• Login
    Sort by: Relevance Date Users's collections Twitter
    Group by: Day Week Month Year All time
Based on the idea and the provided source code of Andrej Karpathy (arxiv-sanity)
2:3 1:1 3:2
  • Microscopic simulation of xenon-based optical TPCs in the presence of molecular additives (1705.09481)

    C.D.R. Azevedo, D. Gonzalez-Diaz, S. F. Biagi, C.A.B. Oliveira, C.A.O. Henriques, J. Escada, F. Monrabal, J.J. Gómez-Cadenas, V. Álvarez, J. M. Benlloch-Rodríguez F.I.G.M. Borges, A. Botas, S. Cárcel, J. V. Carrión, S. Cebrián, C.A.N. Conde, J. Díaz, M. Diesburg, R. Esteve, R. Felkai, L.M.P. Fernandes, P. Ferrario, A.L. Ferreira, E.D.C. Freitas, A. Goldschmidt, R.M. Gutiérrez, J. Hauptman, A. I. Hernandez, J.A. Hernando Morata, V. Herrero, B.J.P. Jones, L. Labarga, A. Laing, P. Lebrun, I. Liubarsky, N. Lopez-March, M. Losada, J. Martín-Albo, A. Martínez, A. D. McDonald, C.M.B. Monteiro, F.J. Mora, L.M. Moutinho, J. Muñoz Vidal, M. Musti, M. Nebot-Guinot, P. Novella, D. Nygren, B. Palmeiro, A. Para, J. Pérez, M. Querol, J. Renner, L. Ripoll, J. Rodríguez, L. Rogers, F.P. Santos, J.M.F. dos Santos, L. Serra, D. Shuman, A. Simón, C. Sofka, M. Sorel, T. Stiegler, J.F. Toledo, J. Torrent, Z. Tsamalaidze, J.F.C.A. Veloso, R. Webb, J.T. White, N. Yahlali
    July 1, 2017 physics.ins-det
    ... ... ... ... ... ...
    We introduce a simulation framework for the transport of high and low energy electrons in xenon-based gaseous optical time projection chambers (OTPCs). The simulation relies on elementary cross sections (electron-atom and electron-molecule) and incorporates, in order to compute the gas scintillation, the reaction/quenching rates (atom-atom and atom-molecule) of the first 41 excited states of xenon and the relevant associated excimers, together with their radiative cascade. The results compare positively with observations made in pure xenon and its mixtures with CO$_2$ and CF$_4$ in a range of pressures from 0.1 to 10~bar. This work sheds some light on the elementary processes responsible for the primary and secondary xenon-scintillation mechanisms in the presence of additives, that are of interest to the OTPC technology.
  • Accurate gamma and MeV-electron track reconstruction with an ultra-low diffusion Xenon/TMA TPC at 10 atmospheres (1504.03678)

    Diego Gonzalez-Diaz, V. Alvarez, F.I.G. Borges, M. Camargo, S. Carcel, S. Cebrian, A. Cervera, C.A.N. Conde, T. Dafni, J. Diaz, R. Esteve, L.M.P. Fernandes, P. Ferrario, A.L. Ferreira, E.D.C. Freitas, V.M. Gehman, A. Goldschmidt, J.J. Gomez-Cadenas, R.M. Gutierrez, J. Hauptman, J.A. Hernando Morata, D.C. Herrera, I.G. Irastorza, L. Labarga, A. Laing, I. Liubarsky, N. Lopez-March, D. Lorca, M. Losada, G. Luzon, A. Mari, J. Martin-Albo, G. Martinez-Lema, A. Martinez, T. Miller, F. Monrabal, M. Monserrate, C.M.B. Monteiro, F.J. Mora, L.M. Moutinho, J. Munoz Vidal, M. Nebot-Guinot, D. Nygren, C.A.B. Oliveira, J. Perez, J.L. Perez Aparicio, M. Querol, J. Renner, L. Ripoll, J. Rodriguez, F.P. Santos, J.M.F. dos Santos, L. Serra, D. Shuman, A. Simon, C. Sofka, M. Sorel, J.F. Toledo, J. Torrent, Z. Tsamalaidze, J.F.C.A. Veloso, J.A. Villar, R.Webb, J.T. White, N. Yahlali, C. Azevedo, F. Aznar, D. Calvet, J. Castel, E. Ferrer-Ribas, J. A. Garcia, I. Giomataris, H. Gomez, F. J. Iguaz, A. Lagraba, A. Le Coguie, J.P. Mols,  O. Sahin, A. Rodriguez, E. Ruiz-Choliz, L. Segui, A. Tomas, R. Veenhof
    June 17, 2015 physics.ins-det
    ... ... ... ... ... ...
