• Login
    Sort by: Relevance Date Users's collections Twitter
    Group by: Day Week Month Year All time
Based on the idea and the provided source code of Andrej Karpathy (arxiv-sanity)
2:3 1:1 3:2
  • Prime Focus Spectrograph (PFS) for the Subaru Telescope: Overview, recent progress, and future perspectives (1608.01075)

    Naoyuki Tamura, Naruhisa Takato, Atsushi Shimono, Yuki Moritani, Kiyoto Yabe, Yuki Ishizuka, Akitoshi Ueda, Yukiko Kamata, Hrand Aghazarian, Stephane Arnouts, Gabriel Barban, Robert H. Barkhouser, Renato C. Borges, David F. Braun, Michael A. Carr, Pierre-Yves Chabaud, Yin-Chang Chang, Hsin-Yo Chen, Masashi Chiba, Richard C. Y. Chou, You-Hua Chu, Judith G. Cohen, Rodrigo P. de Almeida, Antonio C. de Oliveira, Ligia S. de Oliveira, Richard G. Dekany, Kjetil Dohlen, Jesulino B. dos Santos, Leandro H. dos Santos, Richard S. Ellis, Maximilian Fabricius, Didier Ferrand, Decio Ferreira, Mirek Golebiowski, Jenny E. Greene, Johannes Gross, James E. Gunn, Randolph Hammond, Albert Harding, Murdock Hart, Timothy M. Heckman, Christopher M. Hirata, Paul Ho, Stephen C. Hope, Larry Hovland, Shu-Fu Hsu, Yen-Shan Hu, Ping-Jie Huang, Marc Jaquet, Yipeng Jing, Jennifer Karr, Masahiko Kimura, Matthew E. King, Eiichiro Komatsu, Vincent Le Brun, Olivier Le Fevre, Arnaud Le Fur, David Le Mignant, Hung-Hsu Ling, Craig P. Loomis, Robert H. Lupton, Fabrice Madec, Peter Mao, Lucas S. Marrara, Claudia Mendes de Oliveira, Yosuke Minowa, Chaz N. Morantz, Hitoshi Murayama, Graham J. Murray, Youichi Ohyama, Joseph Orndorff, Sandrine Pascal, Jefferson M. Pereira, Daniel J. Reiley, Martin Reinecke, Andreas Ritter, Mitsuko Roberts, Mark A. Schwochert, Michael D. Seiffert, Stephen A. Smee, Laerte Sodre Jr., David N. Spergel, Aaron J. Steinkraus, Michael A. Strauss, Christian Surace, Yasushi Suto, Nao Suzuki, John Swinbank, Philip J. Tait, Masahiro Takada, Tomonori Tamura, Yoko Tanaka, Laurence Tresse, Orlando Verducci Jr., Didier Vibert, Clement Vidal, Shiang-Yu Wang, Chih-Yi Wen, Chi-Hung Yan, Naoki Yasuda
    Aug. 3, 2016 astro-ph.CO, astro-ph.GA, astro-ph.IM
    ... ... ... ... ... ...
    PFS (Prime Focus Spectrograph), a next generation facility instrument on the 8.2-meter Subaru Telescope, is a very wide-field, massively multiplexed, optical and near-infrared spectrograph. Exploiting the Subaru prime focus, 2394 reconfigurable fibers will be distributed over the 1.3 deg field of view. The spectrograph has been designed with 3 arms of blue, red, and near-infrared cameras to simultaneously observe spectra from 380nm to 1260nm in one exposure at a resolution of ~1.6-2.7A. An international collaboration is developing this instrument under the initiative of Kavli IPMU. The project is now going into the construction phase aiming at undertaking system integration in 2017-2018 and subsequently carrying out engineering operations in 2018-2019. This article gives an overview of the instrument, current project status and future paths forward.
