-
Biophysical modelling of diffusion MRI is necessary to provide specific
microstructural tissue properties. However, estimating model parameters from
data with limited diffusion gradient strength, such as clinical scanners, has
proven unreliable due to a shallow optimization landscape. On the other hand,
estimation of diffusion kurtosis (DKI) parameters is more robust as the
clinical acquisitions typically probe a regime in which the associated 4th
order cumulant expansion is adequate; however, its parameters are not
microstructurally specific a priori. Given an appropriate biophysical model,
its parameters may be connected to DKI parameters, but it was previously shown
that at the DKI level, it still does not provide sufficient information to
uniquely determine all model parameters. Earlier work has shown that by
neglecting axonal dispersion, this parameter degeneracy reduces to the question
of whether intra-axonal diffusivity is larger than or smaller than extra-axonal
diffusivity. Here we develop a model of diffusion in spinal cord white matter
including axonal dispersion and demonstrate stable estimation of all model
parameters from DKI. By employing the recently developed fast axisymmetric DKI,
we use stimulated echo acquisition mode to collect data over an unprecedented
diffusion time range with very narrow diffusion gradient pulses, enabling
finely resolved measurements of diffusion time dependence of both net diffusion
and kurtosis metrics, as well as model intra- and extra-axonal diffusivities,
and axonal dispersion. Our results demonstrate substantial time dependence of
all parameters except volume fractions, and the additional time dimension
provides support for intra-axonal diffusivity to be larger than extra-axonal
diffusivity in spinal cord white matter, although not unambiguously. We compare
our findings to predictions from effective medium theory.
-
Background: The deep inspiration breath hold technique (DIBH) is widely used
for left-sided breast radiotherapy (RT), in order to reduce the dose to the
heart and the risk of cardiotoxicity. The volumetric arc therapy (VMAT)
technique increases the dose conformity to the planning target volume (PTV). We
hereby describe the procedure of combining VMAT and DIBH without a dedicated
equipment, and report a dosimetric study related on our implemented technique.
Methods: The DIBH technique is based on voluntary breath hold of the patient
which is controlled by a laser on tattoo marks. Patients were selected
depending their ability to breath hold for 25s, and VMAT plans were optimized
with an arrangement of 4 arcs with a maximum delivery time of 20s each. A
retrospective dosimetric study was undertaken on 30 patients treated with this
technique: 10 received local (whole breast) RT (L-RT) with a simultaneous
integrated boost (SIB), 10 a locoregional (LR)RT of the chestwall, 10 a LR RT
of the whole breast with SIB. For these patients, their DIBH-VMAT treatment
plans were compared to free breathing (FB) VMAT plans, and dose characteristics
of PTV and organs at risk (OAR) were evaluated. Results: The PTV coverage was
identical among plans under DIBH or FB. The mean heart dose was reduced from
2.8+/-0.9Gy in FB to 1.8+/-0.6Gy in DIBH for local RT, and reduced from
3.4+/-1.3Gy in FB to 2.2+/-0.5Gy in DIBH for LR-RT. The ipsilateral mean lung
dose was reduced by a factor of 12% for LR-RT, but remained unchanged for L-RT
with DIBH-VMAT compared to FB treatment. No significant differences were
observed in the mean dose of contra-lateral organs with either DIBH or FB VMAT
techniques. Conclusion: The VMAT-DIBH technique performed without a dedicated
breath hold equipment, provided important dose reductions at the heart, while
preserving the ipsilateral lung and contralateral normal tissues.
-
The importance of the excitation bandwidth is well known in diagnostic
ultrasound imaging. However, the effect of excitation bandwidth in therapeutic
applications of microbubbles has been mostly overlooked. A majority of contrast
agent production techniques generate polydisperse microbubble populations, so a
wide range of resonance frequencies exist. Therefore, wideband excitation is
necessary to fully utilize microbubble resonance behavior and maximize the
reradiated energy from a microbubble population, both for imaging and therapy.
