-
We report the first result on Ge-76 neutrinoless double beta decay from
CDEX-1 experiment at China Jinping Underground Laboratory. A mass of 994 g
p-type point-contact high purity germanium detector has been installed to
search the neutrinoless double beta decay events, as well as to directly detect
dark matter particles. An exposure of 304 kg*day has been analyzed. The
wideband spectrum from 500 keV to 3 MeV was obtained and the average event rate
at the 2.039 MeV energy range is about 0.012 count per keV per kg per day. The
half-life of Ge-76 neutrinoless double beta decay has been derived based on
this result as: T 1/2 > 6.4*10^22 yr (90% C.L.). An upper limit on the
effective Majorana-neutrino mass of 5.0 eV has been achieved. The possible
methods to further decrease the background level have been discussed and will
be pursued in the next stage of CDEX experiment.
-
We report the WIMP dark matter search results using the first physics-run
data of the PandaX-II 500 kg liquid xenon dual-phase time-projection chamber,
operating at the China JinPing Underground Laboratory. No dark matter candidate
is identified above background. In combination with the data set during the
commissioning run, with a total exposure of 3.3$\times10^4$ kg-day,the most
stringent limit to the spin-independent interaction between the ordinary and
WIMP dark matter is set for a range of dark matter mass between 3.5 and 1000
GeV/c$^2$. The best upper limit on the scattering cross section is found
$2.5\times 10^{-46}$ cm$^2$ for the WIMP mass 40 GeV/c$^2$ at 90% confidence
level.
-
We present the results of a search for WIMPs from the commissioning run of
the PandaX-II experiment located at the China Jinping underground Laboratory. A
WIMP search data set with an exposure of 306$\times$19.1 kg-day was taken,
while its dominant $^{85}$Kr background was used as the electron recoil
calibration. No WIMP candidates are identified, and a 90\% upper limit is set
on the spin-independent elastic WIMP-nucleon cross section with a lowest
excluded cross section of 2.97$\times$10$^{-45}$~cm$^2$ at a WIMP mass of
44.7~GeV/c$^2$.
-
We report the results of a weakly-interacting massive particle (WIMP) dark
matter search using the full 80.1\;live-day exposure of the first stage of the
PandaX experiment (PandaX-I) located in the China Jin-Ping Underground
Laboratory. The PandaX-I detector has been optimized for detecting low-mass
WIMPs, achieving a photon detection efficiency of 9.6\%. With a fiducial liquid
xenon target mass of 54.0\,kg, no significant excess event were found above the
expected background. A profile likelihood analysis confirms our earlier finding
that the PandaX-I data disfavor all positive low-mass WIMP signals reported in
the literature under standard assumptions. A stringent bound on the low mass
WIMP is set at WIMP mass below 10\,GeV/c$^2$, demonstrating that liquid xenon
detectors can be competitive for low-mass WIMP searches.
-
We report on the first dark-matter (DM) search results from PandaX-I, a low
threshold dual-phase xenon experiment operating at the China Jinping
Underground Laboratory. In the 37-kg liquid xenon target with 17.4 live-days of
exposure, no DM particle candidate event was found. This result sets a
stringent limit for low-mass DM particles and disfavors the interpretation of
previously-reported positive experimental results. The minimum upper limit,
$3.7\times10^{-44}$\,cm$^2$, for the spin-independent isoscalar
DM-particle-nucleon scattering cross section is obtained at a DM-particle mass
of 49\,GeV/c$^2$ at 90\% confidence level.