We present a novel electrical technique to measure the tension of wires in
multi-wire drift chambers. We create alternating electric fields by biasing
adjacent wires on both sides of a test wire with a superposition of positive
and negative DC voltages on an AC signal ($V_{\rm AC} \pm V_{\rm DC}$). The
resulting oscillations of the wire will display a resonance at its natural
frequency, and the corresponding change of the capacitance will lead to a
measurable current. This scheme is scalable to multiple wires and therefore
enables us to precisely measure the tension of a large number of wires in a
short time. It can also be applied at cryogenic temperatures making it an
attractive solution for future large time-projection chambers such as the DUNE
detector. We present the concept, an example implementation and its performance
in a real-world scenario and discuss the limitations of the sensitivity of the
system in terms of voltage and wire length.
-
The single-phase liquid argon time projection chamber (LArTPC) provides a
large amount of detailed information in the form of fine-grained drifted
ionization charge from particle traces. To fully utilize this information, the
deposited charge must be accurately extracted from the raw digitized waveforms
via a robust signal processing chain. Enabled by the ultra-low noise levels
associated with cryogenic electronics in the MicroBooNE detector, the precise
extraction of ionization charge from the induction wire planes in a
single-phase LArTPC is qualitatively demonstrated on MicroBooNE data with event
display images, and quantitatively demonstrated via waveform-level and
track-level metrics. Improved performance of induction plane calorimetry is
demonstrated through the agreement of extracted ionization charge measurements
across different wire planes for various event topologies. In addition to the
comprehensive waveform-level comparison of data and simulation, a calibration
of the cryogenic electronics response is presented and solutions to various
MicroBooNE-specific TPC issues are discussed. This work presents an important
improvement in LArTPC signal processing, the foundation of reconstruction and
therefore physics analyses in MicroBooNE.
-
We describe the concept and procedure of drifted-charge extraction developed
in the MicroBooNE experiment, a single-phase liquid argon time projection
chamber (LArTPC). This technique converts the raw digitized TPC waveform to the
number of ionization electrons passing through a wire plane at a given time. A
robust recovery of the number of ionization electrons from both induction and
collection anode wire planes will augment the 3D reconstruction, and is
particularly important for tomographic reconstruction algorithms. A number of
building blocks of the overall procedure are described. The performance of the
signal processing is quantitatively evaluated by comparing extracted charge
with the true charge through a detailed TPC detector simulation taking into
account position-dependent induced current inside a single wire region and
across multiple wires. Some areas for further improvement of the performance of
the charge extraction procedure are also discussed.
-
We discuss a technique for measuring a charged particle's momentum by means
of multiple Coulomb scattering (MCS) in the MicroBooNE liquid argon time
projection chamber (LArTPC). This method does not require the full particle
ionization track to be contained inside of the detector volume as other track
momentum reconstruction methods do (range-based momentum reconstruction and
calorimetric momentum reconstruction). We motivate use of this technique,
describe a tuning of the underlying phenomenological formula, quantify its
performance on fully contained beam-neutrino-induced muon tracks both in
simulation and in data, and quantify its performance on exiting muon tracks in
simulation. Using simulation, we have shown that the standard Highland formula
should be re-tuned specifically for scattering in liquid argon, which
significantly improves the bias and resolution of the momentum measurement.
With the tuned formula, we find agreement between data and simulation for
contained tracks, with a small bias in the momentum reconstruction and with
resolutions that vary as a function of track length, improving from about 10%
for the shortest (one meter long) tracks to 5% for longer (several meter)
tracks. For simulated exiting muons with at least one meter of track contained,
we find a similarly small bias, and a resolution which is less than 15% for
muons with momentum below 2 GeV/c. Above 2 GeV/c, results are given as a first
estimate of the MCS momentum measurement capabilities of MicroBooNE for high
momentum exiting tracks.