Oscillations of sixty SonoVue microbubbles in proximity of a rigid boundary
were captured on a high speed camera at 3 Mfps, excited with a peak negative
pressure of 50 kPa at 1 MHz. Measurements were analyzed according to their peak
radiated pressure, radial oscillations, root mean squared pressure, and shear
stress generated by microbubbles. Results showed that long duration and
wideband excitation at low intensity levels was preferable for sonoporation,
where microbubbles can be driven in a stable oscillation state without
experiencing inertial cavitation or destruction.
-
Objective:Optoacoustic (photoacoustic) tomography is aimed at reconstructing
maps of the initial pressure rise induced by the absorption of light pulses in
tissue. In practice, due to inaccurate assumptions in the forward model, noise
and other experimental factors, the images are often afflicted by artifacts,
occasionally manifested as negative values. The aim of the work is to develop
an inversion method which reduces the occurrence of negative values and
improves the quantitative performance of optoacoustic imaging. Methods: We
present a novel method for optoacoustic tomography based on an entropy
maximization algorithm, which uses logarithmic regularization for attaining
non-negative reconstructions. The reconstruction image quality is further
improved using structural prior based fluence correction. Results: We report
the performance achieved by the entropy maximization scheme on numerical
simulation, experimental phantoms and in-vivo samples. Conclusion: The proposed
algorithm demonstrates superior reconstruction performance by delivering
non-negative pixel values with no visible distortion of anatomical structures.
Significance: Our method can enable quantitative optoacoustic imaging, and has
the potential to improve pre-clinical and translational imaging applications.
-
In projection-based magnetic particle imaging (MPI) with a field-free-line
(FFL) encoding scheme, projection data are usually acquired by moving the FFL
in a zigzag and a difference in the projection data occurs depending on the
scanning direction of FFL, resulting in blurring in the reconstructed images.
In this study, we developed a method for correcting the blur by deconvolution
using a signal-delay constant ({\xi}). The {\xi} value for correction ({\xi}c)
was determined by acquiring projection data in positive and negative directions
and searching for the {\xi} value which minimized the 2-norm between the
deconvolved projection data in the two directions. We validated our method
using a line and A-shaped phantoms for various velocities of FFL (vFFL). The
{\xi}c value correlated linearly with vFFL. The full width at half maximum of
the line phantom decreased significantly after correction of the blur. The
effectiveness of our method was also confirmed by the MPI images of the
A-shaped phantom. These results suggest that our method will be useful for
enhancing the reliability of projection-based MPI.
-
We developed a method for measuring blood coagulation using superparamagnetic
iron oxide nanoparticles (SPIONs) and an alternating magnetic field (AMF). The
3rd and 5th harmonic signals from SPIONs mixed with blood induced by AMF were
detected using a gradiometer coil. Blood coagulation was induced artificially
by adding CaCl2 solution to whole blood of sheep at various temperatures and
hematocrits. We calculated the coagulation rate (k) and normalized signal
intensity at infinite time (Sinf) by fitting the time course of the normalized
3rd harmonic signal to S(t)=(1-Sinf)exp(-kt)+Sinf. The k values increased
significantly with increasing temperature and decreased significantly with
increasing hematocrit. The Sinf values decreased significantly with increasing
temperature and tended to increase with increasing hematocrit. Blood
anticoagulation was induced by adding heparin to the whole blood sampled from
mice. There were significant differences in both the 3rd and 5th harmonic
signals between groups with and without heparin at 25 min or more after adding
heparin. We also calculated the 3rd and 5th harmonic signals for viscosities
ranging from 0.001 to 1 kg/m/s, with an assumption that the magnetization and
particle size distribution of SPIONs obey the Langevin theory of paramagnetism
and log-normal distribution, respectively. The 3rd and 5th harmonic signals
increased slowly with increasing viscosity and had peaks at approximately 0.015
and 0.025 kg/m/s, respectively. After these peaks, they decreased monotonically
with increasing viscosity. These results confirm the rationale of our method.
In conclusion, our method will be useful for measuring blood coagulation and
anticoagulation and for studying their processes.
-
Purpose: The analysis of optimized spin ensemble trajectories for relaxometry
in the hybrid state.
