• Login
    Sort by: Relevance Date Users's collections Twitter
    Group by: Day Week Month Year All time
Based on the idea and the provided source code of Andrej Karpathy (arxiv-sanity)
2:3 1:1 3:2
  • Helium-Xenon mixtures to improve topological signature in high pressure gas Xenon TPCs (1710.05600)

    R. Felkai, F. Monrabal, D. Gonzalez-Díaz, M. Sorel, N. López-March, J.J. Gómez-Cadenas, C. Adams, V.Álvarez, L.Arazi, C.D.R.Azevedo, J.M.Benlloch-Rodríguez, F.I.G.M.Borges, A.Botas, S.Cárcel, J.V. Carrión, S. Cebrián, C.A.N. Conde, J. Díaz, M. Diesburg, J. Escada, R. Esteve, L.M.P. Fernandes, P. Ferrario, A.L. Ferreira, E.D.C. Freitas, A. Goldschmidt, R. Guenette, R.M. Gutiérrez, K. Hafidi, J. Hauptman, C.A.O. Henriques, A.I. Hernandez, J.A. Hernando Morata, V. Herrero, S. Johnston, B.J.P. Jones, L. Labarga, A. Laing, P. Lebrun, M. Losada, J. Martín-Albo, G. Martínez-Lema, A. Martínez, A.D. McDonald, C.M.B. Monteiro, F.J. Mora, L.M. Moutinho, J. Muñoz Vidal, M. Musti, M. Nebot-Guinot, P. Novella, D.R. Nygren, B. Palmeiro, A. Para, J. Pérez, M. Querol, J. Renner, J. Repond, S. Riordan, L. Ripoll, C. Romo, J. Rodríguez, L. Rogers, F.P. Santos, J.M.F. dos Santos, A. Simón, C. Sofka, T. Stiegler, J.F. Toledo, J. Torrent, Z. Tsamalaidze, J.F.C.A. Veloso, R. Webb, J.T. White, N. Yahlali
    Dec. 20, 2018 hep-ex, nucl-ex, physics.ins-det
    Within the framework of xenon-based double beta decay experiments, we propose the possibility to improve the background rejection of an electroluminescent Time Projection Chamber (EL TPC) by reducing the diffusion of the drifting electrons while keeping nearly intact the energy resolution of a pure xenon EL TPC. Based on state-of-the-art microscopic simulations, a substantial addition of helium, around 10 or 15~\%, may reduce drastically the transverse diffusion down to 2.5~mm/$\sqrt{\mathrm{m}}$ from the 10.5~mm/$\sqrt{\mathrm{m}}$ of pure xenon. The longitudinal diffusion remains around 4~mm/$\sqrt{\mathrm{m}}$. Light production studies have been performed as well. They show that the relative variation in energy resolution introduced by such a change does not exceed a few percent, which leaves the energy resolution practically unchanged. The technical caveats of using photomultipliers close to an helium atmosphere are also discussed in detail.
  • The Next White (NEW) detector (1804.02409)

    F. Monrabal, J.J. Gómez-Cadenas, J.F. Toledo, V. Álvarez, J.M. Benlloch-Rodríguez, S. Cárcel, J.V. Carrión, R. Esteve, R. Felkai, V. Herrero, A. Laing, A. Martínez, M. Musti, M. Querol, J. Rodríguez, A. Simón, C. Sofka, J. Torrent, R. Webb, J.T. White, C. Adams, L. Arazi, C.D.R. Azevedo, K. Bailey, F. Ballester, F.I.G.M. Borges, A. Botas, S. Cebrián, C.A.N. Conde, J. Díaz, M. Diesburg, J. Escada, L.M.P. Fernandes, P. Ferrario, A.L. Ferreira, E.D.C. Freitas, A. Goldschmidt, D. González-Díaz, R. Guenette, R.M. Gutiérrez, K. Hafidi, J. Hauptman, C.A.O. Henriques, A.I. Hernandez, J.A. Hernando Morata, S. Johnston, B.J.P. Jones, L. Labarga, P. Lebrun, N. López-March, M. Losada, J. Martín-Albo, G. Martínez-Lema, A.D. McDonald, C.M.B. Monteiro, F.J. Mora, J. Munoz Vidal, M. Nebot-Guinot, P. Novella, D.R. Nygren, B. Palmeiro, A. Para, J. Pérez, J. Renner, J. Repond, S. Riordan, C. Romo, L. Ripoll, L. Rogers, F.P. Santos, J.M.F. dos Santos, M. Sorel, T. Stiegler, J.F.C.A. Veloso, N. Yahlali
    April 6, 2018 physics.ins-det
    Conceived to host 5 kg of xenon at a pressure of 15 bar in the fiducial volume, the NEXT- White (NEW) apparatus is currently the largest high pressure xenon gas TPC using electroluminescent amplification in the world. It is also a 1:2 scale model of the NEXT-100 detector scheduled to start searching for $\beta\beta 0\nu$ decays in 136Xe in 2019. Both detectors measure the energy of the event using a plane of photomultipliers located behind a transparent cathode. They can also reconstruct the trajectories of charged tracks in the dense gas of the TPC with the help of a plane of silicon photomultipliers located behind the anode. A sophisticated gas system, common to both detectors, allows the high gas purity needed to guarantee a long electron lifetime. NEXT-White has been operating since October 2017 at the Canfranc Underground Laboratory (LSC), in Spain. This paper describes the detector and associated infrastructures.
  • Electron drift properties in high pressure gaseous xenon (1804.01680)

    NEXT Collaboration: A. Simón, R. Felkai, G. Martínez-Lema, F. Monrabal, D. González-Díaz, M. Sorel, J.A. Hernando Morata, J.J. Gómez-Cadenas, C. Adams, V. Álvarez, L. Arazi, C.D.R. Azevedo, J.M. Benlloch-Rodríguez, F.I.G.M. Borges, A. Botas, S. Cárcel, J.V. Carrión, S. Cebrián, C.A.N. Conde, J. Díaz, M. Diesburg, J. Escada, R. Esteve, L.M.P. Fernandes, P. Ferrario, A.L. Ferreira, E.D.C. Freitas, J. Generowicz, A. Goldschmidt, R. Guenette, R.M. Gutiérrez, K. Hafidi, J. Hauptman, C.A.O. Henriques, A.I. Hernandez, V. Herrero, S. Johnston, B.J.P. Jones, M.Kekic, L. Labarga, A. Laing, P. Lebrun, N. López-March, M. Losada, J. Martín-Albo, A. Martínez, A.D. McDonald, C.M.B. Monteiro, F.J. Mora, J. Muñoz Vidal, M. Musti, M. Nebot-Guinot, P. Novella, D.R. Nygren, B. Palmeiro, A. Para, J. Pérez, M. Querol, J. Renner, J. Repond, S. Riordan, L. Ripoll, J. Rodríguez, L. Rogers, C. Romo, F.P. Santos, J.M.F. dos Santos, C. Sofka, T. Stiegler, J.F. Toledo, J. Torrent, J.F.C.A. Veloso, R. Webb, J.T. White, N. Yahlali
    April 5, 2018 hep-ex, nucl-ex, physics.ins-det
    Gaseous time projection chambers (TPC) are a very attractive detector technology for particle tracking. Characterization of both drift velocity and diffusion is of great importance to correctly assess their tracking capabilities. NEXT-White is a High Pressure Xenon gas TPC with electroluminescent amplification, a 1:2 scale model of the future NEXT-100 detector, which will be dedicated to neutrinoless double beta decay searches. NEXT-White has been operating at Canfranc Underground Laboratory (LSC) since December 2016. The drift parameters have been measured using $^{83m}$Kr for a range of reduced drift fields at two different pressure regimes, namely 7.2 bar and 9.1 bar. The results have been compared with Magboltz simulations. Agreement at the 5% level or better has been found for drift velocity, longitudinal diffusion and transverse diffusion.
  • Calibration of the NEXT-White detector using $^{83m}\mathrm{Kr}$ decays (1804.01780)