    We report the performance of a 10 atm Xenon/trimethylamine time projection chamber (TPC) for the detection of X-rays (30 keV) and gamma-rays (0.511-1.275 MeV) in conjunction with the accurate tracking of the associated electrons. When operated at such a high pressure and in 1%-admixtures, trimethylamine (TMA) endows Xenon with an extremely low electron diffusion (1.3 +-0.13 mm-sigma (longitudinal), 0.8 +-0.15 mm-sigma (transverse) along 1 m drift) besides forming a convenient Penning-Fluorescent mixture. The TPC, that houses 1.1 kg of gas in its active volume, operated continuously for 100 live-days in charge amplification mode. The readout was performed through the recently introduced microbulk Micromegas technology and the AFTER chip, providing a 3D voxelization of 8mm x 8mm x 1.2mm for approximately 10 cm/MeV-long electron tracks. This work was developed as part of the R&D program of the NEXT collaboration for future detector upgrades in the search of the 0bbnu decay in 136Xe, specifically those based on novel gas mixtures. Therefore we ultimately focus on the calorimetric and topological properties of the reconstructed MeV-electron tracks.
  • Radiopurity assessment of the tracking readout for the NEXT double beta decay experiment (1411.1433)

    S. Cebrián, J. Pérez, I. Bandac, L. Labarga, V. Álvarez, A.I. Barrado, A. Bettini, F.I.G.M. Borges, M. Camargo, S. Cárcel, A. Cervera, C.A.N. Conde, E. Conde, T. Dafni, J. Díaz, R. Esteve, L.M.P. Fernandes, M. Fernández, P. Ferrario, A.L. Ferreira, E.D.C. Freitas, V.M. Gehman, A. Goldschmidt, J.J. Gómez-Cadenas, D. González-Díaz, R.M. Gutiérrez, J. Hauptman, J.A. Hernando Morata, D.C. Herrera, I.G. Irastorza, A. Laing, I. Liubarsky, N. López-March, D. Lorca, M. Losada, G. Luzón, A. Marí, J. Martín-Albo, A. Martínez, G. Martínez-Lema, T. Miller, F. Monrabal, M. Monserrate, C.M.B. Monteiro, F.J. Mora, L.M. Moutinho, J. Muñoz Vidal, M. Nebot-Guinot, D. Nygren, C.A.B. Oliveira, A. Ortiz de Solórzano, J.L. Pérez Aparicio, M. Querol, J. Renner, L. Ripoll, J. Rodríguez, F.P. Santos, J.M.F. dos Santos, L. Serra, D. Shuman, A. Simón, C. Sofka, M. Sorel, J.F. Toledo, J. Torrent, Z. Tsamalaidze, J.F.C.A. Veloso, J.A. Villar, R.C. Webb, J.T. White, N. Yahlali
    June 15, 2015 hep-ex, nucl-ex, physics.ins-det
    ... ... ... ... ... ...
    The Neutrino Experiment with a Xenon Time-Projection Chamber (NEXT) is intended to investigate the neutrinoless double beta decay of 136Xe, which requires a severe suppression of potential backgrounds; therefore, an extensive screening and selection process is underway to control the radiopurity levels of the materials to be used in the experimental set-up of NEXT. The detector design combines the measurement of the topological signature of the event for background discrimination with the energy resolution optimization. Separate energy and tracking readout planes are based on different sensors: photomultiplier tubes for calorimetry and silicon multi-pixel photon counters for tracking. The design of a radiopure tracking plane, in direct contact with the gas detector medium, was specially challenging since the needed components like printed circuit boards, connectors, sensors or capacitors have typically, according to available information in databases and in the literature, activities too large for experiments requiring ultra-low background conditions. Here, the radiopurity assessment of tracking readout components based on gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterraneo de Canfranc (Spain) is described. According to the obtained results, radiopure enough printed circuit boards made of kapton and copper, silicon photomultipliers and other required components, fulfilling the requirement of an overall background level in the region of interest of at most 8 10-4 counts keV-1 kg-1 y-1, have been identified.