Methods: First, we constructed visual representations to elucidate the
differential equation that governs spin dynamics in hybrid state. Subsequently,
numerical optimizations were performed to find spin ensemble trajectories that
minimize the Cram\'er-Rao bound for $T_1$-encoding, $T_2$-encoding, and their
weighted sum, respectively, followed by a comparison of the Cram\'er-Rao bounds
obtained with our optimized spin-trajectories, as well as Look-Locker and
multi-spin-echo methods. Finally, we experimentally tested our optimized spin
trajectories with in vivo scans of the human brain.
Results: After a nonrecurring inversion segment on the southern hemisphere of
the Bloch sphere, all optimized spin trajectories pursue repetitive loops on
the northern half of the sphere in which the beginning of the first and the end
of the last loop deviate from the others. The numerical results obtained in
this work align well with intuitive insights gleaned directly from the
governing equation. Our results suggest that hybrid-state sequences outperform
traditional methods. Moreover, hybrid-state sequences that balance $T_1$- and
$T_2$-encoding still result in near optimal signal-to-noise efficiency. Thus,
the second parameter can be encoded at virtually no extra cost.
Conclusion: We provide insights regarding the optimal encoding processes of
spin relaxation times in order to guide the design of robust and efficient
pulse sequences. We find that joint acquisitions of $T_1$ and $T_2$ in the
hybrid state are substantially more efficient than sequential encoding
techniques.
-
With the advancement of treatment modalities in radiation therapy for cancer
patients, outcomes have improved, but at the cost of increased treatment plan
complexity and planning time. The accurate prediction of dose distributions
would alleviate this issue by guiding clinical plan optimization to save time
and maintain high quality plans. We have modified a convolutional deep network
model, U-net (originally designed for segmentation purposes), for predicting
dose from patient image contours of the planning target volume (PTV) and organs
at risk (OAR). We show that, as an example, we are able to accurately predict
the dose of intensity-modulated radiation therapy (IMRT) for prostate cancer
patients, where the average Dice similarity coefficient is 0.91 when comparing
the predicted vs. true isodose volumes between 0% and 100% of the prescription
dose. The average value of the absolute differences in [max, mean] dose is
found to be under 5% of the prescription dose, specifically for each structure
is [1.80%, 1.03%](PTV), [1.94%, 4.22%](Bladder), [1.80%, 0.48%](Body), [3.87%,
1.79%](L Femoral Head), [5.07%, 2.55%](R Femoral Head), and [1.26%,
1.62%](Rectum) of the prescription dose. We thus managed to map a desired
radiation dose distribution from a patient's PTV and OAR contours. As an
additional advantage, relatively little data was used in the techniques and
models described in this paper.
-
Quantitative nuclear magnetic resonance imaging (MRI) shifts more and more
into the focus of clinical research. Especially determination of relaxation
times without/and with contrast agents becomes the foundation of tissue
characterization, e.g. in cardiac MRI for myocardial fibrosis. Techniques which
assess longitudinal relaxation times rely on repetitive application of readout
modules, which are interrupted by free relaxation periods, e.g. the Modified
Look-Locker Inversion Recovery = MOLLI sequence. These discontinuous sequences
reveal an apparent relaxation time, and, by techniques extrapolated from
continuous readout sequences, the real T1 is determined. What is missing is a
rigorous analysis of the dependence of the apparent relaxation time on its real
partner, readout sequence parameters and biological parameters as heart rate.
This is provided in this paper for the discontinuous balanced steady state free
precession (bSSFP) and spoiled gradient echo readouts. It turns out that the
apparente longitudinal relaxation rate is the time average of the relaxation
rates during the readout module, and free relaxation period. Knowing the heart
rate our results vice versa allow to determine the real T1 from its measured
apparent partner.
-
Objective: High-intensity focused ultrasound (HIFU) therapy can be used for
non-invasive treatment of kidney (renal) cancer, but the clinical outcomes have
been variable. In this study, the efficacy of renal HIFU therapy was studied
using nonlinear acoustic and thermal simulations in three patients. Methods:
The acoustic simulations were conducted with and without refraction in order to
investigate its effect on the shape, size and pressure distribution at the
focus. The values for the attenuation, sound speed, perfusion and thermal
conductivity of the kidney were varied over the reported ranges to determine
the effect of variability on heating. Furthermore, the phase aberration was
studied in order to quantify the underlying phase shifts using a second order
polynomial function. Results: The ultrasound field intensity was found to drop
on average 11.1 dB with refraction and 6.4 dB without refraction. Reflection at
tissue interfaces was found to result in a loss less than 0.1 dB. Focal point
splitting due to refraction significantly reduced the heating efficacy.
