Muon beams of low emittance provide the basis for the intense,
well-characterised neutrino beams necessary to elucidate the physics of flavour
at a neutrino factory and to provide lepton-antilepton collisions at energies
of up to several TeV at a muon collider. The international Muon Ionization
Cooling Experiment (MICE) aims to demonstrate ionization cooling, the technique
by which it is proposed to reduce the phase-space volume occupied by the muon
beam at such facilities. In an ionization-cooling channel, the muon beam passes
through a material in which it loses energy. The energy lost is then replaced
using RF cavities. The combined effect of energy loss and re-acceleration is to
reduce the transverse emittance of the beam (transverse cooling). A major
revision of the scope of the project was carried out over the summer of 2014.
The revised experiment can deliver a demonstration of ionization cooling. The
design of the cooling demonstration experiment will be described together with
its predicted cooling performance.
-
The international Muon Ionization Cooling Experiment (MICE) will perform a
systematic investigation of ionization cooling with muon beams of momentum
between 140 and 240\,MeV/c at the Rutherford Appleton Laboratory ISIS facility.
The measurement of ionization cooling in MICE relies on the selection of a pure
sample of muons that traverse the experiment. To make this selection, the MICE
Muon Beam is designed to deliver a beam of muons with less than $\sim$1\%
contamination. To make the final muon selection, MICE employs a
particle-identification (PID) system upstream and downstream of the cooling
cell. The PID system includes time-of-flight hodoscopes, threshold-Cherenkov
counters and calorimetry. The upper limit for the pion contamination measured
in this paper is $f_\pi < 1.4\%$ at 90\% C.L., including systematic
uncertainties. Therefore, the MICE Muon Beam is able to meet the stringent
pion-contamination requirements of the study of ionization cooling.
-
The Muon Ionization Cooling Experiment (MICE) will perform a detailed study
of ionization cooling to evaluate the feasibility of the technique. To carry
out this program, MICE requires an efficient particle-identification (PID)
system to identify muons. The Electron-Muon Ranger (EMR) is a fully-active
tracking-calorimeter that forms part of the PID system and tags muons that
traverse the cooling channel without decaying. The detector is capable of
identifying electrons with an efficiency of 98.6%, providing a purity for the
MICE beam that exceeds 99.8%. The EMR also proved to be a powerful tool for the
reconstruction of muon momenta in the range 100-280 MeV/$c$.
-
The Muon Ionization Cooling Experiment (MICE) is a strategic R&D project
intended to demonstrate the only practical solution to providing high
brilliance beams necessary for a neutrino factory or muon collider. MICE is
under development at the Rutherford Appleton Laboratory (RAL) in the United
Kingdom. It comprises a dedicated beamline to generate a range of input muon
emittances and momenta, with time-of-flight and Cherenkov detectors to ensure a
pure muon beam. The emittance of the incoming beam will be measured in the
upstream magnetic spectrometer with a scintillating fiber tracker. A cooling
cell will then follow, alternating energy loss in Liquid Hydrogen (LH2)
absorbers to RF cavity acceleration. A second spectrometer, identical to the
first, and a second muon identification system will measure the outgoing
emittance. In the 2010 run at RAL the muon beamline and most detectors were
fully commissioned and a first measurement of the emittance of the muon beam
with particle physics (time-of-flight) detectors was performed. The analysis of
these data was recently completed and is discussed in this paper. Future steps
for MICE, where beam emittance and emittance reduction (cooling) are to be
measured with greater accuracy, are also presented.
-
A search for the decay mu -> e gamma, performed at PSI and based on data from
the initial three months of operation of the MEG experiment, yields an upper
limit on the branching ratio of BR(mu -> e gamma) < 2.8 x 10**-11 (90% C.L.).
This corresponds to the measurement of positrons and photons from ~ 10**14
stopped mu-decays by means of a superconducting positron spectrometer and a 900
litre liquid xenon photon detector.
-
In the MICE experiment at RAL the upstream time-of-flight detectors are used
for particle identification in the incoming muon beam, for the experiment
trigger and for a precise timing (sigma_t ~ 50 ps) with respect to the
accelerating RF cavities working at 201 MHz. The construction of the upstream
section of the MICE time-of-flight system and the tests done to characterize
its individual components are shown. Detector timing resolutions ~50-60 ps were
achieved. Test beam performance and preliminary results obtained with beam at
RAL are reported.