  • Radon and material radiopurity assessment for the NEXT double beta decay experiment (1505.07052)

    S. Cebrián, J. Pérez, I. Bandac, L. Labarga, V. Álvarez, A.I. Barrado, A. Bettini, F.I.G.M. Borges, M. Camargo, S. Cárcel, A. Cervera, C.A.N. Conde, E. Conde, T. Dafni, J. Díaz, R. Esteve, L.M.P. Fernandes, M. Fernández, P. Ferrario, E.D.C. Freitas, L.M.P. Fernandes, V.M. Gehman, A. Goldschmidt, J.J. Gómez-Cadenas, D. González-Díaz, R.M. Gutiérrez, J. Hauptman, J.A. Hernando Morata, D.C. Herrera, I.G. Irastorza, A. Laing, I. Liubarsky, N. López-March, D. Lorca, M. Losada, G. Luzón, A. Marí, J. Martín-Albo, A. Martínez, G. Martínez-Lema, T. Miller, F. Monrabal, M. Monserrate, C.M.B. Monteiro, F.J. Mora, L.M. Moutinho, J. Muñoz Vidal, M. Nebot-Guinot, D. Nygren, C.A.B. Oliveira, A. Ortiz de Solórzano, J.L. Pérez Aparicio, M. Querol, J. Renner, L. Ripoll, J. Rodríguez, F.P. Santos, J.M.F. dos Santos, L. Serra, D. Shuman, A. Simón, C. Sofka, M. Sorel, J.F. Toledo, J. Torrent, Z. Tsamalaidze, J.F.C.A. Veloso, J.A. Villar, R.C.Webb, J.T. White, N. Yahlali
    May 26, 2015 hep-ex, nucl-ex, physics.ins-det
    The Neutrino Experiment with a Xenon TPC (NEXT), intended to investigate the neutrinoless double beta decay using a high-pressure xenon gas TPC filled with Xe enriched in 136Xe at the Canfranc Underground Laboratory in Spain, requires ultra-low background conditions demanding an exhaustive control of material radiopurity and environmental radon levels. An extensive material screening process is underway for several years based mainly on gamma-ray spectroscopy using ultra-low background germanium detectors in Canfranc but also on mass spectrometry techniques like GDMS and ICPMS. Components from shielding, pressure vessel, electroluminescence and high voltage elements and energy and tracking readout planes have been analyzed, helping in the final design of the experiment and in the construction of the background model. The latest measurements carried out will be presented and the implication on NEXT of their results will be discussed. The commissioning of the NEW detector, as a first step towards NEXT, has started in Canfranc; in-situ measurements of airborne radon levels were taken there to optimize the system for radon mitigation and will be shown too.
  • An improved measurement of electron-ion recombination in high-pressure xenon gas (1412.3573)

    NEXT Collaboration: L. Serra, M. Sorel, V. Álvarez, F.I.G. Borges, M. Camargo, S. Cárcel, S. Cebrián, A. Cervera, C.A.N. Conde, T. Dafni, J. Díaz, R. Esteve, L.M.P. Fernandes, P. Ferrario, A.L. Ferreira, E.D.C. Freitas, V.M. Gehman, A. Goldschmidt, J.J. Gómez-Cadenas, D. González-Díaz, R.M. Gutiérrez, J. Hauptman, J.A. Hernando Morata, D.C. Herrera, I.G. Irastorza, L. Labarga, A. Laing, I. Liubarsky, N. Lopez-March, D. Lorca, M. Losada, G. Luzón, A. Marí, J. Martín-Albo, G. Martínez-Lema, A. Martínez, T. Miller, F. Monrabal, M. Monserrate, C.M.B. Monteiro, F.J. Mora, L.M. Moutinho, J. Muñoz Vidal, M. Nebot-Guinot, D. Nygren, C.A.B. Oliveira, J. Pérez, J.L. Pérez Aparicio, M. Querol, J. Renner, L. Ripoll, A. Rodríguez, J. Rodríguez, F.P. Santos, J.M.F. dos Santos, D. Shuman, A. Simón, C. Sofka, J.F. Toledo, J. Torrent, Z. Tsamalaidze, J.F.C.A. Veloso, J.A. Villar, R. Webb, J.T. White, N. Yahlali
    Feb. 3, 2015 hep-ex, physics.ins-det
    ... ... ... ... ... ...
    We report on results obtained with the NEXT-DEMO prototype of the NEXT-100 high-pressure xenon gas time projection chamber (TPC), exposed to an alpha decay calibration source. Compared to our previous measurements with alpha particles, an upgraded detector and improved analysis techniques have been used. We measure event-by-event correlated fluctuations between ionization and scintillation due to electron-ion recombination in the gas, with correlation coeffcients between -0.80 and -0.56 depending on the drift field conditions. By combining the two signals, we obtain a 2.8 % FWHM energy resolution for 5.49 MeV alpha particles and a measurement of the optical gain of the electroluminescent TPC. The improved energy resolution also allows us to measure the specific activity of the radon in the gas due to natural impurities. Finally, we measure the average ratio of excited to ionized atoms produced in the xenon gas by alpha particles to be $0.561\pm 0.045$, translating into an average energy to produce a primary scintillation photon of $W_{\rm ex}=(39.2\pm 3.2)$ eV.