    NEXT Collaboration: G. Martínez-Lema, J.A. Hernando Morata, B. Palmeiro, A. Botas, P. Ferrario, F. Monrabal, A. Laing, J. Renner, J.J. Gómez-Cadenas, C. Adams, V. Álvarez, L. Arazi, C.D.R. Azevedo, K. Bailey, J.M. Benlloch-Rodríguez, F.I.G.M. Borges, S. Cárcel, J.V. Carrión, S. Cebrián, C.A.N. Conde, J. Díaz, M. Diesburg, J. Escada, R. Esteve, R. Felkai, L.M.P. Fernandes, A.L. Ferreira, E.D.C. Freitas, J. Generowicz, A. Goldschmidt, D. González-Díaz, R. Guenette, R.M. Gutiérrez, K. Hafidi, J. Hauptman, C.A.O. Henriques, A.I. Hernandez, V. Herrero, S. Johnston, B.J.P. Jones, M.Kekic, L. Labarga, P. Lebrun, N. López-March, M. Losada, J. Martín-Albo, A. Martínez, A.D. McDonald, C.M.B. Monteiro, F.J. Mora, J. Muñoz Vidal, M. Musti, M. Nebot-Guinot, P. Novella, D.R. Nygren, A. Para, J. Pérez, M. Querol, J. Repond, S. Riordan, L. Ripoll, J. Rodríguez, L. Rogers, C. Romo, F.P. Santos, J.M.F. dos Santos, A. Simón, C. Sofka, M. Sorel, T. Stiegler, J.F. Toledo, J. Torrent, J.F.C.A. Veloso, R. Webb, J.T. White, N. Yahlalib
    April 5, 2018 hep-ex, physics.ins-det
    The NEXT-White (NEW) detector is currently the largest radio-pure high pressure gas xenon time projection chamber with electroluminescent readout in the world. NEXT-White has been operating at Laboratorio Subterr\'aneo de Canfranc (LSC) since October 2016. This paper describes the calibrations performed with $^{83m}\mathrm{Kr}$ decays during a long run taken from March to November 2017 (Run II). Krypton calibrations are used to correct for the finite drift-electron lifetime as well as for the dependence of the measured energy on the event position which is mainly caused by variations in solid angle coverage. After producing calibration maps to correct for both effects we measure an excellent energy resolution for 41.5 keV point-like deposits of (4.55 $\pm$ 0.01) % FWHM in the full chamber and (3.88 $\pm$ 0.04) % FWHM in a restricted fiducial volume. Using naive 1/$\sqrt{E}$ scaling, these values translate into FWHM resolutions of (0.592 $\pm$ 0.001) % FWHM and (0.504 $\pm$ 0.005) % at the $Q_{\beta\beta}$ energy of xenon double beta decay (2458 keV), well within range of our target value of 1%.
  • Measurement of radon-induced backgrounds in the NEXT double beta decay experiment (1804.00471)

    NEXT Collaboration: P. Novella, B. Palmeiro, A. Simón, M. Sorel, P. Ferrario, G. Martínez-Lema, F. Monrabal, G. Zuzel, J.J. Gómez-Cadenas, C. Adams, V. Álvarez, L. Arazi, C.D.R Azevedo, K. Bailey, J.M. Benlloch-Rodríguez, F.I.G.M. Borges, A. Botas, S. Cárcel, J.V. Carrión, S. Cebrián, C.A.N. Conde, J. Díaz, M. Diesburg, J.M.F. Dos Santos, J. Escada, R. Esteve, R. Felkai, L.M.P. Fernandes, A.L. Ferreira, E.D.C. Freitas, J. Generowicz, A. Goldschmidt, D. González-Díaz, R. Guenette, R.M. Gutiérrez, K. Hafidi, J. Hauptman, C.A.O. Henriques, A.I. Hernandez, J.A. Hernando Morata, V. Herrero, S. Johnston, B.J.P. Jones, M. Kekic, L. Labarga, A. Laing, P. Lebrun, N. López-March, M. Losada, J. Martín-Albo, A. Martínez, A. McDonald, C.M.B. Monteiro, F.J. Mora, J. Muñoz Vidal, M. Musti, M. Nebot-Guinot, D.R. Nygren, A. Para, J. Pérez, M. Querol, J. Renner, J. Repond, S. Riordan, L. Ripoll, J. Rodríguez, L. Rogers, C. Romo, F.P. Santos, C. Sofka, T. Stiegler, J.F. Toledo, J. Torrent, J.F.C.A. Veloso, R. Webb, J.T. White, N. Yahlali
    April 2, 2018 hep-ex, nucl-ex, physics.ins-det
    The measurement of the internal 222Rn activity in the NEXT-White detector during the so-called Run-II period with 136Xe-depleted xenon is discussed in detail, together with its implications for double beta decay searches in NEXT. The activity is measured through the alpha production rate induced in the fiducial volume by 222Rn and its alpha-emitting progeny. The specific activity is measured to be $(37.5\pm 2.3~\mathrm{(stat.)}\pm 5.9~\mathrm{(syst.)})$~mBq/m$^3$. Radon-induced electrons have also been characterized from the decay of the 214Bi daughter ions plating out on the cathode of the time projection chamber. From our studies, we conclude that radon-induced backgrounds are sufficiently low to enable a successful NEXT-100 physics program, as the projected rate contribution should not exceed 0.2~counts/yr in the neutrinoless double beta decay sample.
  • Demonstration of Single Barium Ion Sensitivity for Neutrinoless Double Beta Decay using Single Molecule Fluorescence Imaging (1711.04782)