Perfusion did not have a large effect on heating during short sonication
durations. Small changes in temperature were seen with varying attenuation and
thermal conductivity, but no visible changes were present with sound speed
variations. The aberration study revealed an underlying trend in the spatial
distribution of the phase shifts. Conclusion: The results show that the
efficacy of HIFU therapy in the kidney could be improved with aberration
correction. Significance: A method is proposed by which patient specific
pre-treatment calculations could be used to overcome the aberration and
therefore make ultrasound treatment possible.
-
Robustness against data inconsistencies, imaging artifacts and acquisition
speed are crucial factors limiting the possible range of applications for
magnetic resonance imaging (MRI). Therefore, we report a novel calibrationless
parallel imaging technique which simultaneously estimates coil profiles and
image content in a relaxed forward model. Our method is robust against a wide
class of data inconsistencies, minimizes imaging artifacts and is comparably
fast combining important advantages of many conceptually different
state-of-the-art parallel imaging approaches. Depending on the experimental
setting, data can be undersampled well below the Nyquist limit. Here, even high
acceleration factors yield excellent imaging results while being robust to
noise and the occurrence of phase singularities in the image domain, as we show
on different data. Moreover, our method successfully reconstructs acquisitions
with insufficient field-of-view. We further compare our approach to ESPIRiT and
SAKE using spin-echo and gradient echo MRI data from the human head and knee.
In addition, we show its applicability to non-Cartesian imaging on radial FLASH
cardiac MRI data. Using theoretical considerations, we show that ENLIVE can be
related to a low-rank formulation of blind multi-channel deconvolution,
explaining why it inherently promotes low-rank solutions.
-
Magnetic Particle Imaging (MPI) is an emerging imaging modality that maps the
spatial distribution of magnetic nanoparticles. The x-space reconstruction in
MPI results in highly blurry images, where the resolution depends on both
system parameters and nanoparticle type. Previous techniques to counteract this
blurring rely on the knowledge of the imaging point spread function (PSF),
which may not be available or may require additional measurements. This work
proposes a blind deconvolution algorithm for MPI to recover the precise spatial
distribution of nanoparticles. The proposed algorithm exploits the observation
that the imaging PSF in MPI has zero phase in Fourier domain. Thus, even though
the reconstructed images are highly blurred, phase remains unaltered. We
leverage this powerful property to iteratively enforce consistency of phase and
bounded l1 energy information, using an orthogonal Projections Onto Convex Sets
(POCS) algorithm. To demonstrate the method, comprehensive simulations were
performed without and with nanoparticle relaxation effects, and at various
noise levels. In addition, imaging experiments were performed on an in-house
MPI scanner using a three-vial phantom that contained different nanoparticle
types. Image quality was compared with conventional deconvolution methods,
Wiener deconvolution and Lucy-Richardson method, which explicitly rely on the
knowledge of PSF. Both the simulation results and experimental imaging results
show that the proposed blind deconvolution algorithm outperforms the
conventional deconvolution methods. Without utilizing the imaging PSF, the
proposed algorithm improves image quality and resolution even in the case of
different nanoparticle types, while displaying reliable performance against
loss of the fundamental harmonic, nanoparticle relaxation effects, and noise.
-
In the Alvarez-Macovski method, the line integrals of the x-ray basis set
coefficients are computed from measurements with multiple spectra. An important
question is whether the transformation from measurements to line integrals is
invertible. This paper presents a proof that for a system with two spectra and
a photon counting detector, pileup does not affect the invertibility of the
system. If the system is invertible with no pileup, it will remain invertible
with pileup although the reduced Jacobian may lead to increased noise.
-
Recently, some authors have shown that a DNA molecule produces
electromagnetic signals and communicates with other DNA molecules or other
molecules. In fact, a DNA acts like a receiver or transmitter of radio waves.
