Modern TOF-PET scanner systems require high-speed computing resources for
efficient data processing, monitoring and image reconstruction. In this article
we present the data flow and software architecture for the novel TOF-PET
scanner developed by the J-PET collaboration. We discuss the data acquisition
system, reconstruction framework and image reconstruction software. Also, the
concept of computing outside hospitals in the remote centers such as \'Swierk
Computing Centre in Poland is presented.
-
The possibility to separate signals caused by 511 keV photons created in
annihilation of electron-positron pairs and the so-called prompt photons from
nuclei de- excitation is investigated. It could potentially be used to improve
the quality of reconstructed images in the J-PET scanner in 2+1 photon
tomography. Firstly, a research is conducted for several radioisotopes that
decay via \b{eta}+ decay followed by de-excitation of an excited nucleus.
Efficiency, purity and false positive rate are calculated for each isotope as a
function of energy deposited threshold, with a hypothesis that signals caused
by 511 keV photons deposit smaller values of energy than 1 z 13the selected
threshold, while prompt photons deposit larger energy than the threshold.
Analysis of the results accompanied with physical properties of radioisotopes
suggests using 44 Sc, which is the most promising candidate for medical
applications. With the use of GATE and J-POS simulation software, in-phantom
scattering was introduced and the best energy deposited threshold value was
estimated to be approximately 375 keV. It corresponds to almost 100% efficiency
for 511 keV signals, 75% purity for 511 keV photons, and approximately 70%
efficiency and purity for prompt photons.
-
The Jagiellonian Positron Emission Tomograph (J-PET) project carried out in
the Institute of Physics of the Jagiellonian University is focused on
construction and tests of the first prototype of PET scanner for medical
diagnostic which allows for the simultaneous 3D imaging of the whole human body
using organic scintillators. The J-PET prototype consists of 192 scintillator
strips forming three cylindrical layers which are optimized for the detection
of photons from the electron-positron annihilation with high time- and high
angular-resolutions. In this article we present time calibration and
synchronization of the whole J-PET detection system by irradiating each single
detection module with a 22Na source and a small detector providing common
reference time for synchronization of all the modules.
-
Positron Annihilation Lifetime Spectroscopy (PALS) has shown to be a powerful
tool to study the nanostructures of porous materials. Positron Emissions
Tomography (PET) are devices allowing imaging of metabolic processes e.g. in
human bodies. A newly developed device, the J-PET (Jagiellonian PET), will
allow PALS in addition to imaging, thus combining both analyses providing new
methods for physics and medicine. In this contribution we present a computer
program that is compatible with the J-PET software. We compare its performance
with the standard program LT 9.0 by using PALS data from hexane measurements at
different temperatures. Our program is based on an iterative procedure, and our
fits prove that it performs as good as LT 9.0.
-
In this article it is presented an FPGA based $M$ulti-$V$oltage $T$hreshold
(MVT) system which allows of sampling fast signals ($1-2$ ns rising and falling
edge) in both voltage and time domain. It is possible to achieve a precision of
time measurement of $20$ ps RMS and reconstruct charge of signals, using a
simple approach, with deviation from real value smaller than 10$\%$.
Utilization of the differential inputs of an FPGA chip as comparators together
with an implementation of a TDC inside an FPGA allowed us to achieve a compact
multi-channel system characterized by low power consumption and low production
costs. This paper describes realization and functioning of the system
comprising 192-channel TDC board and a four mezzanine cards which split
incoming signals and discriminate them. The boards have been used to validate a
newly developed Time-of-Flight Positron Emission Tomography system based on
plastic scintillators. The achieved full system time resolution of
$\sigma$(TOF) $\approx 68$ ps is by factor of two better with respect to the
current TOF-PET systems.
-
In this paper we estimate the time resolution of the J-PET scanner built from
plastic scintillators. We incorporate the method of signal processing using the
Tikhonov regularization framework and the Kernel Density Estimation method. We
obtain simple, closed-form analytical formulas for time resolutions. The
proposed method is validated using signals registered by means of the single
detection unit of the J-PET tomograph built out from 30 cm long plastic
scintillator strip. It is shown that the experimental and theoretical results,
obtained for the J-PET scanner equipped with vacuum tube photomultipliers, are
consistent.
-
We demonstrated the feasibility of measuring the axial coordinate of a gamma
quantum interaction point in a plastic scintillator bar via the detection of
scintillation photons escaping from the scintillator with an array of
wavelength-shifting (WLS) strips. Using a test set-up comprising a BC-420
scintillator bar and an~array of sixteen BC-482A WLS strips we achieved a
spatial resolution of~5\,mm~($\sigma$) for annihilation photons from a
$^{22}$Na isotope. The studied method can be used to improve the spatial
resolution of a plastic-scintillator-based PET scanner which is being developed
by the J-PET collaboration.
