-
In this paper, we present the design and the expected performance of the
classical Lyot coronagraph for the high contrast imaging modes of the
wide-field imager MICADO. MICADO is a near-IR camera for the Extremely Large
Telescope (ELT, previously E-ELT), with wide-field, spectroscopic and
coronagraphic capabilities. MICADO is one of the first-light instruments
selected by the ESO. Optimized to work with a multi-conjugate adaptive optics
corrections provided by the MOARY module, it will also come with a SCAO
correction with a high-level, on-axis correction, making use of the M4 adaptive
mirror of the telescope.
After presenting the context of the high contrast imaging modes in MICADO, we
describe the selection process for the focal plane masks and Lyot stop. We will
also show results obtained in realistic conditions, taking into account AO
residuals, atmospheric refraction, noise sources and simulating observations in
angular differential imaging (ADI) mode. Based on SPHERE on-sky results, we
will discuss the achievable gain in contrast and angular separation provided by
MICADO over the current instruments on 10-m class telescopes, in particular for
imaging young giant planets at very short separations around nearby stars as
well as planets on wider orbits around more distant stars in young stellar
associations.
-
A vortex coronagraph is now available for high contrast observations with the
Keck/NIRC2 instrument at L band. Reaching the optimal performance of the
coronagraph requires fine control of the wavefront incident on the phase mask.
In particular, centering errors can lead to significant stellar light leakage
that degrades the contrast performance and prevents the observation of faint
planetary companions around the observed stars. It is thus critical to correct
for the possible slow drift of the star image from the phase mask center,
generally due to mechanical flexures induced by temperature and/or gravity
field variation, or to misalignment between the optics that rotate in pupil
tracking mode. A control loop based on the QACITS algorithm for the vortex
coronagraph has thus been developed and deployed for the Keck/NIRC2 instrument.
This algorithm executes the entire observing sequence, including the
calibration steps, initial centering of the star on the vortex center and
stabilisation during the acquisition of science frames. On-sky data show that
the QACITS control loop stabilizes the position of the star image down to 2.4
mas rms at a frequency of about 0.02 Hz. However, the accuracy of the estimator
is probably limited by a systematic error due to a misalignment of the Lyot
stop with respect to the entrance pupil, estimated to be on the order of 4.5
mas. A method to reduce the amplitude of this bias down to 1 mas is proposed.
The QACITS control loop has been successfully implemented and provides a robust
method to center and stabilize the star image on the vortex mask. In addition,
QACITS ensures a repeatable pointing quality and significantly improves the
observing efficiency compared to manual operations. It is now routinely used
for vortex coronagraph observations at Keck/NIRC2, providing contrast and
angular resolution capabilities suited for exoplanet and disk imaging.
-
HD 141569 A is a pre-main sequence B9.5 Ve star surrounded by a prominent and
complex circumstellar disk, likely still in a transition stage from
protoplanetary to debris disk phase. Here, we present a new image of the third
inner disk component of HD 141569 A made in the L' band (3.8 micron) during the
commissioning of the vector vortex coronagraph recently installed in the
near-infrared imager and spectrograph NIRC2 behind the W.M. Keck Observatory
Keck II adaptive optics system. We used reference point spread function
subtraction, which reveals the innermost disk component from the inner working
distance of $\simeq 23$ AU and up to $\simeq 70$ AU. The spatial scale of our
detection roughly corresponds to the optical and near-infrared scattered light,
thermal Q, N and 8.6 micron PAH emission reported earlier. We also see an
outward progression in dust location from the L'-band to the H-band (VLT/SPHERE
image) to the visible (HST/STIS image), likely indicative of dust blowout. The
warm disk component is nested deep inside the two outer belts imaged by HST
NICMOS in 1999 (respectively at 406 and 245 AU). We fit our new L'-band image
and spectral energy distribution of HD 141569 A with the radiative transfer
code MCFOST. Our best-fit models favor pure olivine grains, and are consistent
with the composition of the outer belts. While our image shows a putative
very-faint point-like clump or source embedded in the inner disk, we did not
detect any true companion within the gap between the inner disk and the first
outer ring, at a sensitivity of a few Jupiter masses.
