• Login
    Sort by: Relevance Date Users's collections Twitter
    Group by: Day Week Month Year All time
Based on the idea and the provided source code of Andrej Karpathy (arxiv-sanity)
2:3 1:1 3:2
  • The first result on 76Ge neutrinoless double beta decay from CDEX-1 experiment (1703.01877)

    Li Wang, Qian Yue, KeJun Kang, JianPing Cheng, YuanJing Li, TszKing Henry Wong, ShinTed Lin, JianPing Chang, JingHan Chen, QingHao Chen, YunHua Chen, Zhi Deng, Qiang Du, Hui Gong, Li He, QingJu He, JinWei Hu, HanXiong Huang, TengRui Huang, LiPing Jia, Hao Jiang, HauBin Li, Hong Li, JianMin Li, Jin Li, Jun Li, Xia Li, XinYing Li, XueQian Li, YuLan Li, FongKay Lin, ShuKui Liu, Hao Ma, JingLu Ma, XingYu Pan, Jie Ren, XiChao Ruan, ManBin Shen, Vivek Sharma, Lakhwinder Singh, Manoj Kumar Singh, Manoj Kumar Singh, Arun Kumar Soma, Jian Su, ChangJian Tang, WeiYou Tang, ChaoHsiung Tseng, JiMin Wang, Qing Wang, ShiYong Wu, Wei Wu, YuCheng Wu, HaoYang Xing, Yin Xu, Tao Xue, LiTao Yang, SongWei Yang, Nan Yi, ChunXu Yu, HaiJun Yu, WeiHe Zeng, XiongHui Zeng, Zhi Zeng, Lan Zhang, YunHua Zhang, MingGang Zhao, Wei Zhao, SuNing Zhong, JiFang Zhou, ZuYing Zhou, JingJun Zhu, WeiBin Zhu, ZhongHua Zhu
    March 6, 2017 hep-ex, nucl-ex, physics.ins-det
    We report the first result on Ge-76 neutrinoless double beta decay from CDEX-1 experiment at China Jinping Underground Laboratory. A mass of 994 g p-type point-contact high purity germanium detector has been installed to search the neutrinoless double beta decay events, as well as to directly detect dark matter particles. An exposure of 304 kg*day has been analyzed. The wideband spectrum from 500 keV to 3 MeV was obtained and the average event rate at the 2.039 MeV energy range is about 0.012 count per keV per kg per day. The half-life of Ge-76 neutrinoless double beta decay has been derived based on this result as: T 1/2 > 6.4*10^22 yr (90% C.L.). An upper limit on the effective Majorana-neutrino mass of 5.0 eV has been achieved. The possible methods to further decrease the background level have been discussed and will be pursued in the next stage of CDEX experiment.
  • Dark Matter Results from First 98.7-day Data of PandaX-II Experiment (1607.07400)

    PandaX-II Collaboration: Andi Tan, Mengjiao Xiao, Xiangyi Cui, Xun Chen, Yunhua Chen, Deqing Fang, Changbo Fu, Karl Giboni, Franco Giuliani, Haowei Gong, Shouyang Hu, Xingtao Huang, Xiangdong Ji, Yonglin Ju, Siao Lei, Shaoli Li, Xiaomei Li, Xinglong Li, Hao Liang, Qing Lin, Huaxuan Liu, Jianglai Liu, Wolfgang Lorenzon, Yugang Ma, Yajun Mao, Kaixuan Ni, Xiangxiang Ren, Michael Schubnell, Manbin Shen, Fang Shi, Hongwei Wang, Jiming Wang, Meng Wang, Qiuhong Wang, Siguang Wang, Xuming Wang, Zhou Wang, Shiyong Wu, Xiang Xiao, Pengwei Xie, Binbin Yan, Yong Yang, Jianfeng Yue, Xionghui Zeng, Hongguang Zhang, Hua Zhang, Huanqiao Zhang, Tao Zhang, Li Zhao, Jing Zhou, Ning Zhou, Xiaopeng Zhou
    Aug. 23, 2016 hep-ex, physics.ins-det
    ... ... ... ... ... ...
    We report the WIMP dark matter search results using the first physics-run data of the PandaX-II 500 kg liquid xenon dual-phase time-projection chamber, operating at the China JinPing Underground Laboratory. No dark matter candidate is identified above background. In combination with the data set during the commissioning run, with a total exposure of 3.3$\times10^4$ kg-day,the most stringent limit to the spin-independent interaction between the ordinary and WIMP dark matter is set for a range of dark matter mass between 3.5 and 1000 GeV/c$^2$. The best upper limit on the scattering cross section is found $2.5\times 10^{-46}$ cm$^2$ for the WIMP mass 40 GeV/c$^2$ at 90% confidence level.
  • Dark Matter Search Results from the Commissioning Run of PandaX-II (1602.06563)

