The Mu2e experiment at Fermilab will search for the charged lepton flavor
violating process of neutrino-less $\mu \to e$ coherent conversion in the field
of an aluminum nucleus. Mu2e will reach a single event sensitivity of about
$2.5\cdot 10^{-17}$ that corresponds to four orders of magnitude improvements
with respect to the current best limit. The detector system consists of a straw
tube tracker and a crystal calorimeter made of undoped CsI coupled with Silicon
Photomultipliers. The calorimeter was designed to be operable in a harsh
environment where about 10 krad/year will be delivered in the hottest region
and work in presence of 1 T magnetic field. The calorimeter role is to perform
$\mu$/e separation to suppress cosmic muons mimiking the signal, while
providing a high level trigger and a seeding the track search in the tracker.
In this paper we present the calorimeter design and the latest R$\&$D results.
-
The Mu2e experiment is constructing a calorimeter consisting of 1,348 undoped
CsI crystals in two disks. Each crystal has a dimension of 34 x 34 x 200 mm,
and is readout by a large area silicon PMT array. A series of technical
specifications was defined according to physics requirements. Preproduction CsI
crystals were procured from three firms: Amcrys, Saint-Gobain and Shanghai
Institute of Ceramics. We report the quality assurance on crystal's
scintillation properties and their radiation hardness against ionization dose
and neutrons. With a fast decay time of 30 ns and a light output of more than
100 p.e./MeV measured with a bi-alkali PMT, undoped CsI crystals provide a
cost-effective solution for the Mu2e experiment.
-
The Mu2e experiment at Fermilab will search for Charged Lepton Flavor
Violating conversion of a muon to an electron in an atomic field. The Mu2e
detector is composed of a tracker, an electromagnetic calorimeter and an
external system, surrounding the solenoid, to veto cosmic rays. The calorimeter
plays an important role to provide: a) excellent particle identification
capabilities; b) a fast trigger filter; c) an easier tracker track
reconstruction. Two disks, located downstream of the tracker, contain 674 pure
CsI crystals each. Each crystal is read out by two arrays of UV-extended SiPMs.
The choice of the crystals and SiPMs has been finalized after a thorough test
campaign. A first small scale prototype consisting of 51 crystals and 102 SiPM
arrays has been exposed to an electron beam at the BTF (Beam Test Facility) in
Frascati. Although the readout electronics were not the final, results show
that the current design is able to meet the timing and energy resolution
required by the Mu2e experiment.
-
We propose an evolution of the Mu2e experiment, called Mu2e-II, that would
leverage advances in detector technology and utilize the increased proton
intensity provided by the Fermilab PIP-II upgrade to improve the sensitivity
for neutrinoless muon-to-electron conversion by one order of magnitude beyond
the Mu2e experiment, providing the deepest probe of charged lepton flavor
violation in the foreseeable future. Mu2e-II will use as much of the Mu2e
infrastructure as possible, providing, where required, improvements to the Mu2e
apparatus to accommodate the increased beam intensity and cope with the
accompanying increase in backgrounds.
-
The Mu2e Experiment at Fermilab will search for coherent, neutrino-less
conversion of negative muons into electrons in the field of an Aluminum
nucleus, $\mu^- + Al \to e^- +Al$. Data collection start is planned for the end
of 2021.
The dynamics of such charged lepton flavour violating (CLFV) process is well
modelled by a two-body decay, resulting in a mono-energetic electron with an
energy slightly below the muon rest mass. If no events are observed in three
years of running, Mu2e will set an upper limit on the ratio between the
conversion and the capture rates
%\convrate of $\leq 6\ \times\ 10^{-17}$ (@ 90$\%$ C.L.). R$_{\mu e} =
\frac{\mu^- + A(Z,N) \to e^- +A(Z,N)}{\mu^- + A(Z,N) \to \nu_{\mu} ^-
+A(Z-1,N)} $ of $\leq 6\ \times\ 10^{-17}$ (@ 90$\%$ C.L.).
This will improve the current limit of four order of magnitudes with respect
to the previous best experiment.
Mu2e complements and extends the current search for $\mu \to e \gamma$ decay
at MEG as well as the direct searches for new physics at the LHC. The
observation of such CLFV process could be clear evidence for New Physics beyond
the Standard Model. Given its sensitivity, Mu2e will be able to probe New
Physics at a scale inaccessible to direct searches at either present or planned
high energy colliders. To search for the muon conversion process, a very
intense pulsed beam of negative muons ($\sim 10^{10} \mu/$ sec) is stopped on
an Aluminum target inside a very long solenoid where the detector is also
located. The Mu2e detector is composed of a straw tube tracker and a CsI
crystals electromagnetic calorimeter. An overview of the physics motivations
for Mu2e, the current status of the experiment and the required performances
and design details of the calorimeter are presented.
