During the shutdown of the CERN Large Hadron Collider in 2013-2014, an
additional pixel layer was installed between the existing Pixel detector of the
ATLAS experiment and a new, smaller radius beam pipe. The motivation for this
new pixel layer, the Insertable B-Layer (IBL), was to maintain or improve the
robustness and performance of the ATLAS tracking system, given the higher
instantaneous and integrated luminosities realised following the shutdown.
Because of the extreme radiation and collision rate environment, several new
radiation-tolerant sensor and electronic technologies were utilised for this
layer. This paper reports on the IBL construction and integration prior to its
operation in the ATLAS detector.
-
High Energy Particle Physics experiments at the LHC use hybrid silicon
detectors, in both pixel and strip geometry, for their inner trackers. These
detectors have proven to be very reliable and performant. Nevertheless, there
is great interest in the development of depleted CMOS silicon detectors, which
could achieve similar performances at lower cost of production and complexity.
We present recent developments of this technology in the framework of the ATLAS
CMOS demonstrator project. In particular, studies of two active sensors from
LFoundry, CCPD_LF and LFCPIX, and the first fully monolithic prototype MONOPIX
will be shown.
-
Depleted monolithic active pixel sensors (DMAPS), which exploit high voltage
and/or high resistivity add-ons of modern CMOS technologies to achieve
substantial depletion in the sensing volume, have proven to have high radiation
tolerance towards the requirements of ATLAS in the high-luminosity LHC era.
Depleted fully monolithic CMOS pixels with fast readout architectures are
currently being developed as promising candidates for the outer pixel layers of
the future ATLAS Inner Tracker, which will be installed during the phase II
upgrade of ATLAS around year 2025. In this work, two DMAPS prototype designs,
named LF-MonoPix and TJ-MonoPix, are presented. LF-MonoPix was designed and
fabricated in the LFoundry 150~nm CMOS technology, and TJ-MonoPix has been
designed in the TowerJazz 180~nm CMOS technology. Both chips employ the same
readout architecture, i.e. the column drain architecture, whereas different
sensor implementation concepts are pursued. The design of the two prototypes
will be described. First measurement results for LF-MonoPix will also be shown.
-
The recent R&D focus on CMOS sensors with charge collection in a depleted
zone has opened new perspectives for CMOS sensors as fast and radiation hard
pixel devices. These sensors, labelled as depleted CMOS sensors (DMAPS), have
already shown promising performance as feasible candidates for the ATLAS Inner
Tracker (ITk) upgrade, possibly replacing the current passive sensors. A
further step to exploit the potential of DMAPS is to investigate the
suitability of equipping the outer layers of the ATLAS ITk upgrade with fully
monolithic CMOS sensors. This paper presents the development of a depleted
monolithic CMOS pixel sensor designed in the LFoundry 150 nm CMOS technology,
with the focus on design details and simulation results.
-
Precision sound velocity measurements can simultaneously determine binary gas
composition and flow. We have developed an analyzer with custom electronics,
currently in use in the ATLAS inner detector, with numerous potential
applications. The instrument has demonstrated ~0.3% mixture precision for
C3F8/C2F6 mixtures and < 10-4 resolution for N2/C3F8 mixtures. Moderate and
high flow versions of the instrument have demonstrated flow resolutions of +/-
2% F.S. for flows up to 250 l.min-1, and +/- 1.9% F.S. for linear flow
velocities up to 15 ms-1; the latter flow approaching that expected in the
vapour return of the thermosiphon fluorocarbon coolant recirculator being built
for the ATLAS silicon tracker.
-
An upgrade to the ATLAS silicon tracker cooling control system may require a
change from C3F8 (octafluoro-propane) evaporative coolant to a blend containing
10-25% of C2F6 (hexafluoro-ethane). Such a change will reduce the evaporation
temperature to assure thermal stability following radiation damage accumulated
at full LHC luminosity. Central to this upgrade is a new ultrasonic instrument
in which sound transit times are continuously measured in opposite directions
in flowing gas at known temperature and pressure to deduce the C3F8/C2F6 flow
rate and mixture composition. The instrument and its Supervisory, Control and
Data Acquisition (SCADA) software are described in this paper. Several
geometries for the instrument are in use or under evaluation. An instrument
with a pinched axial geometry intended for analysis and measurement of moderate
flow rates has demonstrated a mixture resolution of 3.10-3 for C3F8/C2F6 molar
mixtures with 20%C2F6, and a flow resolution of 2% of full scale for mass flows
up to 30gs-1. In mixtures of widely-differing molecular weight (mw), higher
mixture precision is possible: a sensitivity of <5.10-5 to leaks of C3F8 into
part of the ATLAS tracker nitrogen envelope (mw difference 160) has been seen.
