• Login
    Sort by: Relevance Date Users's collections Twitter
    Group by: Day Week Month Year All time
Based on the idea and the provided source code of Andrej Karpathy (arxiv-sanity)
2:3 1:1 3:2
  • Neutron spectroscopy with the Spherical Proportional Counter (1512.04346)

    E. Bougamont, A. Dastgheibi, J. Derre, J. Galan, G. Gerbier, I. Giomataris, M. Gros, I.Katsioulas, D. Jourde, P. Magnier, X.F. Navick, T. Papaevangelou, I. Savvidis, G. Tsiledakis
    Sept. 19, 2017 physics.ins-det
    A novel large volume spherical proportional counter, recently developed, is used for neutron measurements. Gas mixtures of $N_{2}$ with $C_{2}H_{6}$ and pure $N_{2}$ are studied for thermal and fast neutron detection, providing a new way for the neutron spectroscopy. The neutrons are detected via the ${}^{14}N(n, p)C^{14}$ and ${}^{14}N(n, \alpha)B^{11}$ reactions. Here we provide studies of the optimum gas mixture, the gas pressure and the most appropriate high voltage supply on the sensor of the detector in order to achieve the maximum amplification and better resolution. The detector is tested for thermal and fast neutrons detection with a ${}^{252}Cf$ and a ${}^{241}Am-{}^{9}Be$ neutron source. The atmospheric neutrons are successfully measured from thermal up to several MeV, well separated from the cosmic ray background. A comparison of the spherical proportional counter with the current available neutron counters is also given.
  • Cosmogenic production of tritium in dark matter detectors (1706.05818)

    J. Amare, J. Castel, S. Cebrian, I. Coarasa, C. Cuesta, T. Dafni, J. Galan, E. Garcia, J.G. Garza, F.J. Iguaz, I.G. Irastorza, G. Luzon, M. Martinez, H. Mirallas, M.A. Olivan, Y. Ortigoza, A. Ortiz de Solorzano, J. Puimedon, E. Ruiz-Choliz, M.L. Sarsa, J.A. Villar, P. Villar
    June 19, 2017 hep-ex, physics.ins-det, astro-ph.IM
    ... ... ... ... ... ...
    The direct detection of dark matter particles requires ultra-low background conditions at energies below a few tens of keV; cosmogenic activation produced at sea level in detectors and other materials is one of the background sources which has to be under control. In particular, tritium is specially relevant for its decay properties (very low endpoint energy and long half-life) when induced in the detector medium, and because it can be generated in any material as an spallation product. Quantification of cosmogenic production of tritium is not easy. A method for the calculation of production rates at sea level has been developed and applied to some of the materials typically used as targets in dark matter detectors (germanium, sodium iodide, argon and neon); it is based on a selection of excitation functions over the entire energy range of cosmic nucleons. Results have been compared with available data in the literature, either from other calculations or from measurements. The obtained tritium production rates, ranging from a few tens to a few hundreds of nuclei per kg and per day at sea level, point to a significant contribution to the background in dark matter experiments, requiring the application of specific protocols for target material purification, material storing underground and limiting the time the detector is on surface during the building process in order to minimize the exposure to the most dangerous cosmic rays component.
  • Readout technologies for directional WIMP Dark Matter detection (1610.02396)