  • Results of the material screening program of the NEXT experiment (1411.1222)

    T. Dafni, V. Alvarez, I. Bandac, A. Bettini, F.I.G.M. Borges, M. Camargo, S. Carcel, S. Cebrian, A. Cervera, C.A.N. Conde, J. Diaz, R. Esteve, L.M.P. Fernandes, M. Fernandez, P. Ferrario, A.L. Ferreira, E.D.C. Freitas, V.M. Gehman, A. Goldschmidt, H. Gomez, J.J. Gomez-Cadenas, D. Gonzalez-Diaz, R.M. Gutierrez, J. Hauptman, J.A. Hernando Morata, D.C. Herrera, F.J. Iguaz, I.G. Irastorza, L. Labarga, A. Laing, I. Liubarsky, D. Lorca, M. Losada, G. Luzon, A. Mari, J. Martin-Albo, A. Martinez, G. Martinez-Lema, T. Miller, F. Monrabal, M. Monserrate, C.M.B. Monteiro, F.J. Mora, L.M. Moutinho, J. Munoz Vidal, M. Nebot-Guinot, D. Nygren, C.A.B. Oliveira, J. Perez, J.L. Perez Aparicio, J. Renner, L. Ripoll, A. Rodriguez, J. Rodriguez, F.P. Santos, J.M.F. dos Santos, L. Segui, L. Serra, D. Shuman, A. Simon, C. Sofka, M. Sorel, J.F. Toledo, J. Torrent, Z. Tsamalaidze, J.F.C.A. Veloso, J.A. Villar, R.C. Webb, J.T. White, N. Yahlali
    Nov. 5, 2014 hep-ex, nucl-ex, physics.ins-det
    ... ... ... ... ... ...
    The 'Neutrino Experiment with a Xenon TPC (NEXT)', intended to investigate neutrinoless double beta decay, requires extremely low background levels. An extensive material screening and selection process to assess the radioactivity of components is underway combining several techniques, including germanium gamma-ray spectrometry performed at the Canfranc Underground Laboratory; recent results of this material screening program are presented here.
  • Characterisation of NEXT-DEMO using xenon K$_{\alpha}$ X-rays (1407.3966)

    NEXT Collaboration: D. Lorca, J. Martín-Albo, A. Laing, P. Ferrario, J.J. Gómez-Cadenas, V. Álvarez, F.I.G. Borges, M. Camargo, S. Cárcel, S. Cebrián, A. Cervera, C.A.N. Conde, T. Dafni, J. Díaz, R. Esteve, L.M.P. Fernandes, A.L. Ferreira, E.D.C. Freitas, V.M. Gehman, A. Goldschmidt, H. Gómez, D. González-Díaz, R.M. Gutiérrez, J. Hauptman, J.A. Hernando Morata, D.C. Herrera, I.G. Irastorza, L. Labarga, I. Liubarsky, M. Losada, G. Luzón, A. Marí, G. Martínez-Lema, A. Martínez, T. Miller, F. Monrabal, M. Monserrate, C.M.B. Monteiro, F.J. Mora, L.M. Moutinho, J. Muñoz Vidal, M. Nebot-Guinot, D. Nygren, C.A.B. Oliveira, J. Pérez, J.L. Pérez Aparicio, J. Renner, L. Ripoll, A. Rodríguez, J. Rodríguez, F.P. Santos, J.M.F. dos Santos, L. Seguí, L. Serra, D. Shuman, A. Simón, C. Sofka, M. Sorel, J.F. Toledo, J. Torrent, Z. Tsamalaidze, J.F.C.A. Veloso, R. Webb, J.T. White, N. Yahlali
    Nov. 5, 2014 hep-ex, physics.ins-det
    ... ... ... ... ... ...
    The NEXT experiment aims to observe the neutrinoless double beta decay of $^{136}$Xe in a high pressure gas TPC using electroluminescence (EL) to amplify the signal from ionization. Understanding the response of the detector is imperative in achieving a consistent and well understood energy measurement. The abundance of xenon k-shell x-ray emission during data taking has been identified as a multitool for the characterisation of the fundamental parameters of the gas as well as the equalisation of the response of the detector. The NEXT-DEMO prototype is a ~1.5 kg volume TPC filled with natural xenon. It employs an array of 19 PMTs as an energy plane and of 256 SiPMs as a tracking plane with the TPC light tube and SiPM surfaces being coated with tetraphenyl butadiene (TPB) which acts as a wavelength shifter for the VUV scintillation light produced by xenon. This paper presents the measurement of the properties of the drift of electrons in the TPC, the effects of the EL production region, and the extraction of position dependent correction constants using K$_{\alpha}$ X-ray deposits. These constants were used to equalise the response of the detector to deposits left by gammas from $^{22}$Na.
