• An array of eight CsI(Tl) detectors has been set up to measure the light charged particles in nuclear reactions using heavy ions from the Pelletron Linac Facility, Mumbai. The energy response of CsI(Tl) detector to $\alpha$-particles from 5 to 40 MeV is measured using radioactive sources and the $^{12}$C($^{12}$C, $\alpha$) reaction populating discrete states in $^{20}$Ne. The energy non-linearity and the count rate effect on the pulse shape discrimination property have also been measured and observed the deterioration of pulse shape discrimination with higher count rate.
  • The response of the liquid scintillator (EJ-301 equivalent to NE-213) to the monoenergetic electrons produced in Compton scattered $\gamma$-ray tagging has been carried out for various radioactive $\gamma$-ray sources. The measured electron response is found to be linear up to $\sim$4~MeVee and the resolution of the liquid scintillator at 1~MeVee is observed to be $\sim$~11\%. The pulse shape discrimination and pulse height response of the liquid scintillator for neutrons has been measured using $^7$Li(p,n$_1$)$^7$Be*(0.429 MeV) reaction. Non linear response to mono-energetic neutrons for the liquid scintillator is observed at E$_n$=5.3, 9.0 and 12.7 MeV. The measured response of the liquid scintillator for electrons and neutrons have been compared with Geant4 simulation.
  • An earlier measurement on the 4$^+$ to 2$^+$ radiative transition in $^8$Be provided the first electromagnetic signature of its dumbbell-like shape. However, the large uncertainty in the measured cross section does not allow a stringent test of nuclear structure models. The present paper reports a more elaborate and precise measurement for this transition, via the radiative capture in the $^4$He+$^4$He reaction, improving the accuracy by about a factor of three. The {\it ab initio} calculations of the radiative transition strength with improved three-nucleon forces are also presented. The experimental results are compared with the predictions of the alpha cluster model and {\it ab initio} calculations.
  • A large area plastic scintillator detector array(~ 1 m x1m) has been set up for fast neutron spectroscopy at the BARC-TIFR Pelletron laboratory, Mumbai. The energy, time and position response has been measured for electrons using radioactive sources and for mono-energetic neutrons using the 7Li(p,n1)7Be*(0.429 MeV) reaction at proton energies between 6.3 and 19 MeV. A Monte Carlo simulation of the energy dependent efficiency of the array for neutron detection is in agreement with the 7Li(p,n1) measurements. The array has been used to measure the neutron spectrum, in the energy range of 4-12 MeV, in the reaction 12C+ 93Nb at E(12C)= 40 MeV. This is in reasonable agreement with a statistical model calculation.