This release includes data and information necessary to perform independent
analyses of the COHERENT result presented in Akimov et al., arXiv:1708.01294
[nucl-ex]. Data is shared in a binned, text-based format, including both
"signal" and "background" regions, so that counts and associated uncertainties
can be quantitatively calculated for the purpose of separate analyses. This
document describes the included information and its format, offering some
guidance on use of the data. Accompanying code examples show basic interaction
with the data using Python.
-
The primary goal of the COHERENT collaboration is to measure and study
coherent elastic neutrino-nucleus scattering (CEvNS) using the high-power,
few-tens-of-MeV, pulsed source of neutrinos provided by the Spallation Neutron
Source (SNS) at Oak Ridge National Laboratory (ORNL). The COHERENT
collaboration reported the first detection of CEvNS [Akimov:2017ade] using a
CsI[Na] detector. At present the collaboration is deploying four detector
technologies: a CsI[Na] scintillating crystal, p-type point-contact germanium
detectors, single-phase liquid argon, and NaI[Tl] crystals. All detectors are
located in the neutron-quiet basement of the SNS target building at distances
20-30 m from the SNS neutrino source. The simultaneous measurement in all four
COHERENT detector subsystems will test the $N^2$ dependence of the cross
section and search for new physics. In addition, COHERENT is measuring
neutrino-induced neutrons from charged- and neutral-current neutrino
interactions on nuclei in shielding materials, which represent a non-negligible
background for CEvNS as well as being of intrinsic interest. The Collaboration
is planning as well to look for charged-current interactions of relevance to
supernova and weak-interaction physics. This document describes concisely the
COHERENT physics motivations, sensitivity, and next plans for measurements at
the SNS to be accomplished on a few-year timescale.
-
The coherent elastic scattering of neutrinos off nuclei has eluded detection
for four decades, even though its predicted cross-section is the largest by far
of all low-energy neutrino couplings. This mode of interaction provides new
opportunities to study neutrino properties, and leads to a miniaturization of
detector size, with potential technological applications. We observe this
process at a 6.7-sigma confidence level, using a low-background, 14.6-kg
CsI[Na] scintillator exposed to the neutrino emissions from the Spallation
Neutron Source (SNS) at Oak Ridge National Laboratory. Characteristic
signatures in energy and time, predicted by the Standard Model for this
process, are observed in high signal-to-background conditions. Improved
constraints on non-standard neutrino interactions with quarks are derived from
this initial dataset.
-
The COHERENT collaboration's primary objective is to measure coherent elastic
neutrino-nucleus scattering (CEvNS) using the unique, high-quality source of
tens-of-MeV neutrinos provided by the Spallation Neutron Source (SNS) at Oak
Ridge National Laboratory (ORNL). In spite of its large cross section, the
CEvNS process has never been observed, due to tiny energies of the resulting
nuclear recoils which are out of reach for standard neutrino detectors. The
measurement of CEvNS has now become feasible, thanks to the development of
ultra-sensitive technology for rare decay and weakly-interacting massive
particle (dark matter) searches. The CEvNS cross section is cleanly predicted
in the standard model; hence its measurement provides a standard model test. It
is relevant for supernova physics and supernova-neutrino detection, and enables
validation of dark-matter detector background and detector-response models. In
the long term, precision measurement of CEvNS will address questions of nuclear
structure. COHERENT will deploy multiple detector technologies in a phased
approach: a 14-kg CsI[Na] scintillating crystal, 15 kg of p-type point-contact
germanium detectors, and 100 kg of liquid xenon in a two-phase time projection
chamber. Following an extensive background measurement campaign, a location in
the SNS basement has proven to be neutron-quiet and suitable for deployment of
the COHERENT detector suite. The simultaneous deployment of the three COHERENT
detector subsystems will test the $N^2$ dependence of the cross section and
ensure an unambiguous discovery of CEvNS. This document describes concisely the
COHERENT physics motivations, sensitivity and plans for measurements at the SNS
to be accomplished on a four-year timescale.