    PandaX Collaboration: Andi Tan, Xiang Xiao, Xiangyi Cui, Xun Chen, Yunhua Chen, Deqing Fang, Changbo Fu, Karl Giboni, Franco Giuliani, Haowei Gong, Shouyang Hu, Xingtao Huang, Xiangdong Ji, Yonglin Ju, Siao Lei, Shaoli Li, Xiaomei Li, Xinglong Li, Hao Liang, Qing Lin, Huaxuan Liu, Jianglai Liu, Wolfgang Lorenzon, Yugang Ma, Yajun Mao, Kaixuan Ni, Kirill Pushkin, Xiangxiang Ren, Michael Schubnell, Manbin Shen, Fang Shi, Scott Stephenson, Hongwei Wang, Jiming Wang, Meng Wang, Qiuhong Wang, Siguang Wang, Xuming Wang, Zhou Wang, Shiyong Wu, Mengjiao Xiao, Pengwei Xie, Binbin Yan, Yong Yang, Jianfeng Yue, Xionghui Zeng, Hongguang Zhang, Hua Zhang, Huanqiao Zhang, Tao Zhang, Li Zhao, Jing Zhou, Xiaopeng Zhou
    June 5, 2016 hep-ex, physics.ins-det
    ... ... ... ... ... ...
    We present the results of a search for WIMPs from the commissioning run of the PandaX-II experiment located at the China Jinping underground Laboratory. A WIMP search data set with an exposure of 306$\times$19.1 kg-day was taken, while its dominant $^{85}$Kr background was used as the electron recoil calibration. No WIMP candidates are identified, and a 90\% upper limit is set on the spin-independent elastic WIMP-nucleon cross section with a lowest excluded cross section of 2.97$\times$10$^{-45}$~cm$^2$ at a WIMP mass of 44.7~GeV/c$^2$.
  • Low-mass dark matter search results from full exposure of PandaX-I experiment (1505.00771)

    PandaX Collaboration: Xiang Xiao, Xun Chen, Andi Tan, Yunhua Chen, Xiangyi Cui, Deqing Fang, Changbo Fu, Karl L. Giboni, Haowei Gong, Guodong Guo, Ming He, Xiangdong Ji, Yonglin Ju, Siao Lei, Shaoli Li, Qing Lin, Huaxuan Liu, Jianglai Liu, Xiang Liu, Wolfgang Lorenzon, Yugang Ma, Yajun Mao, Kaixuan Ni, Kirill Pushkin, Xiangxiang Ren, Michael Schubnell, Manbin Shen, Yuji Shi, Scott Stephenson, Hongwei Wang, Jiming Wang, Meng Wang, Siguang Wang, Xuming Wang, Zhou Wang, Shiyong Wu, Mengjiao Xiao, Pengwei Xie, Binbin Yan, Yinghui You, Xionghui Zeng, Tao Zhang, Li Zhao, Xiaopeng Zhou, , Zhonghua Zhu
    Aug. 20, 2015 hep-ex, physics.ins-det, astro-ph.IM
    ... ... ... ... ... ...
    We report the results of a weakly-interacting massive particle (WIMP) dark matter search using the full 80.1\;live-day exposure of the first stage of the PandaX experiment (PandaX-I) located in the China Jin-Ping Underground Laboratory. The PandaX-I detector has been optimized for detecting low-mass WIMPs, achieving a photon detection efficiency of 9.6\%. With a fiducial liquid xenon target mass of 54.0\,kg, no significant excess event were found above the expected background. A profile likelihood analysis confirms our earlier finding that the PandaX-I data disfavor all positive low-mass WIMP signals reported in the literature under standard assumptions. A stringent bound on the low mass WIMP is set at WIMP mass below 10\,GeV/c$^2$, demonstrating that liquid xenon detectors can be competitive for low-mass WIMP searches.
  • First dark matter search results from the PandaX-I experiment (1408.5114)

    PandaX Collaboration: Mengjiao Xiao, Xiang Xiao, Li Zhao, Xiguang Cao, Xun Chen, Yunhua Chen, Xiangyi Cui, Deqing Fang, Changbo Fu, Karl L. Giboni, Haowei Gong, Guodong Guo, Jie Hu, Xingtao Huang, Xiangdong Ji, Yonglin Ju, Siao Lei, Shaoli Li, Qing Lin, Huaxuan Liu, Jianglai Liu, Xiang Liu, Wolfgang Lorenzon, Yugang Ma, Yajun Mao, Kaixuan Ni, Kirill Pushkin, Xiangxiang Ren, Michael Schubnell, Manbing Shen, Scott Stephenson, Andi Tan, Greg Tarle, Hongwei Wang, Jimin Wang, Meng Wang, Xuming Wang, Zhou Wang, Yuehuan Wei, Shiyong Wu, Pengwei Xie, Yinghui You, Xionghui Zeng, Hua Zhang, Tao Zhang, Zhonghua Zhu
    Sept. 4, 2014 hep-ex, physics.ins-det, astro-ph.IM
    ... ... ... ... ... ...
    We report on the first dark-matter (DM) search results from PandaX-I, a low threshold dual-phase xenon experiment operating at the China Jinping Underground Laboratory. In the 37-kg liquid xenon target with 17.4 live-days of exposure, no DM particle candidate event was found. This result sets a stringent limit for low-mass DM particles and disfavors the interpretation of previously-reported positive experimental results. The minimum upper limit, $3.7\times10^{-44}$\,cm$^2$, for the spin-independent isoscalar DM-particle-nucleon scattering cross section is obtained at a DM-particle mass of 49\,GeV/c$^2$ at 90\% confidence level.