We present DARKNESS (the DARK-speckle Near-infrared Energy-resolving
Superconducting Spectrophotometer), the first of several planned integral field
spectrographs to use optical/near-infrared Microwave Kinetic Inductance
Detectors (MKIDs) for high-contrast imaging. The photon counting and
simultaneous low-resolution spectroscopy provided by MKIDs will enable
real-time speckle control techniques and post-processing speckle suppression at
framerates capable of resolving the atmospheric speckles that currently limit
high-contrast imaging from the ground. DARKNESS is now operational behind the
PALM-3000 extreme adaptive optics system and the Stellar Double Coronagraph at
Palomar Observatory. Here we describe the motivation, design, and
characterization of the instrument, early on-sky results, and future prospects.
-
For X-ray imaging spectroscopy, high spatial resolution over a large field of
view is often as important as high energy resolution, but current X-ray
detectors do not provide both in the same device. Thermal Kinetic Inductance
Detectors (TKIDs) are being developed as they offer a feasible way to combine
the energy resolution of transition edge sensors with pixel counts approaching
CCDs and thus promise significant improvements for many X-ray spectroscopy
applications. TKIDs are a variation of Microwave Kinetic Inductance Detectors
(MKIDs) and share their multiplexibility: working MKID arrays with 2024 pixels
have recently been demonstrated and much bigger arrays are under development.
In this work, we present our first working TKID prototypes which are able to
achieve an energy resolution of 75 eV at 5.9 keV, even though their general
design still has to be optimized. We further describe TKID fabrication,
characterization, multiplexing and working principle and demonstrate the
necessity of a data fitting algorithm in order to extract photon energies. With
further design optimizations we expect to be able to improve our TKID energy
resolution to less than 10 eV at 5.9 keV.
-
ARCONS, the Array Camera for Optical to Near-infrared Spectrophotometry, was
recently commissioned at the Coude focus of the 200-inch Hale Telescope at the
Palomar Observatory. At the heart of this unique instrument is a 1024-pixel
Microwave Kinetic Inductance Detector (MKID), exploiting the Kinetic Inductance
effect to measure the energy of the incoming photon to better than several
percent. The ground-breaking instrument is lens-coupled with a pixel scale of
0.23"/pixel, with each pixel recording the arrival time (<2 microsec) and
energy of a photon (~10%) in the optical to near-IR (0.4-1.1 microns) range.
The scientific objectives of the instrument include the rapid follow-up and
classification of the transient phenomena.
-
Microwave Kinetic Inductance Detectors, or MKIDs, have proven to be a
powerful cryogenic detector technology due to their sensitivity and the ease
with which they can be multiplexed into large arrays. A MKID is an energy
sensor based on a photon-variable superconducting inductance in a lithographed
microresonator, and is capable of functioning as a photon detector across the
electromagnetic spectrum as well as a particle detector. Here we describe the
first successful effort to create a photon-counting, energy-resolving
ultraviolet, optical, and near infrared MKID focal plane array. These new
Optical Lumped Element (OLE) MKID arrays have significant advantages over
semiconductor detectors like charge coupled devices (CCDs). They can count
individual photons with essentially no false counts and determine the energy
and arrival time of every photon with good quantum efficiency. Their physical
pixel size and maximum count rate is well matched with large telescopes. These
capabilities enable powerful new astrophysical instruments usable from the
ground and space. MKIDs could eventually supplant semiconductor detectors for
most astronomical instrumentation, and will be useful for other disciplines
such as quantum optics and biological imaging.
-
Titanium nitride (TiNx) films are ideal for use in superconducting
microresonator detectors because: a) the critical temperature varies with
composition (0 < Tc < 5 K); b) the normal-state resistivity is large, \rho_n ~
100 $\mu$Ohm cm, facilitating efficient photon absorption and providing a large
kinetic inductance and detector responsivity; and c) TiN films are very hard
and mechanically robust. Resonators using reactively sputtered TiN films show
remarkably low loss (Q_i > 10^7) and have noise properties similar to
resonators made using other materials, while the quasiparticle lifetimes are
reasonably long, 10-200 $\mu$s. TiN microresonators should therefore reach
sensitivities well below 10^-19 WHz^(-1/2).
-
We report on the development of ARCONS, the ARray Camera for Optical to
Near-IR Spectrophotometry. This photon counting integral field unit (IFU),
being built at UCSB and Caltech with detectors fabricated at JPL, will use a
unique, highly multiplexed low temperature detector technology known as
Microwave Kinetic Inductance Detectors (MKIDs). These detectors, which operate
at 100 mK, should provide photon counting with energy resolution of R =
E/{\delta}E > 20 and time resolution of a microsecond, with a quantum
efficiency of around 50%. We expect to field the instrument at the Palomar 200"
telescope in the first quarter of 2011 with an array containing 1024 pixels in
a 32x32 pixel form factor to yield a field of view of approximately 10x10
arcseconds. The bandwidth of the camera is limited by the rising sky count rate
at longer wavelengths, but we anticipate a bandwidth of 0.35 to 1.35 {\mu}m
will be achievable. A simple optical path and compact dewar utilizing a
cryogen-free adiabatic demagnetization refridgerator (ADR) allows the camera to
be deployed quickly at Naysmith or Coude foci at a variety of telescopes. A
highly expandable software defined radio (SDR) readout that can scale up to
much larger arrays has been developed.
-
The surface impedance of a superconductor changes when energy is absorbed and
Cooper pairs are broken to produce single electron (quasiparticle) excitations.
This change may be sensitively measured using a thin-film resonant circuit
called a microwave kinetic inductance detector (MKID). The practical
application of MKIDs for photon detection requires a method of efficiently
coupling the photon energy to the MKID. We present results on position
sensitive X-ray detectors made by using two aluminum MKIDs on either side of a
tantalum photon absorber strip. Diffusion constants, recombination times, and
energy resolution are reported. MKIDs can easily be scaled into large arrays.