While the Standard Model of particle physics does not include free particles
with fractional charge, experimental searches have not ruled out their
existence. We report results from the Cryogenic Dark Matter Search (CDMS II)
experiment that give the first direct-detection limits for
cosmogenically-produced relativistic particles with electric charge lower than
$e$/6. A search for tracks in the six stacked detectors of each of two of the
CDMS II towers found no candidates, thereby excluding new parameter space for
particles with electric charges between $e$/6 and $e$/200.
-
The Large Underground Xenon (LUX) dark matter experiment aims to detect rare
low-energy interactions from Weakly Interacting Massive Particles (WIMPs). The
radiogenic backgrounds in the LUX detector have been measured and compared with
Monte Carlo simulation. Measurements of LUX high-energy data have provided
direct constraints on all background sources contributing to the background
model. The expected background rate from the background model for the 85.3 day
WIMP search run is
$(2.6\pm0.2_{\textrm{stat}}\pm0.4_{\textrm{sys}})\times10^{-3}$~events~keV$_{ee}^{-1}$~kg$^{-1}$~day$^{-1}$
in a 118~kg fiducial volume. The observed background rate is
$(3.6\pm0.4_{\textrm{stat}})\times10^{-3}$~events~keV$_{ee}^{-1}$~kg$^{-1}$~day$^{-1}$,
consistent with model projections. The expectation for the radiogenic
background in a subsequent one-year run is presented.
-
LUX, the world's largest dual-phase xenon time-projection chamber, with a
fiducial target mass of 118 kg and 10,091 kg-days of exposure thus far, is
currently the most sensitive direct dark matter search experiment. The initial
null-result limit on the spin-independent WIMP-nucleon scattering cross-section
was released in October 2013, with a primary scintillation threshold of 2 phe,
roughly 3 keVnr for LUX. The detector has been deployed at the Sanford
Underground Research Facility (SURF) in Lead, South Dakota, and is the first
experiment to achieve a limit on the WIMP cross-section lower than $10^{-45}$
cm$^{2}$. Here we present a more in-depth discussion of the novel energy scale
employed to better understand the nuclear recoil light and charge yields, and
of the calibration sources, including the new internal tritium source. We found
the LUX data to be in conflict with low-mass WIMP signal interpretations of
other results.
-
The Large Underground Xenon (LUX) experiment, a dual-phase xenon
time-projection chamber operating at the Sanford Underground Research Facility
(Lead, South Dakota), was cooled and filled in February 2013. We report results
of the first WIMP search dataset, taken during the period April to August 2013,
presenting the analysis of 85.3 live-days of data with a fiducial volume of 118
kg. A profile-likelihood analysis technique shows our data to be consistent
with the background-only hypothesis, allowing 90% confidence limits to be set
on spin-independent WIMP-nucleon elastic scattering with a minimum upper limit
on the cross section of $7.6 \times 10^{-46}$ cm$^{2}$ at a WIMP mass of 33
GeV/c$^2$. We find that the LUX data are in strong disagreement with low-mass
WIMP signal interpretations of the results from several recent direct detection
experiments.
-
As part of the Snowmass process, the Cosmic Frontier WIMP Direct Detection
subgroup (CF1) has drawn on input from the Cosmic Frontier and the broader
Particle Physics community to produce this document. The charge to CF1 was (a)
to summarize the current status and projected sensitivity of WIMP direct
detection experiments worldwide, (b) motivate WIMP dark matter searches over a
broad parameter space by examining a spectrum of WIMP models, (c) establish a
community consensus on the type of experimental program required to explore
that parameter space, and (d) identify the common infrastructure required to
practically meet those goals.
