Weakly Interacting Massive Particles (WIMPs) are a leading candidate for dark
matter and are expected to produce nuclear recoil (NR) events within liquid
xenon time-projection chambers. We present a measurement of the scintillation
timing characteristics of liquid xenon in the LUX dark matter detector and
develop a pulse shape discriminant to be used for particle identification. To
accurately measure the timing characteristics, we develop a template-fitting
method to reconstruct the detection times of photons. Analyzing calibration
data collected during the 2013-16 LUX WIMP search, we provide a new measurement
of the singlet-to-triplet scintillation ratio for electron recoils (ER) below
46~keV, and we make a first-ever measurement of the NR singlet-to-triplet ratio
at recoil energies below 74~keV. We exploit the difference of the photon time
spectra for NR and ER events by using a prompt fraction discrimination
parameter, which is optimized using calibration data to have the least number
of ER events that occur in a 50\% NR acceptance region. We then demonstrate how
this discriminant can be used in conjunction with the charge-to-light
discrimination to possibly improve the signal-to-noise ratio for nuclear
recoils.
-
The $(x, y)$ position reconstruction method used in the analysis of the
complete exposure of the Large Underground Xenon (LUX) experiment is presented.
The algorithm is based on a statistical test that makes use of an iterative
method to recover the photomultiplier tube (PMT) light response directly from
the calibration data. The light response functions make use of a two
dimensional functional form to account for the photons reflected on the inner
walls of the detector. To increase the resolution for small pulses, a photon
counting technique was employed to describe the response of the PMTs. The
reconstruction was assessed with calibration data including
${}^{\mathrm{83m}}$Kr (releasing a total energy of 41.5 keV) and ${}^{3}$H
($\beta^-$ with Q = 18.6 keV) decays, and a deuterium-deuterium (D-D) neutron
beam (2.45 MeV). In the horizontal plane, the reconstruction has achieved an
$(x, y)$ position uncertainty of $\sigma$= 0.82 cm for events of only 200
electroluminescence photons and $\sigma$ = 0.17 cm for 4,000
electroluminescence photons. Such signals are associated with electron recoils
of energies $\sim$0.25 keV and $\sim$10 keV, respectively. The reconstructed
position of the smallest events with a single electron emitted from the liquid
surface has a horizontal $(x, y)$ uncertainty of 2.13 cm.
-
The Large Underground Xenon experiment (LUX) searches for dark matter using a
dual-phase xenon detector. LUX uses a custom-developed trigger system for event
selection. In this paper, the trigger efficiency, which is defined as the
probability that an event of interest is selected for offline analysis, is
studied using raw data obtained from both electron recoil (ER) and nuclear
recoil (NR) calibrations. The measured efficiency exceeds 98\% at a pulse area
of 90 detected photons, which is well below the WIMP analysis threshold on the
S2 pulse area. The efficiency also exceeds 98\% at recoil energies of 1.3 keV
and above, for both ER and NR. The measured trigger efficiency varies between
99\% and 100\% over the fiducial volume of the detector.
-
LUX-ZEPLIN (LZ) is a next generation dark matter direct detection experiment
that will operate 4850 feet underground at the Sanford Underground Research
Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector
with an active mass of 7 tonnes, LZ will search primarily for low-energy
interactions with Weakly Interacting Massive Particles (WIMPs), which are
hypothesized to make up the dark matter in our galactic halo. In this paper,
the projected WIMP sensitivity of LZ is presented based on the latest
background estimates and simulations of the detector. For a 1000 live day run
using a 5.6 tonne fiducial mass, LZ is projected to exclude at 90% confidence
level spin-independent WIMP-nucleon cross sections above $1.6 \times 10^{-48}$
cm$^{2}$ for a 40 $\mathrm{GeV}/c^{2}$ mass WIMP. Additionally, a $5\sigma$
discovery potential is projected reaching cross sections below the existing and
projected exclusion limits of similar experiments that are currently operating.
For spin-dependent WIMP-neutron(-proton) scattering, a sensitivity of $2.7
\times 10^{-43}$ cm$^{2}$ ($8.1 \times 10^{-42}$ cm$^{2}$) for a 40
$\mathrm{GeV}/c^{2}$ mass WIMP is expected. With construction well underway, LZ
is on track for underground installation at SURF in 2019 and will start
collecting data in 2020.
