We searched for the $CP$-violating rare decay of neutral kaon, $K_{L} \to
\pi^0 \nu \overline{\nu}$, in data from the first 100 hours of physics running
in 2013 of the J-PARC KOTO experiment. One candidate event was observed while
$0.34\pm0.16$ background events were expected. We set an upper limit of
$5.1\times10^{-8}$ for the branching fraction at the 90\% confidence level
(C.L.). An upper limit of $3.7\times10^{-8}$ at the 90\% C.L. for the $K_{L}
\to \pi^{0} X^{0}$decay was also set for the first time, where $X^{0}$ is an
invisible particle with a mass of 135 MeV/$c^{2}$.
-
The KOTO ($K^0$ at Tokai) experiment aims to observe the CP-violating rare
decay $K_L \rightarrow \pi^0 \nu \bar{\nu}$ by using a long-lived neutral-kaon
beam produced by the 30 GeV proton beam at the Japan Proton Accelerator
Research Complex. The $K_L$ flux is an essential parameter for the measurement
of the branching fraction. Three $K_L$ neutral decay modes, $K_L \rightarrow
3\pi^0$, $K_L \rightarrow 2\pi^0$, and $K_L \rightarrow 2\gamma$ were used to
measure the $K_L$ flux in the beam line in the 2013 KOTO engineering run. A
Monte Carlo simulation was used to estimate the detector acceptance for these
decays. Agreement was found between the simulation model and the experimental
data, and the remaining systematic uncertainty was estimated at the 1.4\%
level. The $K_L$ flux was measured as $(4.183 \pm 0.017_{\mathrm{stat.}} \pm
0.059_{\mathrm{sys.}}) \times 10^7$ $K_L$ per $2\times 10^{14}$ protons on a
66-mm-long Au target.
-
The Outer-Edge Veto (OEV) counter subsystem for extra-photon detection from
the backgrounds for the? $K^0_L\rightarrow\pi^0\nu\bar{\nu}$ decay is located
at the outer edge of the endcap CsI calorimeter of the KOTO experiment at
J-PARC. The subsystem is composed of 44 counters with different cross-sectional
shapes. All counters are made of lead and scintillator plates and read out
through wavelength-shifting fibers. In this paper, we discuss the design and
performances of the OEV counters under heavy load ($\sim8$ tons/m$^2$) in
vacuum. For 1-MeV energy deposit, the average light yield and time resolution
are 20.9 photo-electrons and 1.5 ns, respectively. Although no pronounced peak
by minimum-ionizing particles is observed in the energy distributions, an
energy calibration method with cosmic rays works well in monitoring the gain
stability with an accuracy of a few percent.
-
The charge transport in the copper-oxygen chain/ladder layers of
(La,Y)y(Sr,Ca)14-yCu24O41 is investigated along two crystallographic directions
in the temperature range from 50 K to 700 K and for doping levels from y ~= 6
(number of holes nh < 1) to y = 0 (number of holes nh = 6). A crossover from a
one-dimensional hopping transport along the chains for y >= 3 to a
quasi-two-dimensional charge conduction in the ladder planes for y <~ 2 is
observed. This is attributed to a partial hole transfer from chains to ladders
when the hole doping exceeds nh ~= 4 and approaches fully doped value n_h = 6.
For y <~ 2 a weak dielectric relaxation at radio-frequencies and a microwave
mode are detected, which might be recognized as signatures of a charge-density
wave phase developed at short length scales in the ladders planes.
-
We present an exactly solvable model for queue dynamics. Our model is very
simple but provides the essential property for such dynamics. As an example,
the model has the traveling cluster solution as well as the homogeneous flow
solution. The model is the limiting case of Optimal Velocity (OV) model, which
is proposed for the car following model to induce traffic jam spontaneously.