    J. B. R. Battat, I. G. Irastorza, A. Aleksandrov, M. Ali Guler, T. Asada, E. Baracchini, J. Billard, G. Bosson, O. Bourrion, J. Bouvier, A. Buonaura, K. Burdge, S. Cebrian, P. Colas, L. Consiglio, T. Dafni, N. D'Ambrosio, C. Deaconu, G. De Lellis, T. Descombes, A. Di Crescenzo, N. Di Marco, G. Druitt, R. Eggleston, E. Ferrer-Ribas, T. Fusayasu, J. Galan, G. Galati, J. A. Garcia, J. G. Garza, V. Gentile, M. Garcia-Sciveres, Y. Giomataris, N. Guerrero, O. Guillaudin, J. Harton, T. Hashimoto, M. T. Hedges, F. Iguaz, T. Ikeda, I. Jaegle, J. A. Kadyk, T. Katsuragawa, S. Komura, H. Kubo, K. Kuge, J. Lamblin, A. Lauria, E. R. Lee, P. Lewis, M. Leyton, D. Loomba, J. P. Lopez, G. Luzon, F. Mayet, H. Mirallas, K. Miuchi, T. Mizumoto, Y. Mizumura, P. Monacelli, J. Monroe, M. C. Montesi, T. Naka, K. Nakamura, H. Nishimura, A. Ochi, T. Papevangelou, J. D. Parker, N. S. Phan, F. Pupilli, J. P. Richer, Q. Riffard, G. Rosa, D. Santos, T. Sawano, H. Sekiya, I. S. Seong, D. P. Snowden-Ifft, N. J. C. Spooner, A. Sugiyama, R. Taishaku, A. Takada, A. Takeda, M. Tanaka, T. Tanimori, T. N. Thorpe, V. Tioukov, H. Tomita, A. Umemoto, S. E. Vahsen, Y. Yamaguchi, M. Yoshimoto, E. Zayas
    Oct. 6, 2016 hep-ex, physics.ins-det, astro-ph.CO, astro-ph.IM
    ... ... ... ... ... ...
    The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial resolution over large volumes, which puts strong requirements on the readout technologies. In this paper we review the various detector readout technologies used by directional detectors. In particular, we summarize the challenges, advantages and drawbacks of each approach, and discuss future prospects for these technologies.
  • The potential of discrimination methods in a high pressure xenon TPC for the search of the neutrinoless double-beta decay of Xe-136 (1609.09735)

    F.J. Iguaz, F. Aznar, J.F. Castel, S. Cebrian, T. Dafni, J. Galan, J.G. Garza, I.G. Irastorza, G. Luzon, H. Mirallas, E. Ruiz-Choliz
    Sept. 30, 2016 hep-ex, physics.ins-det
    ... ... ... ... ... ...
    In the search for the neutrinoless double beta decay of $^{136}$Xe, a high pressure xenon time projection chamber (HPXe-TPC) has two advantages over liquid xenon TPCs: a better energy resolution and the access to topological features, which may provide extra discrimination from background events. The PandaX-III experiment has recently proposed a 200 kg HPXe-TPC based on Micromegas readout planes, to be located at the Jinping Underground Laboratory in China. Its detection concept is based on two results obtained within the T-REX project: Micromegas readouts can be built with extremely low levels of radioactivity; and the operation in xenon-trimethylamine at 10 bar in realistic experimental conditions has proven an energy resolution of 3% FWHM at the region of interest. In this work, two discrimination methods are applied to simulated signal and background data in a generic 200 kg HPXe-TPC, based on two well-known algorithms of graph theory: the identification of connections and the search for the longest path. Rejection factors greater than 100 are obtained for small pixel sizes and a signal efficiency of 40%. Moreover, a new observable (the blob charge density) rejects better surface contaminations, which makes the use of a trigger signal ($T_0$) not imperative in this experiment.
  • Micromegas for dark matter searches: CAST/IAXO & TREX-DM (1609.06459)

    J. G. Garza, S. Aune, J. F. Castel, S. Cebrián, T. Dafni, E. Ferrer-Ribas, J. Galán, J. A. García, I. Giomataris, F. J. Iguaz, I. G. Irastorza, G. Luzón, H. Mirallas, T. Papaevangelou, A. Peiró, A. Tomás, T. Vafeiadis
    Sept. 21, 2016 hep-ex, physics.ins-det
    ... ... ... ... ... ...
    The most compelling candidates for Dark Matter to day are WIMPs and axions. The applicability of gasesous Time Projection Chambers (TPCs) with Micromesh Gas Structures (Micromegas) to the search of these particles is explored within this work. Both particles would produce an extremely low rate at very low energies in particle detectors. Micromegas detectors can provide both low background rates and low en- ergy threshold, due to the high granularity, radiopurity and uniformity of the readout. Small (few cm wide) Micromegas detectors are used to image the axion-induced x-ray signal expected in the CERN Axion Solar Telescope (CAST) experiment. We show the background levels obtained in CAST and the prospects to further reduce them to the values required by the Internation Axion Observatory (IAXO). We also present TREX-DM, a scaled-up version of the Micromegas used in axion research, but this time dedicated to the low-mass WIMP detection. TREX-DM is a high-pressure Micromegas-based TPC designed to host a few hundreds of grams of light nuclei (argon or neon) with energy thresholds potentially at the level of 100 eV. The detector is described in detail, as well as the results of the commissioning and characterization phase on surface. Besides, the back- ground model of TREX-DM is presented, along with the anticipated sensitivity of this search, which could go beyond current experimental limits.
  • Gaseous time projection chambers for rare event detection: Results from the T-REX project. II. Dark matter (1512.06294)