  • The Current Status of Prime Focus Instrument of Subaru Prime Focus Spectrograph (1608.00675)

    Shiang-Yu Wang, Mark A. Schwochert, Pin-Jie Huang, Hsin-Yo Chen, Masahiko Kimura, Richard C. Y. Chou, Yin-Chang Chang, Yen-Sang Hu, Hung-Hsu Ling, Chaz N. Morantz, Dan J. Reiley, Peter Mao, David F. Braun, Chih-Yi Wen, Chi-Hung Yan, Jennifer Karr, James E. Gunn, Graham Murray, Naoyuki Tamura, Naruhisa Takato, Atsushi Shimono, Decio Ferreira, Leandro Henriqu dos Santosh, Ligia Souza Oliveira, Antonio Cesar de Oliveira, Lucas Souza Marrara
    Aug. 2, 2016 astro-ph.IM
    The Prime Focus Spectrograph (PFS) is a new optical/near-infrared multi-fiber spectrograph design for the prime focus of the 8.2m Subaru telescope. PFS will cover 1.3 degree diameter field with 2394 fibers to complement the imaging capability of Hyper SuprimeCam (HSC). The prime focus unit of PFS called Prime Focus Instrument (PFI) provides the interface with the top structure of Subaru telescope and also accommodates the optical bench in which Cobra fiber positioners are located. In addition, the acquisition and guiding cameras (AGCs), the optical fiber positioner system, the cable wrapper, the fiducial fibers, illuminator, and viewer, the field element, and the telemetry system are located inside the PFI. The mechanical structure of the PFI was designed with special care such that its deflections sufficiently match those of the HSC's Wide Field Corrector (WFC) so the fibers will stay on targets over the course of the observations within the required accuracy. In this report, the latest status of PFI development will be given including the performance of PFI components, the setup and performance of the integration and testing equipment.
  • Prime Focus Spectrograph for the Subaru telescope: massively multiplexed optical and near-infrared fiber spectrograph (1507.00725)

    Hajime Sugai, Naoyuki Tamura, Hiroshi Karoji, Atsushi Shimono, Naruhisa Takato, Masahiko Kimura, Youichi Ohyama, Akitoshi Ueda, Hrand Aghazarian, Marcio Vital de Arruda, Robert H. Barkhouser, Charles L. Bennett, Steve Bickerton, Alexandre Bozier, David F. Braun, Khanh Bui, Christopher M. Capocasale, Michael A. Carr, Bruno Castilho, Yin-Chang Chang, Hsin-Yo Chen, Richard C.Y. Chou, Olivia R. Dawson, Richard G. Dekany, Eric M. Ek, Richard S. Ellis, Robin J. English, Didier Ferrand, Décio Ferreira, Charles D. Fisher, Mirek Golebiowski, James E. Gunn, Murdock Hart, Timothy M. Heckman, Paul T. P. Ho, Stephen Hope, Larry E. Hovland, Shu-Fu Hsu, Yen-Shan Hu, Pin Jie Huang, Marc Jaquet, Jennifer E. Karr, Jason G. Kempenaar, Matthew E. King, Olivier Le Fèvre, David Le Mignant, Hung-Hsu Ling, Craig Loomis, Robert H. Lupton, Fabrice Madec, Peter Mao, Lucas Souza Marrara, Brice Ménard, Chaz Morantz, Hitoshi Murayama, Graham J. Murray, Antonio Cesar de Oliveira, Claudia Mendes de Oliveira, Ligia Souza de Oliveira, Joe D. Orndorff, Rodrigo de Paiva Vilaça, Eamon J. Partos, Sandrine Pascal, Thomas Pegot-Ogier, Daniel J. Reiley, Reed Riddle, Leandro Santos, Jesulino Bispo dos Santos, Mark A. Schwochert, Michael D. Seiffert, Stephen A. Smee, Roger M. Smith, Ronald E. Steinkraus, Laerte Sodré Jr, David N. Spergel, Christian Surace, Laurence Tresse, Clément Vidal, Sebastien Vives, Shiang-Yu Wang, Chih-Yi Wen, Amy C. Wu, Rosie Wyse, Chi-Hung Yan
    July 2, 2015 astro-ph.IM
    The Prime Focus Spectrograph (PFS) is an optical/near-infrared multifiber spectrograph with 2394 science fibers distributed across a 1.3-deg diameter field of view at the Subaru 8.2-m telescope. The wide wavelength coverage from 0.38 {\mu}m to 1.26 {\mu}m, with a resolving power of 3000, simultaneously strengthens its ability to target three main survey programs: cosmology, galactic archaeology and galaxy/AGN evolution. A medium resolution mode with a resolving power of 5000 for 0.71 {\mu}m to 0.89 {\mu}m will also be available by simply exchanging dispersers. We highlight some of the technological aspects of the design. To transform the telescope focal ratio, a broad-band coated microlens is glued to each fiber tip. A higher transmission fiber is selected for the longest part of the cable system, optimizing overall throughput; a fiber with low focal ratio degradation is selected for the fiber-positioner and fiber-slit components, minimizing the effects of fiber movements and fiber bending. Fiber positioning will be performed by a positioner consisting of two stages of piezo-electric rotary motors. The positions of these motors are measured by taking an image of artificially back-illuminated fibers with the metrology camera located in the Cassegrain container; the fibers are placed in the proper location by iteratively measuring and then adjusting the positions of the motors. Target light reaches one of the four identical fast-Schmidt spectrograph modules, each with three arms. The PFS project has passed several project-wide design reviews and is now in the construction phase.
