• Login
    Sort by: Relevance Date Users's collections Twitter
    Group by: Day Week Month Year All time
Based on the idea and the provided source code of Andrej Karpathy (arxiv-sanity)
2:3 1:1 3:2
  • Measurement of shower development and its Moli\`ere radius with a four-plane LumiCal test set-up (1705.03885)

    H. Abramowicz, A. Abusleme, K. Afanaciev, Y. Benhammou, L. Bortko, O. Borysov, M. Borysova, I. Bozovic-Jelisavcic, G. Chelkov, W. Daniluk, D. Dannheim, K. Elsener, M. Firlej, E. Firu, T. Fiutowski, V. Ghenescu, M. Gostkin, M. Hempel, H. Henschel, M. Idzik, A. Ignatenko, A. Ishikawa, S. Kananov, O. Karacheban, W. Klempt, S. Kotov, J. Kotula, D. Kozhevnikov, V. Kruchonok, B. Krupa, Sz. Kulis, W. Lange, J. Leonard, T. Lesiak, A. Levy, I. Levy, W. Lohmann, S. Lukic, J. Moron, A. Moszczynski, A.T. Neagu, F.-X. Nuiry, M. Pandurovic, B. Pawlik, T. Preda, O. Rosenblat, A. Sailer, B. Schumm, S. Schuwalow, I. Smiljanic, P. Smolyanskiy, K. Swientek, P. Terlecki, U.I. Uggerhoj, T.N. Wistisen, T. Wojton, H. Yamamoto, L. Zawiejski, I.S. Zgura, A. Zhemchugov
    March 12, 2018 physics.ins-det
    ... ... ... ... ... ...
    A prototype of a luminometer, designed for a future e+e- collider detector, and consisting at present of a four-plane module, was tested in the CERN PS accelerator T9 beam. The objective of this beam test was to demonstrate a multi-plane tungsten/silicon operation, to study the development of the electromagnetic shower and to compare it with MC simulations. The Moli\`ere radius has been determined to be 24.0 +/- 0.6 (stat.) +/- 1.5 (syst.) mm using a parametrization of the shower shape. Very good agreement was found between data and a detailed Geant4 simulation.
  • Performance of fully instrumented detector planes of the forward calorimeter of a Linear Collider detector (1411.4431)

    The FCAL Collaboration: H. Abramowicz, A. Abusleme, K. Afanaciev, J. Aguilar, E. Alvarez, D. Avila, Y. Benhammou, L. Bortko, O. Borysov, M. Bergholz, I. Bozovic-Jelisavcic, E. Castro, G. Chelkov, C. Coca, W. Daniluk, L. Dumitru, K. Elsener, V. Fadeyev, M. Firlej, E. Firu, T. Fiutowski, V. Ghenescu, M. Gostkin, H. Henschel, M. Idzik, A. Ishikawa, S. Kananov, S. Kollowa, S. Kotov, J. Kotula, D. Kozhevnikov, V. Kruchonok, B. Krupa, Sz. Kulis, W. Lange, T. Lesiak, A. Levy, I. Levy, W. Lohmann, S. Lukic, C. Milke, J. Moron, A. Moszczynski, A.T. Neagu, O. Novgorodova, K. Oliwa, M. Orlandea, M. Pandurovic, B. Pawlik, T. Preda, D. Przyborowski, O. Rosenblat, A. Sailer, Y. Sato, B. Schumm, S. Schuwalow, I. Smiljanic, P. Smolyanskiy, K. Swientek, E. Teodorescu, P. Terlecki, W. Wierba, T. Wojton, S. Yamaguchi, H. Yamamoto, L. Zawiejski, I.S. Zgura, A. Zhemchugov
    June 1, 2015 physics.ins-det
    ... ... ... ... ... ...
    Detector-plane prototypes of the very forward calorimetry of a future detector at an e+e- collider have been built and their performance was measured in an electron beam. The detector plane comprises silicon or GaAs pad sensors, dedicated front-end and ADC ASICs, and an FPGA for data concentration. Measurements of the signal-to-noise ratio and the response as a function of the position of the sensor are presented. A deconvolution method is successfully applied, and a comparison of the measured shower shape as a function of the absorber depth with a Monte-Carlo simulation is given.