    A.D.McDonald, B.J.P. Jones, D.R.Nygren, C. Adams, V.Alvarez, C.D.R. Azevedo, J.M. Benlloch-Rodrıguez, F.I.G.M. Borges, A. Botas, S. Carcel, J.V. Carrion, S. Cebrian, C.A.N. Conde, J. Dıaz, M. Diesburg, J. Escada, R. Esteve, R. Felkai, L.M.P. Fernandes, P. Ferrario, A.L. Ferreira, E.D.C. Freitas, A. Goldschmidt, J.J. Gomez-Cadenas, D. Gonzalez-Dıaz, R.M. Gutierrez, R. Guenette, K. Hafidi, J. Hauptman, C.A.O. Henriques, A.I. Hernandez, J.A. Hernando Morata, V. Herrero, S. Johnston, L. Labarga, A. Laing, P. Lebrun, I. Liubarsky, N. Lopez-March, M. Losada, J. Martın-Albo, G. Martınez-Lema, A. Martınez, F. Monrabal, C.M.B. Monteiro, F.J. Mora, L.M. Moutinho, J. Munoz Vidal, M. Musti, M. Nebot-Guinot, P. Novella, B. Palmeiro, A. Para, J. Perez, M. Querol, J. Repond, J. Renner, S. Riordan, L. Ripoll, J. Rodrıguez, L. Rogers, F.P. Santos, J.M.F. dos Santos, A. Simon, C. Sofka, M. Sorel, T. Stiegler, J.F. Toledo, J. Torrent, Z. Tsamalaidze, J.F.C.A. Veloso, R. Webb, J.T. White, N. Yahlali
    Feb. 6, 2018 hep-ex, nucl-ex, physics.ins-det
    A new method to tag the barium daughter in the double beta decay of $^{136}$Xe is reported. Using the technique of single molecule fluorescent imaging (SMFI), individual barium dication (Ba$^{++}$) resolution at a transparent scanning surface has been demonstrated. A single-step photo-bleach confirms the single ion interpretation. Individual ions are localized with super-resolution ($\sim$2~nm), and detected with a statistical significance of 12.9~$\sigma$ over backgrounds. This lays the foundation for a new and potentially background-free neutrinoless double beta decay technology, based on SMFI coupled to high pressure xenon gas time projection chambers.
  • Gaseous and dual-phase time projection chambers for imaging rare processes (1710.01018)

    D. Gonzalez-Diaz, F. Monrabal, S. Murphy
    Oct. 7, 2017 physics.ins-det
    Modern approaches to the detection and imaging of rare particle interactions through gaseous and dual-phase time projection chambers are discussed. We introduce and examine their basic working principles and enabling technological assets.
  • Radiopurity assessment of the energy readout for the NEXT double beta decay experiment (1706.06012)

    S. Cebrián, J. Pérez, I. Bandac, L. Labarga, V. Álvarez, C.D.R. Azevedo, J.M. Benlloch-Rodríguez, F.I.G.M. Borges, A. Botas, S. Cárcel, J.V. Carrión, C.A.N. Conde, J. Díaz, M. Diesburg, J. Escada, R. Esteve, R. Felkai, L.M.P. Fernandes, P. Ferrario, A.L. Ferreira, E.D.C. Freitas, A. Goldschmidt, J.J. Gómez-Cadenas, D. González-Díaz, R.M. Gutiérrez, J. Hauptman, C.A.O. Henriques, A.I. Hernandez, J.A. Hernando Morata, V. Herrero, B.J.P. Jones, A. Laing, P. Lebrun, I. Liubarsky, N. López-March, M. Losada, J. Martín-Albo, G. Martínez-Lema, A. Martínez, A.D. McDonald, F. Monrabal, C.M.B. Monteiro, F.J. Mora, L.M. Moutinho, J. Muñoz Vidal, M. Musti, M. Nebot-Guinot, P. Novella, D.R. Nygren, B. Palmeiro, A. Para, M. Querol, J. Renner, L. Ripoll, o J. Rodríguez, L. Rogers, F.P. Santos, J.M.F. dos Santos, A. Simón, C. Sofka, M. Sorel, T. Stiegler, p J.F. Toledo, J. Torrent, Z. Tsamalaidze, J.F.C.A. Veloso, J.A. Villar, R. Webb, J.T. White, N. Yahlali
    Aug. 21, 2017 hep-ex, nucl-ex, physics.ins-det
    ... ... ... ... ... ...
    The Neutrino Experiment with a Xenon Time-Projection Chamber (NEXT) experiment intends to investigate the neutrinoless double beta decay of 136Xe, and therefore requires a severe suppression of potential backgrounds. An extensive material screening and selection process was undertaken to quantify the radioactivity of the materials used in the experiment. Separate energy and tracking readout planes using different sensors allow us to combine the measurement of the topological signature of the event for background discrimination with the energy resolution optimization. The design of radiopure readout planes, in direct contact with the gas detector medium, was especially challenging since the required components typically have activities too large for experiments demanding ultra-low background conditions. After studying the tracking plane, here the radiopurity control of the energy plane is presented, mainly based on gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterr\'aneo de Canfranc (Spain). All the available units of the selected model of photomultiplier have been screened together with most of the components for the bases, enclosures and windows. According to these results for the activity of the relevant radioisotopes, the selected components of the energy plane would give a contribution to the overall background level in the region of interest of at most 2.4 x 10-4 counts keV-1 kg-1 y-1, satisfying the sensitivity requirements of the NEXT experiment.
  • Microscopic simulation of xenon-based optical TPCs in the presence of molecular additives (1705.09481)

    C.D.R. Azevedo, D. Gonzalez-Diaz, S. F. Biagi, C.A.B. Oliveira, C.A.O. Henriques, J. Escada, F. Monrabal, J.J. Gómez-Cadenas, V. Álvarez, J. M. Benlloch-Rodríguez F.I.G.M. Borges, A. Botas, S. Cárcel, J. V. Carrión, S. Cebrián, C.A.N. Conde, J. Díaz, M. Diesburg, R. Esteve, R. Felkai, L.M.P. Fernandes, P. Ferrario, A.L. Ferreira, E.D.C. Freitas, A. Goldschmidt, R.M. Gutiérrez, J. Hauptman, A. I. Hernandez, J.A. Hernando Morata, V. Herrero, B.J.P. Jones, L. Labarga, A. Laing, P. Lebrun, I. Liubarsky, N. Lopez-March, M. Losada, J. Martín-Albo, A. Martínez, A. D. McDonald, C.M.B. Monteiro, F.J. Mora, L.M. Moutinho, J. Muñoz Vidal, M. Musti, M. Nebot-Guinot, P. Novella, D. Nygren, B. Palmeiro, A. Para, J. Pérez, M. Querol, J. Renner, L. Ripoll, J. Rodríguez, L. Rogers, F.P. Santos, J.M.F. dos Santos, L. Serra, D. Shuman, A. Simón, C. Sofka, M. Sorel, T. Stiegler, J.F. Toledo, J. Torrent, Z. Tsamalaidze, J.F.C.A. Veloso, R. Webb, J.T. White, N. Yahlali
    July 1, 2017 physics.ins-det
    ... ... ... ... ... ...
    We introduce a simulation framework for the transport of high and low energy electrons in xenon-based gaseous optical time projection chambers (OTPCs). The simulation relies on elementary cross sections (electron-atom and electron-molecule) and incorporates, in order to compute the gas scintillation, the reaction/quenching rates (atom-atom and atom-molecule) of the first 41 excited states of xenon and the relevant associated excimers, together with their radiative cascade. The results compare positively with observations made in pure xenon and its mixtures with CO$_2$ and CF$_4$ in a range of pressures from 0.1 to 10~bar. This work sheds some light on the elementary processes responsible for the primary and secondary xenon-scintillation mechanisms in the presence of additives, that are of interest to the OTPC technology.
  • Application and performance of an ML-EM algorithm in NEXT (1705.10270)

