-
We present experimental constraints on the spin-dependent WIMP-nucleon
elastic cross sections from the total 129.5 kg-year exposure acquired by the
Large Underground Xenon experiment (LUX), operating at the Sanford Underground
Research Facility in Lead, South Dakota (USA). A profile likelihood ratio
analysis allows 90% CL upper limits to be set on the WIMP-neutron (WIMP-proton)
cross section of $\sigma_n$ = 1.6$\times 10^{-41}$ cm$^{2}$ ($\sigma_p$ =
5$\times 10^{-40}$ cm$^{2}$) at 35 GeV$c^{-2}$, almost a sixfold improvement
over the previous LUX spin-dependent results. The spin-dependent WIMP-neutron
limit is the most sensitive constraint to date.
-
We report constraints on spin-independent weakly interacting massive particle
(WIMP)-nucleon scattering using a 3.35e4 kg-day exposure of the Large
Underground Xenon (LUX) experiment. A dual-phase xenon time projection chamber
with 250 kg of active mass is operated at the Sanford Underground Research
Facility under Lead, South Dakota (USA). With roughly fourfold improvement in
sensitivity for high WIMP masses relative to our previous results, this search
yields no evidence of WIMP nuclear recoils. At a WIMP mass of 50 GeV/c^2,
WIMP-nucleon spin-independent cross sections above 2.2e-46 cm^2 are excluded at
the 90% confidence level. When combined with the previously reported LUX
exposure, this exclusion strengthens to 1.1e-46 cm^2 at 50 GeV/c^2.
-
The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon
time projection chamber (TPC) operating at the Sanford Underground Research
Facility in Lead, South Dakota. A calibration of nuclear recoils in liquid
xenon was performed $\textit{in situ}$ in the LUX detector using a collimated
beam of mono-energetic 2.45 MeV neutrons produced by a deuterium-deuterium
(D-D) fusion source. The nuclear recoil energy from the first neutron scatter
in the TPC was reconstructed using the measured scattering angle defined by
double-scatter neutron events within the active xenon volume. We measured the
absolute charge ($Q_{y}$) and light ($L_{y}$) yields at an average electric
field of 180 V/cm for nuclear recoil energies spanning 0.7 to 74 keV and 1.1 to
74 keV, respectively. This calibration of the nuclear recoil signal yields will
permit the further refinement of liquid xenon nuclear recoil signal models and,
importantly for dark matter searches, clearly demonstrates measured ionization
and scintillation signals in this medium at recoil energies down to
$\mathcal{O}$(1 keV).
-
We present the first experimental constraints on the spin-dependent
WIMP-nucleon elastic cross sections from LUX data acquired in 2013. LUX is a
dual-phase xenon time projection chamber operating at the Sanford Underground
Research Facility (Lead, South Dakota), which is designed to observe the recoil
signature of galactic WIMPs scattering from xenon nuclei. A profile likelihood
ratio analysis of $1.4~\times~10^{4}~\text{kg}\cdot~\text{days}$ of fiducial
exposure allows 90% CL upper limits to be set on the WIMP-neutron (WIMP-proton)
cross section of $\sigma_n~=~9.4~\times~10^{-41}~\text{cm}^2$
($\sigma_p~=~2.9~\times~10^{-39}~\text{cm}^2$) at 33 GeV/c$^2$. The
spin-dependent WIMP-neutron limit is the most sensitive constraint to date.
-
We present constraints on weakly interacting massive particles (WIMP)-nucleus
scattering from the 2013 data of the Large Underground Xenon dark matter
experiment, including $1.4\times10^{4}\;\mathrm{kg\; day}$ of search exposure.
This new analysis incorporates several advances: single-photon calibration at
the scintillation wavelength, improved event-reconstruction algorithms, a
revised background model including events originating on the detector walls in
an enlarged fiducial volume, and new calibrations from decays of an injected
tritium $\beta$ source and from kinematically constrained nuclear recoils down
to 1.1 keV. Sensitivity, especially to low-mass WIMPs, is enhanced compared to
our previous results which modeled the signal only above a 3 keV minimum
energy. Under standard dark matter halo assumptions and in the mass range above
4 $\mathrm{GeV}\,c^{-2}$, these new results give the most stringent direct
limits on the spin-independent WIMP-nucleon cross section. The 90% C.L. upper
limit has a minimum of 0.6 zb at 33 $\mathrm{GeV}\,c^{-2}$ WIMP mass.
-
We present measurements of the electron-recoil (ER) response of the LUX dark
matter detector based upon 170,000 highly pure and spatially-uniform tritium
decays. We reconstruct the tritium energy spectrum using the combined energy
model and find good agreement with expectations. We report the average charge
and light yields of ER events in liquid xenon at 180 V/cm and 105 V/cm and
compare the results to the NEST model. We also measure the mean charge
recombination fraction and its fluctuations, and we investigate the location
and width of the LUX ER band. These results provide input to a re-analysis of
the LUX Run3 WIMP search.
-
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of
March 2015 in this Conceptual Design Report. LZ is a second-generation
dark-matter detector with the potential for unprecedented sensitivity to weakly
interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds
of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most
sensitive experiment for WIMPs in this mass region by the end of the decade.
This report describes in detail the design of the LZ technical systems.
Expected backgrounds are quantified and the performance of the experiment is
presented. The LZ detector will be located at the Sanford Underground Research
Facility in South Dakota. The organization of the LZ Project and a summary of
the expected cost and current schedule are given.