-
The LUX-ZEPLIN (LZ) experiment will search for dark matter particle
interactions with a detector containing a total of 10 tonnes of liquid xenon
within a double-vessel cryostat. The large mass and proximity of the cryostat
to the active detector volume demand the use of material with extremely low
intrinsic radioactivity. We report on the radioassay campaign conducted to
identify suitable metals, the determination of factors limiting radiopure
production, and the selection of titanium for construction of the LZ cryostat
and other detector components. This titanium has been measured with activities
of $^{238}$U$_{e}$~$<$1.6~mBq/kg, $^{238}$U$_{l}$~$<$0.09~mBq/kg,
$^{232}$Th$_{e}$~$=0.28\pm 0.03$~mBq/kg, $^{232}$Th$_{l}$~$=0.25\pm
0.02$~mBq/kg, $^{40}$K~$<$0.54~mBq/kg, and $^{60}$Co~$<$0.02~mBq/kg (68\% CL).
Such low intrinsic activities, which are some of the lowest ever reported for
titanium, enable its use for future dark matter and other rare event searches.
Monte Carlo simulations have been performed to assess the expected background
contribution from the LZ cryostat with this radioactivity. In 1,000 days of
WIMP search exposure of a 5.6-tonne fiducial mass, the cryostat will contribute
only a mean background of $0.160\pm0.001$(stat)$\pm0.030$(sys) counts.
-
This work details the development of a three-dimensional (3D) electric field
model for the LUX detector. The detector took data during two periods of
searching for weakly interacting massive particle (WIMP) searches. After the
first period completed, a time-varying non-uniform negative charge developed in
the polytetrafluoroethylene (PTFE) panels that define the radial boundary of
the detector's active volume. This caused electric field variations in the
detector in time, depth and azimuth, generating an electrostatic
radially-inward force on electrons on their way upward to the liquid surface.
To map this behavior, 3D electric field maps of the detector's active volume
were built on a monthly basis. This was done by fitting a model built in COMSOL
Multiphysics to the uniformly distributed calibration data that were collected
on a regular basis. The modeled average PTFE charge density increased over the
course of the exposure from -3.6 to $-5.5~\mu$C/m$^2$. From our studies, we
deduce that the electric field magnitude varied while the mean value of the
field of $\sim200$~V/cm remained constant throughout the exposure. The varying
electric fields and their impact on event reconstruction and discrimination
were successfully modeled.
-
We report an absolute calibration of the ionization yields($\textit{Q$_y$})$
and fluctuations for electronic recoil events in liquid xenon at discrete
energies between 186 eV and 33.2 keV. The average electric field applied across
the liquid xenon target is 180 V/cm. The data are obtained using low energy
$^{127}$Xe electron capture decay events from the 95.0-day first run from LUX
(WS2013) in search of Weakly Interacting Massive Particles (WIMPs). The
sequence of gamma-ray and X-ray cascades associated with $^{127}$I
de-excitations produces clearly identified 2-vertex events in the LUX detector.
We observe the K- (binding energy, 33.2 keV), L- (5.2 keV), M- (1.1 keV), and
N- (186 eV) shell cascade events and verify that the relative ratio of observed
events for each shell agrees with calculations. The N-shell cascade analysis
includes single extracted electron (SE) events and represents the lowest-energy
electronic recoil $\textit{in situ}$ measurements that have been explored in
liquid xenon.
-
Inductively Coupled Plasma Mass Spectrometry (ICP-MS) allows for rapid,
high-sensitivity determination of trace impurities, notably the primordial
radioisotopes $^{238}$U and $^{232}$Th, in candidate materials for
low-background rare-event search experiments. We describe the setup and
characterisation of a dedicated low-background screening facility at University
College London where we operate an Agilent 7900 ICP-MS. The impact of reagent
and carrier gas purity is evaluated and we show that twice-distilled
ROMIL-SpA-grade nitric acid and zero-grade Ar gas delivers similar sensitivity
to ROMIL-UpA-grade acid and research grade gas. A straightforward procedure for
sample digestion and analysis of materials with U/Th concentrations down to 10
ppt g/g is presented. This includes the use of $^{233}$U and $^{230}$Th spikes
to correct for signal loss from a range of sources and verification of
$^{238}$U and $^{232}$Th recovery through digestion and analysis of a certified
reference material with a complex sample matrix. Finally, we demonstrate assays
and present results from two sample preparation and assay methods: a
high-sensitivity measurement of ultra-pure Ti using open digestion techniques,
and a closed vessel microwave digestion of a nickel-chromium-alloy using a
multi-acid mixture.
