-
A novel approach which uses Fibre Bragg Grating (FBG) sensors has been
utilised to assess and monitor the flatness of Gaseous Electron Multipliers
(GEM) foils. The setup layout and preliminary results are presented.
-
We present a novel application of Fiber Bragg Grating (FBG) sensors in the
construction and characterisation of Micro Pattern Gaseous Detector (MPGD),
with particular attention to the realisation of the largest triple (Gas
electron Multiplier) GEM chambers so far operated, the GE1/1 chambers of the
CMS experiment at LHC. The GE1/1 CMS project consists of 144 GEM chambers of
about 0.5 m2 active area each, employing three GEM foils per chamber, to be
installed in the forward region of the CMS endcap during the long shutdown of
LHC in 2108-2019. The large active area of each GE1/1 chamber consists of GEM
foils that are mechanically stretched in order to secure their flatness and the
consequent uniform performance of the GE1/1 chamber across its whole active
surface. So far FBGs have been used in high energy physics mainly as high
precision positioning and re-positioning sensors and as low cost, easy to
mount, low space consuming temperature sensors. FBGs are also commonly used for
very precise strain measurements in material studies. In this work we present a
novel use of FBGs as flatness and mechanical tensioning sensors applied to the
wide GEM foils of the GE1/1 chambers. A network of FBG sensors have been used
to determine the optimal mechanical tension applied and to characterise the
mechanical tension that should be applied to the foils. We discuss the results
of the test done on a full-sized GE1/1 final prototype, the studies done to
fully characterise the GEM material, how this information was used to define a
standard assembly procedure and possible future developments.
-
Gas Electron Multiplier (GEM) technology is being considered for the forward
muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first
implementation is planned for the GE1/1 system in the $1.5 < \mid\eta\mid <
2.2$ region of the muon endcap mainly to control muon level-1 trigger rates
after the second long LHC shutdown. A GE1/1 triple-GEM detector is read out by
3,072 radial strips with 455 $\mu$rad pitch arranged in eight $\eta$-sectors.
We assembled a full-size GE1/1 prototype of 1m length at Florida Tech and
tested it in 20-120 GeV hadron beams at Fermilab using Ar/CO$_{2}$ 70:30 and
the RD51 scalable readout system. Four small GEM detectors with 2-D readout and
an average measured azimuthal resolution of 36 $\mu$rad provided precise
reference tracks. Construction of this largest GEM detector built to-date is
described. Strip cluster parameters, detection efficiency, and spatial
resolution are studied with position and high voltage scans. The plateau
detection efficiency is [97.1 $\pm$ 0.2 (stat)]\%. The azimuthal resolution is
found to be [123.5 $\pm$ 1.6 (stat)] $\mu$rad when operating in the center of
the efficiency plateau and using full pulse height information. The resolution
can be slightly improved by $\sim$ 10 $\mu$rad when correcting for the bias due
to discrete readout strips. The CMS upgrade design calls for readout
electronics with binary hit output. When strip clusters are formed
correspondingly without charge-weighting and with fixed hit thresholds, a
position resolution of [136.8 $\pm$ 2.5 stat] $\mu$rad is measured, consistent
with the expected resolution of strip-pitch/$\sqrt{12}$ = 131.3 $\mu$rad. Other
$\eta$-sectors of the detector show similar response and performance.
-
We demonstrate a novel detection method for the cyclotron resonance frequency
of an electron plasma in a Penning-Malmberg trap. With this technique, the
electron plasma is used as an in situ diagnostic tool for measurement of the
static magnetic field and the microwave electric field in the trap. The
cyclotron motion of the electron plasma is excited by microwave radiation and
the temperature change of the plasma is measured non-destructively by
monitoring the plasma's quadrupole mode frequency. The spatially-resolved
microwave electric field strength can be inferred from the plasma temperature
change and the magnetic field is found through the cyclotron resonance
frequency. These measurements were used extensively in the recently reported
demonstration of resonant quantum interactions with antihydrogen.
-
The CMS GEM collaboration is considering Gas Electron Multipliers (GEMs) for
upgrading the CMS forward muon system in the 1.5<|eta|<2.4 endcap region. GEM
detectors can provide precision tracking and fast trigger information. They
would improve the CMS muon trigger and muon momentum resolution and provide
missing redundancy in the high-eta region. Employing a new faster construction
and assembly technique, we built four full-scale Triple-GEM muon detectors for
the inner ring of the first muon endcap station. We plan to install these or
further improved versions in CMS during the first long LHC shutdown in 2013/14
for continued testing. These detectors are designed for the stringent rate and
resolution requirements in the increasingly hostile environments expected at
CMS after the second long LHC shutdown in 2018/19. The new prototypes were
studied in muon/pion beams at the CERN SPS. We discuss our experience with
constructing the new full-scale production prototypes and present preliminary
performance results from the beam test. We also tested smaller Triple-GEM
prototypes with zigzag readout strips with 2 mm pitch in these beams and
measured a spatial resolution of 73 microns. This readout offers a potential
reduction of channel count and consequently electronics cost for this system
while maintaining high spatial resolution.