    NEXT Collaboration: A. Simón, C. Lerche, F. Monrabal, J.J. Gómez-Cadenas, V. Álvarez, C.D.R. Azevedo, J.M. Benlloch-Rodríguez, F.I.G.M. Borges, A. Botas, S. Cárcel, J.V. Carrión, S. Cebrián, C.A.N. Conde, J. Díaz, M. Diesburg, J. Escada, R. Esteve, R. Felkai, L.M.P. Fernandes, P. Ferrario, A.L. Ferreira, E.D.C. Freitas, A. Goldschmidt, D. González-Díaz, R.M. Gutiérrez, J. Hauptman, C.A.O. Henriques, A.I. Hernandez, J.A. Hernando Morata, V. Herrero, B.J.P. Jones, L. Labarga, A. Laing, P. Lebrun, I. Liubarsky, N. López-March, M. Losada, J. Martín-Albo, G. Martínez-Lema, A. Martínez, A.D. McDonald, C.M.B. Monteiro, F.J. Mora, L.M. Moutinho, J. Muñoz Vidal, M. Musti, M. Nebot-Guinot, P. Novella, D.R. Nygren, B. Palmeiro, A. Para, J. Pérez, M. Querol, J. Renner, L. Ripoll, J. Rodríguez, L. Rogers, F.P. Santos, J.M.F. dos Santos, C. Sofka, M. Sorel, T. Stiegler, J.F. Toledo, J. Torrent, Z. Tsamalaidze, J.F.C.A. Veloso, R. Webb, J.T. White, N. Yahlali
    May 29, 2017 hep-ex, physics.ins-det
    ... ... ... ... ... ...
    The goal of the NEXT experiment is the observation of neutrinoless double beta decay in $^{136}$Xe using a gaseous xenon TPC with electroluminescent amplification and specialized photodetector arrays for calorimetry and tracking. The NEXT Collaboration is exploring a number of reconstruction algorithms to exploit the full potential of the detector. This paper describes one of them: the Maximum Likelihood Expectation Maximization (ML-EM) method, a generic iterative algorithm to find maximum-likelihood estimates of parameters that has been applied to solve many different types of complex inverse problems. In particular, we discuss a bi-dimensional version of the method in which the photosensor signals integrated over time are used to reconstruct a transverse projection of the event. First results show that, when applied to detector simulation data, the algorithm achieves nearly optimal energy resolution (better than 0.5% FWHM at the Q value of $^{136}$Xe) for events distributed over the full active volume of the TPC.
  • Secondary scintillation yield of Xenon with sub-percent levels of CO2 additive: efficiently reducing electron diffusion in HPXe optical TPCs for rare-event detection (1704.01623)

    C.A.O. Henriques, E.D.C. Freitas, C.D.R. Azevedo, D. González-Díaz, R.D.P. Mano, M.R. Jorge, L.M.P. Fernandes, C.M.B. Monteiro, J.J. Gómez-Cadenas, V. Álvarez, J.M. Benlloch-Rodríguez, F.I.G.M. Borges, A. Botas, S. Cárcel, J.V. Carrión, S. Cebrián, C.A.N. Conde, J. Díaz, M. Diesburg, J. Escada, R. Esteve, R. Felkai, P. Ferrario, A.L. Ferreira, A. Goldschmidt, R.M. Gutiérrez, J. Hauptman, A.I. Hernandez, J.A. Hernando Morata, V. Herrero, B.J.P. Jones, L. Labarga, A. Laing, P. Lebrun, I. Liubarsky, N. López-March, M. Losada, J. Martín-Albo, G. Martínez-Lema, A. Martínez, A.D. McDonald, F. Monrabal, F.J. Mora, L.M. Moutinho, J. Muñoz Vidal, M. Musti, M. Nebot-Guinot, P. Novella, D.R. Nygren, B. Palmeiro, A. Para, J. Pérez, M. Querol, J. Renner, L. Ripoll, J. Rodríguez, L. Rogers, F.P. Santos, J.M.F. dos Santos, A. Simón, C. Sofka, M. Sorel, T. Stiegler, J.F. Toledo, J. Torrent, Z. Tsamalaidze, J.F.C.A. Veloso, R. Webb, J.T. White, N. Yahlali
    April 13, 2017 physics.ins-det
    We have measured the electroluminescence (EL) yield of Xe-CO2 mixtures, with sub-percent CO2 concentrations. We demonstrate that the EL production is still high in these mixtures, 70% and 35% relative to that produced in pure xenon, for CO2 concentrations around 0.05% and 0.1%, respectively. The contribution of the statistical fluctuations in EL production to the energy resolution increases with increasing CO2 concentration and, for our gas proportional scintillation counter, it is smaller than the contribution of the Fano factor for concentrations below 0.1% CO2. Xe-CO2 mixtures are important alternatives to pure xenon in TPCs based on EL signal amplification with applications in the important field of rare event detection such as directional dark matter, double electron capture and double beta decay detection. The addition of CO2 to pure xenon at the level of 0.05-0.1% can reduce significantly the scale of electron diffusion from 10 mm/sqrt(m) to 2.5 mm/sqrt(m), with high impact on the HPXe TPC discrimination efficiency of the events through pattern recognition of the topology of primary ionisation trails.
  • Background rejection in NEXT using deep neural networks (1609.06202)

    NEXT Collaboration: J. Renner, A. Farbin, J. Muñoz Vidal, J.M. Benlloch-Rodríguez, A. Botas, P. Ferrario, J.J. Gómez-Cadenas, V. Álvarez, C.D.R. Azevedo, F.I.G. Borges, S. Cárcel, J.V. Carrión, S. Cebrián, A. Cervera, C.A.N. Conde, J. Díaz, M. Diesburg, R. Esteve, L.M.P. Fernandes, A.L. Ferreira, E.D.C. Freitas, A. Goldschmidt, D. González-Díaz, R.M. Gutiérrez, J. Hauptman, C.A.O. Henriques, J.A. Hernando Morata, V. Herrero, B. Jones, L. Labarga, A. Laing, P. Lebrun, I. Liubarsky, N. López-March, D. Lorca, M. Losada, J. Martín-Albo, G. Martínez-Lema, A. Martínez, F. Monrabal, C.M.B. Monteiro, F.J. Mora, L.M. Moutinho, M. Nebot-Guinot, P. Novella, D. Nygren, A. Para, J. Pérez, M. Querol, L. Ripoll, J. Rodríguez, F.P. Santos, J.M.F. dos Santos, L. Serra, D. Shuman, A. Simón, C. Sofka, M. Sorel, J.F. Toledo, J. Torrent, Z. Tsamalaidze, J.F.C.A. Veloso, J. White, R. Webb, N. Yahlali, H. Yepes-Ramírez
    Oct. 18, 2016 hep-ex, physics.ins-det
    ... ... ... ... ... ...
    We investigate the potential of using deep learning techniques to reject background events in searches for neutrinoless double beta decay with high pressure xenon time projection chambers capable of detailed track reconstruction. The differences in the topological signatures of background and signal events can be learned by deep neural networks via training over many thousands of events. These networks can then be used to classify further events as signal or background, providing an additional background rejection factor at an acceptable loss of efficiency. The networks trained in this study performed better than previous methods developed based on the use of the same topological signatures by a factor of 1.2 to 1.6, and there is potential for further improvement.
  • Investigation of the Coincidence Resolving Time performance of a PET scanner based on liquid xenon: A Monte Carlo study (1604.04106)

