The scientific performance of the Planck Low Frequency Instrument (LFI) after
one year of in-orbit operation is presented. We describe the main optical
parameters and discuss photometric calibration, white noise sensitivity, and
noise properties. A preliminary evaluation of the impact of the main systematic
effects is presented. For each of the performance parameters, we outline the
methods used to obtain them from the flight data and provide a comparison with
pre-launch ground assessments, which are essentially confirmed in flight.
-
In this paper we discuss the linearity response of the Planck-LFI receivers,
with particular reference to signal compression measured on the 30 and 44 GHz
channels. In the article we discuss the various sources of compression and
present a model that accurately describes data measured during tests performed
with individual radiomeric chains. After discussing test results we present the
best parameter set representing the receiver response and discuss the impact of
non linearity on in-flight calibration, which is shown to be negligible.
-
This paper is part of the Prelaunch status LFI papers published on JINST:
http://www.iop.org/EJ/journal/-page=extra.proc5/jinst
The Planck LFI Radiometer Chain Assemblies (RCAs) have been calibrated in two
dedicated cryogenic facilities. In this paper the facilities and the related
instrumentation are described. The main satellite thermal interfaces for the
single chains have to be reproduced and stability requirements have to be
satisfied. Setup design, problems occurred and improving solutions implemented
are discussed. Performance of the cryogenic setup are reported.
-
70 GHz radiometer front-end and back-end modules for the Low Frequency
Instrument of the European Space Agencys Planck Mission were built and tested.
The operating principles and the design details of the mechanical structures
are described along with the key InP MMIC low noise amplifiers and phase
switches of the units. The units were tested in specially designed cryogenic
vacuum chambers capable of producing the operating conditions required for
Planck radiometers, specifically, a physical temperature of 20 K for the
front-end modules, 300 K for the back-end modules and 4 K for the reference
signal sources. Test results of the low noise amplifiers and phase switches,
the front and back-end modules, and the combined results of both modules are
discussed.
At 70 GHz frequency, the system noise temperature of the front and back end
is 28 K; the effective bandwidth 16 GHz, and the 1/f spectrum knee frequency is
38 mHz. The test results indicate state-of-the-art performance at 70 GHz
frequency and fulfil the Planck performance requirements.