We present the results of a search for dark matter WIMPs in the mass range
below 20 GeV/c^2 using a target of low-radioactivity argon. The data were
obtained using the DarkSide-50 apparatus at Laboratori Nazionali del Gran Sasso
(LNGS). The analysis is based on the ionization signal, for which the
DarkSide-50 time projection chamber is fully efficient at 0.1 keVee. The
observed rate in the detector at 0.5 keVee is about 1.5 events/keVee/kg/day and
is almost entirely accounted for by known background sources. We obtain a 90%
C.L. exclusion limit above 1.8 GeV/c^2 for the spin-independent cross section
of dark matter WIMPs on nucleons, extending the exclusion region for dark
matter below previous limits in the range 1.8-6 GeV/c^2.
-
We present new constraints on sub-GeV dark matter particles scattering off
electrons in argon based on an analysis of ionization signal data from the
DarkSide-50 detector.
-
The DarkSide-50 direct-detection dark matter experiment is a dual-phase argon
time projection chamber operating at Laboratori Nazionali del Gran Sasso. This
paper reports on the blind analysis and spin-independent dark matter-nucleon
coupling results from a 532.4 live-days exposure, using a target of
low-radioactivity argon extracted from underground sources. The background-free
result in the dark matter selection box gave no evidence for dark matter. The
present blind analysis sets a 90% C.L. upper limit on the dark matter-nucleon
spin-independent cross section of 1.1E-44 cm^2 (3.8E-44 cm^2, 3.4E-43 cm^2) for
a WIMP mass of 100 GeV/c^2 (1 TeV/c^2, 10 TeV/c^2).
-
We report the measurement of the longitudinal diffusion constant in liquid
argon with the DarkSide-50 dual-phase time projection chamber. The measurement
is performed at drift electric fields of 100 V/cm, 150 V/cm, and 200 V/cm using
high statistics $^{39}$Ar decays from atmospheric argon. We derive an
expression to describe the pulse shape of the electroluminescence signal (S2)
in dual-phase TPCs. The derived S2 pulse shape is fit to events from the
uppermost portion of the TPC in order to characterize the radial dependence of
the signal. The results are provided as inputs to the measurement of the
longitudinal diffusion constant DL, which we find to be (4.12 $\pm$ 0.04)
cm$^2$/s for a selection of 140keV electron recoil events in 200V/cm drift
field and 2.8kV/cm extraction field. To study the systematics of our
measurement we examine datasets of varying event energy, field strength, and
detector volume yielding a weighted average value for the diffusion constant of
(4.09 $\pm$ 0.09) cm$^2$ /s. The measured longitudinal diffusion constant is
observed to have an energy dependence, and within the studied energy range the
result is systematically lower than other results in the literature.
-
This paper describes the design, fabrication, commissioning and use of a
CALibration source Insertion System (CALIS) in the DarkSide-50 direct dark
matter search experiment. CALIS deploys radioactive sources into the liquid
scintillator veto to characterize the detector response and detection
efficiency of the DarkSide-50 Liquid Argon Time Projection Chamber, and the
surrounding 30 t organic liquid scintillator neutron veto. It was commissioned
in September 2014 and has been used successfully in several gamma and neutron
source campaigns since then. A description of the hardware and an excerpt of
calibration analysis results are given below.
-
A Geant4-based Monte Carlo package named G4DS has been developed to simulate
the response of DarkSide-50, an experiment operating since 2013 at LNGS,
designed to detect WIMP interactions in liquid argon. In the process of WIMP
searches, DarkSide-50 has achieved two fundamental milestones: the rejection of
electron recoil background with a power of ~10^7, using the pulse shape
discrimination technique, and the measurement of the residual 39Ar
contamination in underground argon, ~3 orders of magnitude lower with respect
to atmospheric argon. These results rely on the accurate simulation of the
detector response to the liquid argon scintillation, its ionization, and
electron-ion recombination processes. This work provides a complete overview of
the DarkSide Monte Carlo and of its performance, with a particular focus on
PARIS, the custom-made liquid argon response model.
-
We report on the cryogenic characterization of Red Green Blue - High Density
(RGB-HD) SiPMs developed at Fondazione Bruno Kessler (FBK) as part of the
DarkSide program of dark matter searches with liquid argon time projection
chambers. A dedicated setup was used to measure the primary dark noise, the
correlated noise, and the gain of the SiPMs at varying temperatures. A
custom-made data acquisition system and analysis software were used to
precisely characterize these parameters. We demonstrate that FBK RGB-HD SiPMs
with low quenching resistance (RGB-HD-LR$_q$) can be operated from 40 K to 300
K with gains in the range $10^5$ to $10^6$ and noise rates on the order of a
few Hz/mm$^2$.
-
Building on the successful experience in operating the DarkSide-50 detector,
the DarkSide Collaboration is going to construct DarkSide-20k, a direct WIMP
search detector using a two-phase Liquid Argon Time Projection Chamber (LArTPC)
with an active (fiducial) mass of 23 t (20 t). The DarkSide-20k LArTPC will be
deployed within a shield/veto with a spherical Liquid Scintillator Veto (LSV)
inside a cylindrical Water Cherenkov Veto (WCV). Operation of DarkSide-50
demonstrated a major reduction in the dominant $^{39}$Ar background when using
argon extracted from an underground source, before applying pulse shape
analysis. Data from DarkSide-50, in combination with MC simulation and
analytical modeling, shows that a rejection factor for discrimination between
electron and nuclear recoils of $\gt3\times10^9$ is achievable. This, along
with the use of the veto system, is the key to unlocking the path to large
LArTPC detector masses, while maintaining an "instrumental background-free"
experiment, an experiment in which less than 0.1 events (other than
$\nu$-induced nuclear recoils) is expected to occur within the WIMP search
region during the planned exposure. DarkSide-20k will have ultra-low
backgrounds than can be measured in situ. This will give sensitivity to
WIMP-nucleon cross sections of $1.2\times10^{-47}$ cm$^2$ ($1.1\times10^{-46}$
cm$^2$) for WIMPs of $1$ TeV$/c^2$ ($10$ TeV$/c^2$) mass, to be achieved during
a 5 yr run producing an exposure of 100 t yr free from any instrumental
background. DarkSide-20k could then extend its operation to a decade,
increasing the exposure to 200 t yr, reaching a sensitivity of
$7.4\times10^{-48}$ cm$^2$ ($6.9\times10^{-47}$ cm$^2$) for WIMPs of $1$
TeV$/c^2$ ($10$ TeV$/c^2$) mass.
