-
QUIJOTE (Q-U-I JOint TEnerife) is an experiment designed to achieve CMB
B-mode polarization detection and sensitive enough to detect a primordial
gravitational-wave component if the B-mode amplitude is larger than r = 0.05.
It consists in two telescopes and three instruments observing in the frequency
range 10-42 GHz installed at the Teide Observatory in the Canary Islands,
Spain. The observing strategy includes three raster scan deep integration
fields for cosmology, a nominal wide survey covering the Northen Sky and
specific raster scan deep integration observations in regions of specific
interest. The main goals of the project are presented and the first scientific
results obtained with the first instrument are reviewed.
-
QUIJOTE (Q-U-I JOint TEnerife) is a new polarimeter aimed to characterize the
polarization of the Cosmic Microwave Background and other Galactic and
extragalactic signals at medium and large angular scales in the frequency range
10-40 GHz. The multi-frequency (10-20~GHz) instrument, mounted on the first
QUIJOTE telescope, saw first light on November 2012 from the Teide Observatory
(2400~m a.s.l). During 2014 the second telescope has been installed at this
observatory. A second instrument at 30~GHz will be ready for commissioning at
this telescope during summer 2015, and a third additional instrument at 40~GHz
is now being developed. These instruments will have nominal sensitivities to
detect the B-mode polarization due to the primordial gravitational-wave
component if the tensor-to-scalar ratio is larger than r=0.05.
-
The QUIJOTE (Q-U-I JOint Tenerife) CMB Experiment is designed to observe the
polarization of the Cosmic Microwave Background and other Galactic and
extragalactic signals at medium and large angular scales in the frequency range
of 10-40 GHz. The first of the two QUIJOTE telescopes and the multi-frequency
(10-20 GHz) instrument have been in operation since November 2012. In 2014 a
second telescope and a new instrument at 30GHz will be ready for commissioning,
and an additional instrument at 40 GHz is in its final design stages. After
three years of effective observations, the data obtained by these telescopes
and instruments will have the required sensitivity to detect a primordial
gravitational-wave component if the tensor-to-scalar ratio is larger than r =
0.05. At the moment, we have completed half of the wide Galactic survey with
the multi-frequency instrument covering 18 000 square degrees of the Northern
hemisphere. When we finish this survey in early 2014, we shall have reached
approximately 14{\mu}K per one degree beam at 11, 13, 17 and 19 GHz, in both Q
and U.
-
The scientific performance of the Planck Low Frequency Instrument (LFI) after
one year of in-orbit operation is presented. We describe the main optical
parameters and discuss photometric calibration, white noise sensitivity, and
noise properties. A preliminary evaluation of the impact of the main systematic
effects is presented. For each of the performance parameters, we outline the
methods used to obtain them from the flight data and provide a comparison with
pre-launch ground assessments, which are essentially confirmed in flight.
-
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries
eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each
composed of a pair of pseudo-correlation receivers. We describe the on-ground
calibration campaign performed to qualify the flight model RCAs and to measure
their pre-launch performances. Each RCA was calibrated in a dedicated
flight-like cryogenic environment with the radiometer front-end cooled to 20K
and the back-end at 300K, and with an external input load cooled to 4K. A
matched load simulating a blackbody at different temperatures was placed in
front of the sky horn to derive basic radiometer properties such as noise
temperature, gain, and noise performance, e.g. 1/f noise. The spectral response
of each detector was measured as was their susceptibility to thermal variation.
All eleven LFI RCAs were calibrated. Instrumental parameters measured in these
tests, such as noise temperature, bandwidth, radiometer isolation, and
linearity, provide essential inputs to the Planck-LFI data analysis.
-
The 30 and 44 GHz Back End Modules (BEM) for the Planck Low Frequency
Instrument are broadband receivers (20% relative bandwidth) working at room
temperature. The signals coming from the Front End Module are amplified, band
pass filtered and finally converted to DC by a detector diode. Each receiver
has two identical branches following the differential scheme of the Planck
radiometers. The BEM design is based on MMIC Low Noise Amplifiers using GaAs
P-HEMT devices, microstrip filters and Schottky diode detectors. Their
manufacturing development has included elegant breadboard prototypes and
finally qualification and flight model units. Electrical, mechanical and
environmental tests were carried out for the characterization and verification
of the manufactured BEMs. A description of the 30 and 44 GHz Back End Modules
of Planck-LFI radiometers is given, with details of the tests done to determine
their electrical and environmental performances. The electrical performances of
the 30 and 44 GHz Back End Modules: frequency response, effective bandwidth,
equivalent noise temperature, 1/f noise and linearity are presented.
-
The Planck Low Frequency Instrument (LFI) radiometers have been tested
extensively during several dedicated campaigns. The present paper reports the
principal noise properties of the LFI radiometers.
-
We give the calibration and scientific performance parameters of the Planck
Low Frequency Instrument (LFI) measured during the ground cryogenic test
campaign. These parameters characterise the instrument response and constitute
our best pre-launch knowledge of the LFI scientific performance. The LFI shows
excellent $1/f$ stability and rejection of instrumental systematic effects;
measured noise performance shows that LFI is the most sensitive instrument of
its kind. The set of measured calibration parameters will be updated during
flight operations through the end of the mission.
-
In this paper we present the Low Frequency Instrument (LFI), designed and
developed as part of the Planck space mission, the ESA program dedicated to
precision imaging of the cosmic microwave background (CMB). Planck-LFI will
observe the full sky in intensity and polarisation in three frequency bands
centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be
covered by the HFI instrument. The LFI is an array of microwave radiometers
based on state-of-the-art Indium Phosphide cryogenic HEMT amplifiers
implemented in a differential system using blackbody loads as reference
signals. The front-end is cooled to 20K for optimal sensitivity and the
reference loads are cooled to 4K to minimise low frequency noise. We provide an
overview of the LFI, discuss the leading scientific requirements and describe
the design solutions adopted for the various hardware subsystems. The main
drivers of the radiometric, optical and thermal design are discussed, including
the stringent requirements on sensitivity, stability, and rejection of
systematic effects. Further details on the key instrument units and the results
of ground calibration are provided in a set of companion papers.
-
We present the current status of the QUIJOTE (Q-U-I JOint TEnerife) CMB
Experiment, a new instrument which will start operations early 2009 at Teide
Observatory, with the aim of characterizing the polarization of the CMB and
other processes of galactic and extragalactic emission in the frequency range
10-30 GHz and at large angular scales. QUIJOTE will be a valuable complement at
low frequencies for the PLANCK mission, and will have the required sensitivity
to detect a primordial gravitational-wave component if the tensor-to-scalar
ratio is larger than r=0.05.
-
The LFI (Low Frequency Instrument) on board the ESA Planck satellite is
constituted by an array of radiometric detectors actively cooled at 20 K in the
30-70 GHz frequency range in the focal plane of the Planck telescope. In this
paper we present an overview of the LFI instrument, with a particular focus on
the radiometer design. The adopted pseudo-correlation scheme uses a software
balancing technique (with a tunable parameter called gain modulation factor)
which is effective in reducing the radiometer susceptibility to amplifier
instabilities also in presence of small non-idealities in the radiometric chain
components, provided that the gain modulation factor is estimated with an
accuracy of the order of 0.2%. These results have been recently confirmed by
experimental laboratory measurements conducted on the LFI prototype radiometers
at 30, 70 and 100 GHz.