    J.J Gomez-Cadenas, J.M. Benlloch-Rodríguez, P. Ferrario, F. Monrabal, J. Rodríguez, J.F. Toledo
    Sept. 17, 2016 hep-ex, physics.ins-det
    ... ... ... ... ... ...
    The measurement of the time of flight of the two 511 keV gammas recorded in coincidence in a PET scanner provides an effective way of reducing the random background and therefore increases the scanner sensitivity, provided that the coincidence resolving time (CRT) of the gammas is sufficiently good. The best commercial PET-TOF system today (based in LYSO crystals and digital SiPMs), is the VEREOS of Philips, boasting a CRT of 316 ps (FWHM). In this paper we present a Monte Carlo investigation of the CRT performance of a PET scanner exploiting the scintillating properties of liquid xenon. We find that an excellent CRT of 70 ps (depending on the PDE of the sensor) can be obtained if the scanner is instrumented with silicon photomultipliers (SiPMs) sensitive to the ultraviolet light emitted by xenon. Alternatively, a CRT of 160 ps can be obtained instrumenting the scanner with (much cheaper) blue-sensitive SiPMs coated with a suitable wavelength shifter. These results show the excellent time of flight capabilities of a PET device based in liquid xenon.
  • Sensitivity of NEXT-100 to neutrinoless double beta decay (1511.09246)

    NEXT Collaboration: J. Martín-Albo, J. Muñoz Vidal, P. Ferrario, M. Nebot-Guinot, J.J. Gómez-Cadenas, V. Álvarez, C.D.R. Azevedo, F.I.G. Borges, S. Cárcel, S. Cebrián, A. Cervera, C.A.N. Conde, J. Díaz, M. Diesburg, R. Esteve, L.M.P. Fernandes, A.L. Ferreira, E.D.C. Freitas, A. Goldschmidt, D. González-Díaz, R.M. Gutiérrez, J. Hauptman, C.A.O. Henriques, J.A. Hernando Morata, L. Labarga, A. Laing, P. Lebrun, I. Liubarsky, N. López-March, D. Lorca, M. Losada, G. Martínez-Lema, A. Martínez, F. Monrabal, C.M.B. Monteiro, F.J. Mora, L.M. Moutinho, P. Novella, D. Nygren, B. Palmeiro, A. Para, J. Pérez, M. Querol, J. Renner, L. Ripoll, J. Rodríguez, F.P. Santos, J.M.F. dos Santos, L. Serra, D. Shuman, A. Simón, C. Sofka, M. Sorel, T. Stiegler, J.F. Toledo, J. Torrent, Z. Tsamalaidze, J.F.C.A. Veloso, R. Webb, J.T. White, N. Yahlali, H. Yepes-Ramírez
    May 31, 2016 hep-ex, nucl-ex, physics.ins-det
    ... ... ... ... ... ...
    NEXT-100 is an electroluminescent high-pressure xenon gas time projection chamber that will search for the neutrinoless double beta ($\beta \beta 0 \nu$) decay of Xe-136. The detector possesses two features of great value for $\beta \beta 0 \nu$ searches: energy resolution better than 1\% FWHM at the $Q$ value of Xe-136 and track reconstruction for the discrimination of signal and background events. This combination results in excellent sensitivity, as discussed in this paper. Material-screening measurements and a detailed Monte Carlo detector simulation predict a background rate for NEXT-100 of at most $4\times10^{-4}$ counts keV$^{-1}$ kg$^{-1}$ yr$^{-1}$. Accordingly, the detector will reach a sensitivity to the \bbonu-decay half-life of $2.8\times10^{25}$ years (90\% CL) for an exposure of 100 $\mathrm{kg}\cdot\mathrm{year}$, or $6.0\times10^{25}$ years after a run of 3 effective years.
  • First proof of topological signature in the high pressure xenon gas TPC with electroluminescence amplification for the NEXT experiment (1507.05902)

    NEXT Collaboration: P. Ferrario, A. Laing, N. López-March, J.J. Gómez-Cadenas, V. Álvarez, C.D.R. Azevedo, F.I.G. Borges, S. Cárcel, S. Cebrián, A. Cervera, C.A.N. Conde, T. Dafni, J. Díaz, M. Diesburg, R. Esteve, L.M.P. Fernandes, A.L. Ferreira, E.D.C. Freitas, V.M. Gehman, A. Goldschmidt, D. González-Díaz, R.M. Gutiérrez, J. Hauptman, C.A.O. Henriques, J.A. Hernando Morata, I.G. Irastorza, L. Labarga, P. Lebrun, I. Liubarsky, D. Lorca, M. Losada, G. Luzón, A. Marí, J. Martín-Albo, G. Martínez-Lema, A. Martínez, T. Miller, F. Monrabal, M. Monserrate, C.M.B. Monteiro, F.J. Mora, L.M. Moutinho, J. Muñoz Vidal, M. Nebot-Guinot, P. Novella, D. Nygren, A. Para, J. Pérez, J.L. Pérez Aparicio, M. Querol, J. Renner, L. Ripoll, J. Rodríguez, F.P. Santos, J.M.F. dos Santos, L. Serra, D. Shuman, A. Simón, C. Sofka, M. Sorel, J.F. Toledo, J. Torrent, Z. Tsamalaidze, J.F.C.A. Veloso, J.A. Villar, R. Webb, J.T. White, N. Yahlali, H. Yepes-Ramírez
    Jan. 18, 2016 hep-ex, physics.ins-det
    ... ... ... ... ... ...
    The NEXT experiment aims to observe the neutrinoless double beta decay of xenon in a high-pressure Xe136 gas TPC using electroluminescence (EL) to amplify the signal from ionization. One of the main advantages of this technology is the possibility to reconstruct the topology of events with energies close to Qbb. This paper presents the first demonstration that the topology provides extra handles to reject background events using data obtained with the NEXT-DEMO prototype. Single electrons resulting from the interactions of Na22 1275 keV gammas and electron-positron pairs produced by conversions of gammas from the Th228 decay chain were used to represent the background and the signal in a double beta decay. These data were used to develop algorithms for the reconstruction of tracks and the identification of the energy deposited at the end-points, providing an extra background rejection factor of 24.3 +- 1.4 (stat.)%, while maintaining an efficiency of 66.7 +- 1% for signal events.
  • An homeopathic cure to pure Xenon large diffusion (1511.07189)

    C. D. R. Azevedo, L.M.P. Fernandes, E. D. C. Freitas, D. Gonzalez-Diaz, F. Monrabal, C. M. B. Monteiro, J. M. F. Dos Santos, J.F.C.A. Veloso, J. J Gomez-Cadenas
    Nov. 23, 2015 hep-ex, nucl-ex, physics.ins-det
    ... ... ... ... ... ...
    The NEXT neutrinoless double beta decay experiment will use a high- pressure gas electroluminescence-based TPC to search for the decay of Xe-136. One of the main advantages of this technology is the possibility to reconstruct the topology of events with energies close to Qbb. The rejection potential associated to the topology reconstruction is limited by our capacity to prop- erly reconstruct the original path of the electrons in the gas. This reconstruction is limited by different factors that include the geometry of the detector, the density of the sensors in the tracking plane and the separation among them, etc. Ultimately, the resolution is limited by the physics of electron diffusion in the gas. In this paper we present a series of molecular additives that can be used in Xenon gas at very low partial pressure to reduce both longitudinal and transverse diffusion. We will show the results of different Monte-Carlo simulations of electron transport in the gas mixtures from wich we have extracted the value of some important parameters like diffusion, drift velocity and light yields. These results show that there is a series of candidates that can reduce diffusion without affecting the energy resolution of the detector and they should be studied experimentally. A comparison with preliminary results from such an ongoing experimental effort is given.
  • Improved background rejection in neutrinoless double beta decay experiments using a magnetic field in a high pressure xenon TPC (1509.01821)