An instrument with an angled sound path geometry has been developed for use at
high fluorocarbon mass flow rates of around 1.2 kgs-1 - corresponding to full
flow in a new 60kW thermosiphon recirculator under construction for the ATLAS
silicon tracker. Extensive computational fluid dynamics studies were performed
to determine the preferred geometry (ultrasonic transducer spacing and
placement, together with the sound crossing angle with respect to the vapour
flow direction). A prototype with 45deg crossing angle has demonstrated a flow
resolution of 1.9% of full scale for linear flow velocities up to 15 ms-1. The
instrument has many potential applications.
-
An upgrade to the ATLAS silicon tracker cooling control system may require a
change from C3F8 (octafluoro-propane) to a blend containing 10-30% of C2F6
(hexafluoro-ethane) to reduce the evaporation temperature and better protect
the silicon from cumulative radiation damage with increasing LHC luminosity.
Central to this upgrade is a new acoustic instrument for the real-time
measurement of the C3F8/C2F6 mixture ratio and flow. The instrument and its
Supervisory, Control and Data Acquisition (SCADA) software are described in
this paper. The instrument has demonstrated a resolution of 3.10-3 for
C3F8/C2F6 mixtures with ~20%C2F6, and flow resolution of 2% of full scale for
mass flows up to 30gs-1. In mixtures of widely-differing molecular weight (mw),
higher mixture precision is possible: a sensitivity of < 5.10-4 to leaks of
C3F8 into the ATLAS pixel detector nitrogen envelope (mw difference 160) has
been seen. The instrument has many potential applications, including the
analysis of mixtures of hydrocarbons, vapours for semi-conductor manufacture
and anaesthesia.
-
The nuclear emulsion target of the CHORUS detector was exposed to the
wide-band neutrino beam of the CERN SPS of 27 GeV average neutrino energy from
1994 to 1997. In total about 100000 charged-current neutrino interactions with
at least one identified muon were located in the emulsion target and fully
reconstructed, using newly developed automated scanning systems. Charmed
particles were searched for by a program recognizing particle decays. The
observation of the decay in nuclear emulsion makes it possible to select a
sample with very low background and minimal kinematical bias. 2013
charged-current interactions with a charmed hadron candidate in the final state
were selected and confirmed through visual inspection. The charm production
rate induced by neutrinos relative to the charged-current cross-section is
measured to be sigma(nu_mu N -> mu- C X)/sigma(CC) = (5.75 +-0.32 stat +-0.30
syst)%. The charm production cross-section as a function of the neutrino energy
is also obtained. The results are in good agreement with previous measurements.
The charm-quark hadronization produces the following charmed hadrons with
relative fractions (in %): f_Dzero = 43.7+-4.5, f_Lambda_c^plus = 19.2+-4.2,
f_Dplus = 25.3+-4.2, and f_D_splus = 11.8+-4.7.
-
A new method for calibrating the hadron response of a segmented calorimeter
is developed and successfully applied to beam test data. It is based on a
principal component analysis of energy deposits in the calorimeter layers,
exploiting longitudinal shower development information to improve the measured
energy resolution. Corrections for invisible hadronic energy and energy lost in
dead material in front of and between the calorimeters of the ATLAS experiment
were calculated with simulated Geant4 Monte Carlo events and used to
reconstruct the energy of pions impinging on the calorimeters during the 2004
Barrel Combined Beam Test at the CERN H8 area. For pion beams with energies
between 20 GeV and 180 GeV, the particle energy is reconstructed within 3% and
the energy resolution is improved by between 11% and 25% compared to the
resolution at the electromagnetic scale.
-
A detailed study is presented of the expected performance of the ATLAS
detector. The reconstruction of tracks, leptons, photons, missing energy and
jets is investigated, together with the performance of b-tagging and the
trigger. The physics potential for a variety of interesting physics processes,
within the Standard Model and beyond, is examined. The study comprises a series
of notes based on simulations of the detector and physics processes, with
particular emphasis given to the data expected from the first years of
operation of the LHC at CERN.
-
A small set of final prototypes of the ATLAS Inner Detector silicon tracker
(Pixel and SCT) were used to take data during the 2004 Combined Test Beam. Data
were collected from runs with beams of different flavour (electrons, pions,
muons and photons) with a momentum range of 2 to 180 GeV/c. Four independent
methods were used to align the silicon modules. The corrections obtained were
validated using the known momenta of the beam particles and were shown to yield
consistent results among the different alignment approaches. From the residual
distributions, it is concluded that the precision attained in the alignment of
the silicon modules is of the order of 5 micrometers in their most precise
coordinate.
-
Limits at 90 % c.l. on the square of the mixing strength |U_tau4|^2 between
nu_tau and a mostly isosinglet heavy neutrino with mass in the range 10-290
MeV/c^2 are reported. The results were derived using the negative result of a
search for neutral particles decaying into two electrons conducted by the CHARM
collaboration in a neutrino beam dump experiment. Upper limits ~10^-4 were
obtained for neutrino masses larger than 160 MeV/c^2.
-
The report summarizes the results of the activities of the Working Group on
Precision Calculations for the Z Resonance at CERN during 1994.