In this paper, we suggest a mathematical model for the DNA molecule and use of
its communication to cure some diseases like cancer. In this model, first, by
using concepts from string theory and M-theory, we calculate the energy of a
DNA in terms of interactions between free electrons and bound electrons. We
show that when a DNA is damaged, its energy changes and an extra current is
produced. This extra current causes the electromagnetic signals of a damaged
DNA molecule to be different when compared to the electromagnetic signals of a
normal DNA molecule. The electromagnetic signals of a damaged DNA molecule
induces an extra current in a normal DNA molecule and leads to its destruction.
By sending crafted electromagnetic signals to normal DNA molecules and inducing
an opposite current with respect to this extra current, we can prevent the
destruction of normal DNA. Finally, we argue that the type of packing of DNA in
chromosomes of men and women are different. This causes radiated waves from
DNAs of men and women to have opposite signs and cancel the effect of each
other in a pair. Using this property, we suggest another mechanism to cancel
the effect of extra waves, which are produced by DNAs in cancer cells of a male
or a female, by extra waves which are produced by DNAs in similar cells of a
female or a male and prevent the progression of the disease.
-
Recent studies have shown potential for using polarisation sensitive optical
coherence tomography (PS-OCT) to study cartilage morphology, and to be
potentially used as an in-vivo, non-invasive tool for detecting osteoarthritic
changes. However, there has been relatively limited ability of this method to
quantify the subtle changes that occur in the early stages of cartilage
degeneration. An established mechanical indenting technique that has previously
been used to examine the microstructural response of articular cartilage was
employed to fix the bovine samples in an indented state. The samples were
subject to creep loading with a constant compressive stress of 4.5 MPa and,
when imaged using PS-OCT, enabled birefringent banding patterns to be observed.
The magnitude of the birefringence was quantified using the birefringence
coefficient (BRC) and statistical analysis revealed that PS-OCT is able to
detect and quantify significant changes between healthy and early
osteoarthritic cartilage (p<0.001). This presents a novel utilization of PS-OCT
for future development as an in-vivo assessment tool.
-
Reliability theory is used to assess the sensitivity of a passive flexion and
active flexion of the human lower leg Finite Element (FE) models with Total
Knee Replacement (TKR) to the variability in the input parameters of the
respective FE models. The sensitivity of the active flexion simulating the
stair ascent of the human lower leg FE model with TKR was presented before in
[1,2] whereas now in this paper a comparison is made with the passive flexion
of the human lower leg FE model with TKR. First, with the Monte Carlo
Simulation Technique (MCST), a number of randomly generated input data of the
FE model(s) are obtained based on the normal standard deviations of the
respective input parameters. Then a series of FE simulations are done and the
output kinematics and peak contact pressures are obtained for the respective FE
models (passive flexion and/or active flexion models). Seven output performance
measures are reported for the passive flexion model and one more parameter was
reported for the active flexion FE model (patello-femoral peak contact
pressure) in [1]. A sensitivity study will be performed based on the Response
Surface Method (RSM) to identify the key parameters that influence the
kinematics and peak contact pressures of the passive flexion FE model. Another
two MCST and RSM-based probabilistic FE analyses will be performed based on a
reduced list of 19 key input parameters. In total 4 probabilistic FE analyses
will be performed: 2 probabilistic FE analyses (MCST and RSM) based on an
extended set of 78 input variables and another 2 probabilistic FE analyses
(MCST and RSM) based on a reduced set of 19 input variables. Due to the likely
computation cost in order to make hundreds of FE simulations with MCST, a
high-performance and distributed computing system will be used for the passive
flexion FE model the same as it was used for the active flexion FE model in
[1].
-
Single-domain ferromagnetic nanoparticle systems can be used to transfer
energy from a time-dependent magnetic field into their environment. This local
heat generation, i.e., magnetic hyperthermia, receives applications in cancer
therapy which requires the enhancement of the energy loss. A possible way to
improve the efficiency is to chose a proper type of applied field, e.g., a
rotating instead of an oscillating one. The latter case is very well studied
and there is an increasing interest in the literature to investigate the former
although it is still unclear under which circumstances the rotating applied
field can be more favourable than the oscillating one. The goal of this work is
to incorporate the presence of a static field and to perform a systematic study
of the non-linear dynamics of the magnetisation in the framework of the
deterministic Landau-Lifshitz-Gilbert equation in order to calculate energy
losses. Two cases are considered: the static field is either assumed to be
perpendicular to the plane of rotation or situated in the plane of rotation. In
the latter case a significant increase in the energy loss/cycle is observed if
the magnitudes of the static and the rotating fields have a certain ratio (e.g.
it should be one for isotropic nanoparticles). It can be used to
"super-localise" the heat transfer: in case of an inhomogeneous applied static
field, tissues are heated up only where the magnitudes of the static and
rotating fields reach the required ratio.