    I. G. Irastorza, F. Aznar, J. Castel, S. Cebrián, T. Dafni, J. Galán, J. A. García, J. G. Garza, H. Gómez, D. C. Herrera, F. J. Iguaz, G. Luzón, H. Mirallas, E. Ruiz, L. Seguí, A. Tomás
    May 6, 2016 hep-ex, physics.ins-det
    ... ... ... ... ... ...
    As part of the T-REX project, a number of R&D and prototyping activities have been carried out during the last years to explore the applicability of Micromegas-read gaseous TPCs in rare event searches like double beta decay (DBD), axion research and low-mass WIMP searches. While in the companion paper we focus on DBD, in this paper we focus on the results regarding the search for dark matter candidates, both axions and WIMPs. Small ultra-low background Micromegas detectors are used to image the x-ray signal expected in axion helioscopes like CAST at CERN. Background levels as low as $0.8\times 10^{-6}$ c keV$^{-1}$cm$^{-2}$s$^{-1}$ have already been achieved in CAST while values down to $\sim10^{-7}$ c keV$^{-1}$cm$^{-2}$s$^{-1}$ have been obtained in a test bench placed underground in the Laboratorio Subterr\'aneo de Canfranc. Prospects to consolidate and further reduce these values down to $\sim10^{-8}$ c keV$^{-1}$cm$^{-2}$s$^{-1}$will be described. Such detectors, placed at the focal point of x-ray telescopes in the future IAXO experiment, would allow for 10$^5$ better signal-to-noise ratio than CAST, and search for solar axions with $g_{a\gamma}$ down to few 10$^{12}$ GeV$^{-1}$, well into unexplored axion parameter space. In addition, a scaled-up version of these TPCs, properly shielded and placed underground, can be competitive in the search for low-mass WIMPs. The TREX-DM prototype, with $\sim$0.300 kg of Ar at 10 bar, or alternatively $\sim$0.160 kg of Ne at 10 bar, and energy threshold well below 1 keV, has been built to test this concept. We will describe the main technical solutions developed, as well as the results from the commissioning phase on surface. The anticipated sensitivity of this technique might reach $\sim10^{-44}$ cm$^2$ for low mass ($<10$ GeV) WIMPs, well beyond current experimental limits in this mass range.
  • Microbulk Micromegas for the search of 0$\nu\beta\beta$ of 136Xe in the PandaX-III experiment (1512.09034)

    J. Galan
    Dec. 30, 2015 physics.atom-ph, physics.ins-det
    ... ... ... ... ... ...
    The search for the neutrinoless double beta decay (0$\nu\beta\beta$) is one of the most important quests nowadays in neutrino physics. Among the different techniques used, high pressure xenon (HPXe) gas time projection chambers (TPC) stand out because they allow to image the topology of the 0$\nu\beta\beta$ event (one straggling track ending in two blobs), and use it to discriminate signal from background events. Recent results with microbulk Micromegas in Xe + trimethylamine (TMA) mixtures show high promise in terms of gain, stability of operation, and energy resolution at high pressures (up to 10 bar). The addition of TMA at levels of ~1\% reduces electron diffusion in up to a factor of 10 with respect pure Xe, improving the quality of the topological pattern, and therefore the discrimination capability. Moreover microbulk Micromegas have very low levels of intrinsic radioactivity. All these results show that a Micromegas-read High Pressure Xenon TPC (HPXe-TPC) can be a competitive technique in the search for 0$\nu\beta\beta$. The recently proposed PandaX-III experiment, based on these results, aims at building a large TPC of 200 kg of enriched Xe, to be located at Jinping Underground laboratory in China. In this talk the main features of the experiment will be presented, with an emphasis on the design and tests of the microbulk readout, as well as the status of the project and first results of the prototyping phase.
  • Gaseous time projection chambers for rare event detection: Results from the T-REX project. I. Double beta decay (1512.07926)

