• A significant fraction of the research effort at the Triangle Universities Nuclear Laboratory (TUNL) focuses on weak interaction studies and searches for physics beyond the Standard Model. One major effort is the development of a new experimental technique to search for the neutron electric dipole moment (nEDM) that offers the potential for a factor of 100 increase in sensitivity over existing measurements. The search for this moment has the potential to reveal new sources of time reversal (T) and charge-conjugation-and-parity (CP) violation and to challenge calculations that propose extensions to the Standard Model. We provide a brief overview of the experiment as a whole and discuss the work underway at TUNL as part of this effort.
  • We report the measurements of depolarization probabilities of polarized $^3$He in a rectangular acrylic cell with a deuterated tetraphenyl butadiene-doped deuterated polystyrene coating filled with superfluid $^4$He at $\sim$330 mk with a magnetic holding field of $\sim$7.3 G. We achieve a wall depolarization probability of $\sim1.0\times10^{-7}$. Such a surface will find application in a new experiment searching for the neutron electric dipole moment and other applications.
  • We report the first study of the depolarization behavior of spin polarized 3He in a mixture of 3He-4He at a temperature below the 4He Lambda point in a deuterated TetraPhenyl Butadiene-doped deuterated PolyStyrene (dTPB-dPS) coated acrylic cell. In our experiment the measured 3He relaxation time is due to the convolution of the 3He longitudinal relaxation time, T1, and the diffusion time constant of 3He in superfluid 4He since depolarization takes place on the walls. We have obtained a 3He relaxation time ~3000 seconds at a temperature around 1.9K. We have shown that it's possible to achieve values of wall depolarization probability on the order of (1-2)x10^-7 for polarized 3He in the superfluid 4He from a dTPB-dPS coated acrylic surface.
  • We report about the first results obtained with our Ultra High Vacuum cryostat recently commissioned at HMI to study Ultra Cold Neutrons(UCN) loss rate under low temperatures(down to 4K) and well controlled sample environment. Our analysis of the temperature dependence of UCN loss rate on Cu surface allowed us to rule out the subbarier model in support of the 1/v model and propose a reasonable explanation of the low temperature upscattering.
  • Ultra-cold neutrons (UCN) are neutrons with energies so low they can be stored in material bottles and magnetic traps. They have been used to provide the currently most accurate experiments on the neutron life time and electric dipole moment. UCN can be produced in superfluid Helium at significantly higher densities than by other methods. The predominant production process is usually by one phonon emission which can only occur at a single incident neutron energy because of momentum and energy conservation. However UCN can also be produced by multiphonon processes. It is the purpose of this work to examine this multiphonon production of UCN. We look at several different incident neutron spectra, including cases where the multiphonon production is significant, and see how the relative importance of multiphonon production is influenced by the incident spectrum.