The next-generation Enriched Xenon Observatory (nEXO) is a proposed
experiment to search for neutrinoless double beta ($0\nu\beta\beta$) decay in
$^{136}$Xe with a target half-life sensitivity of approximately $10^{28}$ years
using $5\times10^3$ kg of isotopically enriched liquid-xenon in a time
projection chamber. This improvement of two orders of magnitude in sensitivity
over current limits is obtained by a significant increase of the $^{136}$Xe
mass, the monolithic and homogeneous configuration of the active medium, and
the multi-parameter measurements of the interactions enabled by the time
projection chamber. The detector concept and anticipated performance are
presented based upon demonstrated realizable background rates.
-
A new design for the anode of a time projection chamber, consisting of a
charge-detecting "tile", is investigated for use in large scale liquid xenon
detectors. The tile is produced by depositing 60 orthogonal metal
charge-collecting strips, 3~mm wide, on a 10~\si{\cm} $\times$ 10~\si{\cm}
fused-silica wafer. These charge tiles may be employed by large detectors, such
as the proposed tonne-scale nEXO experiment to search for neutrinoless
double-beta decay. Modular by design, an array of tiles can cover a sizable
area. The width of each strip is small compared to the size of the tile, so a
Frisch grid is not required. A grid-less, tiled anode design is beneficial for
an experiment such as nEXO, where a wire tensioning support structure and
Frisch grid might contribute radioactive backgrounds and would have to be
designed to accommodate cycling to cryogenic temperatures. The segmented anode
also reduces some degeneracies in signal reconstruction that arise in
large-area crossed-wire time projection chambers. A prototype tile was tested
in a cell containing liquid xenon. Very good agreement is achieved between the
measured ionization spectrum of a $^{207}$Bi source and simulations that
include the microphysics of recombination in xenon and a detailed modeling of
the electrostatic field of the detector. An energy resolution $\sigma/E$=5.5\%
is observed at 570~\si{keV}, comparable to the best intrinsic ionization-only
resolution reported in literature for liquid xenon at 936~V/\si{cm}.
-
We present the FP420 R&D project, which has been studying the key aspects of
the development and installation of a silicon tracker and fast-timing detectors
in the LHC tunnel at 420 m from the interaction points of the ATLAS and CMS
experiments. These detectors would measure precisely very forward protons in
conjunction with the corresponding central detectors as a means to study
Standard Model (SM) physics, and to search for and characterise New Physics
signals. This report includes a detailed description of the physics case for
the detector and, in particular, for the measurement of Central Exclusive
Production, pp --> p + phi + p, in which the outgoing protons remain intact and
the central system phi may be a single particle such as a SM or MSSM Higgs
boson. Other physics topics discussed are gamma-gamma and gamma-p interactions,
and diffractive processes. The report includes a detailed study of the trigger
strategy, acceptance, reconstruction efficiencies, and expected yields for a
particular p p --> p H p measurement with Higgs boson decay in the b-bbar mode.
The document also describes the detector acceptance as given by the LHC beam
optics between the interaction points and the FP420 location, the machine
backgrounds, the new proposed connection cryostat and the moving ("Hamburg")
beam-pipe at 420 m, and the radio-frequency impact of the design on the LHC.
The last part of the document is devoted to a description of the 3D silicon
sensors and associated tracking performances, the design of two fast-timing
detectors capable of accurate vertex reconstruction for background rejection at
high-luminosities, and the detector alignment and calibration strategy.
-
We have measured the temporal duration of 45 MeV picosecond electron beam
bunches using a noninvasive electro-optical (EO) technique. The amplitude of
the EO modulation was found to increase linearly with electron beam charge and
decrease inversely with distance from the electron beam. The risetime of the
temporal signal was limited by our detection system to ~70ps. The EO signal due
to ionization caused by the electrons traversing the EO crystal was also
observed. It has a distinctively long decay time constant and signal polarity
opposite to that due to the field induced by the electron beam. The
electro-optical technique may be ideal for the measurement of bunch length of
femtosecond, relativistic, high energy, charged, particle beams.