    I. G. Irastorza, F. Aznar, J. Castel, S. Cebrián, T. Dafni, J. Galán, J. A. García, J. G. Garza, H. Gómez, D. C. Herrera, F. J. Iguaz, G. Luzón, H. Mirallas, E. Ruiz, L. Seguí, A. Tomás
    Dec. 24, 2015 hep-ex, physics.ins-det
    ... ... ... ... ... ...
    As part of the T-REX project, a number of R&D and prototyping activities have been carried out during the last years to explore the applicability of gaseous Micromegas-read TPCs in rare event searches like double beta decay (DBD), axion research and low-mass WIMP searches. In both this and its companion paper, we compile the main results of the project and give an outlook of application prospects for this detection technique. While in the companion paper we focus on axions and WIMPs, in this paper we focus on the results regarding the measurement of the DBD of $^{136}$Xe in a high pressure Xe (HPXe) TPC. Particularly relevant are the results obtained in Xe + TMA mixtures with microbulk Micromegas, showing very promising results in terms of gain, stability of operation, and energy resolution at pressures up to 10 bar. TMA at levels of $\sim$1\% reduces electron diffusion by a factor of 10 with respect to pure Xe, improving the quality of the topological pattern, with a positive impact on the discrimination capability. Operation with a medium size prototype (30 cm diameter and 38 cm drift) of 1 kg of Xe at 10 bar in the fiducial volumen has allowed to test the detection concept in realistic experimental conditions. Microbulk Micromegas are able to image the DBD ionization signature with high quality while, at the same time, measuring its energy deposition with a resolution of at least $\sim$3% FWHM @ Q$_{\beta\beta}$, and probably down to $\sim$1% FWHM. In addition, first results on the topological signature information show promising background discrimination capabilities out of reach of other experimental implementations. Moreover, microbulk Micromegas have very low levels of intrinsic radioactivity, and offer cost-effective scaling-up options. All these results demonstrate that Micromegas-read HPXe TPC is a very competitive technique for the next generation DBD experiments.
  • Exploring 0.1-10$\,$eV axions with a new helioscope concept (1508.03006)

    J. Galán, T. Dafni, E. Ferrer-Ribas, I. Giomataris, F.J. Iguaz, I.G. Irastorza, J.A. García, J. Gracia, G. Luzón, T. Papaevangelou, J. Redondo, A. Tomás
    Sept. 7, 2015 physics.ins-det, astro-ph.IM
    ... ... ... ... ... ...
    We explore the possibility to develop a new axion helioscope type, sensitive to the higher axion mass region favored by axion models. We propose to use a low background large volume TPC immersed in an intense magnetic field. Contrary to traditional tracking helioscopes, this detection technique takes advantage of the capability to directly detect the photons converted on the buffer gas which defines the axion mass sensitivity region, and does not require pointing the magnet to the Sun. The operation flexibility of a TPC to be used with different gas mixtures (He, Ne, Xe, etc) and pressures (from 10 mbar to 10 bar) will allow to enhance sensitivity for axion masses from few meV to several eV. We present different helioscope data taking scenarios, considering detection efficiency and axion absorption probability, and show the sensitivities reachable with this technique to be few $\times$ 10$^{-11}\,$GeV$^{-1}$ for a 5$\,$T$\,$m$^3$ scale TPC. We show that a few years program taking data with such setup would allow to probe the KSVZ axion model for axion masses above 100 meV.
  • New solar axion search in CAST with $^4$He filling (1503.00610)

