POLAR is a new satellite-born detector aiming to measure the polarization of
an unprecedented number of Gamma-Ray Bursts in the 50-500 keV energy range. The
instrument, launched on-board the Tiangong-2 Chinese Space lab on the 15th of
September 2016, is designed to measure the polarization of the hard X-ray flux
by measuring the distribution of the azimuthal scattering angles of the
incoming photons. A detailed understanding of the polarimeter and specifically
of the systematic effects induced by the instrument's non-uniformity are
required for this purpose. In order to study the instrument's response to
polarization, POLAR underwent a beam test at the European Synchrotron Radiation
Facility in France. In this paper both the beam test and the instrument
performance will be described. This is followed by an overview of the Monte
Carlo simulation tools developed for the instrument. Finally a comparison of
the measured and simulated instrument performance will be provided and the
instrument response to polarization will be presented.
-
POLAR is space-borne detector designed for a precise measurement of gamma-ray
polarization of the prompt emissions of Gamma-Ray Bursts in the energy range 50
keV - 500 keV. POLAR is a compact Compton polarimeter consisting of 40$\times$
40 plastic scintillator bars read out by 25 multi-anode PMTs. In May 2015, we
performed a series of tests of the POLAR flight model with 100\% polarized
x-rays beams at the European Synchrotron Radiation Facility beam-line ID11
aming to study thresholds, crosstalk between channels and responses of POLAR
flight model to polarized X-ray beams. In this paper we present the data
analysis method and some analysis results. According the results, POLAR FM has
good polarimetric capabilities.
-
As a space-borne detector POLAR is designed to conduct hard X-ray
polarization measurements of gamma-ray bursts on the statistically significant
sample of events and with an unprecedented accuracy. During its development
phase a number of tests, calibrations runs and verification measurements were
carried out in order to validate instrument functionality and optimize
operational parameters. In this article we present results on gain optimization
togeter with verification data obtained in the course of broad laboratory and
environmental tests. In particular we focus on exposures to the $^{137}$Cs
radioactive source and determination of the gain dependence on the high voltage
for all 1600 detection channels of the polarimeter. Performance of the
instrument is described in detail with respect to the dynamic range, energy
resolution and temperature dependence. Gain optimization algorithms and
response non-uniformity studies are also broadly discussed. Results presented
below constitute important parts for development of the POLAR calibration and
operation database.
-
Motivated by recent photoemission experiments on the surface of topological
insulators we compute the spectrum of driven topological surface excitations in
the presence of an external light source. We completely characterize the
spectral function of these non-equilibrium electron excitations for both linear
and circular polarizations of the incident light. We find that in the latter
case, the circularly polarized light gaps out the surface states, whereas
linear polarization gives rise to an anisotropic metal with multiple Dirac
cones. We compare the sizes of the gaps with recent pump-probe photoemission
measurements and find good agreement. We also identify theoretically several
new features in the time-dependent spectral function, such as shadow Dirac
cones.