  • Description and commissioning of NEXT-MM prototype: first results from operation in a Xenon-Trimethylamine gas mixture (1311.3242)

    NEXT Collaboration: V. Álvarez, F. Aznar, F.I.G.M. Borges, D. Calvet, S. Cárcel, J. Castel, S. Cebrián, A. Cervera, C.A.N. Conde, T. Dafni, T.H.V.T. Dias, J. Díaz, F. Druillole, M. Egorov, R. Esteve, P. Evtoukhovitch, L.M.P. Fernandes, P. Ferrario, A.L. Ferreira, E. Ferrer-Ribas, E.D.C. Freitas, V.M. Gehman, A. Gil, I. Giomataris, A. Goldschmidt, H. Gómez, J.J. Gómez-Cadenas, D. González-Díaz, R.M. Gutiérrez, J. Hauptman, J.A. Hernando Morata, D.C. Herrera, F.J. Iguaz, I.G. Irastorza, M.A. Jinete, L. Labarga, A. Laing, A. Le Coguie, I. Liubarsky, J.A.M. Lopes, D. Lorca, M. Losada, G. Luzón, A. Marí, J. Martín-Albo, A. Martínez, G. Martínez-Lema, T. Miller, A. Moiseenko, J.P. Mols, F. Monrabal, C.M.B. Monteiro, F.J. Mora, L.M. Moutinho, J. Muñoz Vidal, H. Natal da Luz, G. Navarro, M. Nebot-Guinot, D. Nygren, C.A.B. Oliveira, R. Palma, J. Pérez, J.L. Pérez Aparicio, J. Renner, L. Ripoll, A. Rodríguez, J. Rodríguez, P. Santos, J.M.F. dos Santos, L. Segui, L. Serra, D. Shuman, A. Simón, C. Sofka, M. Sorel, J.F. Toledo, A. Tomás, J. Torrent, Z. Tsamalaidze, J.F.C.A. Veloso, J.A. Villar, R.C. Webb, J.T. White, N. Yahlali
    Nov. 27, 2013 physics.ins-det
    A technical description of NEXT-MM and its commissioning and first performance is reported. Having an active volume of ~35 cm drift $\times$ 28 cm diameter, it constitutes the largest Micromegas-read TPC operated in Xenon ever constructed, made by a sectorial arrangement of the 4 largest single wafers manufactured with the Microbulk technique to date. It is equipped with a suitably pixelized readout and with a sufficiently large sensitive volume (~23 l) so as to contain long (~20 cm) electron tracks. First results obtained at 1 bar for Xenon and trimethylamine (Xe-(2 %)TMA) mixture are presented. The TPC can accurately reconstruct extended background tracks. An encouraging full-width half-maximum of 11.6 % was obtained for ~29 keV gammas without resorting to any data post-processing.
  • Characterization of a medium size Xe/TMA TPC instrumented with microbulk Micromegas, using low-energy $\gamma$-rays (1311.3535)

    The NEXT collaboration: V. Alvarez, F.I.G.M. Borges, S. Carcel, J. Castel, S. Cebrian, A. Cervera, C.A.N. Conde, T. Dafni, T.H.V.T. Dias, J. Diaz, M. Egorov, R. Esteve, P. Evtoukhovitch, L.M.P. Fernandes, P. Ferrario, A.L. Ferreira, E.D.C. Freitas, V.M. Gehman, A. Gil, A. Goldschmidt, H. Gomez, J.J. Gomez-Cadenas, D. Gonzalez-Diaz, R.M. Gutierrez, J. Hauptman, J.A. Hernando Morata, D.C. Herrera, F.J. Iguaz, I.G. Irastorza, M.A. Jinete, L. Labarga, A. Laing, I. Liubarsky, J.A.M. Lopes, D. Lorca, M. Losada, G. Luzon, A. Mari, J. Martin-Albo, A. Martinez, G. Martinez-Lema, T. Miller, A. Moiseenko, F. Monrabal, C.M.B. Monteiro, F.J. Mora, L.M. Moutinho, J. Munoz Vidal, H. Natal da Luz, G. Navarro, M. Nebot-Guinot, D. Nygren, C.A.B. Oliveira, R. Palma, J. Perez, J.L. Perez Aparicio, J. Renner, L. Ripoll, A. Rodriguez, J. Rodriguez, F.P. Santos, J.M.F. dos Santos, L. Segui, L. Serra, D. Shuman, A. Simon, C. Sofka, M. Sorel, J.F. Toledo, A. Tomas, J. Torrent, Z. Tsamalaidze, D. Vazquez, J.F.C.A. Veloso, J.A. Villar, R.C. Webb, J.T. White, N. Yahlali, F. Aznar, D. Calvet, F. Druillole, E. Ferrer-Ribas, J. A. Garcia, I. Giomataris, J. Gracia, A. Le Coguie, J.P. Mols, P. Pons, E. Ruiz
    Nov. 18, 2013 physics.ins-det