-
While the emerging evidence indicates that the pathogenesis of Parkinson's
disease (PD) is strongly correlated to the accumulation of alpha-synuclein
({\alpha}-syn) aggregates, there has been no clinical success in
anti-aggregation agents for the disease to date. Here we show that graphene
quantum dots (GQDs) exhibit anti-amyloid activity via direct interaction with
{\alpha}-syn. Employing biophysical, biochemical, and cell-based assays as well
as molecular dynamics (MD) simulation, we find that GQDs have notable potency
in not only inhibiting fibrillization of {\alpha}-syn but also disaggregating
mature fibrils in a time-dependent manner. Remarkably, GQDs rescue neuronal
death and synaptic loss, reduce Lewy body (LB)/Lewy neurite (LN) formation,
ameliorate mitochondrial dysfunctions, and prevent neuron-to-neuron
transmission of {\alpha}-syn pathology induced by {\alpha}-syn preformed
fibrils (PFFs) in neurons. In addition, in vivo administration of GQDs protects
against {\alpha}-syn PFFs-induced loss of dopamine neurons, LB/LN pathology,
and behavioural deficits through the penetration of the blood-brain barrier
(BBB). The finding that GQDs function as an anti-aggregation agent provides a
promising novel therapeutic target for the treatment of PD and related
{\alpha}-synucleinopathies.
-
High intensity focused ultrasound is a non-invasive method for treatment of
diseased tissue that uses a beam of ultrasound to generate heat within a small
volume. A common challenge in application of this technique is that
heterogeneity of the biological medium can defocus the ultrasound beam. Here we
reduce the problem of refocusing the beam to the inverse problem of estimating
the acoustic aberration due to the biological tissue from acoustic radiative
force imaging data. We solve this inverse problem using a Bayesian framework
with a hierarchical prior and solve the inverse problem using a
Metropolis-within-Gibbs algorithm. The framework is tested using both synthetic
and experimental datasets. We demonstrate that our approach has the ability to
estimate the aberrations using small datasets, as little as 32 sonication
tests, which can lead to significant speedup in the treatment process.
Furthermore, our approach is compatible with a wide range of sonication tests
and can be applied to other energy-based measurement techniques.
-
Purpose: To develop a simple and robust tool for the estimation of gradient
delays from highly undersampled radial k-space data. Theory: In radial imaging
gradient delays induce parallel and orthogonal trajectory shifts, which can be
described using an ellipse model. The intersection points of the radial spokes,
which can be estimated by spoke-by-spoke comparison of k-space samples,
distinctly determine the parameters of the ellipse. Using the proposed method
(RING), these parameters can be obtained using a least-squares fit and utilized
for the correction of gradient delays. Methods: The functionality and accuracy
of the proposed RING method is validated and compared to correlation-based
gradient-delay estimation from opposing spokes using numerical simulations,
phantom and in vivo heart measurements. Results: In all experiments, RING
robustly provides accurate gradient delay estimations even for as few as three
radial spokes. Conclusion: The simple and straightforward to implement RING
method provides accurate gradient delay estimation for highly undersampled
radial imaging. Keywords: trajectory correction, radial imaging, gradient
delay, artifacts, system imperfections, RING}
-
Scatter can account for large errors in cone-beam CT (CBCT) due to its wide
field of view, and its complicated nature makes its compensation difficult.