-
Measurements were made of scintillation light yield of alpha particles from
the $^{222}$Rn decay chain within the DarkSide-50 liquid argon time projection
chamber. The light yield was found to increase as the applied electric field
increased, with alphas in a 200 V/cm electric field exhibiting a 2% increase in
light yield compared to alphas in no field.
-
DarkSide-50 is a detector for dark matter candidates in the form of weakly
interacting massive particles (WIMPs). It utilizes a liquid argon time
projection chamber (LAr TPC) for the inner main detector. The TPC is surrounded
by a liquid scintillator veto (LSV) and a water Cherenkov veto detector (WCV).
The LSV and WCV, both instrumented with PMTs, act as the neutron and cosmogenic
muon veto detectors for DarkSide-50. This paper describes the electronics and
data acquisition system used for these two detectors.
-
Liquid argon is a bright scintillator with potent particle identification
properties, making it an attractive target for direct-detection dark matter
searches. The DarkSide-50 dark matter search here reports the first WIMP search
results obtained using a target of low-radioactivity argon. DarkSide-50 is a
dark matter detector, using two-phase liquid argon time projection chamber,
located at the Laboratori Nazionali del Gran Sasso. The underground argon is
shown to contain Ar-39 at a level reduced by a factor (1.4 +- 0.2) x 10^3
relative to atmospheric argon. We report a background-free null result from
(2616 +- 43) kg d of data, accumulated over 70.9 live-days. When combined with
our previous search using an atmospheric argon, the 90 % C.L. upper limit on
the WIMP-nucleon spin-independent cross section based on zero events found in
the WIMP search regions, is 2.0 x 10^-44 cm^2 (8.6 x 10^-44 cm^2, 8.0 x 10^-43
cm^2) for a WIMP mass of 100 GeV/c^2 (1 TeV/c^2 , 10 TeV/c^2).
-
Nuclear recoil events produced by neutron scatters form one of the most
important classes of background in WIMP direct detection experiments, as they
may produce nuclear recoils that look exactly like WIMP interactions. In
DarkSide-50, we both actively suppress and measure the rate of neutron-induced
background events using our neutron veto, composed of a boron-loaded liquid
scintillator detector within a water Cherenkov detector. This paper is devoted
to the description of the neutron veto system of DarkSide-50, including the
detector structure, the fundamentals of event reconstruction and data analysis,
and basic performance parameters.
-
The International Axion Observatory (IAXO) will be a forth generation axion
helioscope. As its primary physics goal, IAXO will look for axions or
axion-like particles (ALPs) originating in the Sun via the Primakoff conversion
of the solar plasma photons. In terms of signal-to-noise ratio, IAXO will be
about 4-5 orders of magnitude more sensitive than CAST, currently the most
powerful axion helioscope, reaching sensitivity to axion-photon couplings down
to a few $\times 10^{-12}$ GeV$^{-1}$ and thus probing a large fraction of the
currently unexplored axion and ALP parameter space. IAXO will also be sensitive
to solar axions produced by mechanisms mediated by the axion-electron coupling
$g_{ae}$ with sensitivity $-$for the first time$-$ to values of $g_{ae}$ not
previously excluded by astrophysics. With several other possible physics cases,
IAXO has the potential to serve as a multi-purpose facility for generic axion
and ALP research in the next decade. In this paper we present the conceptual
design of IAXO, which follows the layout of an enhanced axion helioscope, based
on a purpose-built 20m-long 8-coils toroidal superconducting magnet. All the
eight 60cm-diameter magnet bores are equipped with focusing x-ray optics, able
to focus the signal photons into $\sim 0.2$ cm$^2$ spots that are imaged by
ultra-low-background Micromegas x-ray detectors. The magnet is built into a
structure with elevation and azimuth drives that will allow for solar tracking
for $\sim$12 h each day.
-
The axio-electric effect in silicon atoms is sought for solar axions
appearing owing to bremsstrahlung and the Compton process. Axions are detected
using a Si(Li) detector placed in a low-background setup. As a result, a
model-independent constraint on the axion-electron coupling constant $|g_{Ae}|
\leq 2.2\times 10^{-10}$ has been obtained, which leads to the bounds
$m_{A}\leq$ 7.9 eV and $m_{A}\leq$ 1.4 keV for the mass of the axion in the
DFSZ and KSVZ models, respectively (90% C.L.).
-
A project of search for oscillations of reactor neutrinos on a short, 5 - 15
meters, baseline with liquid scintillation position-sensitive detector POSEIDON
is described. The oscillations of the electron antineutrinos into sterile
neutrinos will be searched at 100 MW research reactor with the size of the
active zone of about 0.5 m. The values of the oscillation parameters available
for research are in the region $\delta m^2 = (0.3 - 6) \rm{eV}^2$ and
$\rm{Sin}^2(2\theta)\geq 0.01$.