-
The MicroBooNE liquid argon time projection chamber (LArTPC) has been taking
data at Fermilab since 2015 collecting, in addition to neutrino beam,
cosmic-ray muons. Results are presented on the reconstruction of Michel
electrons produced by the decay at rest of cosmic-ray muons. Michel electrons
are abundantly produced in the TPC, and given their well known energy spectrum
can be used to study MicroBooNE's detector response to low-energy electrons
(electrons with energies up to ~50 MeV). We describe the fully-automated
algorithm developed to reconstruct Michel electrons, with which a sample of
~14,000 Michel electron candidates is obtained. Most of this article is
dedicated to studying the impact of radiative photons produced by Michel
electrons on the accuracy and resolution of their energy measurement. In this
energy range, ionization and bremsstrahlung photon production contribute
similarly to electron energy loss in argon, leading to a complex electron
topology in the TPC. By profiling the performance of the reconstruction
algorithm on simulation we show that the ability to identify and include energy
deposited by radiative photons leads to a significant improvement in the energy
measurement of low-energy electrons. The fractional energy resolution we
measure improves from over 30% to ~20% when we attempt to include radiative
photons in the reconstruction. These studies are relevant to a large number of
analyses which aim to study neutrinos by measuring electrons produced by
$\nu_e$ interactions over a broad energy range.
-
The MicroBooNE detector is a liquid argon time projection chamber at Fermilab
designed to study short-baseline neutrino oscillations and neutrino-argon
interaction cross-section. Due to its location near the surface, a good
understanding of cosmic muons as a source of backgrounds is of fundamental
importance for the experiment. We present a method of using an external 0.5 m
(L) x 0.5 m (W) muon counter stack, installed above the main detector, to
determine the cosmic-ray reconstruction efficiency in MicroBooNE. Data are
acquired with this external muon counter stack placed in three different
positions, corresponding to cosmic rays intersecting different parts of the
detector. The data reconstruction efficiency of tracks in the detector is found
to be $\epsilon_{\mathrm{data}}=(97.1\pm0.1~(\mathrm{stat}) \pm
1.4~(\mathrm{sys}))\%$, in good agreement with the Monte Carlo reconstruction
efficiency $\epsilon_{\mathrm{MC}} = (97.4\pm0.1)\%$. This analysis represents
a small-scale demonstration of the method that can be used with future data
coming from a recently installed cosmic-ray tagger system, which will be able
to tag $\approx80\%$ of the cosmic rays passing through the MicroBooNE
detector.
-
ProtoDUNE-SP is the single-phase DUNE Far Detector prototype that is under
construction and will be operated at the CERN Neutrino Platform (NP) starting
in 2018. ProtoDUNE-SP, a crucial part of the DUNE effort towards the
construction of the first DUNE 10-kt fiducial mass far detector module (17 kt
total LAr mass), is a significant experiment in its own right. With a total
liquid argon (LAr) mass of 0.77 kt, it represents the largest monolithic
single-phase LArTPC detector to be built to date. It's technical design is
given in this report.
-
The low-noise operation of readout electronics in a liquid argon time
projection chamber (LArTPC) is critical to properly extract the distribution of
ionization charge deposited on the wire planes of the TPC, especially for the
induction planes. This paper describes the characteristics and mitigation of
the observed noise in the MicroBooNE detector. The MicroBooNE's single-phase
LArTPC comprises two induction planes and one collection sense wire plane with
a total of 8256 wires. Current induced on each TPC wire is amplified and shaped
by custom low-power, low-noise ASICs immersed in the liquid argon. The
digitization of the signal waveform occurs outside the cryostat. Using data
from the first year of MicroBooNE operations, several excess noise sources in
the TPC were identified and mitigated. The residual equivalent noise charge
(ENC) after noise filtering varies with wire length and is found to be below
400 electrons for the longest wires (4.7 m). The response is consistent with
the cold electronics design expectations and is found to be stable with time
and uniform over the functioning channels. This noise level is significantly
lower than previous experiments utilizing warm front-end electronics.