Iterative polyenergetic reconstruction algorithms offer the potential to
provide quantitative imaging in CT, but they are usually incompatible with
scatter contaminated measurements. In this work, we introduce a polyenergetic
convolutional scatter model that is directly fused into the reconstruction
process, and exploits information readily available at each iteration for a
fraction of additional computational cost. We evaluate this method with
numerical and real CBCT measurements, and show significantly enhanced electron
density estimation and artefact mitigation over pre-calculated fast adaptive
scatter kernel superposition (fASKS). We demonstrate our approach has two
levels of benefit: reducing the bias introduced by estimating scatter prior to
reconstruction; and adapting to the spectral and spatial properties of the
specimen.
-
In this article, a new conceptual biomedical engineering strategy to tackle
modern disease challenges, termed as liquid metal enabled electrobiology, is
proposed. This generalized and easy going way is based on the physiological
fact that specially administrated electricity would induce a series of
subsequent desired biological effects, either shortly, transitional or
permanently. Owing high compliance within any part of the biological tissues,
the liquid metal would aid to mold a pervasive way to treat physiological or
psychological diseases. As highly conductive and non-toxic multifunctional
flexible materials, such liquid metals (LMs) consist of the core to generate
any requested electric treating fields (ETFields) which can adapt to various
sites inside the human body. The basic mechanisms of electrobiology in
delivering electricity to the target tissues and then inducing expected outputs
for disease treatment are interpreted. The methods toward realizing soft and
conformable electronics based on liquid metal are illustrated. Further, a group
of typical disease challenges were taken to illustrate the basic strategies to
perform liquid metal electrobiology therapy, which include but are not limited
to: tissue electronics, brain disorder, immunotherapy, neural functional
recovery, muscle stimulation, skin rejuvenation, cosmetology and dieting,
artificial organs, cardiac pacing and cancer therapy etc. Some practical issues
involved in the electrobiology for future disease therapy were discussed.
Perspective along this direction to incubate an easy-going biomedical tool for
health care was pointed out.
-
In this paper we propose a new pre-processing technique of
Electroencephalography (EEG) signals produced by motor imagery movements. This
technique results to an accelerated determination of the imagery movement and
the command to carry it out, within the time limits imposed by the requirements
of brain-based real-time control of rehabilitation devices, making thus
feasible to drive these devices according to patient's will. Based on event
related desynchronization and synchronization (ERD/ERS) of motor imagery, the
received patient signal is first subjected to the removal of environmental,
system and interference noise which correspond to normal human activities such
as eye-blinking and cardiac motion. Next, power and energy features of the
processed signal are compared with the same features of classified signals from
an available database and the class to which the processed signal belongs, is
identified. The database classification is done off-line by using the SVM
algorithm.
-
To increase the flexibility and scalability of deep neural networks for image
reconstruction, a framework is proposed based on bandpass filtering. For many
applications, sensing measurements are performed indirectly. For example, in
magnetic resonance imaging, data are sampled in the frequency domain. The
introduction of bandpass filtering enables leveraging known imaging physics
while ensuring that the final reconstruction is consistent with actual
measurements to maintain reconstruction accuracy. We demonstrate this flexible
architecture for reconstructing subsampled datasets of MRI scans. The resulting
high subsampling rates increase the speed of MRI acquisitions and enable the
visualization rapid hemodynamics.
-
Degenerative discopathy is a common pathology which may require spine
surgery. A metallic cylindrical pin is inserted into the vertebral body to
maintain soft tissues and may be used as a reflector of ultrasonic wave to
estimate bone density. The first aim of this paper is to validate a 3D model to
simulate the ultrasonic propagation in a trabecular bone sample in which a
metallic pin has been inserted. We also aim at determining the effect of
changes of bone volume fraction (BV/TV) and of positioning errors on the
quantitative ultrasound (QUS) parameters in this specific configuration. The
approach consists in coupling finite difference time domain simulation with
X-ray microcomputed tomography. The correlation coefficient between
experimental and simulated speed of sound (SOS) (respectively broadband
ultrasonic attenuation (BUA)) was equal to 0.90 (respectively 0.55). The
results show a significant correlation of SOS with BV/TV (R = 0.82), while BUA
values exhibit a non-linear behavior versus BV/TV. The orientation of the pin
should be controlled with an accuracy of around 1{\textdegree} in order to
obtain accurate results. The results indicate that using the ultrasonic wave
reflected by a pin has a potential to estimate the bone density. SOS is more
reliable than BUA due its lower sensitivity to the tilt angle.