-
Recently, antihydrogen atoms were trapped at CERN in a magnetic minimum
(minimum-B) trap formed by superconducting octupole and mirror magnet coils.
The trapped antiatoms were detected by rapidly turning off these magnets,
thereby eliminating the magnetic minimum and releasing any antiatoms contained
in the trap. Once released, these antiatoms quickly hit the trap wall,
whereupon the positrons and antiprotons in the antiatoms annihilated. The
antiproton annihilations produce easily detected signals; we used these signals
to prove that we trapped antihydrogen. However, our technique could be
confounded by mirror-trapped antiprotons, which would produce
seemingly-identical annihilation signals upon hitting the trap wall. In this
paper, we discuss possible sources of mirror-trapped antiprotons and show that
antihydrogen and antiprotons can be readily distinguished, often with the aid
of applied electric fields, by analyzing the annihilation locations and times.
We further discuss the general properties of antiproton and antihydrogen
trajectories in this magnetic geometry, and reconstruct the antihydrogen energy
distribution from the measured annihilation time history.
-
At present, part of the forward RPC muon system of the CMS detector at the
CERN LHC remains uninstrumented in the high-\eta region. An international
collaboration is investigating the possibility of covering the 1.6 < |\eta| <
2.4 region of the muon endcaps with large-area triple-GEM detectors. Given
their good spatial resolution, high rate capability, and radiation hardness,
these micro-pattern gas detectors are an appealing option for simultaneously
enhancing muon tracking and triggering capabilities in a future upgrade of the
CMS detector. A general overview of this feasibility study will be presented.
The design and construction of small (10\times10 cm2) and full-size trapezoidal
(1\times0.5 m2) triple-GEM prototypes will be described. During detector
assembly, different techniques for stretching the GEM foils were tested.
Results from measurements with x-rays and from test beam campaigns at the CERN
SPS will be shown for the small and large prototypes. Preliminary simulation
studies on the expected muon reconstruction and trigger performances of this
proposed upgraded muon system will be reported.
-
Gas Electron Multipliers (GEM) are an interesting technology under
consideration for the future upgrade of the forward region of the CMS muon
system, specifically in the $1.6<| \eta |<2.4$ endcap region. With a
sufficiently fine segmentation GEMs can provide precision tracking as well as
fast trigger information. The main objective is to contribute to the
improvement of the CMS muon trigger. The construction of large-area GEM
detectors is challenging both from the technological and production aspects. In
view of the CMS upgrade we have designed and built the largest full-size
Triple-GEM muon detector, which is able to meet the stringent requirements
given the hostile environment at the high-luminosity LHC. Measurements were
performed during several test beam campaigns at the CERN SPS in 2010 and 2011.
The main issues under study are efficiency, spatial resolution and timing
performance with different inter-electrode gap configurations and gas mixtures.
In this paper results of the performance of the prototypes at the beam tests
will be discussed.
-
Charges in cold, multiple-species, non-neutral plasmas separate radially by
mass, forming centrifugally-separated states. Here, we report the first
detailed measurements of such states in an electron-antiproton plasma, and the
first observations of the separation dynamics in any centrifugally-separated
system. While the observed equilibrium states are expected and in agreement
with theory, the equilibration time is approximately constant over a wide range
of parameters, a surprising and as yet unexplained result. Electron-antiproton
plasmas play a crucial role in antihydrogen trapping experiments.
-
In this paper we introduce the functional centrality as a generalization of
the subgraph centrality. We propose a general method for characterizing nodes
in the graph according to the number of closed walks starting and ending at the
node. Closed walks are appropriately weighted according to the topological
features that we need to measure.
-
We have implemented a cost-effective design for the readout electronics of
both the anode wires and the cathode pads of large area proportional wire
chambers for the HERA-B muon system based on the ASD-08 integrated circuit. To
control and monitor the large number of readout channels, we have built a
distributed control system based on Philips Semiconductors' I2C bus and
microcontrollers. To date we have installed about 10800 channels of muon
chambers and electronics. The average single channel noise occupancy is less
than 10**-5, and the detectors have been operated with target interaction rates
as high as 70 MHz.