likelihood analysis. A background model is
constructed using GEANT4 to simulate the surface-event background from
$^{210}$Pb decay-chain events, while using independent calibration data to
model the gamma background. Fitting this background model to the data results
in no statistically significant WIMP component. In addition, we perform fits
using an analytic ad hoc background model proposed by Collar and Fields, who
claimed to find a large excess of signal-like events in our data. We confirm
the strong preference for a signal hypothesis in their analysis under these
assumptions, but excesses are observed in both single- and multiple-scatter
events, which implies the signal is not caused by WIMPs, but rather reflects
the inadequacy of their background model.
-
A phonon and charge transport simulation based on the Geant4 Monte Carlo
toolkit is presented. The transport code is capable of propagating acoustic
phonons, electrons and holes in cryogenic crystals. Anisotropic phonon
propagation, oblique carrier propagation and phonon emission by accelerated
carriers are all taken into account. The simulation successfully reproduces
theoretical predictions and experimental observations such as phonon caustics,
heat pulse propagation times and mean carrier drift velocities.
Implementation of the transport code using the Geant4 toolkit ensures
availability to the wider scientific community.
-
We report a first search for weakly interacting massive particles (WIMPs)
using the background rejection capabilities of SuperCDMS. An exposure of 577
kg-days was analyzed for WIMPs with mass < 30 GeV/c2, with the signal region
blinded. Eleven events were observed after unblinding. We set an upper limit on
the spin-independent WIMP-nucleon cross section of 1.2e-42 cm2 at 8 GeV/c2.
This result is in tension with WIMP interpretations of recent experiments and
probes new parameter space for WIMP-nucleon scattering for WIMP masses < 6
GeV/c2.
-
SuperCDMS is an experiment designed to directly detect Weakly Interacting
Massive Particles (WIMPs), a favored candidate for dark matter ubiquitous in
the Universe. In this paper, we present WIMP-search results using a
calorimetric technique we call CDMSlite, which relies on voltage- assisted
Luke-Neganov amplification of the ionization energy deposited by particle
interactions. The data were collected with a single 0.6 kg germanium detector
running for 10 live days at the Soudan Underground Laboratory. A low energy
threshold of 170 eVee (electron equivalent) was obtained, which allows us to
constrain new WIMP-nucleon spin-independent parameter space for WIMP masses
below 6 GeV/c2.
-
As part of the Snowmass process, the Cosmic Frontier WIMP Direct Detection
subgroup (CF1) has drawn on input from the Cosmic Frontier and the broader
Particle Physics community to produce this document. The charge to CF1 was (a)
to summarize the current status and projected sensitivity of WIMP direct
detection experiments worldwide, (b) motivate WIMP dark matter searches over a
broad parameter space by examining a spectrum of WIMP models, (c) establish a
community consensus on the type of experimental program required to explore
that parameter space, and (d) identify the common infrastructure required to
practically meet those goals.
-
We report results of a search for Weakly Interacting Massive Particles
(WIMPS) with the silicon detectors of the CDMS II experiment. This blind
analysis of 140.2 kg-days of data taken between July 2007 and September 2008
revealed three WIMP-candidate events with a surface-event background estimate
of 0.41^{+0.20}_{-0.08}(stat.)^{+0.28}_{-0.24}(syst.). Other known backgrounds
from neutrons and 206Pb are limited to < 0.13 and <0.08 events at the 90%
confidence level, respectively. The exposure of this analysis is equivalent to
23.4 kg-days for a recoil energy range of 7-100 keV for a WIMP of mass 10
GeV/c2. The probability that the known backgrounds would produce three or more
events in the signal region is 5.4%. A profile likelihood ratio test of the
three events that includes the measured recoil energies gives a 0.19%
probability for the known-background-only hypothesis when tested against the
alternative WIMP+background hypothesis. The highest likelihood occurs for a
WIMP mass of 8.6 GeV/c2 and WIMP-nucleon cross section of 1.9e-41 cm2.
-
The SuperCDMS experiment in the Soudan Underground Laboratory searches for
dark matter with a 9-kg array of cryogenic germanium detectors. Symmetric
sensors on opposite sides measure both charge and phonons from each particle
interaction, providing excellent discrimination between electron and nuclear
recoils, and between surface and interior events. Surface event rejection
capabilities were tested with two $^{210}$Pb sources producing $\sim$130 beta
decays/hr. In $\sim$800 live hours, no events leaked into the 8--115 keV signal
region, giving upper limit leakage fraction $1.7 \times 10^{-5}$ at 90% C.L.,
corresponding to $< 0.6$ surface event background in the future 200-kg
SuperCDMS SNOLAB experiment.
-
We report limits on annual modulation of the low-energy event rate from the
Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground
Laboratory. Such a modulation could be produced by interactions from Weakly
Interacting Massive Particles (WIMPs) with masses ~10 GeV/c^2. We find no
evidence for annual modulation in the event rate of veto-anticoincident
single-detector interactions consistent with nuclear recoils, and constrain the
magnitude of any modulation to <0.06 event [keVnr kg day]^-1 in the 5-11.9
keVnr energy range at the 99% confidence level. These results disfavor an
explanation for the reported modulation in the 1.2-3.2 keVee energy range in
CoGeNT in terms of nuclear recoils resulting from elastic scattering of WIMPs
at >98% confidence. For events consistent with electron recoils, no significant
modulation is observed for either single- or multiple-detector interactions in
the 3.0-7.4 keVee range.