    NEXT-MM is a general-purpose high pressure (10 bar, $\sim25$ l active volume) Xenon-based TPC, read out in charge mode with an 8 cm $\times$8 cm-segmented 700 cm$^2$ plane (1152 ch) of the latest microbulk-Micromegas technology. It has been recently commissioned at University of Zaragoza as part of the R&D of the NEXT $0\nu\beta\beta$ experiment, although the experiment's first stage is currently being built based on a SiPM/PMT-readout concept relying on electroluminescence. Around 2 million events were collected during the last months, stemming from the low energy $\gamma$-rays emitted by a $^{241}$Am source when interacting with the Xenon gas ($\epsilon$ = 26, 30, 59.5 keV). The localized nature of such events above atmospheric pressure, the long drift times, as well as the possibility to determine their production time from the associated $\alpha$ particle in coincidence, allow the extraction of primordial properties of the TPC filling gas, namely the drift velocity, diffusion and attachment coefficients. In this work we focus on the little explored combination of Xe and trimethylamine (TMA) for which, in particular, such properties are largely unknown. This gas mixture offers potential advantages over pure Xenon when aimed at Rare Event Searches, mainly due to its Penning characteristics, wave-length shifting properties and reduced diffusion, and it is being actively investigated by our collaboration. The chamber is currently operated at 2.7 bar, as an intermediate step towards the envisaged 10 bar. We report here its performance as well as a first implementation of the calibration procedures that have allowed the extension of the previously reported energy resolution to the whole readout plane (10.6%FWHM@30keV).
  • Present status and future perspectives of the NEXT experiment (1307.3914)

    The NEXT Collaboration: J.J. Gómez-Cadenas, V. Álvarez, F.I.G.M. Borges, S. Cárcel, J. Castel, S. Cebrián, A. Cervera, C.A.N. Conde, T. Dafni, T.H.V.T. Dias, J. Díaz, M. Egorov, R. Esteve, P. Evtoukhovitch, L.M.P. Fernandes, P. Ferrario, A.L. Ferreira, E.D.C. Freitas, V.M. Gehman, A. Gil, A. Goldschmidt, H. Gómez, D. González-Díaz, R.M. Gutiérrez, J. Hauptman, J.A. Hernando Morata, D.C. Herrera, F.J. Iguaz, I.G. Irastorza, M.A. Jinete, L. Labarga, A. Laing, I. Liubarsky, J.A.M. Lopes, D. Lorca, M. Losada, G. Luzón, A. Marí, J. Martín-Albo, A. Martínez, T. Miller, A. Moiseenko, F. Monrabal, C.M.B. Monteiro, F.J. Mora, L.M. Moutinho, J. Muñoz Vidal, H. Natal da Luz, G. Navarro, M. Nebot-Guinot, D. Nygren, C.A.B. Oliveira, R. Palma, J. Pérez, J.L. Pérez Aparicio, J. Renner, L. Ripoll, A. Rodríguez, J. Rodríguez, F.P. Santos, J.M.F. dos Santos, L. Segui, L. Serra, D. Shuman, A. Simón, C. Sofka, M. Sorel, J.F. Toledo, A. Tomás, J. Torrent, Z. Tsamalaidze, J.F.C.A. Veloso, J.A. Villar, R.C. Webb, J. White, N. Yahlali
    July 29, 2013 physics.ins-det
    ... ... ... ... ... ...
    NEXT is an experiment dedicated to neutrinoless double beta decay searches in xenon. The detector is a TPC, holding 100 kg of high-pressure xenon enriched in the $^{136}$Xe isotope. It is under construction in the Laboratorio Subterr\'aneo de Canfranc in Spain, and it will begin operations in 2015. The NEXT detector concept provides an energy resolution better than 1% FWHM and a topological signal that can be used to reduce the background. Furthermore, the NEXT technology can be extrapolated to a 1-ton scale experiment.