    J. Renner, A. Cervera, J.A. Hernando, A. Imzaylov, F. Monrabal, J. Muñoz, D. Nygren, J.J. Gomez-Cadenas
    Sept. 6, 2015 hep-ex, nucl-ex, physics.ins-det
    ... ... ... ... ... ...
    We demonstrate that the application of an external magnetic field could lead to an improved background rejection in neutrinoless double-beta (0nbb) decay experiments using a high pressure xenon (HPXe) TPC. HPXe chambers are capable of imaging electron tracks, a feature that enhances the separation between signal events (the two electrons emitted in the 0nbb decay of 136Xe) and background events, arising chiefly from single electrons of kinetic energy compatible with the end-point of the 0nbb decay (Qbb ). Applying an external magnetic field of sufficiently high intensity (in the range of 0.5-1 Tesla for operating pressures in the range of 5-15 atmospheres) causes the electrons to produce helical tracks. Assuming the tracks can be properly reconstructed, the sign (direction) of curvature can be determined at several points along these tracks, and such information can be used to separate signal (0nbb) events containing two electrons producing a track with two different directions of curvature from background (single-electron) events producing a track that should spiral in a single direction. Due to electron multiple scattering, this strategy is not perfectly efficient on an event-by-event basis, but a statistical estimator can be constructed which can be used to reject background events by one order of magnitude at a moderate cost (approx. 30%) in signal efficiency. Combining this estimator with the excellent energy resolution and topological signature identification characteristic of the HPXe TPC, it is possible to reach a background rate of less than one count per ton-year of exposure. Such a low background rate is an essential feature of the next generation of 0nbb experiments, aiming to fully explore the inverse hierarchy of neutrino masses.
  • Accurate gamma and MeV-electron track reconstruction with an ultra-low diffusion Xenon/TMA TPC at 10 atmospheres (1504.03678)

    Diego Gonzalez-Diaz, V. Alvarez, F.I.G. Borges, M. Camargo, S. Carcel, S. Cebrian, A. Cervera, C.A.N. Conde, T. Dafni, J. Diaz, R. Esteve, L.M.P. Fernandes, P. Ferrario, A.L. Ferreira, E.D.C. Freitas, V.M. Gehman, A. Goldschmidt, J.J. Gomez-Cadenas, R.M. Gutierrez, J. Hauptman, J.A. Hernando Morata, D.C. Herrera, I.G. Irastorza, L. Labarga, A. Laing, I. Liubarsky, N. Lopez-March, D. Lorca, M. Losada, G. Luzon, A. Mari, J. Martin-Albo, G. Martinez-Lema, A. Martinez, T. Miller, F. Monrabal, M. Monserrate, C.M.B. Monteiro, F.J. Mora, L.M. Moutinho, J. Munoz Vidal, M. Nebot-Guinot, D. Nygren, C.A.B. Oliveira, J. Perez, J.L. Perez Aparicio, M. Querol, J. Renner, L. Ripoll, J. Rodriguez, F.P. Santos, J.M.F. dos Santos, L. Serra, D. Shuman, A. Simon, C. Sofka, M. Sorel, J.F. Toledo, J. Torrent, Z. Tsamalaidze, J.F.C.A. Veloso, J.A. Villar, R.Webb, J.T. White, N. Yahlali, C. Azevedo, F. Aznar, D. Calvet, J. Castel, E. Ferrer-Ribas, J. A. Garcia, I. Giomataris, H. Gomez, F. J. Iguaz, A. Lagraba, A. Le Coguie, J.P. Mols,  O. Sahin, A. Rodriguez, E. Ruiz-Choliz, L. Segui, A. Tomas, R. Veenhof
    June 17, 2015 physics.ins-det
    ... ... ... ... ... ...
    We report the performance of a 10 atm Xenon/trimethylamine time projection chamber (TPC) for the detection of X-rays (30 keV) and gamma-rays (0.511-1.275 MeV) in conjunction with the accurate tracking of the associated electrons. When operated at such a high pressure and in 1%-admixtures, trimethylamine (TMA) endows Xenon with an extremely low electron diffusion (1.3 +-0.13 mm-sigma (longitudinal), 0.8 +-0.15 mm-sigma (transverse) along 1 m drift) besides forming a convenient Penning-Fluorescent mixture. The TPC, that houses 1.1 kg of gas in its active volume, operated continuously for 100 live-days in charge amplification mode. The readout was performed through the recently introduced microbulk Micromegas technology and the AFTER chip, providing a 3D voxelization of 8mm x 8mm x 1.2mm for approximately 10 cm/MeV-long electron tracks. This work was developed as part of the R&D program of the NEXT collaboration for future detector upgrades in the search of the 0bbnu decay in 136Xe, specifically those based on novel gas mixtures. Therefore we ultimately focus on the calorimetric and topological properties of the reconstructed MeV-electron tracks.
  • Radiopurity assessment of the tracking readout for the NEXT double beta decay experiment (1411.1433)

    S. Cebrián, J. Pérez, I. Bandac, L. Labarga, V. Álvarez, A.I. Barrado, A. Bettini, F.I.G.M. Borges, M. Camargo, S. Cárcel, A. Cervera, C.A.N. Conde, E. Conde, T. Dafni, J. Díaz, R. Esteve, L.M.P. Fernandes, M. Fernández, P. Ferrario, A.L. Ferreira, E.D.C. Freitas, V.M. Gehman, A. Goldschmidt, J.J. Gómez-Cadenas, D. González-Díaz, R.M. Gutiérrez, J. Hauptman, J.A. Hernando Morata, D.C. Herrera, I.G. Irastorza, A. Laing, I. Liubarsky, N. López-March, D. Lorca, M. Losada, G. Luzón, A. Marí, J. Martín-Albo, A. Martínez, G. Martínez-Lema, T. Miller, F. Monrabal, M. Monserrate, C.M.B. Monteiro, F.J. Mora, L.M. Moutinho, J. Muñoz Vidal, M. Nebot-Guinot, D. Nygren, C.A.B. Oliveira, A. Ortiz de Solórzano, J.L. Pérez Aparicio, M. Querol, J. Renner, L. Ripoll, J. Rodríguez, F.P. Santos, J.M.F. dos Santos, L. Serra, D. Shuman, A. Simón, C. Sofka, M. Sorel, J.F. Toledo, J. Torrent, Z. Tsamalaidze, J.F.C.A. Veloso, J.A. Villar, R.C. Webb, J.T. White, N. Yahlali
    June 15, 2015 hep-ex, nucl-ex, physics.ins-det
    ... ... ... ... ... ...
    The Neutrino Experiment with a Xenon Time-Projection Chamber (NEXT) is intended to investigate the neutrinoless double beta decay of 136Xe, which requires a severe suppression of potential backgrounds; therefore, an extensive screening and selection process is underway to control the radiopurity levels of the materials to be used in the experimental set-up of NEXT. The detector design combines the measurement of the topological signature of the event for background discrimination with the energy resolution optimization. Separate energy and tracking readout planes are based on different sensors: photomultiplier tubes for calorimetry and silicon multi-pixel photon counters for tracking. The design of a radiopure tracking plane, in direct contact with the gas detector medium, was specially challenging since the needed components like printed circuit boards, connectors, sensors or capacitors have typically, according to available information in databases and in the literature, activities too large for experiments requiring ultra-low background conditions. Here, the radiopurity assessment of tracking readout components based on gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterraneo de Canfranc (Spain) is described. According to the obtained results, radiopure enough printed circuit boards made of kapton and copper, silicon photomultipliers and other required components, fulfilling the requirement of an overall background level in the region of interest of at most 8 10-4 counts keV-1 kg-1 y-1, have been identified.
  • Radon and material radiopurity assessment for the NEXT double beta decay experiment (1505.07052)

