Hollow channel plasma wakefield acceleration is a proposed method to provide
high acceleration gradients for electrons and positrons alike: a key to future
lepton colliders. However, beams which are misaligned from the channel axis
induce strong transverse wakefields, deflecting beams and reducing the collider
luminosity. This undesirable consequence sets a tight constraint on the
alignment accuracy of the beam propagating through the channel. Direct
measurements of beam misalignment-induced transverse wakefields are therefore
essential for designing mitigation strategies. We present the first
quantitative measurements of transverse wakefields in a hollow plasma channel,
induced by an off-axis 20 GeV positron bunch, and measured with another 20 GeV
lower charge trailing positron probe bunch. The measurements are largely
consistent with theory.
-
Ionization injection in a plasma wakefield accelerator was investigated
experimentally using two lithium plasma sources of different lengths. The
ionization of the helium gas, used to confine the lithium, injects electrons in
the wake. After acceleration, these injected electrons were observed as a
distinct group from the drive beam on the energy spectrometer. They typically
have a charge of tens of pC, an energy spread of a few GeV, and a maximum
energy of up to 30 GeV. The emittance of this group of electrons can be many
times smaller than the initial emittance of the drive beam. The energy scaling
for the trapped charge from one plasma length to the other is consistent with
the blowout theory of the plasma wakefield.
-
Collimator wakefields in the Beam Delivery System (BDS) of future linear
colliders, such as the International Linear Collider (ILC) and the Compact
Linear Collider (CLIC), can be an important source of emittance growth and beam
jitter amplification, consequently degrading the luminosity. Therefore, a
better understanding of collimator wakefield effects is essential to optimise
the collimation systems of future linear colliders in order to minimise
wakefield effects. In the past, measurements of single-bunch collimator
wakefields have been carried out at SLAC with the aim of benchmarking theory,
numerical calculations and experiments. Those studies revealed some
discrepancies between the measurements and the theoretical models. New
experimental tests using available beam test facilities, such as the End
Station A Test Beam (ESTB) at SLAC, would help to improve our understanding on
collimator wakefields. ESTB will provide the perfect test bed to investigate
collimator wakefields for different bunch length conditions, relevant for both
ILC (300 micrometers nominal bunch length) and CLIC (44 micrometers nominal
bunch length) studies. Here we propose to perform new experimental tests of
collimator wakefield effects on electron/positron beams at SLAC ESTB.