  • Operation and first results of the NEXT-DEMO prototype using a silicon photomultiplier tracking array (1306.0471)

    The NEXT Collaboration: V. Álvarez, F.I.G. Borges, S. Cárcel, J. Castel, S. Cebrián, A. Cervera, C.A.N. Conde, T. Dafni, T.H.V.T. Dias, J. Díaz, M. Egorov, R. Esteve, P. Evtoukhovitch, L.M.P. Fernandes, P. Ferrario, A.L. Ferreira, E.D.C. Freitas, V.M. Gehman, A. Gil, A. Goldschmidt, H. Gómez, J.J. Gómez-Cadenas, D. González-Díaz, R.M. Gutiérrez, J. Hauptman, J.A. Hernando Morata, D.C. Herrera, F.J. Iguaz, I.G. Irastorza, M.A. Jinete, L. Labarga, A. Laing, I. Liubarsky, J.A.M. Lopes, D. Lorca, M. Losada, G. Luzón, A. Marí, J. Martín-Albo, A. Martínez, G. Martínez, T. Miller, A. Moiseenko, F. Monrabal, C.M.B. Monteiro, F.J. Mora, L.M. Moutinho, J. Muñoz Vidal, H. Natal da Luz, G. Navarro, M. Nebot-Guinot, D. Nygren, C.A.B. Oliveira, R. Palma, J. Pérez, J.L. Pérez Aparicio, J. Renner, L. Ripoll, A. Rodríguez, J. Rodríguez, F.P. Santos, J.M.F. dos Santos, L. Seguí, L. Serra, D. Shuman, A. Simón, C. Sofka, M. Sorel, J.F. Toledo, A. Tomás, J. Torrent, Z. Tsamalaidze, J.F.C.A. Veloso, J.A. Villar, R. Webb, J.T. White, N. Yahlali
    June 7, 2013 physics.ins-det
    ... ... ... ... ... ...
    NEXT-DEMO is a high-pressure xenon gas TPC which acts as a technological test-bed and demonstrator for the NEXT-100 neutrinoless double beta decay experiment. In its current configuration the apparatus fully implements the NEXT-100 design concept. This is an asymmetric TPC, with an energy plane made of photomultipliers and a tracking plane made of silicon photomultipliers (SiPM) coated with TPB. The detector in this new configuration has been used to reconstruct the characteristic signature of electrons in dense gas. Demonstrating the ability to identify the MIP and "blob" regions. Moreover, the SiPM tracking plane allows for the definition of a large fiducial region in which an excellent energy resolution of 1.82% FWHM at 511 keV has been measured (a value which extrapolates to 0.83% at the xenon Qbetabeta).
  • Design and characterization of the SiPM tracking system of NEXT-DEMO, a demonstrator prototype of the NEXT-100 experiment (1206.6199)

    NEXT Collaboration: V. Álvarez, M.Ball, F.I.G.M. Borges, S. Cárcel, J.M. Carmona, J. Castel, J.M. Catalá, S. Cebrián, A. Cervera, D. Chan, C.A.N. Conde, T. Dafni, T.H.V.T. Dias, J. Díaz, M. Egorov, R. Esteve, P. Evtoukhovitch, L.M.P. Fernandes, P. Ferrario, A.L. Ferreira, E. Ferrer-Ribas, E.D.C. Freitas, A.N.C. Garcia, V.M. Gehman, A. Gil, I. Giomataris, A. Goldschmidt, H. Gómez, J.J. Gómez-Cadenas, K. González, D. González-Díaz, R.M. Gutiérrez, J. Hauptman, J.A. Hernando Morata, D.C. Herrera, V. Herrero, F.J. Iguaz, I.G. Irastorza, V. Kalinnikov, D. Kiang, L. Labarga, I. Liubarsky, J.A.M. Lopes, D. Lorca, M. Losada, G. Luzón, A. Marí, J. Martín-Albo, A. Martínez, T. Miller, A. Moiseenko, F. Monrabal, C.M.B. Monteiro, J.M. Monzó, F.J. Mora, L.M. Moutinho, J. Muñoz Vidal, H. Natal da Luz, G. Navarro, M. Nebot, D. Nygren, C.A.B. Oliveira, R. Palma, J. Pérez, J.L. Pérez Aparicio, J. Renner, L. Ripoll, A. Rodríguez, J. Rodríguez, F.P. Santos, J.M.F. dos Santos, L. Segui, L. Serra, D. Shuman, C. Sofka, M. Sorel, J.F. Toledo, A. Tomás, J. Torrent, Z. Tsamalaidze, D. Vázquez, E. Velicheva, J.F.C.A. Veloso, J.A. Villar, R.C. Webb, T. Weber, J. White, N. Yahlali
    Feb. 22, 2013 hep-ex, physics.ins-det
    ... ... ... ... ... ...