-
Results are presented from radioactivity screening of two models of
photomultiplier tubes designed for use in current and future liquid xenon
experiments. The Hamamatsu 5.6 cm diameter R8778 PMT, used in the LUX dark
matter experiment, has yielded a positive detection of four common radioactive
isotopes: 238U, 232Th, 40K, and 60Co. Screening of LUX materials has rendered
backgrounds from other detector materials subdominant to the R8778
contribution. A prototype Hamamatsu 7.6 cm diameter R11410 MOD PMT has also
been screened, with benchmark isotope counts measured at <0.4 238U / <0.3 232Th
/ <8.3 40K / 2.0+-0.2 60Co mBq/PMT. This represents a large reduction, equal to
a change of \times 1/24 238U / \times 1/9 232Th / \times 1/8 40K per PMT,
between R8778 and R11410 MOD, concurrent with a doubling of the photocathode
surface area (4.5 cm to 6.4 cm diameter). 60Co measurements are comparable
between the PMTs, but can be significantly reduced in future R11410 MOD units
through further material selection. Assuming PMT activity equal to the measured
90% upper limits, Monte Carlo estimates indicate that replacement of R8778 PMTs
with R11410 MOD PMTs will change LUX PMT electron recoil background
contributions by a factor of \times1/25 after further material selection for
60Co reduction, and nuclear recoil backgrounds by a factor of \times 1/36. The
strong reduction in backgrounds below the measured R8778 levels makes the
R11410 MOD a very competitive technology for use in large-scale liquid xenon
detectors.
-
We present the results of the three-month above-ground commissioning run of
the Large Underground Xenon (LUX) experiment at the Sanford Underground
Research Facility located in Lead, South Dakota, USA. LUX is a 370 kg liquid
xenon detector that will search for cold dark matter in the form of Weakly
Interacting Massive Particles (WIMPs). The commissioning run, conducted with
the detector immersed in a water tank, validated the integration of the various
sub-systems in preparation of the underground deployment. Using the data
collected, we report excellent light collection properties, achieving 8.4
photoelectrons per keV for 662 keV electron recoils without an applied electric
field, measured in the center of the WIMP target. We also find good energy and
position resolution in relatively high-energy interactions from a variety of
internal and external sources. Finally, we have used the commissioning data to
tune the optical properties of our simulation and report updated sensitivity
projections for spin-independent WIMP-nucleon scattering.
-
The Large Underground Xenon (LUX) collaboration has designed and constructed
a dual-phase xenon detector, in order to conduct a search for Weakly
Interacting Massive Particles(WIMPs), a leading dark matter candidate. The goal
of the LUX detector is to clearly detect (or exclude) WIMPS with a spin
independent cross section per nucleon of $2\times 10^{-46}$ cm$^{2}$,
equivalent to $\sim$1 event/100 kg/month in the inner 100-kg fiducial volume
(FV) of the 370-kg detector. The overall background goals are set to have $<$1
background events characterized as possible WIMPs in the FV in 300 days of
running.
This paper describes the design and construction of the LUX detector.
-
We report limits on annual modulation of the low-energy event rate from the
Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground
Laboratory. Such a modulation could be produced by interactions from Weakly
Interacting Massive Particles (WIMPs) with masses ~10 GeV/c^2. We find no
evidence for annual modulation in the event rate of veto-anticoincident
single-detector interactions consistent with nuclear recoils, and constrain the
magnitude of any modulation to <0.06 event [keVnr kg day]^-1 in the 5-11.9
keVnr energy range at the 99% confidence level. These results disfavor an
explanation for the reported modulation in the 1.2-3.2 keVee energy range in
CoGeNT in terms of nuclear recoils resulting from elastic scattering of WIMPs
at >98% confidence. For events consistent with electron recoils, no significant
modulation is observed for either single- or multiple-detector interactions in
the 3.0-7.4 keVee range.
-
We report on the screening of samples of titanium metal for their
radio-purity. The screening process described in this work led to the selection
of materials used in the construction of the cryostats for the Large
Underground Xenon (LUX) dark matter experiment. Our measurements establish
titanium as a highly desirable material for low background experiments
searching for rare events. The sample with the lowest total long-lived activity
was measured to contain <0.25 mBq/kg of U-238, <0.2 mBq/kg of Th-232, and <1.2
mBq/kg of K-40. Measurements of several samples also indicated the presence of
short-lived (84 day half life) Sc-46, likely produced cosmogenically via muon
initiated (n,p) reactions.
