Within the framework of xenon-based double beta decay experiments, we propose
the possibility to improve the background rejection of an electroluminescent
Time Projection Chamber (EL TPC) by reducing the diffusion of the drifting
electrons while keeping nearly intact the energy resolution of a pure xenon EL
TPC. Based on state-of-the-art microscopic simulations, a substantial addition
of helium, around 10 or 15~\%, may reduce drastically the transverse diffusion
down to 2.5~mm/$\sqrt{\mathrm{m}}$ from the 10.5~mm/$\sqrt{\mathrm{m}}$ of pure
xenon. The longitudinal diffusion remains around 4~mm/$\sqrt{\mathrm{m}}$.
Light production studies have been performed as well. They show that the
relative variation in energy resolution introduced by such a change does not
exceed a few percent, which leaves the energy resolution practically unchanged.
The technical caveats of using photomultipliers close to an helium atmosphere
are also discussed in detail.
-
High pressure gas time projection chambers (HPGTPCs) are made with a variety
of materials, many of which have not been well characterized in high pressure
noble gas environments. As HPGTPCs are scaled up in size toward ton-scale
detectors, assemblies become larger and more complex, creating a need for
detailed understanding of how structural supports and high voltage insulators
behave. This includes the identification of materials with predictable
mechanical properties and without surface charge accumulation that may lead to
field deformation or sparking. This paper explores the mechanical and
electrical effects of high pressure gas environments on insulating polymers
PTFE, HDPE, PEEK, POM and UHMW in Argon and Xenon, including studying
absorption, swelling and high voltage insulation strength.
-
Conceived to host 5 kg of xenon at a pressure of 15 bar in the fiducial
volume, the NEXT- White (NEW) apparatus is currently the largest high pressure
xenon gas TPC using electroluminescent amplification in the world. It is also a
1:2 scale model of the NEXT-100 detector scheduled to start searching for
$\beta\beta 0\nu$ decays in 136Xe in 2019. Both detectors measure the energy of
the event using a plane of photomultipliers located behind a transparent
cathode. They can also reconstruct the trajectories of charged tracks in the
dense gas of the TPC with the help of a plane of silicon photomultipliers
located behind the anode. A sophisticated gas system, common to both detectors,
allows the high gas purity needed to guarantee a long electron lifetime.
NEXT-White has been operating since October 2017 at the Canfranc Underground
Laboratory (LSC), in Spain. This paper describes the detector and associated
infrastructures.
-
Gaseous time projection chambers (TPC) are a very attractive detector
technology for particle tracking. Characterization of both drift velocity and
diffusion is of great importance to correctly assess their tracking
capabilities. NEXT-White is a High Pressure Xenon gas TPC with
electroluminescent amplification, a 1:2 scale model of the future NEXT-100
detector, which will be dedicated to neutrinoless double beta decay searches.
NEXT-White has been operating at Canfranc Underground Laboratory (LSC) since
December 2016. The drift parameters have been measured using $^{83m}$Kr for a
range of reduced drift fields at two different pressure regimes, namely 7.2 bar
and 9.1 bar. The results have been compared with Magboltz simulations.
Agreement at the 5% level or better has been found for drift velocity,
longitudinal diffusion and transverse diffusion.
-
The NEXT-White (NEW) detector is currently the largest radio-pure high
pressure gas xenon time projection chamber with electroluminescent readout in
the world. NEXT-White has been operating at Laboratorio Subterr\'aneo de
Canfranc (LSC) since October 2016. This paper describes the calibrations
performed with $^{83m}\mathrm{Kr}$ decays during a long run taken from March to
November 2017 (Run II). Krypton calibrations are used to correct for the finite
drift-electron lifetime as well as for the dependence of the measured energy on
the event position which is mainly caused by variations in solid angle
coverage. After producing calibration maps to correct for both effects we
measure an excellent energy resolution for 41.5 keV point-like deposits of
(4.55 $\pm$ 0.01) % FWHM in the full chamber and (3.88 $\pm$ 0.04) % FWHM in a
restricted fiducial volume. Using naive 1/$\sqrt{E}$ scaling, these values
translate into FWHM resolutions of (0.592 $\pm$ 0.001) % FWHM and (0.504 $\pm$
0.005) % at the $Q_{\beta\beta}$ energy of xenon double beta decay (2458 keV),
well within range of our target value of 1%.
-
The Neutrino Experiment with a Xenon Time-Projection Chamber (NEXT)
experiment intends to investigate the neutrinoless double beta decay of 136Xe,
and therefore requires a severe suppression of potential backgrounds. An
extensive material screening and selection process was undertaken to quantify
the radioactivity of the materials used in the experiment. Separate energy and
tracking readout planes using different sensors allow us to combine the
measurement of the topological signature of the event for background
discrimination with the energy resolution optimization. The design of radiopure
readout planes, in direct contact with the gas detector medium, was especially
challenging since the required components typically have activities too large
for experiments demanding ultra-low background conditions. After studying the
tracking plane, here the radiopurity control of the energy plane is presented,
mainly based on gamma-ray spectroscopy using ultra-low background germanium
detectors at the Laboratorio Subterr\'aneo de Canfranc (Spain). All the
available units of the selected model of photomultiplier have been screened
together with most of the components for the bases, enclosures and windows.
According to these results for the activity of the relevant radioisotopes, the
selected components of the energy plane would give a contribution to the
overall background level in the region of interest of at most 2.4 x 10-4 counts
keV-1 kg-1 y-1, satisfying the sensitivity requirements of the NEXT experiment.
-
The goal of the NEXT experiment is the observation of neutrinoless double
beta decay in $^{136}$Xe using a gaseous xenon TPC with electroluminescent
amplification and specialized photodetector arrays for calorimetry and
tracking. The NEXT Collaboration is exploring a number of reconstruction
algorithms to exploit the full potential of the detector. This paper describes
one of them: the Maximum Likelihood Expectation Maximization (ML-EM) method, a
generic iterative algorithm to find maximum-likelihood estimates of parameters
that has been applied to solve many different types of complex inverse
problems. In particular, we discuss a bi-dimensional version of the method in
which the photosensor signals integrated over time are used to reconstruct a
transverse projection of the event. First results show that, when applied to
detector simulation data, the algorithm achieves nearly optimal energy
resolution (better than 0.5% FWHM at the Q value of $^{136}$Xe) for events
distributed over the full active volume of the TPC.
-
We have measured the electroluminescence (EL) yield of Xe-CO2 mixtures, with
sub-percent CO2 concentrations. We demonstrate that the EL production is still
high in these mixtures, 70% and 35% relative to that produced in pure xenon,
for CO2 concentrations around 0.05% and 0.1%, respectively. The contribution of
the statistical fluctuations in EL production to the energy resolution
increases with increasing CO2 concentration and, for our gas proportional
scintillation counter, it is smaller than the contribution of the Fano factor
for concentrations below 0.1% CO2. Xe-CO2 mixtures are important alternatives
to pure xenon in TPCs based on EL signal amplification with applications in the
important field of rare event detection such as directional dark matter, double
electron capture and double beta decay detection. The addition of CO2 to pure
xenon at the level of 0.05-0.1% can reduce significantly the scale of electron
diffusion from 10 mm/sqrt(m) to 2.5 mm/sqrt(m), with high impact on the HPXe
TPC discrimination efficiency of the events through pattern recognition of the
topology of primary ionisation trails.