-
We present a study of the application of the Jagiellonian Positron Emission
Tomograph (J-PET) for the registration of gamma quanta from decays of
ortho-positronium (o-Ps). The J-PET is the first positron emission tomography
scanner based on organic scintillators in contrast to all current PET scanners
based on inorganic crystals. Monte Carlo simulations show that the J-PET as an
axially symmetric and high acceptance scanner can be used as a multi-purpose
detector well suited to pursue research including e.g. tests of discrete
symmetries in decays of ortho-positronium in addition to the medical imaging.
The gamma quanta originating from o-Ps decay interact in the plastic
scintillators predominantly via the Compton effect, making the direct
measurement of their energy impossible. Nevertheless, it is shown in this paper
that the J-PET scanner will enable studies of the o-Ps$\to3\gamma$ decays with
angular and energy resolution equal to $\sigma(\theta) \approx 0.4^{\circ}$ and
$\sigma(E) \approx 4.1$ keV, respectively. An order of magnitude shorter decay
time of signals from plastic scintillators with respect to the inorganic
crystals results not only in better timing properties crucial for the reduction
of physical and instrumental background, but also suppresses significantly the
pileups, thus enabling compensation of the lower efficiency of the plastic
scintillators by performing measurements with higher positron source
activities.
-
Recent tests of a single module of the Jagiellonian Positron Emission
Tomography system (J-PET) consisting of 30 cm long plastic scintillator strips
have proven its applicability for the detection of annihilation quanta (0.511
MeV) with a coincidence resolving time (CRT) of 0.266 ns. The achieved
resolution is almost by a factor of two better with respect to the current
TOF-PET detectors and it can still be improved since, as it is shown in this
article, the intrinsic limit of time resolution for the determination of time
of the interaction of 0.511 MeV gamma quanta in plastic scintillators is much
lower. As the major point of the article, a method allowing to record
timestamps of several photons, at two ends of the scintillator strip, by means
of matrix of silicon photomultipliers (SiPM) is introduced. As a result of
simulations, conducted with the number of SiPM varying from 4 to 42, it is
shown that the improvement of timing resolution saturates with the growing
number of photomultipliers, and that the 2 x 5 configuration at two ends
allowing to read twenty timestamps, constitutes an optimal solution. The
conducted simulations accounted for the emission time distribution, photon
transport and absorption inside the scintillator, as well as quantum efficiency
and transit time spread of photosensors, and were checked based on the
experimental results. Application of the 2 x 5 matrix of SiPM allows for
achieving the coincidence resolving time in positron emission tomography of
$\approx$ 0.170 ns for 15 cm axial field-of-view (AFOV) and $\approx$ 0.365 ns
for 100 cm AFOV. The results open perspectives for construction of a
cost-effective TOF-PET scanner with significantly better TOF resolution and
larger AFOV with respect to the current TOF-PET modalities.
-
Modern TOF-PET scanner systems require high-speed computing resources for
efficient data processing, monitoring and image reconstruction. In this article
we present the data flow and software architecture for the novel TOF-PET
scanner developed by the J-PET collaboration. We discuss the data acquisition
system, reconstruction framework and image reconstruction software. Also, the
concept of computing outside hospitals in the remote centers such as \'Swierk
Computing Centre in Poland is presented.
-
This work reports on a new reconstruction algorithm allowing to reconstruct
the decays of ortho-positronium atoms into three photons using the places and
times of photons recorded in the detector. The method is based on trilateration
and allows for a simultaneous reconstruction of both location and time of the
decay. Results of resolution tests of the new reconstruction in the J-PET
detector based on Monte Carlo simulations are presented, which yield a spatial
resolution at the level of 2 cm (FWHM) for X and Y and at the level of 1 cm
(FWHM) for Z available with the present resolution of J-PET after application
of a kinematic fit. Prospects of employment of this method for studying angular
correlations of photons in decays of polarized ortho-positronia for the needs
of tests of CP and CPT discrete symmetries are also discussed. The new
reconstruction method allows for discrimination of background from random
three-photon coincidences as well as for application of a novel method for
determination of the linear polarization of ortho-positronium atoms, which is
also introduced in this work.
-
In this paper, we present a complete Data Acquisition System (DAQ) together
with the readout mechanisms for the J-PET tomography scanner. In general
detector readout chain is constructed out of Front-End Electronics (FEE),
measurement devices like Time-to-Digital or Analog-to-Digital Converters (TDCs
or ADCs), data collectors and storage. We have developed a system capable for
maintaining continuous readout of digitized data without preliminary selection.