  • Progress with the Prime Focus Spectrograph for the Subaru Telescope: a massively multiplexed optical and near-infrared fiber spectrograph (1408.2825)

    Hajime Sugai, Naoyuki Tamura, Hiroshi Karoji, Atsushi Shimono, Naruhisa Takato, Masahiko Kimura, Youichi Ohyama, Akitoshi Ueda, Hrand Aghazarian, Marcio Vital de Arruda, Robert H. Barkhouser, Charles L. Bennett, Steve Bickerton, Alexandre Bozier, David F. Braun, Khanh Bui, Christopher M. Capocasale, Michael A. Carr, Bruno Castilho, Yin-Chang Chang, Hsin-Yo Chen, Richard C.Y. Chou, Olivia R. Dawson, Richard G. Dekany, Eric M. Ek, Richard S. Ellis, Robin J. English, Didier Ferrand, Décio Ferreira, Charles D. Fisher, Mirek Golebiowski, James E. Gunn, Murdock Hart, Timothy M. Heckman, Paul T. P. Ho, Stephen Hope, Larry E. Hovland, Shu-Fu Hsuc, Yen-Shan Hu, Pin Jie Huang, Marc Jaquet, Jennifer E. Karr, Jason G. Kempenaar, Matthew E. King, Olivier Le Fèvre, David Le Mignant, Hung-Hsu Ling, Craig Loomis, Robert H. Lupton, Fabrice Madec, Peter Mao, Lucas Souza Marrara, Brice Ménard, Chaz Morantz, Hitoshi Murayama, Graham J. Murray, Antonio Cesar de Oliveira, Claudia Mendes de Oliveira, Ligia Souza de Oliveira, Joe D. Orndorff, Rodrigo de Paiva Vilaça, Eamon J. Partos, Sandrine Pascal, Thomas Pegot-Ogier, Daniel J. Reiley, Reed Riddle, Leandro Santos, Jesulino Bispo dos Santos, Mark A. Schwochert, Michael D. Seiffert, Stephen A. Smee, Roger M. Smith, Ronald E. Steinkraus, Laerte Sodré Jr, David N. Spergel, Christian Surace, Laurence Tresse, Clément Vidal, Sebastien Vives, Shiang-Yu Wang, Chih-Yi Wen, Amy C. Wu, Rosie Wyse, Chi-Hung Yan
    Aug. 12, 2014 astro-ph.IM
    The Prime Focus Spectrograph (PFS) is an optical/near-infrared multi-fiber spectrograph with 2394 science fibers, which are distributed in 1.3 degree diameter field of view at Subaru 8.2-meter telescope. The simultaneous wide wavelength coverage from 0.38 um to 1.26 um, with the resolving power of 3000, strengthens its ability to target three main survey programs: cosmology, Galactic archaeology, and galaxy/AGN evolution. A medium resolution mode with resolving power of 5000 for 0.71 um to 0.89 um also will be available by simply exchanging dispersers. PFS takes the role for the spectroscopic part of the Subaru Measurement of Images and Redshifts project, while Hyper Suprime-Cam works on the imaging part. To transform the telescope plus WFC focal ratio, a 3-mm thick broad-band coated glass-molded microlens is glued to each fiber tip. A higher transmission fiber is selected for the longest part of cable system, while one with a better FRD performance is selected for the fiber-positioner and fiber-slit components, given the more frequent fiber movements and tightly curved structure. Each Fiber positioner consists of two stages of piezo-electric rotary motors. Its engineering model has been produced and tested. Fiber positioning will be performed iteratively by taking an image of artificially back-illuminated fibers with the Metrology camera located in the Cassegrain container. The camera is carefully designed so that fiber position measurements are unaffected by small amounts of high special-frequency inaccuracies in WFC lens surface shapes. Target light carried through the fiber system reaches one of four identical fast-Schmidt spectrograph modules, each with three arms. Prototype VPH gratings have been optically tested. CCD production is complete, with standard fully-depleted CCDs for red arms and more-challenging thinner fully-depleted CCDs with blue-optimized coating for blue arms.
