The TOTEM collaboration has measured the proton-proton total cross section at
$\sqrt{s}=13$ TeV with a luminosity-independent method. Using dedicated
$\beta^{*}=90$ m beam optics, the Roman Pots were inserted very close to the
beam. The inelastic scattering rate has been measured by the T1 and T2
telescopes during the same LHC fill. After applying the optical theorem the
total proton-proton cross section is $\sigma_{\rm tot}=(110.6 \pm 3.4$) mb,
well in agreement with the extrapolation from lower energies. This method also
allows one to derive the luminosity-independent elastic and inelastic cross
sections: $\sigma_{\rm el} = (31.0 \pm 1.7)$ mb and $\sigma_{\rm inel} = (79.5
\pm 1.8)$ mb.
-
This paper describes the design and the performance of the timing detector
developed by the TOTEM Collaboration for the Roman Pots (RPs) to measure the
Time-Of-Flight (TOF) of the protons produced in central diffractive
interactions at the LHC. The measurement of the TOF of the protons allows the
determination of the longitudinal position of the proton interaction vertex and
its association with one of the vertices reconstructed by the CMS detectors.
The TOF detector is based on single crystal Chemical Vapor Deposition (scCVD)
diamond plates and is designed to measure the protons TOF with about 50 ps time
precision. This upgrade to the TOTEM apparatus will be used in the LHC run 2
and will tag the central diffractive events up to an interaction pileup of
about 1. A dedicated fast and low noise electronics for the signal
amplification has been developed. The digitization of the diamond signal is
performed by sampling the waveform. After introducing the physics studies that
will most profit from the addition of these new detectors, we discuss in detail
the optimization and the performance of the first TOF detector installed in the
LHC in November 2015.
-
The TOTEM experiment at the CERN LHC has measured elastic proton-proton
scattering at the centre-of-mass energy $\sqrt{s}$ = 8 TeV and four-momentum
transfers squared, |t|, from 6 x $10^{-4}$ GeV$^2$ to 0.2 GeV$^2$. Near the
lower end of the |t|-interval the differential cross-section is sensitive to
the interference between the hadronic and the electromagnetic scattering
amplitudes. This article presents the elastic cross-section measurement and the
constraints it imposes on the functional forms of the modulus and phase of the
hadronic elastic amplitude. The data exclude the traditional Simplified West
and Yennie interference formula that requires a constant phase and a purely
exponential modulus of the hadronic amplitude. For parametrisations of the
hadronic modulus with second- or third-order polynomials in the exponent, the
data are compatible with hadronic phase functions giving either central or
peripheral behaviour in the impact parameter picture of elastic scattering. In
both cases, the $\rho$-parameter is found to be 0.12 $\pm$ 0.03. The results
for the total hadronic cross-section are $\sigma_{tot}$ = (102.9 $\pm$ 2.3) mb
and (103.0 $\pm$ 2.3) mb for central and peripheral phase formulations,
respectively. Both are consistent with previous TOTEM measurements.
-
The TOTEM experiment has made a precise measurement of the elastic
proton-proton differential cross-section at the centre-of-mass energy sqrt(s) =
8 TeV based on a high-statistics data sample obtained with the beta* = 90
optics. Both the statistical and systematic uncertainties remain below 1%,
except for the t-independent contribution from the overall normalisation. This
unprecedented precision allows to exclude a purely exponential differential
cross-section in the range of four-momentum transfer squared 0.027 < |t| < 0.2
GeV^2 with a significance greater than 7 sigma. Two extended parametrisations,
with quadratic and cubic polynomials in the exponent, are shown to be well
compatible with the data. Using them for the differential cross-section
extrapolation to t = 0, and further applying the optical theorem, yields total
cross-section estimates of (101.5 +- 2.1) mb and (101.9 +- 2.1) mb,
respectively, in agreement with previous TOTEM measurements.
-
The pseudorapidity density of charged particles dN(ch)/deta is measured by
the TOTEM experiment in pp collisions at sqrt(s) = 8 TeV within the range 3.9 <
eta < 4.7 and -6.95 < eta < -6.9. Data were collected in a low intensity LHC
run with collisions occurring at a distance of 11.25 m from the nominal
interaction point. The data sample is expected to include 96-97\% of the
inelastic proton-proton interactions. The measurement reported here considers
charged particles with p_T > 0 MeV/c, produced in inelastic interactions with
at least one charged particle in -7 < eta < -6 or 3.7 < eta <4.8 . The
dN(ch)/deta has been found to decrease with |eta|, from 5.11 +- 0.73 at eta =
3.95 to 1.81 +- 0.56 at eta= - 6.925. Several MC generators are compared to the
data and are found to be within the systematic uncertainty of the measurement.