Such operation mode results in up to 8 Gbps data stream, therefore it is
required to introduce a dedicated module for online event building and feature
extraction. The Central Controller Module, equipped with Xilinx Zynq SoC and 16
optical transceivers serves as such true real time computing facility. Our
solution for the continuous data recording (trigger-less) is a novel approach
in such detector systems and assures that most of the information is preserved
on the storage for further, high-level processing. Signal discrimination
applies an unique method of using LVDS buffers located in the FPGA fabric.
-
A novel Positron Emission Tomography system, based on plastic scintillators,
is being developed by the J-PET collaboration. In this article we present the
simulation results of the scatter fraction, representing one of the parameters
crucial for background studies defined in the NEMA-NU-2-2012 norm. We elaborate
an event selection methods allowing to suppress events in which gamma quanta
were scattered in the phantom or underwent the multiple scattering in the
detector. The estimated scatter fraction for the single-layer J-PET scanner
varies from 37% to 53% depending on the applied energy threshold.
-
The Jagiellonian Positron Emission Tomograph (J-PET) was constructed as a
prototype of the cost-effective scanner for the simultaneous metabolic imaging
of the whole human body. Being optimized for the detection of photons from the
electron-positron annihilation with high time- and high angular-resolution, it
constitutes a multi-purpose detector providing new opportunities for studying
the decays of positronium atoms. Positronium is the lightest purely leptonic
object decaying into photons. As an atom bound by a central potential it is a
parity eigenstate, and as an atom built out of an electron and an anti-electron
it is an eigenstate of the charge conjugation operator. Therefore, the
positronium is a unique laboratory to study discrete symmetries whose precision
is limited in principle by the effects due to the weak interactions expected at
the level of (~10$^{-14}$) and photon-photon interactions expected at the level
of (~10$^{-9}$). The J-PET detector enables to perform tests of discrete
symmetries in the leptonic sector via the determination of the expectation
values of the discrete-symmetries-odd operators, which may be constructed from
the spin of ortho-positronium atom and the momenta and polarization vectors of
photons originating from its annihilation. In this article we present the
potential of the J-PET detector to test the C, CP, T and CPT symmetries in the
decays of positronium atoms.
-
Jagiellonian Positron Emission Tomograph (J-PET) is a multi-purpose detector
which will be used for search for discrete symmetries violations in the decays
of positronium atoms and for investigations with positronium atoms in
life-sciences and medical diagnostics. In this article we present three methods
for determination of the beam profile of collimated annihilation gamma quanta.
Precise monitoring of this profile is essential for time and energy calibration
of the J-PET detector and for the determination of the library of model signals
used in the hit-time and hit-position reconstruction. We have we have shown
that usage of two lead bricks with dimensions of 5x10x20 cm^3 enables to form a
beam of annihilation quanta with Gaussian profile characterized by 1 mm FWHM.
Determination of this characteristic is essential for designing and
construction the collimator system for the 24-module J-PET prototype.
Simulations of the beam profile for different collimator dimensions were
performed. This allowed us to choose optimal collimation system in terms of the
beam profile parameters, dimensions and weight of the collimator taking into
account the design of the 24 module J-PET detector.
-
In this paper we present prospects for using the J-PET detector to search for
discrete symmetries violations in a purely leptonic system of the positronium
atom. We discuss tests of CP and CPT symmetries by means of ortho-positronium
decays into three photons. No zero expectation values for chosen correlations
between ortho-positronium spin and momentum vectors of photons would imply the
existence of physics phenomena beyond the Standard Model. Previous measurements
resulted in violation amplitude parameters for CP and CPT symmetries consistent
with zero, with an uncertainty of about 10-3. The J-PET detector allows to
determine those values with better precision thanks to a unique time and
angular esolution combined with a high geometrical acceptance. Achieving the
aforementioned is possible due to application of polymer scintillators instead
of crystals as detectors of annihilation quanta.
-
Results of Positron Annihilation Lifetime Spectroscopy (PALS) and microscopic
studies on simple microorganisms: brewing yeasts are presented. Lifetime of
ortho - positronium (o-Ps) were found to change from 2.4 to 2.9 ns (longer
lived component) for lyophilised and aqueous yeasts, respectively. Also
hygroscopicity of yeasts in time was examined, allowing to check how water -
the main component of the cell - affects PALS parameters, thus lifetime of o-Ps
were found to change from 1.2 to 1.4 ns (shorter lived component) for the dried
yeasts. The time sufficient to hydrate the cells was found below 10 hours. In
the presence of liquid water an indication of reorganization of yeast in the
molecular scale was observed.
Microscopic images of the lyophilised, dried and wet yeasts with best
possible resolution were obtained using Inverted Microscopy (IM) and
Environmental Scanning Electron Microscopy (ESEM) methods. As a result visible
changes to the surface of the cell membrane were observed in ESEM images.