-
The LZ dark matter detector, like many other rare-event searches, will suffer
from backgrounds due to the radioactive decay of radon daughters. In order to
achieve its science goals, the concentration of radon within the xenon should
not exceed $2\mu$Bq/kg, or 20 mBq total within its 10 tonnes. The LZ
collaboration is in the midst of a program to screen all significant components
in contact with the xenon. The four institutions involved in this effort have
begun sharing two cross-calibration sources to ensure consistent measurement
results across multiple distinct devices. We present here five preliminary
screening results, some mitigation strategies that will reduce the amount of
radon produced by the most problematic components, and a summary of the current
estimate of radon emanation throughout the detector. This best estimate totals
$<17.3$ mBq, sufficiently low to meet the detector's science goals.
-
The Boulby Underground Germanium Suite (BUGS) comprises three low background,
high-purity germanium detectors operating in the Boulby Underground Laboratory,
located 1.1 km underground in the north-east of England, UK. BUGS utilises
three types of detector to facilitate a high-sensitivity, high-throughput
radioassay programme to support the development of rare-event search
experiments. A Broad Energy Germanium (BEGe) detector delivers sensitivity to
low-energy gamma-rays such as those emitted by 210Pb and 234Th. A Small Anode
Germanium (SAGe) well-type detector is employed for efficient screening of
small samples. Finally, a standard p-type coaxial detector provides fast
screening of standard samples. This paper presents the steps used to
characterise the performance of these detectors for a variety of sample
geometries, including the corrections applied to account for cascade summing
effects. For low-density materials, BUGS is able to radio-assay to specific
activities down to 3.6 mBq/kg for 234Th and 6.6 mBq/kg for 210Pb both of which
have uncovered some significant equilibrium breaks in the 238U chain. In denser
materials, where gamma-ray self-absorption increases, sensitivity is
demonstrated to specific activities of 0.9 mBq/kg for 226Ra, 1.1 mBq/kg for 228
Ra, 0.3 mBq/kg for 224Ra, and 8.6 mBq/kg for 40K with all upper limits at a 90%
confidence level. These meet the requirements of most screening campaigns
presently under way for rare-event search experiments, such as the LUX-ZEPLIN
(LZ) dark matter experiment. We also highlight the ability of the BEGe detector
to probe the X-ray fluorescence region which can be important to identify the
presence of radioisotopes associated with neutron production; this is of
particular relevance in experiments sensitive to nuclear recoils.
-
LUX was the first dark matter experiment to use a $^{83\textrm{m}}$Kr
calibration source. In this paper we describe the source preparation and
injection. We also present several $^{83\textrm{m}}$Kr calibration applications
in the context of the 2013 LUX exposure, including the measurement of temporal
and spatial variation in scintillation and charge signal amplitudes, and
several methods to understand the electric field within the time projection
chamber.
-
The first searches for axions and axion-like particles with the Large
Underground Xenon (LUX) experiment are presented. Under the assumption of an
axio-electric interaction in xenon, the coupling constant between axions and
electrons, gAe is tested, using data collected in 2013 with an exposure
totalling 95 live-days $\times$ 118 kg. A double-sided, profile likelihood
ratio statistic test excludes gAe larger than 3.5 $\times$ 10$^{-12}$ (90%
C.L.) for solar axions. Assuming the DFSZ theoretical description, the upper
limit in coupling corresponds to an upper limit on axion mass of 0.12
eV/c$^{2}$, while for the KSVZ description masses above 36.6 eV/c$^{2}$ are
excluded. For galactic axion-like particles, values of gAe larger than 4.2
$\times$ 10$^{-13}$ are excluded for particle masses in the range 1-16
keV/c$^{2}$. These are the most stringent constraints to date for these
interactions.
-
We present experimental constraints on the spin-dependent WIMP-nucleon
elastic cross sections from the total 129.5 kg-year exposure acquired by the
Large Underground Xenon experiment (LUX), operating at the Sanford Underground
Research Facility in Lead, South Dakota (USA). A profile likelihood ratio
analysis allows 90% CL upper limits to be set on the WIMP-neutron (WIMP-proton)
cross section of $\sigma_n$ = 1.6$\times 10^{-41}$ cm$^{2}$ ($\sigma_p$ =
5$\times 10^{-40}$ cm$^{2}$) at 35 GeV$c^{-2}$, almost a sixfold improvement
over the previous LUX spin-dependent results. The spin-dependent WIMP-neutron
limit is the most sensitive constraint to date.