-
Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre
Auger Observatory to extend its range of detection and to directly measure the
muon content of the particle showers. It consists of an infill of surface
water-Cherenkov detectors accompanied by buried scintillator detectors used for
muon counting. The main objectives of the AMIGA engineering array, referred to
as the Unitary Cell, are to identify and resolve all engineering issues as well
as to understand the muon-number counting uncertainties related to the design
of the detector. The mechanical design, fabrication and deployment processes of
the muon counters of the Unitary Cell are described in this document. These
muon counters modules comprise sealed PVC casings containing plastic
scintillation bars, wavelength-shifter optical fibers, 64 pixel photomultiplier
tubes, and acquisition electronics. The modules are buried approximately 2.25 m
below ground level in order to minimize contamination from electromagnetic
shower particles. The mechanical setup, which allows access to the electronics
for maintenance, is also described in addition to tests of the modules'
response and integrity. The completed Unitary Cell has measured a number of air
showers of which a first analysis of a sample event is included here.
-
To exploit the full potential of radio measurements of cosmic-ray air showers
at MHz frequencies, a detector timing synchronization within 1 ns is needed.
Large distributed radio detector arrays such as the Auger Engineering Radio
Array (AERA) rely on timing via the Global Positioning System (GPS) for the
synchronization of individual detector station clocks. Unfortunately, GPS
timing is expected to have an accuracy no better than about 5 ns. In practice,
in particular in AERA, the GPS clocks exhibit drifts on the order of tens of
ns. We developed a technique to correct for the GPS drifts, and an independent
method is used for cross-checks that indeed we reach nanosecond-scale timing
accuracy by this correction. First, we operate a "beacon transmitter" which
emits defined sine waves detected by AERA antennas recorded within the physics
data. The relative phasing of these sine waves can be used to correct for GPS
clock drifts. In addition to this, we observe radio pulses emitted by
commercial airplanes, the position of which we determine in real time from
Automatic Dependent Surveillance Broadcasts intercepted with a software-defined
radio. From the known source location and the measured arrival times of the
pulses we determine relative timing offsets between radio detector stations. We
demonstrate with a combined analysis that the two methods give a consistent
timing calibration with an accuracy of 2 ns or better. Consequently, the beacon
method alone can be used in the future to continuously determine and correct
for GPS clock drifts in each individual event measured by AERA.
-
This paper presents the results of different searches for correlations
between very high-energy neutrino candidates detected by IceCube and the
highest-energy cosmic rays measured by the Pierre Auger Observatory and the
Telescope Array. We first consider samples of cascade neutrino events and of
high-energy neutrino-induced muon tracks, which provided evidence for a
neutrino flux of astrophysical origin, and study their cross-correlation with
the ultrahigh-energy cosmic ray (UHECR) samples as a function of angular
separation. We also study their possible directional correlations using a
likelihood method stacking the neutrino arrival directions and adopting
different assumptions on the size of the UHECR magnetic deflections. Finally,
we perform another likelihood analysis stacking the UHECR directions and using
a sample of through-going muon tracks optimized for neutrino point-source
searches with sub-degree angular resolution. No indications of correlations at
discovery level are obtained for any of the searches performed. The smallest of
the p-values comes from the search for correlation between UHECRs with IceCube
high-energy cascades, a result that should continue to be monitored.
-
This document presents the Conceptual Design Report (CDR) put forward by an
international neutrino community to pursue the Deep Underground Neutrino
Experiment at the Long-Baseline Neutrino Facility (LBNF/DUNE), a groundbreaking
science experiment for long-baseline neutrino oscillation studies and for
neutrino astrophysics and nucleon decay searches. The DUNE far detector will be
a very large modular liquid argon time-projection chamber (LArTPC) located deep
underground, coupled to the LBNF multi-megawatt wide-band neutrino beam. DUNE
will also have a high-resolution and high-precision near detector.
-
Detection of scintillation light can play several important roles in LArTPCs.
Increased collection efficiency could result in the improvement of time,
energy, and position resolution. The SBND collaboration is developing detailed
MC simulations to study the performance of different types of light systems in
the LArSoft framework. Due to the vast number of photons typically produced in
neutrino physics events, a full optical simulation becomes extremely hard to
run on reasonable time scales. I will describe how the SBND simulation tackles
these problems and its current status for two of the light detection systems
considered by SBND: (i) a traditional TPB-coated PMT based system and (ii) a
system based on TPB-coated reflector foils to increase collection efficiency
without increasing the number of photodetectors.
-
Joint contributions of the Pierre Auger Collaboration and the Telescope Array
Collaboration to the 34th International Cosmic Ray Conference, 30 July - 6
August 2015, The Hague, The Netherlands.