-
Precise knowledge of the beam optics at the LHC is crucial to fulfil the
physics goals of the TOTEM experiment, where the kinematics of the scattered
protons is reconstructed with the near-beam telescopes -- so-called Roman Pots
(RP). Before being detected, the protons' trajectories are influenced by the
magnetic fields of the accelerator lattice. Thus precise understanding of the
proton transport is of key importance for the experiment. A novel method of
optics evaluation is proposed which exploits kinematical distributions of
elastically scattered protons observed in the RPs. Theoretical predictions, as
well as Monte Carlo studies, show that the residual uncertainty of this optics
estimation method is smaller than 0.25 percent.
-
The TOTEM Experiment is designed to measure the total proton-proton
cross-section with the luminosity-independent method and to study elastic and
diffractive pp scattering at the LHC. To achieve optimum forward coverage for
charged particles emitted by the pp collisions in the interaction point IP5,
two tracking telescopes, T1 and T2, are installed on each side of the IP in the
pseudorapidity region 3.1 < = |eta | < = 6.5, and special movable beam-pipe
insertions - called Roman Pots (RP) - are placed at distances of +- 147 m and
+- 220 m from IP5. This article describes in detail the working of the TOTEM
detector to produce physics results in the first three years of operation and
data taking at the LHC.
-
The first double diffractive cross-section measurement in the very forward
region has been carried out by the TOTEM experiment at the LHC with
center-of-mass energy of sqrt(s)=7 TeV. By utilizing the very forward TOTEM
tracking detectors T1 and T2, which extend up to |eta|=6.5, a clean sample of
double diffractive pp events was extracted. From these events, we measured the
cross-section sigma_DD =(116 +- 25) mub for events where both diffractive
systems have 4.7 <|eta|_min < 6.5 .
-
2nd workshop on the implications of HERA for LHC physics. Working groups:
Parton Density Functions Multi-jet final states and energy flows Heavy quarks
(charm and beauty) Diffraction Cosmic Rays Monte Carlos and Tools
-
The TOTEM experiment at the LHC measures the total proton-proton cross
section with the luminosity-independent method and the elastic proton-proton
cross-section over a wide |t|-range. It also performs a comprehensive study of
diffraction, spanning from cross-section measurements of individual diffractive
processes to the analysis of their event topologies. Hard diffraction will be
studied in collaboration with CMS taking advantage of the large common rapidity
coverage for charged and neutral particle detection and the large variety of
trigger possibilities even at large luminosities. TOTEM will take data under
all LHC beam conditions including standard high luminosity runs to maximize its
physics reach. This contribution describes the main features of the TOTEM
physics programme including measurements to be made in the early LHC runs. In
addition, a novel scheme to extend the diffractive proton acceptance for high
luminosity runs by installing proton detectors at IP3 is described.
-
A breast neoplasia is often marked by the presence of microcalcifications and
massive lesions in the mammogram: hence the need for tools able to recognize
such lesions at an early stage. Our collaboration, among italian physicists and
radiologists, has built a large distributed database of digitized mammographic
images and has developed a Computer Aided Detection (CADe) system for the
automatic analysis of mammographic images and installed it in some Italian
hospitals by a GRID connection. Regarding microcalcifications, in our CADe
digital mammogram is divided into wide windows which are processed by a
convolution filter; after a self-organizing map analyzes each window and
produces 8 principal components which are used as input of a neural network
(FFNN) able to classify the windows matched to a threshold. Regarding massive
lesions we select all important maximum intensity position and define the ROI
radius. From each ROI found we extract the parameters which are used as input
in a FFNN to distinguish between pathological and non-pathological ROI. We
present here a test of our CADe system, used as a second reader and a
comparison with another (commercial) CADe system.
-
The GPCALMA (Grid Platform for Computer Assisted Library for MAmmography)
collaboration involves several departments of physics, INFN sections, and
italian hospitals. The aim of this collaboration is developing a tool that can
help radiologists in early detection of breast cancer. GPCALMA has built a
large distributed database of digitised mammographic images (about 5500 images
corresponding to 1650 patients) and developed a CAD (Computer Aided Detection)
software which is integrated in a station that can also be used for acquire new
images, as archive and to perform statistical analysis. The images are
completely described: pathological ones have a consistent characterization with
radiologist's diagnosis and histological data, non pathological ones correspond
to patients with a follow up at least three years. The distributed database is
realized throught the connection of all the hospitals and research centers in
GRID tecnology. In each hospital local patients digital images are stored in
the local database. Using GRID connection, GPCALMA will allow each node to work
on distributed database data as well as local database data. Using its database
the GPCALMA tools perform several analysis. A texture analysis, i.e. an
automated classification on adipose, dense or glandular texture, can be
provided by the system. GPCALMA software also allows classification of
pathological features, in particular massive lesions analysis and
microcalcification clusters analysis. The performance of the GPCALMA system
will be presented in terms of the ROC (Receiver Operating Characteristic)
curves. The results of GPCALMA system as "second reader" will also be
presented.
