-
The masses of the exotic isotopes $^{210-214}$Ac and $^{210-214}$Ra have been
measured with a multi-reflection time-of-flight mass spectrograph. These
isotopes were obtained in flight as fusion-evaporation products behind the
gas-filled recoil ion separator GARIS-II at RIKEN. The new direct mass
measurements serve as an independent and direct benchmark for existing
$\alpha$-$\gamma$-spectroscopy data in this mass region. Further, new mass
anchor points are set for U and Np nuclei close to the $N=126$ shell closure
for a future benchmark of the $Z=92$ sub-shell for neutron-deficient heavy
isotopes. Our mass results are in general in good agreement with the previously
indirectly-determined mass values. Together with the measurement data, reasons
for possible mass ambiguities from decay-data links between ground states are
discussed.
-
The masses of $^{246}$Es, $^{251}$Fm and the transfermium nuclei
$^{249-252}$Md, and $^{254}$No, produced by hot- and cold-fusion reactions, in
the vicinity of the deformed $N=152$ neutron shell closure, have been directly
measured using a multireflection time-of-flight mass spectrograph. The masses
of $^{246}$Es and $^{249,250,252}$Md were measured for the first time. Using
the masses of $^{249,250}$Md as anchor points for $\alpha$ decay chains, the
masses of heavier nuclei, up to $^{261}$Bh and $^{266}$Mt, were determined.
These new masses were compared with theoretical global mass models and
demonstrated to be in good agreement with macroscopic-microscopic models in
this region. The empirical shell gap parameter $\delta_{2n}$ derived from three
isotopic masses was updated with the new masses and corroborate the existence
of the deformed $N=152$ neutron shell closure for Md and Lr.
-
High-precision mass measurements of $^{63}$Cu, $^{64-66}$Zn, $^{65}$Ga,
$^{65-67}$Ge, $^{67}$As, $^{78,81}$Br, $^{80}$Rb, and $^{79}$Sr were performed
utilizing a multireflection time-of-flight mass spectrograph combined with the
gas-filled recoil ion separator GARIS-II. In the case of $^{65}$Ga, a mass
uncertainty of 2.1 keV, corresponding to a relative precision of $\delta m / m
= 3.5\times10^{-8}$, was obtained and the mass value is in excellent agreement
with the 2016 Atomic Mass Evaluation. For $^{67}$Ge and $^{81}$Br, where masses
were previously deduced through indirect measurements, discrepancies with
literature values were found. The feasibility of using this device for mass
measurements of nuclides more neutron-deficient side, which have significant
impact on the $rp$-process pathway, is discussed.
-
A radiofrequency quadrupole ion trap system for use with a multi-reflection
time-of-flight mass spectrograph (MRTOF) for short-lived nuclei has been
developed. The trap system consists of two different parts, an asymmetric taper
trap and a flat trap. The ions are cooled to a sufficient small bunch for
precise mass measurement with MRTOF in only 2 ms cooling time in the flat trap,
then orthogonally ejected to the MRTOF for mass analysis. A trapping efficiency
of ~27% for 23Na+ and ~5.1% for 7Li+ has been achieved.
-
A multi-reflection time-of-flight mass spectrograph, competitive with Penning
trap mass spectrometers, has been built at RIKEN. We have performed a first
online mass measurement, using 8Li+ (T1/2 = 838 ms). A new analysis method has
been realized, with which, using only 12C+ references, the mass excess of 8Li
was accurately determined to be 20947.6(15)(34) keV (dm/m = 6.6 x 10-7). The
speed, precision and accuracy of this first online measurement exemplifies the
potential for using this new type of mass spectrograph for precision
measurements of short-lived nuclei.
-
For trans-uranium elements, stable atomic isobars do not exist. In order to
provide isobaric reference ions for the mass measurement of trans-uranium
elements, an electrospray ion source (ESI) was combined with an rf-carpet to
collect molecular ions efficiently. The rf-carpet allows for simplification of
the pumping system to transport ions from the ESI to a precision mass analyzer.
Molecular ions appropriate for isobaric references of trans-uranium elements
were extracted from the rf-carpet and analyzed by a multi-reflection
time-of-flight mass spectrograph (MRTOF-MS) with a resolving power of $\rm{R_m}
\gtrsim100,000$.
-
A new laser ion source configuration based on resonant photoionization in a
gas cell has been developed at RIBF RIKEN. This system is intended for the
future PArasitic RI-beam production by Laser Ion-Source (PALIS) project which
will be installed at RIKEN's fragment separator, BigRIPS. A novel
implementation of differential pumping, in combination with a sextupole ion
beam guide (SPIG), has been developed. A few small scroll pumps create a
pressure difference from 1000 hPa - 10^-3 Pa within a geometry drastically
miniaturized compared to conventional systems. This system can utilize a large
exit hole for fast evacuation times, minimizing the decay loss for short-lived
nuclei during extraction from a buffer gas cell, while sufficient gas cell
pressure is maintained for stopping high energy RI-beams. In spite of the
motion in a dense pressure gradient, the photo-ionized ions inside the gas cell
are ejected with an assisting force gas jet and successfully transported to a
high-vacuum region via SPIG followed by a quadrupole mass separator. Observed
behaviors agree with the results of gas flow and Monte Carlo simulations.