-
In this Technical Design Report (TDR) we describe the LZ detector to be built
at the Sanford Underground Research Facility (SURF). The LZ dark matter
experiment is designed to achieve sensitivity to a WIMP-nucleon
spin-independent cross section of three times ten to the negative forty-eighth
square centimeters.
-
We report constraints on spin-independent weakly interacting massive particle
(WIMP)-nucleon scattering using a 3.35e4 kg-day exposure of the Large
Underground Xenon (LUX) experiment. A dual-phase xenon time projection chamber
with 250 kg of active mass is operated at the Sanford Underground Research
Facility under Lead, South Dakota (USA). With roughly fourfold improvement in
sensitivity for high WIMP masses relative to our previous results, this search
yields no evidence of WIMP nuclear recoils. At a WIMP mass of 50 GeV/c^2,
WIMP-nucleon spin-independent cross sections above 2.2e-46 cm^2 are excluded at
the 90% confidence level. When combined with the previously reported LUX
exposure, this exclusion strengthens to 1.1e-46 cm^2 at 50 GeV/c^2.
-
The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon
time projection chamber (TPC) operating at the Sanford Underground Research
Facility in Lead, South Dakota. A calibration of nuclear recoils in liquid
xenon was performed $\textit{in situ}$ in the LUX detector using a collimated
beam of mono-energetic 2.45 MeV neutrons produced by a deuterium-deuterium
(D-D) fusion source. The nuclear recoil energy from the first neutron scatter
in the TPC was reconstructed using the measured scattering angle defined by
double-scatter neutron events within the active xenon volume. We measured the
absolute charge ($Q_{y}$) and light ($L_{y}$) yields at an average electric
field of 180 V/cm for nuclear recoil energies spanning 0.7 to 74 keV and 1.1 to
74 keV, respectively. This calibration of the nuclear recoil signal yields will
permit the further refinement of liquid xenon nuclear recoil signal models and,
importantly for dark matter searches, clearly demonstrates measured ionization
and scintillation signals in this medium at recoil energies down to
$\mathcal{O}$(1 keV).
-
This work presents an analysis of monoenergetic electronic recoil peaks in
the dark-matter-search and calibration data from the first underground science
run of the Large Underground Xenon (LUX) detector. Liquid xenon charge and
light yields for electronic recoil energies between 5.2 and 661.7 keV are
measured, as well as the energy resolution for the LUX detector at those same
energies. Additionally, there is an interpretation of existing measurements and
descriptions of electron-ion recombination fluctuations in liquid xenon as
limiting cases of a more general liquid xenon re- combination fluctuation
model. Measurements of the standard deviation of these fluctuations at
monoenergetic electronic recoil peaks exhibit a linear dependence on the number
of ions for energy deposits up to 661.7 keV, consistent with previous LUX
measurements between 2-16 keV with $^3$H. We highlight similarities in liquid
xenon recombination for electronic and nuclear recoils with a comparison of
recombination fluctuations measured with low-energy calibration data.
-
We present the first experimental constraints on the spin-dependent
WIMP-nucleon elastic cross sections from LUX data acquired in 2013. LUX is a
dual-phase xenon time projection chamber operating at the Sanford Underground
Research Facility (Lead, South Dakota), which is designed to observe the recoil
signature of galactic WIMPs scattering from xenon nuclei. A profile likelihood
ratio analysis of $1.4~\times~10^{4}~\text{kg}\cdot~\text{days}$ of fiducial
exposure allows 90% CL upper limits to be set on the WIMP-neutron (WIMP-proton)
cross section of $\sigma_n~=~9.4~\times~10^{-41}~\text{cm}^2$
($\sigma_p~=~2.9~\times~10^{-39}~\text{cm}^2$) at 33 GeV/c$^2$. The
spin-dependent WIMP-neutron limit is the most sensitive constraint to date.
-
We present constraints on weakly interacting massive particles (WIMP)-nucleus
scattering from the 2013 data of the Large Underground Xenon dark matter
experiment, including $1.4\times10^{4}\;\mathrm{kg\; day}$ of search exposure.
This new analysis incorporates several advances: single-photon calibration at
the scintillation wavelength, improved event-reconstruction algorithms, a
revised background model including events originating on the detector walls in
an enlarged fiducial volume, and new calibrations from decays of an injected
tritium $\beta$ source and from kinematically constrained nuclear recoils down
to 1.1 keV. Sensitivity, especially to low-mass WIMPs, is enhanced compared to
our previous results which modeled the signal only above a 3 keV minimum
energy. Under standard dark matter halo assumptions and in the mass range above
4 $\mathrm{GeV}\,c^{-2}$, these new results give the most stringent direct
limits on the spin-independent WIMP-nucleon cross section. The 90% C.L. upper
limit has a minimum of 0.6 zb at 33 $\mathrm{GeV}\,c^{-2}$ WIMP mass.
