• Login
    Sort by: Relevance Date Users's collections Twitter
    Group by: Day Week Month Year All time
Based on the idea and the provided source code of Andrej Karpathy (arxiv-sanity)
2:3 1:1 3:2
  • Machine learning applied to single-shot x-ray diagnostics in an XFEL (1610.03378)

    A. Sanchez-Gonzalez, P. Micaelli, C. Olivier, T. R. Barillot, M. Ilchen, A. A. Lutman, A. Marinelli, T. Maxwell, A. Achner, M. Agåker, N. Berrah, C. Bostedt, J. Buck, P. H. Bucksbaum, S. Carron Montero, B. Cooper, J. P. Cryan, M. Dong, R. Feifel, L. J. Frasinski, H. Fukuzawa, A. Galler, G. Hartmann, N. Hartmann, W. Helml, A. S. Johnson, A. Knie, A. O. Lindahl, J. Liu, K. Motomura, M. Mucke, C. O'Grady, J-E. Rubensson, E. R. Simpson, R. J. Squibb, C. Såthe, K. Ueda, M. Vacher, D. J. Walke, V. Zhaunerchyk, R. N. Coffee, J. P. Marangos
    Oct. 11, 2016 physics.data-an, physics.acc-ph, stat.ML
    ... ... ... ... ... ...
    X-ray free-electron lasers (XFELs) are the only sources currently able to produce bright few-fs pulses with tunable photon energies from 100 eV to more than 10 keV. Due to the stochastic SASE operating principles and other technical issues the output pulses are subject to large fluctuations, making it necessary to characterize the x-ray pulses on every shot for data sorting purposes. We present a technique that applies machine learning tools to predict x-ray pulse properties using simple electron beam and x-ray parameters as input. Using this technique at the Linac Coherent Light Source (LCLS), we report mean errors below 0.3 eV for the prediction of the photon energy at 530 eV and below 1.6 fs for the prediction of the delay between two x-ray pulses. We also demonstrate spectral shape prediction with a mean agreement of 97%. This approach could potentially be used at the next generation of high-repetition-rate XFELs to provide accurate knowledge of complex x-ray pulses at the full repetition rate.
  • Combined phase space characterization at the PEP-II IP using single-beam and luminous-region measurements (physics/0607087)

    A. Bevan, W. Kozanecki, B. Viaud, Y. Cai, A. Fisher, C. O'Grady, J. Thompson, M. Weaver
    July 10, 2006 physics.acc-ph
    We present a novel method to characterize the e+/- phase space at the IP of the SLAC B-factory, that combines single-beam measurements with a detailed mapping of luminous-region observables. Transverse spot sizes are determined in the two rings with synchrotron-light monitors and extrapolated to the IP using measured lattice functions. The specific luminosity, which is proportional to the inverse product of the overlap IP beam sizes, is continuously monitored using radiative-Bhabha events. The spatial variation of the luminosity and of the transverse-boost distribution of the colliding e+/-, are measured using e+ e- --> mu+ mu- events reconstructed in the BaBar detector. The combination of these measurements provide constraints on the emittances, horizontal and vertical spot sizes, angular divergences and beta functions of both beams at the IP during physics data-taking. Preliminary results of this combined spot-size analysis are confronted with independent measurements of IP beta-functions and overlap IP beam sizes at low beam current.
  • The BaBar Event Building and Level-3 Trigger Farm Upgrade (physics/0305136)

    S. Luitz, R. Bartoldus, S. Dasu, G. Dubois-Felsmann, B. Franek, J. Hamilton, R. Jacobsen, D. Kotturi, I. Narsky, C. O'Grady, A. Perazzo, R. Rodriguez, E. Rosenberg, A. Salnikov, M. Weaver, M. Wittgen, for the BaBar Computing Group
    May 30, 2003 physics.ins-det
    The BaBar experiment is the particle detector at the PEP-II B-factory facility at the Stanford Linear Accelerator Center. During the summer shutdown 2002 the BaBar Event Building and Level-3 trigger farm were upgraded from 60 Sun Ultra-5 machines and 100MBit/s Ethernet to 50 Dual-CPU 1.4GHz Pentium-III systems with Gigabit Ethernet. Combined with an upgrade to Gigabit Ethernet on the source side and a major feature extraction software speedup, this pushes the performance of the BaBar event builder and L3 filter to 5.5kHz at current background levels, almost three times the original design rate of 2kHz. For our specific application the new farm provides 8.5 times the CPU power of the old system.