    S. Cebrián, J. Pérez, I. Bandac, L. Labarga, V. Álvarez, A.I. Barrado, A. Bettini, F.I.G.M. Borges, M. Camargo, S. Cárcel, A. Cervera, C.A.N. Conde, E. Conde, T. Dafni, J. Díaz, R. Esteve, L.M.P. Fernandes, M. Fernández, P. Ferrario, E.D.C. Freitas, L.M.P. Fernandes, V.M. Gehman, A. Goldschmidt, J.J. Gómez-Cadenas, D. González-Díaz, R.M. Gutiérrez, J. Hauptman, J.A. Hernando Morata, D.C. Herrera, I.G. Irastorza, A. Laing, I. Liubarsky, N. López-March, D. Lorca, M. Losada, G. Luzón, A. Marí, J. Martín-Albo, A. Martínez, G. Martínez-Lema, T. Miller, F. Monrabal, M. Monserrate, C.M.B. Monteiro, F.J. Mora, L.M. Moutinho, J. Muñoz Vidal, M. Nebot-Guinot, D. Nygren, C.A.B. Oliveira, A. Ortiz de Solórzano, J.L. Pérez Aparicio, M. Querol, J. Renner, L. Ripoll, J. Rodríguez, F.P. Santos, J.M.F. dos Santos, L. Serra, D. Shuman, A. Simón, C. Sofka, M. Sorel, J.F. Toledo, J. Torrent, Z. Tsamalaidze, J.F.C.A. Veloso, J.A. Villar, R.C.Webb, J.T. White, N. Yahlali
    May 26, 2015 hep-ex, nucl-ex, physics.ins-det
    The Neutrino Experiment with a Xenon TPC (NEXT), intended to investigate the neutrinoless double beta decay using a high-pressure xenon gas TPC filled with Xe enriched in 136Xe at the Canfranc Underground Laboratory in Spain, requires ultra-low background conditions demanding an exhaustive control of material radiopurity and environmental radon levels. An extensive material screening process is underway for several years based mainly on gamma-ray spectroscopy using ultra-low background germanium detectors in Canfranc but also on mass spectrometry techniques like GDMS and ICPMS. Components from shielding, pressure vessel, electroluminescence and high voltage elements and energy and tracking readout planes have been analyzed, helping in the final design of the experiment and in the construction of the background model. The latest measurements carried out will be presented and the implication on NEXT of their results will be discussed. The commissioning of the NEW detector, as a first step towards NEXT, has started in Canfranc; in-situ measurements of airborne radon levels were taken there to optimize the system for radon mitigation and will be shown too.
  • An improved measurement of electron-ion recombination in high-pressure xenon gas (1412.3573)

    NEXT Collaboration: L. Serra, M. Sorel, V. Álvarez, F.I.G. Borges, M. Camargo, S. Cárcel, S. Cebrián, A. Cervera, C.A.N. Conde, T. Dafni, J. Díaz, R. Esteve, L.M.P. Fernandes, P. Ferrario, A.L. Ferreira, E.D.C. Freitas, V.M. Gehman, A. Goldschmidt, J.J. Gómez-Cadenas, D. González-Díaz, R.M. Gutiérrez, J. Hauptman, J.A. Hernando Morata, D.C. Herrera, I.G. Irastorza, L. Labarga, A. Laing, I. Liubarsky, N. Lopez-March, D. Lorca, M. Losada, G. Luzón, A. Marí, J. Martín-Albo, G. Martínez-Lema, A. Martínez, T. Miller, F. Monrabal, M. Monserrate, C.M.B. Monteiro, F.J. Mora, L.M. Moutinho, J. Muñoz Vidal, M. Nebot-Guinot, D. Nygren, C.A.B. Oliveira, J. Pérez, J.L. Pérez Aparicio, M. Querol, J. Renner, L. Ripoll, A. Rodríguez, J. Rodríguez, F.P. Santos, J.M.F. dos Santos, D. Shuman, A. Simón, C. Sofka, J.F. Toledo, J. Torrent, Z. Tsamalaidze, J.F.C.A. Veloso, J.A. Villar, R. Webb, J.T. White, N. Yahlali
    Feb. 3, 2015 hep-ex, physics.ins-det
    ... ... ... ... ... ...
    We report on results obtained with the NEXT-DEMO prototype of the NEXT-100 high-pressure xenon gas time projection chamber (TPC), exposed to an alpha decay calibration source. Compared to our previous measurements with alpha particles, an upgraded detector and improved analysis techniques have been used. We measure event-by-event correlated fluctuations between ionization and scintillation due to electron-ion recombination in the gas, with correlation coeffcients between -0.80 and -0.56 depending on the drift field conditions. By combining the two signals, we obtain a 2.8 % FWHM energy resolution for 5.49 MeV alpha particles and a measurement of the optical gain of the electroluminescent TPC. The improved energy resolution also allows us to measure the specific activity of the radon in the gas due to natural impurities. Finally, we measure the average ratio of excited to ionized atoms produced in the xenon gas by alpha particles to be $0.561\pm 0.045$, translating into an average energy to produce a primary scintillation photon of $W_{\rm ex}=(39.2\pm 3.2)$ eV.
  • Results of the material screening program of the NEXT experiment (1411.1222)