    NEXT-100 experiment aims at searching the neutrinoless double-beta decay of the Xe-136 isotope using a TPC filled with a 100 kg of high-pressure gaseous xenon, with 90% isotopic enrichment. The experiment will take place at the Laboratorio Subterr\'aneo de Canfranc (LSC), Spain. NEXT-100 uses electroluminescence (EL) technology for energy measurement with a resolution better than 1% FWHM. The gaseous xenon in the TPC additionally allows the tracks of the two beta particles to be recorded, which are expected to have a length of up to 30 cm at 10 bar pressure. The ability to record the topological signature of the neutrinoless double-beta events provides a powerful background rejection factor for the double-beta experiment. In this paper, we present a novel 3D imaging concept using SiPMs coated with tetraphenyl butadiene (TPB) for the EL read out and its first implementation in NEXT-DEMO, a large-scale prototype of the NEXT-100 experiment. The design and the first characterization measurements of the NEXT-DEMO SiPM tracking system are presented. The SiPM response uniformity over the tracking plane drawn from its gain map is shown to be better than 4%. An automated active control system for the stabilization of the SiPMs gain was developed, based on the voltage supply compensation of the gain drifts. The gain is shown to be stabilized within 0.2% relative variation around its nominal value, provided by Hamamatsu, in a temperature range of 10 degree C. The noise level from the electronics and the SiPM dark noise is shown to lay typically below the level of 10 photoelectrons (pe) in the ADC. Hence, a detection threshold at 10 pe is set for the acquisition of the tracking signals. The ADC full dynamic range (4096 channels) is shown to be adequate for signal levels of up to 200 pe/microsecond, which enables recording most of the tracking signals.
  • The NEXT-100 experiment for neutrinoless double beta decay searches (Conceptual Design Report) (1106.3630)

    NEXT Collaboration: V. Álvarez, M. Ball, M. Batallé, J. Bayarri, F.I.G. Borges, S. Cárcel, J.M. Carmona, J. Castel, J.M. Catalá, S. Cebrián, A. Cervera-Villanueva, D. Chan, C.A.N. Conde, T. Dafni, T.H.V.T. Dias, J. Díaz, R. Esteve, P. Evtoukhovitch, L.M.P. Fernandes, P. Ferrario, E. Ferrer-Ribas, A.L. Ferreira, E.D.C. Freitas, A. Gil, I. Giomataris, A. Goldschmidt, E. Gómez, H. Gómez, J.J. Gómez-Cadenas, K. Gónzález, R.M. Gutiérrez, J.A. Hernando-Morata, D.C. Herrera, V. Herrero, F. Iguaz, I.G. Irastorza, V. Kalinnikov, A. Kustov, I. Liubarsky, J.A.M. Lopes, D. Lorca, M. Losada, G. Luzón, J. Martín-Albo, A. Méndez, T. Miller, A. Moisenko, J.P. Mols, F. Monrabal, C.M.B. Monteiro, J.M. Monzó, F.J. Mora, J. Muñoz-Vidal, H. Natal da Luz, G. Navarro, M. Nebot, D. Nygren, C.A.B. Oliveira, R. Palma, J.L. Pérez-Aparicio, J. Renner, L. Ripoll, A. Rodríguez, J. Rodríguez, F.P. Santos, J.M.F. dos Santos, L. Seguí, L. Serra, C. Sofka, M. Sorel, H. Spieler, J.F. Toledo, A. Tomás, Z. Tsamalaidze, D. Vázquez, E. Velicheva, J.F.C.A. Veloso, J.A. Villar, R. Webb, T. Weber, J. White, N. Yahlali
    June 18, 2011 hep-ex, physics.ins-det
    ... ... ... ... ... ...
    We propose an EASY (Electroluminescent ApparatuS of high Yield) and SOFT (Separated Optimized FuncTion) time-projection chamber for the NEXT experiment, that will search for neutrinoless double beta decay (bb0nu) in Xe-136. Our experiment must be competitive with the new generation of bb0nu searches already in operation or in construction. This requires a detector with very good energy resolution (<1%), very low background con- tamination (1E-4 counts/(keV \bullet kg \bullet y)) and large target mass. In addition, it needs to be operational as soon as possible. The design described here optimizes energy resolution thanks to the use of proportional electroluminescent amplification (EL); it is compact, as the Xe gas is under high pressure; and it allows the measurement of the topological signature of the event to further reduce the background contamination. The SOFT design uses different sensors for tracking and calorimetry. We propose the use of SiPMs (MPPCs) coated with a suitable wavelength shifter for the tracking, and the use of radiopure photomultipliers for the measurement of the energy and the primary scintillation needed to estimate the t0. This design provides the best possible energy resolution compared with other NEXT designs based on avalanche gain devices. The baseline design is an Asymmetric Neutrino Gas EL apparatus (ANGEL), which was already outlined in the NEXT LOI. ANGEL is conceived to be easy to fabricate. It requires very little R&D and most of the proposed solutions have already been tested in the NEXT-1 prototypes. Therefore, the detector can be ready by 2013. In this Conceptual Design Report (CDR) we discuss first the physics case, present a full design of the detector, describe the NEXT-1 EL prototypes and their initial results, and outline a project to build a detector with 100 kg of enriched xenon to be installed in the Canfranc Underground Laboratory in 2013.