  • Fiber Optical Cable and Connector System (FOCCoS) for PFS/Subaru (1408.2847)

    Antonio Cesar de Oliveira, Lígia Souza de Oliveira, Márcio V. de Arruda, Lucas Souza Marrara, Leandro H. dos Santos, Décio Ferreira, Jesulino B. dos Santos, Josimar A. Rosa, Orlando V. Junior, Jeferson M. Pereira, Bruno Castilho, Clemens Gneiding, Laerte S. Junior, Claudia M. de Oliveira, James E. Gunn, Akitoshi Ueda, Naruhisa Takato, Atsushi Shimono, Hajime Sugai, Hiroshi Karoji, Masahiko Kimura, Naoyuki Tamura, Shiang-Yu Wang, Graham Murray, David Le Mignant, Fabrice Madec, Marc Jaquet, Sebastien Vives, Charlie Fisher, David Braun, Mark Schwochert, Daniel J. Reiley
    Aug. 12, 2014 astro-ph.IM
    FOCCoS, Fiber Optical Cable and Connector System, has the main function of capturing the direct light from the focal plane of Subaru Telescope using optical fibers, each one with a microlens in its tip, and conducting this light through a route containing connectors to a set of four spectrographs. The optical fiber cable is divided in 3 different segments called Cable A, Cable B and Cable C. Multi-fibers connectors assure precise connection among all optical fibers of the segments, providing flexibility for instrument changes. To assure strong and accurate connection, these sets are arranged inside two types of assemblies: the Tower Connector, for connection between Cable C and Cable B; and the Gang Connector, for connection between Cable B and Cable A. Throughput tests were made to evaluate the efficiency of the connections. A lifetime test connection is in progress. Cable C is installed inside the PFI, Prime Focus Instrument, where each fiber tip with a microlens is bonded to the end of the shaft of a 2-stage piezo-electric rotatory motor positioner; this assembly allows each fiber to be placed anywhere within its patrol region, which is 9.5mm diameter.. Each positioner uses a fiber arm to support the ferrule, the microlens, and the optical fiber. 2400 of these assemblies are arranged on a motor bench plate in a hexagonal-closed-packed disposition.
  • Slit device for FOCCoS, PFS, Subaru (1408.2848)

    Antonio Cesar de Oliveira, James E. Gunn, Ligia Souza de Oliveira, Marcio Vital de Arruda, Lucas Souza Marrara, Leandro Henrique dos Santos, Décio Ferreira, Jesulino Bispo dos Santos, Josimar Aparecido Rosa, Flavio Felipe Ribeiro, Rodrigo de Paiva Vilaça, Orlando Verducci Junior, Laerte Sodré Junior, Claudia Mendes de Oliveira
    Aug. 12, 2014 astro-ph.IM
    The Fiber Optical Cable and Connector System, FOCCoS, subsystem of the Prime Focus Spectrograph, PFS, for Subaru telescope, is responsible to feed four spectrographs with a set of optical fibers cables. The light injection for each spectrograph is assured by a convex curved slit with a linear array of 616 optical fibers. In this paper we present a design of a slit that ensures the right direction of the fibers by using masks of micro holes. This kind of mask is made by a technique called electroforming, which is able to produce a nickel plate with holes in a linear sequence. The precision error is around 1micron in the diameter and 1 micron in the positions of the holes. This nickel plate may be produced with a thickness between 50 and 200 microns, so it may be very flexible. This flexibility allows the mask to be bent into the shape necessary for a curved slit. The concept requires two masks, which we call Front Mask, and Rear Mask, separated by a gap that defines the thickness of the slit. The pitch and the diameter of the holes define the linear geometry of the slit; the curvature of each mask defines the angular geometry of the slit. Obviously, this assembly must be mounted inside a structure rigid and strong enough to be supported inside the spectrograph. This structure must have a CTE optimized to avoid displacement of the fibers or increased FRD of the fibers when the device is submitted to temperatures around 3 degrees Celsius, the temperature of operation of the spectrograph. We have produced two models. Both are mounted inside a very compact Invar case, and both have their front surfaces covered by a dark composite, to reduce stray light. Furthermore, we have conducted experiments with two different internal structures to minimize effects caused by temperature gradients.