    T. Dafni, V. Alvarez, I. Bandac, A. Bettini, F.I.G.M. Borges, M. Camargo, S. Carcel, S. Cebrian, A. Cervera, C.A.N. Conde, J. Diaz, R. Esteve, L.M.P. Fernandes, M. Fernandez, P. Ferrario, A.L. Ferreira, E.D.C. Freitas, V.M. Gehman, A. Goldschmidt, H. Gomez, J.J. Gomez-Cadenas, D. Gonzalez-Diaz, R.M. Gutierrez, J. Hauptman, J.A. Hernando Morata, D.C. Herrera, F.J. Iguaz, I.G. Irastorza, L. Labarga, A. Laing, I. Liubarsky, D. Lorca, M. Losada, G. Luzon, A. Mari, J. Martin-Albo, A. Martinez, G. Martinez-Lema, T. Miller, F. Monrabal, M. Monserrate, C.M.B. Monteiro, F.J. Mora, L.M. Moutinho, J. Munoz Vidal, M. Nebot-Guinot, D. Nygren, C.A.B. Oliveira, J. Perez, J.L. Perez Aparicio, J. Renner, L. Ripoll, A. Rodriguez, J. Rodriguez, F.P. Santos, J.M.F. dos Santos, L. Segui, L. Serra, D. Shuman, A. Simon, C. Sofka, M. Sorel, J.F. Toledo, J. Torrent, Z. Tsamalaidze, J.F.C.A. Veloso, J.A. Villar, R.C. Webb, J.T. White, N. Yahlali
    Nov. 5, 2014 hep-ex, nucl-ex, physics.ins-det
    ... ... ... ... ... ...
    The 'Neutrino Experiment with a Xenon TPC (NEXT)', intended to investigate neutrinoless double beta decay, requires extremely low background levels. An extensive material screening and selection process to assess the radioactivity of components is underway combining several techniques, including germanium gamma-ray spectrometry performed at the Canfranc Underground Laboratory; recent results of this material screening program are presented here.
  • Characterisation of NEXT-DEMO using xenon K$_{\alpha}$ X-rays (1407.3966)

    NEXT Collaboration: D. Lorca, J. Martín-Albo, A. Laing, P. Ferrario, J.J. Gómez-Cadenas, V. Álvarez, F.I.G. Borges, M. Camargo, S. Cárcel, S. Cebrián, A. Cervera, C.A.N. Conde, T. Dafni, J. Díaz, R. Esteve, L.M.P. Fernandes, A.L. Ferreira, E.D.C. Freitas, V.M. Gehman, A. Goldschmidt, H. Gómez, D. González-Díaz, R.M. Gutiérrez, J. Hauptman, J.A. Hernando Morata, D.C. Herrera, I.G. Irastorza, L. Labarga, I. Liubarsky, M. Losada, G. Luzón, A. Marí, G. Martínez-Lema, A. Martínez, T. Miller, F. Monrabal, M. Monserrate, C.M.B. Monteiro, F.J. Mora, L.M. Moutinho, J. Muñoz Vidal, M. Nebot-Guinot, D. Nygren, C.A.B. Oliveira, J. Pérez, J.L. Pérez Aparicio, J. Renner, L. Ripoll, A. Rodríguez, J. Rodríguez, F.P. Santos, J.M.F. dos Santos, L. Seguí, L. Serra, D. Shuman, A. Simón, C. Sofka, M. Sorel, J.F. Toledo, J. Torrent, Z. Tsamalaidze, J.F.C.A. Veloso, R. Webb, J.T. White, N. Yahlali
    Nov. 5, 2014 hep-ex, physics.ins-det
    ... ... ... ... ... ...
    The NEXT experiment aims to observe the neutrinoless double beta decay of $^{136}$Xe in a high pressure gas TPC using electroluminescence (EL) to amplify the signal from ionization. Understanding the response of the detector is imperative in achieving a consistent and well understood energy measurement. The abundance of xenon k-shell x-ray emission during data taking has been identified as a multitool for the characterisation of the fundamental parameters of the gas as well as the equalisation of the response of the detector. The NEXT-DEMO prototype is a ~1.5 kg volume TPC filled with natural xenon. It employs an array of 19 PMTs as an energy plane and of 256 SiPMs as a tracking plane with the TPC light tube and SiPM surfaces being coated with tetraphenyl butadiene (TPB) which acts as a wavelength shifter for the VUV scintillation light produced by xenon. This paper presents the measurement of the properties of the drift of electrons in the TPC, the effects of the EL production region, and the extraction of position dependent correction constants using K$_{\alpha}$ X-ray deposits. These constants were used to equalise the response of the detector to deposits left by gammas from $^{22}$Na.
  • Ionization and scintillation of nuclear recoils in gaseous xenon (1409.2853)

    J. Renner, V. M. Gehman, A. Goldschmidt, H. S. Matis, T. Miller, Y. Nakajima, D. Nygren, C. A. B. Oliveira, D. Shuman, V. Álvarez, F. I. G. Borges, S. Cárcel, J. Castel, S. Cebrián, A. Cervera, C. A. N. Conde, T. Dafni, T. H. V. T. Dias, J. Díaz, R. Esteve, P. Evtoukhovitch, L. M. P. Fernandes, P. Ferrario, A. L. Ferreira, E. D. C. Freitas, A. Gil, H. Gómez, J. J. Gómez-Cadenas, D. González-Díaz, R. M. Gutiérrez, J. Hauptman, J. A. Hernando Morata, D. C. Herrera, F. J. Iguaz, I. G. Irastorza, M. A. Jinete, L. Labarga, A. Laing, I. Liubarsky, J. A. M. Lopes, D. Lorca, M. Losada, G. Luzón, A. Marí, J. Martín-Albo, A. Martínez, A. Moiseenko, F. Monrabal, M. Monserrate, C. M. B. Monteiro, F. J. Mora, L. M. Moutinho, J. Muñoz Vidal, H. Natal da Luz, G. Navarro, M. Nebot-Guinot, R. Palma, J. Pérez, J. L. Pérez Aparicio, L. Ripoll, A. Rodríguez, J. Rodríguez, F. P. Santos, J. M. F. dos Santos, L. Seguí, L. Serra, A. Simón, C. Sofka, M. Sorel, J. F. Toledo, A. Tomás, J. Torrent, Z. Tsamalaidze, J. F. C. A. Veloso, J. A. Villar, R. C. Webb, J. White, N. Yahlali (NEXT Collaboration)
    Sept. 9, 2014 hep-ex, nucl-ex, physics.ins-det
    ... ... ... ... ... ...
    Ionization and scintillation produced by nuclear recoils in gaseous xenon at approximately 14 bar have been simultaneously observed in an electroluminescent time projection chamber. Neutrons from radioisotope $\alpha$-Be neutron sources were used to induce xenon nuclear recoils, and the observed recoil spectra were compared to a detailed Monte Carlo employing estimated ionization and scintillation yields for nuclear recoils. The ability to discriminate between electronic and nuclear recoils using the ratio of ionization to primary scintillation is demonstrated. These results encourage further investigation on the use of xenon in the gas phase as a detector medium in dark matter direct detection experiments.
  • High Voltage in Noble Liquids for High Energy Physics (1403.3613)

    Edited by B. Rebel, C. Hall with contributions from E. Bernard, C. H. Faham, T. M. Ito, B. Lundberg, M. Messina, F. Monrabal, S. P. Pereverzev, F. Resnati, P. C. Rowson, M. Soderberg, T. Strauss, A. Tomas, J. Va'vra, H. Wang
    March 18, 2014 physics.ins-det
    ... ... ... ... ... ...
    A workshop was held at Fermilab November 8-9, 2013 to discuss the challenges of using high voltage in noble liquids. The participants spanned the fields of neutrino, dark matter, and electric dipole moment physics. All presentations at the workshop were made in plenary sessions. This document summarizes the experiences and lessons learned from experiments in these fields at developing high voltage systems in noble liquids.