-
We have conducted three searches for correlations between ultra-high energy
cosmic rays detected by the Telescope Array and the Pierre Auger Observatory,
and high-energy neutrino candidate events from IceCube. Two cross-correlation
analyses with UHECRs are done: one with 39 cascades from the IceCube
`high-energy starting events' sample and the other with 16 high-energy `track
events'. The angular separation between the arrival directions of neutrinos and
UHECRs is scanned over. The same events are also used in a separate search
using a maximum likelihood approach, after the neutrino arrival directions are
stacked. To estimate the significance we assume UHECR magnetic deflections to
be inversely proportional to their energy, with values $3^\circ$, $6^\circ$ and
$9^\circ$ at 100 EeV to allow for the uncertainties on the magnetic field
strength and UHECR charge. A similar analysis is performed on stacked UHECR
arrival directions and the IceCube sample of through-going muon track events
which were optimized for neutrino point-source searches.
-
Contributions of the Pierre Auger Collaboration to the 34th International
Cosmic Ray Conference, 30 July - 6 August 2015, The Hague, The Netherlands
-
We describe the method devised to reconstruct inclined cosmic-ray air showers
with zenith angles greater than $60^\circ$ detected with the surface array of
the Pierre Auger Observatory. The measured signals at the ground level are
fitted to muon density distributions predicted with atmospheric cascade models
to obtain the relative shower size as an overall normalization parameter. The
method is evaluated using simulated showers to test its performance. The energy
of the cosmic rays is calibrated using a sub-sample of events reconstructed
with both the fluorescence and surface array techniques. The reconstruction
method described here provides the basis of complementary analyses including an
independent measurement of the energy spectrum of ultra-high energy cosmic rays
using very inclined events collected by the Pierre Auger Observatory.
-
A flux of neutrons from an astrophysical source in the Galaxy can be detected
in the Pierre Auger Observatory as an excess of cosmic-ray air showers arriving
from the direction of the source. To avoid the statistical penalty for making
many trials, classes of objects are tested in combinations as nine "target
sets", in addition to the search for a neutron flux from the Galactic Center or
from the Galactic Plane. Within a target set, each candidate source is weighted
in proportion to its electromagnetic flux, its exposure to the Auger
Observatory, and its flux attenuation factor due to neutron decay. These
searches do not find evidence for a neutron flux from any class of candidate
sources. Tabulated results give the combined p-value for each class, with and
without the weights, and also the flux upper limit for the most significant
candidate source within each class. These limits on fluxes of neutrons
significantly constrain models of EeV proton emission from non-transient
discrete sources in the Galaxy.
-
Measurements of air showers made using the hybrid technique developed with
the fluorescence and surface detectors of the Pierre Auger Observatory allow a
sensitive search for point sources of EeV photons anywhere in the exposed sky.
A multivariate analysis reduces the background of hadronic cosmic rays. The
search is sensitive to a declination band from -85{\deg} to +20{\deg}, in an
energy range from 10^17.3 eV to 10^18.5 eV. No photon point source has been
detected. An upper limit on the photon flux has been derived for every
direction. The mean value of the energy flux limit that results from this,
assuming a photon spectral index of -2, is 0.06 eV cm^-2 s^-1, and no celestial
direction exceeds 0.25 eV cm^-2 s^-1. These upper limits constrain scenarios in
which EeV cosmic ray protons are emitted by non-transient sources in the
Galaxy.
-
The Pierre Auger Observatory is the world's largest cosmic ray observatory.
Our current exposure reaches nearly 40,000 km$^2$ str and provides us with an
unprecedented quality data set. The performance and stability of the detectors
and their enhancements are described. Data analyses have led to a number of
major breakthroughs. Among these we discuss the energy spectrum and the
searches for large-scale anisotropies. We present analyses of our X$_{max}$
data and show how it can be interpreted in terms of mass composition. We also
describe some new analyses that extract mass sensitive parameters from the 100%
duty cycle SD data. A coherent interpretation of all these recent results opens
new directions. The consequences regarding the cosmic ray composition and the
properties of UHECR sources are briefly discussed.