  • Multi-fibers connectors systems for FOCCoS-PFS-Subaru (1408.2849)

    Antonio Cesar de Oliveira, Ligia Souza de Oliveira, Lucas Souza Marrara, Leandro Henrique dos Santos, Marcio Vital de Arruda, Jesulino Bispo dos Santos, Décio Ferreira, Josimar Aparecido Rosa, Rodrigo de Paiva Vilaca, Laerte Sodre Junior Claudia Mendes de Oliveira, James E. Gunn
    Aug. 12, 2014 astro-ph.IM
    The Fiber Optical Cable and Connector System (FOCCoS), provides optical connection between 2400 positioners and a set of spectrographs through optical fibers cables as part of PFS instrument for Subaru telescope. The optical fiber cable will be segmented in 3 parts along the route, cable A, cable B and cable C, connected by a set of multi-fiber connectors. The company USCONEC produces the multi-fiber connector under study. The USCONEC 32F model can connect 32 optical fibers in a 4 x 8 matrix arrangement. The ferrules are made of a durable composite, Polyphenylene Sulfide (PPS) based thermoplastic. The connections are held in place by a push-on/pull-off latch, and the connector can also be distinguished by a pair of metal guide pins that protrude from the front of the connector. Two fibers per connector will be used for monitoring the connection procedure. It was found to be easy to polish and it is small enough to be mounted in groups. Highly multiplexed instruments like PFS require a fiber connector system that can deliver excellent optical performance and reliability. PFS requires two different types of structures to organize the connectors. The Tower Connector system, with 80 multi-fiber connectors, will be a group of connectors for connecting cable B (Telescope Structure) with cable C (Positioners Plate). The Gang Connector system is a group of 8 gang connectors, each one with 12 multi-fibers connectors, for connecting cable B (Telescope Structure) with cable A (Spectrograph). The bench tests with these connector systems and the chosen fibers should measure the throughput of light and the stability after many connections and disconnections. In this paper we describe tests and procedures to evaluate the throughput and FRD increment. The lifetime of the ferrules is also in evaluation.
  • Polish device for FOCCoS/PFS slit system (1408.2853)

    Antonio Cesar de Oliveira, Ligia Souza de Oliveira, Marcio Vital de Arruda, Lucas Souza Marrara, Leandro Henrique dos Santos, Décio Ferreira, Jesulino Bispo dos Santos, Rodrigo de Paiva Vilaca, Josimar Aparecido Rosa, Laerte Sodre Junior, Claudia Mendes de Oliveira
    Aug. 12, 2014 physics.ins-det, astro-ph.IM
    The Fiber Optical Cable and Connector System, FOCCoS, for the Prime Focus Spectrograph, PFS, is responsible for transporting light from the Subaru Telescope focal plane to a set of four spectrographs. Each spectrograph will be fed by a convex curved slit with 616 optical fibers organized in a linear arrangement. The slit frontal surface is covered with a special dark composite, made with refractory oxide, which is able to sustain its properties with minimum quantities of abrasives during the polishing process; this stability is obtained This stability is obtained by the detachment of the refractory oxide nanoparticles, which then gently reinforce gently the polishing process and increase its the efficiency. The surface roughness measured in several samples after high performance polishing was about 0.01 microns. Furthermore, the time for obtaining a polished surface with this quality is about 10 times less than the time required for polishing a brass, glass or ceramic surface of the same size. In this paper, we describe the procedure developed for high quality polishing of this type of slit. The cylindrical polishing described here, uses cylindrical concave metal bases on which glass paper is based. The polishing process consists to use grid sequences of 30 microns, 12 microns, 9 microns, 5 microns, 3 microns, 1 micron and, finally, a colloidal silica on a chemical cloth. To obtain the maximum throughput, the surface of the fibers should be polished in such a way that they are optically flat and free from scratches. The optical fibers are inspected with a microscope at all stages of the polishing process to ensure high quality. The efficiency of the process may be improved by using a cylindrical concave composite base as a substrate suitable for diamond liquid solutions. Despite this process being completely by hand, the final result shows a very high quality.