-
The J-PET detector being developed at Jagiellonian University, is a Positron
Emission Tomograph composed of the long strips of polymer scintillators. At the
same time it is a detector system which will be used for studies of the decays
of positronium atoms. The shape of photomultiplier signals depends on the
hit-time and hit-position of the gamma quantum. In order to take advantage of
this fact a dedicated sampling front-end electronics which enables to sample
signals in voltage domain with the time precision of about 20 ps and novel
reconstruction method based on the comparison of examined signal with the model
signals stored in the library has been developed. As a measure of the
similarity we use the Mahalanobis distance. The achievable position and
time-resolution depends on number and values of the threshold levels at which
the signal is sampled. A reconstruction method, as well as preliminary results
are presented and discussed.
-
The polystyrene dopped with 2,5-diphenyloxazole as a primary fluor and
2-(4-styrylphenyl)benzoxazole as a wavelength shifter, prepared as a plastic
scintillator was investigated using positronium probe in wide range of
temperatures from 123 to 423 K. Three structural transitions at 260 K, 283 K
and 370 K were found in the material. In the o-Ps intensity dependence on
temperature, the significant hysteresis is observed. Heated to 370 K, the
material exhibits the o-Ps intensity variations in time.
-
Nowadays, in Positron Emission Tomography (PET) systems, a Time of Flight
information is used to improve the image reconstruction process. In Time of
Flight PET (TOF-PET), fast detectors are able to measure the difference in the
arrival time of the two gamma rays, with the precision enabling to shorten
significantly a range along the line-of-response (LOR) where the annihilation
occurred. In the new concept, called J-PET scanner, gamma rays are detected in
plastic scintillators. In a single strip of J-PET system, time values are
obtained by probing signals in the amplitude domain. Owing to Compress Sensing
theory, information about the shape and amplitude of the signals is recovered.
In this paper we demonstrate that based on the acquired signals parameters, a
better signal normalization may be provided in order to improve the TOF
resolution. The procedure was tested using large sample of data registered by a
dedicated detection setup enabling sampling of signals with 50 ps intervals.
Experimental setup provided irradiation of a chosen position in the plastic
scintillator strip with annihilation gamma quanta.
-
In this article we present a novel method of hit time and hit position
reconstruction in long scintillator detectors. We take advantage of the fact
that for this kind of detectors amplitude and shape of registered signals
depends strongly on the position where particle hit the detector. The
reconstruction is based on determination of the degree of similarity between
measured and averaged signals stored in a library for a set of well-defined
positions along the scintillator. Preliminary results of validation of the
introduced method with experimental data obtained by means of the double strip
prototype of the J-PET detector are presented.
-
We present a fast GPU implementation of the image reconstruction routine, for
a novel two strip PET detector that relies solely on the time of flight
measurements.
-
J-PET analysis framework is a flexible, lightweight, ROOT-based software
package which provides the tools to develop reconstruction and calibration
procedures for PET tomography. In this article we present the implementation of
the full data-processing chain in the J-PET framework which is used for the
data analysis of the J-PET tomography scanner. The Framework incorporates
automated handling of PET setup parameters' database as well as high level
tools for building data reconstruction procedures. Each of these components is
briefly discussed.
-
For the first time a molecule of 2-(4-styrylphenyl)benzoxazole containing
benzoxazole and stilbene groups is applied as a scintillator dopant acting as a
wavelength shifter. In this article a light yield of the plastic scintillator,
prepared from styrene doped with 2 wt% of 2,5-diphenylbenzoxazole and 0.03 wt%
of 2-(4-styrylphenyl)benzoxazole, is determined to be as large as 60% $\pm$ 2%
of the anthracene light output. There is a potential to improve this value in
the future by the optimization of the additives concentrations.
-
The J-PET scanner, which allows for single bed imaging of the whole human
body, is currently under development at the Jagiellonian University. The dis-
cussed detector offers improvement of the Time of Flight (TOF) resolution due
to the use of fast plastic scintillators and dedicated electronics allowing for
sam- pling in the voltage domain of signals with durations of few nanoseconds.
In this paper we show that recovery of the whole signal, based on only a few
samples, is possible. In order to do that, we incorporate the training signals
into the Tikhonov regularization framework and we perform the Principal
Component Analysis decomposition, which is well known for its compaction
properties. The method yields a simple closed form analytical solution that
does not require iter- ative processing. Moreover, from the Bayes theory the
properties of regularized solution, especially its covariance matrix, may be
easily derived. This is the key to introduce and prove the formula for
calculations of the signal recovery error. In this paper we show that an
average recovery error is approximately inversely proportional to the number of
acquired samples.