-
The next generation of High Energy Physics (HEP) experiments requires a GRID
approach to a distributed computing system and the associated data management:
the key concept is the Virtual Organisation (VO), a group of distributed users
with a common goal and the will to share their resources. A similar approach is
being applied to a group of Hospitals which joined the GPCALMA project (Grid
Platform for Computer Assisted Library for MAmmography), which will allow
common screening programs for early diagnosis of breast and, in the future,
lung cancer. HEP techniques come into play in writing the application code,
which makes use of neural networks for the image analysis and proved to be
useful in improving the radiologists' performances in the diagnosis. GRID
technologies allow remote image analysis and interactive online diagnosis, with
a potential for a relevant reduction of the delays presently associated to
screening programs. A prototype of the system, based on AliEn GRID Services, is
already available, with a central Server running common services and several
clients connecting to it. Mammograms can be acquired in any location; the
related information required to select and access them at any time is stored in
a common service called Data Catalogue, which can be queried by any client. The
result of a query can be used as input for analysis algorithms, which are
executed on nodes that are in general remote to the user (but always local to
the input images) thanks to the PROOF facility. The selected approach avoids
data transfers for all the images with a negative diagnosis (about 95% of the
sample) and allows an almost real time diagnosis for the 5% of images with high
cancer probability.
-
The next generation of High Energy Physics experiments requires a GRID
approach to a distributed computing system and the associated data management:
the key concept is the "Virtual Organisation" (VO), a group of geographycally
distributed users with a common goal and the will to share their resources. A
similar approach is being applied to a group of Hospitals which joined the
GPCALMA project (Grid Platform for Computer Assisted Library for MAmmography),
which will allow common screening programs for early diagnosis of breast and,
in the future, lung cancer. HEP techniques come into play in writing the
application code, which makes use of neural networks for the image analysis and
shows performances similar to radiologists in the diagnosis. GRID technologies
will allow remote image analysis and interactive online diagnosis, with a
relevant reduction of the delays presently associated to screening programs.
-
The purpose of this study is the evaluation of the variation of performance
in terms of sensitivity and specificity of two radiologists with different
experience in mammography, with and without the assistance of two different CAD
systems. The CAD considered are SecondLookTM (CADx Medical Systems, Canada),
and CALMA (Computer Assisted Library in MAmmography). The first is a commercial
system, the other is the result of a a research project, supported by INFN
(Istituto Nazionale di Fisica Nucleare, Italy); their characteristics have been
already reported in literature. To compare the results with and without these
tools, a dataset composed by 70 images of patients with cancer (biopsy proven)
and 120 images of healthy breasts (with a three years follow up) has been
collected. All the images have been digitized and analysed by two CAD, then two
radiologists with respectively 6 and 2 years of experience in mammography
indipendently made their diagnosis without and with, the support of the two CAD
systems. In this work sensitivity and specificity variation, the Az area under
the ROC curve, are reported. The results show that the use of a CAD allows for
a substantial increment in sensitivity and a less pronounced decrement in
specificity. The extent of these effects depends on the experience of the
readers and is comparable for the two CAD considered.
-
The use of an automatic system for the analysis of mammographic images has
proven to be very useful to radiologists in the investigation of breast cancer,
especially in the framework of mammographic-screening programs. A breast
neoplasia is often marked by the presence of microcalcification clusters and
massive lesions in the mammogram: hence the need for tools able to recognize
such lesions at an early stage. In the framework of the GPCALMA (GRID Platform
for Computer Assisted Library for MAmmography) project, the co-working of
italian physicists and radiologists built a large distributed database of
digitized mammographic images (about 5500 images corresponding to 1650
patients) and developed a CAD (Computer Aided Detection) system, able to make
an automatic search of massive lesions and microcalcification clusters. The CAD
is implemented in the GPCALMA integrated station, which can be used also for
digitization, as archive and to perform statistical analyses. Some GPCALMA
integrated stations have already been implemented and are currently on clinical
trial in some italian hospitals. The emerging GRID technology can been used to
connect the GPCALMA integrated stations operating in different medical centers.
The GRID approach will support an effective tele- and co-working between
radiologists, cancer specialists and epidemiology experts by allowing remote
image analysis and interactive online diagnosis.
-
Purpose of this work is the development of an automatic system which could be
useful for radiologists in the investigation of breast cancer. A breast
neoplasia is often marked by the presence of microcalcifications and massive
lesions in the mammogram: hence the need for tools able to recognize such
lesions at an early stage. GPCALMA (Grid Platform Computer Assisted Library for
MAmmography), a collaboration among italian physicists and radiologists, has
built a large distributed database of digitized mammographic images (at this
moment about 5500 images corresponding to 1650 patients). This collaboration
has developed a CAD (Computer Aided Detection) system which, installed in an
integrated station, can also be used for digitization, as archive and to
perform statistical analysis. With a GRID configuration it would be possible
for the clinicians tele- and co-working in new and innovative groupings
('virtual organisations') and, using the whole database, by the GPCALMA tools
several analysis can be performed. Furthermore the GPCALMA system allows to be
abreast of the CAD technical progressing into several hospital locations always
with remote working by GRID connection. We report in this work the results
obtained by the GPCALMA CAD software implemented with a GRID connection.