-
The CDMS and EDELWEISS collaborations have combined the results of their
direct searches for dark matter using cryogenic germanium detectors. The total
data set represents 614 kg.d equivalent exposure. A straightforward method of
combination was chosen for its simplicity before data were exchanged between
experiments. The results are interpreted in terms of limits on spin-independent
WIMP-nucleon cross-section. For a WIMP mass of 90 GeV/c^2, where this analysis
is most sensitive, a cross-section of 3.3 x 10^{-44} cm^2 is excluded at 90%
CL. At higher WIMP masses, the combination improves the individual limits, by a
factor 1.6 above 700 GeV/c^2. Alternative methods of combining the data provide
stronger constraints for some ranges of WIMP masses and weaker constraints for
others.
-
Results are presented from a reanalysis of the entire five-tower data set
acquired with the Cryogenic Dark Matter Search (CDMS II) experiment at the
Soudan Underground Laboratory, with an exposure of 969 kg-days. The analysis
window was extended to a recoil energy of 150 keV, and an improved
surface-event background-rejection cut was defined to increase the sensitivity
of the experiment to the inelastic dark matter (iDM) model. Three dark matter
candidates were found between 25 keV and 150 keV. The probability to observe
three or more background events in this energy range is 11%. Because of the
occurrence of these events the constraints on the iDM parameter space are
slightly less stringent than those from our previous analysis, which used an
energy window of 10-100 keV.
-
We report results from a reanalysis of data from the Cryogenic Dark Matter
Search (CDMS II) experiment at the Soudan Underground Laboratory. Data taken
between October 2006 and September 2008 using eight germanium detectors are
reanalyzed with a lowered, 2 keV recoil-energy threshold, to give increased
sensitivity to interactions from Weakly Interacting Massive Particles (WIMPs)
with masses below ~10 GeV/c^2. This analysis provides stronger constraints than
previous CDMS II results for WIMP masses below 9 GeV/c^2 and excludes parameter
space associated with possible low-mass WIMP signals from the DAMA/LIBRA and
CoGeNT experiments.
-
Data taken during the final shallow-site run of the first tower of the
Cryogenic Dark Matter Search (CDMS II) detectors have been reanalyzed with
improved sensitivity to small energy depositions. Four ~224 g germanium and two
~105 g silicon detectors were operated at the Stanford Underground Facility
(SUF) between December 2001 and June 2002, yielding 118 live days of raw
exposure. Three of the germanium and both silicon detectors were analyzed with
a new low-threshold technique, making it possible to lower the germanium and
silicon analysis thresholds down to the actual trigger thresholds of ~1 keV and
~2 keV, respectively. Limits on the spin-independent cross section for weakly
interacting massive particles (WIMPs) to elastically scatter from nuclei based
on these data exclude interesting parameter space for WIMPs with masses below 9
GeV/c^2. Under standard halo assumptions, these data partially exclude
parameter space favored by interpretations of the DAMA/LIBRA and CoGeNT
experiments' data as WIMP signals, and exclude new parameter space for WIMP
masses between 3 GeV/c^2 and 4 GeV/c^2.
-
We report on the analysis of the low-energy electron-recoil spectrum from the
CDMS II experiment using data with an exposure of 443.2 kg-days. The analysis
provides details on the observed counting rate and possible background sources
in the energy range of 2 - 8.5 keV. We find no significant excess in the
counting rate above background, and compare this observation to the recent DAMA
results. In the framework of a conversion of a dark matter particle into
electromagnetic energy, our 90% confidence level upper limit of 0.246
events/kg/day at 3.15 keV is lower than the total rate above background
observed by DAMA by 8.9$\sigma$. In absence of any specific particle physics
model to provide the scaling in cross section between NaI and Ge, we assume a
Z^2 scaling. With this assumption the observed rate in DAMA differs from the
upper limit in CDMS by 6.8$\sigma$. Under the conservative assumption that the
modulation amplitude is 6% of the total rate we obtain upper limits on the
modulation amplitude a factor of ~2 less than observed by DAMA, constraining
some possible interpretations of this modulation.
-
Presently the CDMS-II collaboration's Weakly Interacting Massive Particle
(WIMP) search at the Soudan Underground Laboratory sets the most stringent
exclusion limits of any WIMP cold dark matter direct-detection experiment. To
extend our reach further, to WIMP-nucleon cross sections in the range $10^{-46}
- 10^{-44}$cm$^2$, we propose SuperCDMS, which would take advantage of a very
deep site. One promising site is the recently approved SNOLab facility in
Canada. In this paper we will present our overall plan, identify primary
issues, and set the goals that need to be met prior to embarking upon each
phase of SuperCDMS.