-
The Mu2e experiment at Fermilab searches for the charged flavor violating
conversion of a muon into an electron in the Coulomb field of a nucleus. The
detector consists of a straw tube tracker and a CSI crystal electromagnetic
calorimeter, both housed in a superconducting solenoid. Both the front-end and
the digital electronics, located inside the cryostat, will be operated in
vacuum under a 1 T magnetic field, having to sustain the high flux of neutrons
and ionizing particles coming from the muons stopping target. These harsh
experimental conditions make the design of the calorimeter waveform digitizer
quite challenging. All the selected commercial devices must be tested
individually and qualified for radiation hardness and operation in high
magnetic field. At the moment the expected particles flux and spectra at the
digitizers location are not completely simulated and we are using initial rough
estimates to select the components for the first prototype. We are gaining
experience in the qualification procedures using the selected components but
the choice will be frozen only when dose and neutron flux simulations will be
completed. The experimental results of the first qualification campaign are
presented.
-
The NA62 experiment will begin taking data in 2015. Its primary purpose is a
10% measurement of the branching ratio of the ultrarare kaon decay $K^+ \to
\pi^+ \nu \bar{ \nu }$, using the decay in flight of kaons in an unseparated
beam with momentum 75 GeV/c.The detector and analysis technique are described
here.
-
The TOTEM Experiment is designed to measure the total proton-proton
cross-section with the luminosity-independent method and to study elastic and
diffractive pp scattering at the LHC. To achieve optimum forward coverage for
charged particles emitted by the pp collisions in the interaction point IP5,
two tracking telescopes, T1 and T2, are installed on each side of the IP in the
pseudorapidity region 3.1 < = |eta | < = 6.5, and special movable beam-pipe
insertions - called Roman Pots (RP) - are placed at distances of +- 147 m and
+- 220 m from IP5. This article describes in detail the working of the TOTEM
detector to produce physics results in the first three years of operation and
data taking at the LHC.
-
Proton-proton elastic scattering has been measured by the TOTEM experiment at
the CERN Large Hadron Collider at $\sqrt{s} = 7 $ TeV in special runs with the
Roman Pot detectors placed as close to the outgoing beam as seven times the
transverse beam size. The differential cross-section measurements are reported
in the |t|-range of 0.36 to 2.5 GeV^2. Extending the range of data to low t
values from 0.02 to 0.33 GeV^2,and utilizing the luminosity measurements of
CMS, the total proton-proton cross section at sqrt(s) = 7 TeV is measured to be
(98.3 +- 0.2(stat) +- 2.8(syst)) mb.
-
Proton-proton elastic scattering has been measured by the TOTEM experiment at
the CERN Large Hadron Collider at {\surd}s = 7 TeV in dedicated runs with the
Roman Pot detectors placed as close as seven times the transverse beam size
(sbeam) from the outgoing beams. After careful study of the accelerator optics
and the detector alignment, |t|, the square of four-momentum transferred in the
elastic scattering process, has been determined with an uncertainty of d t =
0.1GeV p|t|. In this letter, first results of the differential cross section
are presented covering a |t|-range from 0.36 to 2.5GeV2. The differential
cross-section in the range 0.36 < |t| < 0.47 GeV2 is described by an
exponential with a slope parameter B = (23.6{\pm}0.5stat {\pm}0.4syst)GeV-2,
followed by a significant diffractive minimum at |t| =
(0.53{\pm}0.01stat{\pm}0.01syst)GeV2. For |t|-values larger than ~ 1.5GeV2, the
cross-section exhibits a power law behaviour with an exponent of -7.8_\pm}
0.3stat{\pm}0.1syst. When compared to predictions based on the different
available models, the data show a strong discriminative power despite the small
t-range covered.
-
2nd workshop on the implications of HERA for LHC physics. Working groups:
Parton Density Functions Multi-jet final states and energy flows Heavy quarks
(charm and beauty) Diffraction Cosmic Rays Monte Carlos and Tools
-
The TOTEM experiment at the LHC measures the total proton-proton cross
section with the luminosity-independent method and the elastic proton-proton
cross-section over a wide |t|-range. It also performs a comprehensive study of
diffraction, spanning from cross-section measurements of individual diffractive
processes to the analysis of their event topologies. Hard diffraction will be
studied in collaboration with CMS taking advantage of the large common rapidity
coverage for charged and neutral particle detection and the large variety of
trigger possibilities even at large luminosities. TOTEM will take data under
all LHC beam conditions including standard high luminosity runs to maximize its
physics reach. This contribution describes the main features of the TOTEM
physics programme including measurements to be made in the early LHC runs. In
addition, a novel scheme to extend the diffractive proton acceptance for high
luminosity runs by installing proton detectors at IP3 is described.