-
Geant4 has been used throughout the nuclear and high-energy physics community
to simulate energy depositions in various detectors and materials. These
simulations have mostly been run with a source beam outside the detector. In
the case of low-background physics, however, a primary concern is the effect on
the detector from radioactivity inherent in the detector parts themselves. From
this standpoint, there is no single source or beam, but rather a collection of
sources with potentially complicated spatial extent. LUXSim is a simulation
framework used by the LUX collaboration that takes a component-centric approach
to event generation and recording. A new set of classes allows for multiple
radioactive sources to be set within any number of components at run time, with
the entire collection of sources handled within a single simulation run.
Various levels of information can also be recorded from the individual
components, with these record levels also being set at runtime. This
flexibility in both source generation and information recording is possible
without the need to recompile, reducing the complexity of code management and
the proliferation of versions. Within the code itself, casting geometry objects
within this new set of classes rather than as the default Geant4 classes
automatically extends this flexibility to every individual component. No
additional work is required on the part of the developer, reducing development
time and increasing confidence in the results. We describe the guiding
principles behind LUXSim, detail some of its unique classes and methods, and
give examples of usage.
* Corresponding author, kareem@llnl.gov
-
The LZ program consists of two stages of direct dark matter searches using
liquid Xe detectors. The first stage will be a 1.5-3 tonne detector, while the
last stage will be a 20 tonne detector. Both devices will benefit tremendously
from research and development performed for the LUX experiment, a 350 kg liquid
Xe dark matter detector currently operating at the Sanford Underground
Laboratory. In particular, the technology used for cryogenics and electrical
feedthroughs, circulation and purification, low-background materials and
shielding techniques, electronics, calibrations, and automated control and
recovery systems are all directly scalable from LUX to the LZ detectors.
Extensive searches for potential background sources have been performed, with
an emphasis on previously undiscovered background sources that may have a
significant impact on tonne-scale detectors. The LZ detectors will probe
spin-independent interaction cross sections as low as 5E-49 cm2 for 100 GeV
WIMPs, which represents the ultimate limit for dark matter detection with
liquid xenon technology.
-
LUX is a two-phase (liquid/gas) xenon time projection chamber designed to
detect nuclear recoils from interactions with dark matter particles. Signals
from the LUX detector are processed by custom-built analog electronics which
provide properly shaped signals for the trigger and data acquisition (DAQ)
systems. The DAQ is comprised of commercial digitizers with firmware customized
for the LUX experiment. Data acquisition systems in rare-event searches must
accommodate high rate and large dynamic range during precision calibrations
involving radioactive sources, while also delivering low threshold for maximum
sensitivity. The LUX DAQ meets these challenges using real-time baseline sup-
pression that allows for a maximum event acquisition rate in excess of 1.5 kHz
with virtually no deadtime. This paper describes the LUX DAQ and the novel
acquisition techniques employed in the LUX experiment.
-
The CDMS and EDELWEISS collaborations have combined the results of their
direct searches for dark matter using cryogenic germanium detectors. The total
data set represents 614 kg.d equivalent exposure. A straightforward method of
combination was chosen for its simplicity before data were exchanged between
experiments. The results are interpreted in terms of limits on spin-independent
WIMP-nucleon cross-section. For a WIMP mass of 90 GeV/c^2, where this analysis
is most sensitive, a cross-section of 3.3 x 10^{-44} cm^2 is excluded at 90%
CL. At higher WIMP masses, the combination improves the individual limits, by a
factor 1.6 above 700 GeV/c^2. Alternative methods of combining the data provide
stronger constraints for some ranges of WIMP masses and weaker constraints for
others.
-
Results are presented from a reanalysis of the entire five-tower data set
acquired with the Cryogenic Dark Matter Search (CDMS II) experiment at the
Soudan Underground Laboratory, with an exposure of 969 kg-days. The analysis
window was extended to a recoil energy of 150 keV, and an improved
surface-event background-rejection cut was defined to increase the sensitivity
of the experiment to the inelastic dark matter (iDM) model. Three dark matter
candidates were found between 25 keV and 150 keV. The probability to observe
three or more background events in this energy range is 11%. Because of the
occurrence of these events the constraints on the iDM parameter space are
slightly less stringent than those from our previous analysis, which used an
energy window of 10-100 keV.
