• Login
    Sort by: Relevance Date Users's collections Twitter
    Group by: Day Week Month Year All time
Based on the idea and the provided source code of Andrej Karpathy (arxiv-sanity)
2:3 1:1 3:2
  • Direct mass measurements of neutron-rich $^{86}$Kr projectile fragments and the persistence of neutron magic number $N$ = 32 in Sc isotopes (1603.06404)

    Xing Xu, Meng Wang, Yu-hu Zhang, Hu-shan Xu, Peng Shuai, Xiao-lin Tu, Yuri A. Litvinov, Xiao-hong Zhou, Bao-hua Sun, You-jin Yuan, Jia-wen Xia, Jian-cheng Yang, KLaus Blaum, Rui-jiu Chen, Xiang-cheng Chen, Chao-yi Fu, Zhuang Ge, Zheng-guo Hu, Wen-jia Huang, Da-wei Liu, Yi-hua Lam, Xin-wen Ma, Rui-shi Mao, T. Uesaka, Guo-ging Xiao, Yuan-ming Xing, T. Yamaguchi, Y. Yamaguchi, Qi Zeng, Xin-liang Yan, Hong-wei Zhao, Tie-cheneg Zhao, Wei Zhang, Wen-long Zhan
    March 21, 2016 nucl-ex
    ... ... ... ... ... ...
    In this paper, we present direct mass measurements of neutron-rich $^{86}$Kr projectile fragments conducted at the HIRFL-CSR facility in Lanzhou by employing the Isochronous Mass Spectrometry (IMS) method. The new mass excesses of $^{52-54}$Sc nuclides are determined to be -40492(82), -38928(114), -34654(540) keV, which show a significant increase of binding energy compared to the reported ones in the Atomic Mass Evaluation 2012 (AME12). In particular, $^{53}$Sc and $^{54}$Sc are more bound by 0.8 MeV and 1.0 MeV, respectively. The behavior of the two neutron separation energy with neutron numbers indicates a strong sub-shell closure at neutron number $N$ = 32 in Sc isotopes.
  • A data analysis method for isochronous mass spectrometry using two time-of-flight detectors at CSRe (1603.07169)

    Xing Xu, Meng Wang, Peng Shuai, Rui-Jiu Chen, Xin-Liang Yan, Yu-Hu Zhang, You-Jin Yuan, Hu-Shan Xu, Xiao-Hong Zhou, Yuri A. Litvinov, Sergey Litvinov, Xiao-Lin Tu, Xiang-Cheng Chen, Chao-Yi Fu, Wen-Wen Ge, Zhuang Ge, Xue-Jing Hu, Wen-Jia Huang, Da-Wei Liu, Yuan-Ming Xing, Qi Zeng, Wei Zhang
    March 21, 2016 nucl-ex, physics.ins-det, physics.acc-ph
    ... ... ... ... ... ...
    The concept of isochronous mass spectrometry (IMS) applying two time-of-flight (TOF) detectors originated many years ago at GSI. However, the corresponding method for data analysis has never been discussed in detail. Recently, two TOF detectors have been installed at CSRe and the new working mode of the ring is under test. In this paper, a data analysis method for this mode is introduced and tested with a series of simulations. The results show that the new IMS method can significantly improve mass resolving power via the additional velocity information of stored ions. This improvement is especially important for nuclides with Lorentz factor $\gamma$-value far away from the transition point $\gamma _t$ of the storage ring CSRe.