-
An optical vortex coronagraph has been implemented within the NIRC2 camera on
the Keck II telescope and used to carry out on-sky tests and observations. The
development of this new L'-band observational mode is described, and an initial
demonstration of the new capability is presented: a resolved image of the
low-mass companion to HIP79124, which had previously been detected by means of
interferometry. With HIP79124 B at a projected separation of 186.5 mas, both
the small inner working angle of the vortex coronagraph and the related imaging
improvements were crucial in imaging this close companion directly. Due to
higher Strehl ratios and more relaxed contrasts in L' band versus H band, this
new coronagraphic capability will enable high-contrast small-angle observations
of nearby young exoplanets and disks on a par with those of shorter-wavelength
extreme adaptive optics coronagraphs.
-
Uncovering the ingredients and the architecture of planetary systems is a
very active field of research that has fuelled many new theories on giant
planet formation, migration, composition, and interaction with the
circumstellar environment. We aim at discovering and studying new such systems,
to further expand our knowledge of how low-mass companions form and evolve. We
obtained high-contrast H-band images of the circumstellar environment of the
F5V star HD206893, known to host a debris disc never detected in scattered
light. These observations are part of the SPHERE High Angular Resolution Debris
Disc Survey (SHARDDS) using the InfraRed Dual-band Imager and Spectrograph
(IRDIS) installed on VLT/SPHERE. We report the detection of a source with a
contrast of 3.6x10^{-5} in the H-band, orbiting at a projected separation of
270 milliarcsecond or 10 au, corresponding to a mass in the range 24 to 73 Mjup
for an age of the system in the range 0.2 to 2 Gyr. The detection was confirmed
ten months later with VLT/NaCo, ruling out a background object with no proper
motion. A faint extended emission compatible with the disc scattered light
signal is also observed. The detection of a low-mass companion inside a massive
debris disc makes this system an analog of other young planetary systems such
as beta Pictoris, HR8799 or HD95086 and requires now further characterisation
of both components to understand their interactions.
-
Context. The Annular Groove Phase Mask (AGPM) is one possible implementation
of the vector vortex coronagraph, where the helical phase ramp is produced by a
concentric subwavelength grating. For several years, we have been manufacturing
AGPMs by etching gratings into synthetic diamond substrates using inductively
coupled plasma etching. Aims. We aim to design, fabricate, optimize, and
evaluate new L-band AGPMs that reach the highest possible coronagraphic
performance, for applications in current and forthcoming infrared high-contrast
imagers. Methods. Rigorous coupled wave analysis (RCWA) is used for designing
the subwavelength grating of the phase mask. Coronagraphic performance
evaluation is performed on a dedicated optical test bench. The experimental
results of the performance evaluation are then used to accurately determine the
actual profile of the fabricated gratings, based on RCWA modeling. Results. The
AGPM coronagraphic performance is very sensitive to small errors in etch depth
and grating profile. Most of the fabricated components therefore show moderate
performance in terms of starlight rejection (a few 100:1 in the best cases).
Here we present new processes for re-etching the fabricated components in order
to optimize the parameters of the grating and hence significantly increase
their coronagraphic performance. Starlight rejection up to 1000:1 is
demonstrated in a broadband L filter on the coronagraphic test bench, which
corresponds to a raw contrast of about 1e-5 at two resolution elements from the
star for a perfect input wave front on a circular, unobstructed aperture.
Conclusions. Thanks to their exquisite performance, our latest L-band AGPMs are
good candidates for installation in state-of-the-art and future high-contrast
thermal infrared imagers, such as METIS for the E-ELT.
-
Small inner working angle coronagraphs are essential to benefit from the full
potential of large and future extremely large ground-based telescopes,
especially in the context of the detection and characterization of exoplanets.