-
We report results from a reanalysis of data from the Cryogenic Dark Matter
Search (CDMS II) experiment at the Soudan Underground Laboratory. Data taken
between October 2006 and September 2008 using eight germanium detectors are
reanalyzed with a lowered, 2 keV recoil-energy threshold, to give increased
sensitivity to interactions from Weakly Interacting Massive Particles (WIMPs)
with masses below ~10 GeV/c^2. This analysis provides stronger constraints than
previous CDMS II results for WIMP masses below 9 GeV/c^2 and excludes parameter
space associated with possible low-mass WIMP signals from the DAMA/LIBRA and
CoGeNT experiments.
-
Data taken during the final shallow-site run of the first tower of the
Cryogenic Dark Matter Search (CDMS II) detectors have been reanalyzed with
improved sensitivity to small energy depositions. Four ~224 g germanium and two
~105 g silicon detectors were operated at the Stanford Underground Facility
(SUF) between December 2001 and June 2002, yielding 118 live days of raw
exposure. Three of the germanium and both silicon detectors were analyzed with
a new low-threshold technique, making it possible to lower the germanium and
silicon analysis thresholds down to the actual trigger thresholds of ~1 keV and
~2 keV, respectively. Limits on the spin-independent cross section for weakly
interacting massive particles (WIMPs) to elastically scatter from nuclei based
on these data exclude interesting parameter space for WIMPs with masses below 9
GeV/c^2. Under standard halo assumptions, these data partially exclude
parameter space favored by interpretations of the DAMA/LIBRA and CoGeNT
experiments' data as WIMP signals, and exclude new parameter space for WIMP
masses between 3 GeV/c^2 and 4 GeV/c^2.
-
We report on the analysis of the low-energy electron-recoil spectrum from the
CDMS II experiment using data with an exposure of 443.2 kg-days. The analysis
provides details on the observed counting rate and possible background sources
in the energy range of 2 - 8.5 keV. We find no significant excess in the
counting rate above background, and compare this observation to the recent DAMA
results. In the framework of a conversion of a dark matter particle into
electromagnetic energy, our 90% confidence level upper limit of 0.246
events/kg/day at 3.15 keV is lower than the total rate above background
observed by DAMA by 8.9$\sigma$. In absence of any specific particle physics
model to provide the scaling in cross section between NaI and Ge, we assume a
Z^2 scaling. With this assumption the observed rate in DAMA differs from the
upper limit in CDMS by 6.8$\sigma$. Under the conservative assumption that the
modulation amplitude is 6% of the total rate we obtain upper limits on the
modulation amplitude a factor of ~2 less than observed by DAMA, constraining
some possible interpretations of this modulation.
-
A study of the current status of WIMP dark matter searches has been made in
the context of scientific and technical planning for a Deep Underground Science
and Engineering Laboratory (DUSEL) in the U.S. The table of contents follows:
1. Overview
2. WIMP Dark Matter: Cosmology, Astrophysics, and Particle Physics
3. Direct Detection of WIMPs
4. Indirect Detection of WIMPs
5. Dark Matter Candidates and New Physics in the Laboratory
6. Synergies with Other Sub-Fields
7. Direct Detection Experiments: Status and Future Prospects
8. Infrastructure
9. International Context
10. Summary and Outlook
11. Acknowledgments
-
Presently the CDMS-II collaboration's Weakly Interacting Massive Particle
(WIMP) search at the Soudan Underground Laboratory sets the most stringent
exclusion limits of any WIMP cold dark matter direct-detection experiment. To
extend our reach further, to WIMP-nucleon cross sections in the range $10^{-46}
- 10^{-44}$cm$^2$, we propose SuperCDMS, which would take advantage of a very
deep site. One promising site is the recently approved SNOLab facility in
Canada. In this paper we will present our overall plan, identify primary
issues, and set the goals that need to be met prior to embarking upon each
phase of SuperCDMS.