-
Joint contributions of the Pierre Auger and Telescope Array Collaborations to
the 33rd International Cosmic Ray Conference, Rio de Janeiro, Brazil, July
2013: cross-calibration of the fluorescence telescopes, large scale
anisotropies and mass composition.
-
The Pierre Auger Observatory is exploring the potential of the radio
detection technique to study extensive air showers induced by ultra-high energy
cosmic rays. The Auger Engineering Radio Array (AERA) addresses both
technological and scientific aspects of the radio technique. A first phase of
AERA has been operating since September 2010 with detector stations observing
radio signals at frequencies between 30 and 80 MHz. In this paper we present
comparative studies to identify and optimize the antenna design for the final
configuration of AERA consisting of 160 individual radio detector stations. The
transient nature of the air shower signal requires a detailed description of
the antenna sensor. As the ultra-wideband reception of pulses is not widely
discussed in antenna literature, we review the relevant antenna characteristics
and enhance theoretical considerations towards the impulse response of antennas
including polarization effects and multiple signal reflections. On the basis of
the vector effective length we study the transient response characteristics of
three candidate antennas in the time domain. Observing the variation of the
continuous galactic background intensity we rank the antennas with respect to
the noise level added to the galactic signal.
-
The Pierre Auger Observatory is a facility built to detect air showers
produced by cosmic rays above 10^17 eV. During clear nights with a low
illuminated moon fraction, the UV fluorescence light produced by air showers is
recorded by optical telescopes at the Observatory. To correct the observations
for variations in atmospheric conditions, atmospheric monitoring is performed
at regular intervals ranging from several minutes (for cloud identification) to
several hours (for aerosol conditions) to several days (for vertical profiles
of temperature, pressure, and humidity). In 2009, the monitoring program was
upgraded to allow for additional targeted measurements of atmospheric
conditions shortly after the detection of air showers of special interest,
e.g., showers produced by very high-energy cosmic rays or showers with atypical
longitudinal profiles. The former events are of particular importance for the
determination of the energy scale of the Observatory, and the latter are
characteristic of unusual air shower physics or exotic primary particle types.
The purpose of targeted (or "rapid") monitoring is to improve the resolution of
the atmospheric measurements for such events. In this paper, we report on the
implementation of the rapid monitoring program and its current status. The
rapid monitoring data have been analyzed and applied to the reconstruction of
air showers of high interest, and indicate that the air fluorescence
measurements affected by clouds and aerosols are effectively corrected using
measurements from the regular atmospheric monitoring program. We find that the
rapid monitoring program has potential for supporting dedicated physics
analyses beyond the standard event reconstruction.
-
The Surface Detector of the Pierre Auger Observatory is sensitive to
neutrinos of all flavours above 0.1 EeV. These interact through charged and
neutral currents in the atmosphere giving rise to extensive air showers. When
interacting deeply in the atmosphere at nearly horizontal incidence, neutrinos
can be distinguished from regular hadronic cosmic rays by the broad time
structure of their shower signals in the water-Cherenkov detectors. In this
paper we present for the first time an analysis based on down-going neutrinos.
We describe the search procedure, the possible sources of background, the
method to compute the exposure and the associated systematic uncertainties. No
candidate neutrinos have been found in data collected from 1 January 2004 to 31
May 2010. Assuming an E^-2 differential energy spectrum the limit on the single
flavour neutrino is (E^2 * dN/dE) < 1.74x10^-7 GeV cm^-2 s^-1 sr^-1 at 90% C.L.
in the energy range 1x10^17 eV < E < 1x10^20 eV.
-
Atmospheric conditions at the site of a cosmic ray observatory must be known
for reconstructing observed extensive air showers. The Global Data Assimilation
System (GDAS) is a global atmospheric model predicated on meteorological
measurements and numerical weather predictions. GDAS provides
altitude-dependent profiles of the main state variables of the atmosphere like
temperature, pressure, and humidity. The original data and their application to
the air shower reconstruction of the Pierre Auger Observatory are described. By
comparisons with radiosonde and weather station measurements obtained on-site
in Malarg\"ue and averaged monthly models, the utility of the GDAS data is
shown.