-
The Large Underground Xenon (LUX) experiment operates at the Sanford
Underground Research Facility to detect nuclear recoils from the hypothetical
Weakly Interacting Massive Particles (WIMPs) on a liquid xenon target. Liquid
xenon typically contains trace amounts of the noble radioactive isotopes
$^{85}$Kr and $^{39}$Ar that are not removed by the {\em in situ} gas
purification system. The decays of these isotopes at concentrations typical of
research-grade xenon would be a dominant background for a WIMP search
exmperiment. To remove these impurities from the liquid xenon, a
chromatographic separation system based on adsorption on activated charcoal was
built. 400\,kg of xenon was processed, reducing the average concentration of
krypton from 130\,ppb to 3.5\,ppt as measured by a cold-trap assisted mass
spectroscopy system. A 50 kg batch spiked to 0.001 g/g of krypton was processed
twice and reduced to an upper limit of 0.2 ppt.
-
We present measurements of the electron-recoil (ER) response of the LUX dark
matter detector based upon 170,000 highly pure and spatially-uniform tritium
decays. We reconstruct the tritium energy spectrum using the combined energy
model and find good agreement with expectations. We report the average charge
and light yields of ER events in liquid xenon at 180 V/cm and 105 V/cm and
compare the results to the NEST model. We also measure the mean charge
recombination fraction and its fluctuations, and we investigate the location
and width of the LUX ER band. These results provide input to a re-analysis of
the LUX Run3 WIMP search.
-
LUX is a two-phase (liquid/gas) xenon time projection chamber designed to
detect nuclear recoils resulting from interactions with dark matter particles.
Signals from the detector are processed with an FPGA-based digital trigger
system that analyzes the incoming data in real-time, with just a few
microsecond latency. The system enables first pass selection of events of
interest based on their pulse shape characteristics and 3D localization of the
interactions. It has been shown to be >99% efficient in triggering on S2
signals induced by only few extracted liquid electrons. It is continuously and
reliably operating since its full underground deployment in early 2013. This
document is an overview of the systems capabilities, its inner workings, and
its performance.
-
This document presents the Conceptual Design Report (CDR) put forward by an
international neutrino community to pursue the Deep Underground Neutrino
Experiment at the Long-Baseline Neutrino Facility (LBNF/DUNE), a groundbreaking
science experiment for long-baseline neutrino oscillation studies and for
neutrino astrophysics and nucleon decay searches. The DUNE far detector will be
a very large modular liquid argon time-projection chamber (LArTPC) located deep
underground, coupled to the LBNF multi-megawatt wide-band neutrino beam. DUNE
will also have a high-resolution and high-precision near detector.
-
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of
March 2015 in this Conceptual Design Report. LZ is a second-generation
dark-matter detector with the potential for unprecedented sensitivity to weakly
interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds
of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most
sensitive experiment for WIMPs in this mass region by the end of the decade.
This report describes in detail the design of the LZ technical systems.
Expected backgrounds are quantified and the performance of the experiment is
presented. The LZ detector will be located at the Sanford Underground Research
Facility in South Dakota. The organization of the LZ Project and a summary of
the expected cost and current schedule are given.
-
The Large Underground Xenon (LUX) dark matter experiment aims to detect rare
low-energy interactions from Weakly Interacting Massive Particles (WIMPs). The
radiogenic backgrounds in the LUX detector have been measured and compared with
Monte Carlo simulation. Measurements of LUX high-energy data have provided
direct constraints on all background sources contributing to the background
model. The expected background rate from the background model for the 85.3 day
WIMP search run is
$(2.6\pm0.2_{\textrm{stat}}\pm0.4_{\textrm{sys}})\times10^{-3}$~events~keV$_{ee}^{-1}$~kg$^{-1}$~day$^{-1}$
in a 118~kg fiducial volume. The observed background rate is
$(3.6\pm0.4_{\textrm{stat}})\times10^{-3}$~events~keV$_{ee}^{-1}$~kg$^{-1}$~day$^{-1}$,
consistent with model projections. The expectation for the radiogenic
background in a subsequent one-year run is presented.