Among existing solutions, the vortex coronagraph stands as one of the most
effective and promising solutions. However, for focal-plane coronagraph, a
small inner working angle comes necessarily at the cost of a high sensitivity
to pointing errors. This is the reason why a pointing control system is
imperative to stabilize the star on the vortex center against pointing drifts
due to mechanical flexures, that generally occur during observation due for
instance to temperature and/or gravity variations. We have therefore developed
a technique called QACITS (Quadrant Analysis of Coronagraphic Images for
Tip-tilt Sensing), which is based on the analysis of the coronagraphic image
shape to infer the amount of pointing error. It has been shown that the flux
gradient in the image is directly related to the amount of tip-tilt affecting
the beam. The main advantage of this technique is that it does not require any
additional setup and can thus be easily implemented on all current facilities
equipped with a vortex phase mask. In this paper, we focus on the
implementation of the QACITS sensor at Keck/NIRC2, where an L-band AGPM has
been recently commissioned (June and October 2015), successfully validating the
QACITS estimator in the case of a centrally obstructed pupil. The algorithm has
been designed to be easily handled by any user observing in vortex mode, which
is available for science in shared risk mode since 2016B.
-
For several years, we have been developing vortex phase masks based on
sub-wavelength gratings, known as Annular Groove Phase Masks. Etched onto
diamond substrates, these AGPMs are currently designed to be used in the
thermal infrared (ranging from 3 to 13 {\mu}m). Our AGPMs were first installed
on VLT/NACO and VLT/VISIR in 2012, followed by LBT/LMIRCam in 2013 and
Keck/NIRC2 in 2015. In this paper, we review the development, commissioning,
on-sky performance, and early scientific results of these new coronagraphic
modes and report on the lessons learned. We conclude with perspectives for
future developments and applications.
-
In this paper, we present the infrared coronagraphic test bench of the
University of Li\`ege named VODCA (Vortex Optical Demonstrator for
Coronagraphic Applications). The goal of the bench is to assess the
performances of the Annular Groove Phase Masks (AGPMs) at near- to mid-infrared
wavelengths. The AGPM is a subwavelength grating vortex coronagraph of charge
two (SGVC2) made out of diamond. The bench is designed to be completely
achromatic and will be composed of a super continuum laser source emitting in
the near to mid-infrared, several parabolas, diaphragms and an infrared camera.
This way, we will be able to test the different AGPMs in the M, L, K and H
bands. Eventually, the bench will also allow the computation of the incident
wavefront aberrations on the coronagraph. A reflective Lyot stop will send most
of the stellar light to a second camera to perform low-order wavefront sensing.
This second system coupled with a deformable mirror will allow the correction
of the wavefront aberrations. We also aim to test other pre- and/or
post-coronagraphic concepts such as optimal apodization.
-
Small inner working angle coronagraphs, like the vortex phase mask, are
essential to exploit the full potential of ground-based telescopes in the
context of exoplanet detection and characterization. However, the drawback of
this attractive feature is a high sensitivity to pointing errors, which
degrades the performance of the coronagraph. We propose a tip-tilt retrieval
technique based on the analysis of the final coronagraphic image, hereafter
called Quadrant Analysis of Coronagraphic Images for Tip-tilt Sensing (QACITS).
Under the assumption of small phase aberrations, we show that the behaviour of
the vortex phase mask can be simply described from the entrance pupil to the
Lyot stop plane by Zernike polynomials. This convenient formalism is used to
establish the theoretical basis of the QACITS technique. Simulations have been
performed to demonstrate the validity and limits of the technique, including
the case of a centrally obstructed pupil. The QACITS technique principle is
further validated by experimental results in the case of an unobstructed
circular aperture. The typical configuration of the Keck telescope (24% central
obstruction) has been simulated with additional high order aberrations. In
these conditions, our simulations show that the QACITS technique is still
adapted to centrally obstructed pupils and performs tip-tilt retrieval with a
precision of $5 \times 10^{-2}$ {\lambda}/D when wavefront errors amount to
{\lambda}/14 rms and $10^{-2}$ {\lambda}/D for {\lambda}/70 rms errors (with
{\lambda} the wavelength and D the pupil diameter). The implementation of the
QACITS technique is based on the analysis of the scientific image and does not
require any modification of the original setup. Current facilities equipped
with a vortex phase mask can thus directly benefit from this technique to
improve the contrast performance close to the axis.
-
The vortex coronagraph is an optical instrument that precisely removes
on-axis starlight allowing for high contrast imaging at small angular
separation from the star, thereby providing a crucial capability for direct
detection and characterization of exoplanets and circumstellar disks.
Telescopes with aperture obstructions, such as secondary mirrors and spider
support structures, require advanced coronagraph designs to provide adequate
starlight suppression. We introduce a phase-only Lyot-plane optic to the vortex
coronagraph that offers improved contrast performance on telescopes with
complicated apertures. Potential solutions for the European Extremely Large
Telescope (E-ELT) are described and compared. Adding a Lyot-plane phase mask
relocates residual starlight away from a region of the image plane thereby
reducing stellar noise and improving sensitivity to off-axis companions. The
phase mask is calculated using an iterative phase retrieval algorithm.
Numerically, we achieve a contrast on the order of $10^{-6}$ for a companion
with angular displacement as small as $4~\lambda/D$ with an E-ELT type
aperture. Even in the presence of aberrations, improved performance is expected
compared to either a conventional vortex coronagraph or optimized pupil plane
phase element alone.
-
We present methods for optimizing pupil and focal plane optical elements that
improve the performance of vortex coronagraphs on telescopes with obstructed or
segmented apertures. Phase-only and complex masks are designed for the entrance
pupil, focal plane, and the plane of the Lyot stop. Optimal masks are obtained
using both analytical and numerical methods. The latter makes use of an
iterative error reduction algorithm to calculate "correcting" optics that
mitigate unwanted diffraction from aperture obstructions. We analyze the
achieved performance in terms of starlight suppression, contrast, off-axis
image quality, and chromatic dependence. Manufacturing considerations and
sensitivity to aberrations are also discussed. This work provides a path to
joint optimization of multiple coronagraph planes to maximize sensitivity to
exoplanets and other faint companions.
-
(abridged) Vortex coronagraphs are among the most promising solutions to
perform high contrast imaging at small angular separations. They feature a very
small inner working angle, a clear 360 degree discovery space, have
demonstrated very high contrast capabilities, are easy to implement on
high-contrast imaging instruments, and have already been extensively tested on
the sky. Since 2005, we have been designing, developing and testing an
implementation of the charge-2 vector vortex phase mask based on concentric
subwavelength gratings, referred to as the Annular Groove Phase Mask (AGPM).
Science-grade mid-infrared AGPMs were produced in 2012 for the first time,
using plasma etching on synthetic diamond substrates. They have been validated
on a coronagraphic test bench, showing broadband peak rejection up to 500:1 in
the L band, which translates into a raw contrast of about $6\times 10^{-5}$ at
$2 \lambda/D$. Three of them have now been installed on world-leading
diffraction-limited infrared cameras (VLT/NACO, VLT/VISIR and LBT/LMIRCam).
During the science verification observations with our L-band AGPM on NACO, we
observed the beta Pictoris system and obtained unprecedented sensitivity limits
to planetary companions down to the diffraction limit ($0.1''$). More recently,
we obtained new images of the HR 8799 system at L band during the AGPM first
light on LMIRCam. After reviewing these first results obtained with
mid-infrared AGPMs, we will discuss the short- and mid-term goals of the
on-going VORTEX project, which aims to improve the performance of our vortex
phase masks for future applications on second-generation high-contrast imagers
and on future extremely large telescopes (ELTs).
-
The Subaru Coronagraphic Extreme AO (SCExAO) instrument consists of a high
performance Phase Induced Amplitude Apodisation (PIAA) coronagraph combined
with an extreme Adaptive Optics (AO) system operating in the near-infrared (H
band). The extreme AO system driven by the 2000 element deformable mirror will
allow for Strehl ratios >90% to be achieved in the H-band when it goes closed
loop. This makes the SCExAO instrument a powerful platform for high contrast
imaging down to angular separations of the order of 1lambda/D and an ideal
testbed for exploring coronagraphic techniques for ELTs. In this paper we
report on the recent progress in regards to the development of the instrument,
which includes the addition of a visible bench that makes use of the light at
shorter wavelengths not currently utilized by SCExAO and closing the loop on
the tip/tilt wavefront sensor. We will also discuss several exciting guest
instruments which will expand the capabilities of SCExAO over the next few
years; namely CHARIS which is a integral field spectrograph as well as
VAMPIRES, a visible aperture masking experiment based on polarimetric analysis
of circumstellar disks. In addition we will elucidate the unique role extreme
AO systems will play in enabling high precision radial velocity spectroscopy
for the detection of small companions.