    M. Arik, S. Aune, K. Barth, A. Belov, H. Bräuninger, J. Bremer, V. Burwitz, G. Cantatore, J. M. Carmona, S. A. Cetin, J. I. Collar, E. Da Riva, T. Dafni, M. Davenport, A. Dermenev, C. Eleftheriadis, N. Elias, G. Fanourakis, E. Ferrer-Ribas, J. Galán, J. A. García, A. Gardikiotis, J. G. Garza, E. N. Gazis, T. Geralis, E. Georgiopoulou, I. Giomataris, S. Gninenko, M. Gómez Marzoa, M. D. Hasinoff, D. H. H. Hoffmann, F. J. Iguaz, I. G. Irastorza, J. Jacoby, K. Jakovčić, M. Karuza, M. Kavuk, M. Krčmar, M. Kuster, B. Lakić, J. M. Laurent, A. Liolios, A. Ljubičić, G. Luzón, S. Neff, T. Niinikoski, A. Nordt, I. Ortega, T. Papaevangelou, M. J. Pivovaroff, G. Raffelt A. Rodríguez, M. Rosu, J. Ruz, I. Savvidis, I. Shilon, S. K. Solanki, L. Stewart, A. Tomás, T. Vafeiadis, J. Villar, J. K. Vogel, S. C. Yildiz, K. Zioutas
    June 11, 2015 hep-ex, physics.ins-det
    ... ... ... ... ... ...
    The CERN Axion Solar Telescope (CAST) searches for $a\to\gamma$ conversion in the 9 T magnetic field of a refurbished LHC test magnet that can be directed toward the Sun. Two parallel magnet bores can be filled with helium of adjustable pressure to match the X-ray refractive mass $m_\gamma$ to the axion search mass $m_a$. After the vacuum phase (2003--2004), which is optimal for $m_a\lesssim0.02$ eV, we used $^4$He in 2005--2007 to cover the mass range of 0.02--0.39 eV and $^3$He in 2009--2011 to scan from 0.39--1.17 eV. After improving the detectors and shielding, we returned to $^4$He in 2012 to investigate a narrow $m_a$ range around 0.2 eV ("candidate setting" of our earlier search) and 0.39--0.42 eV, the upper axion mass range reachable with $^4$He, to "cross the axion line" for the KSVZ model. We have improved the limit on the axion-photon coupling to $g_{a\gamma}< 1.47\times10^{-10} {\rm GeV}^{-1}$ (95% C.L.), depending on the pressure settings. Since 2013, we have returned to vacuum and aim for a significant increase in sensitivity.
  • Low Background Micromegas in CAST (1503.05107)

    J. G. Garza, S. Aune, D. Calvet, J. F. Castel, F. E. Christensen, T. Dafni, M. Davenport, T. Decker, E. Ferrer-Ribas, J. Galán, J. A. García, I. Giomataris, R. M. Hill, F. J. Iguaz, I. G. Irastorza, A. C. Jakobsen, D. Jourde, H. Mirallas, I. Ortega, T. Papaevangelou, M. J. Pivovaroff, J. Ruz, A. Tomás, T. Vafeiadis, J. K. Vogel
    March 17, 2015 nucl-ex, physics.ins-det
    ... ... ... ... ... ...
    Solar axions could be converted into x-rays inside the strong magnetic field of an axion helioscope, triggering the detection of this elusive particle. Low background x-ray detectors are an essential component for the sensitivity of these searches. We report on the latest developments of the Micromegas detectors for the CERN Axion Solar Telescope (CAST), including technological pathfinder activities for the future International Axion Observatory (IAXO). The use of low background techniques and the application of discrimination algorithms based on the high granularity of the readout have led to background levels below 10$^{-6}$ counts/keV/cm$^2$/s, more than a factor 100 lower than the first generation of Micromegas detectors. The best levels achieved at the Canfranc Underground Laboratory (LSC) are as low as 10$^{-7}$ counts/keV/cm$^2$/s, showing good prospects for the application of this technology in IAXO. The current background model, based on underground and surface measurements, is presented, as well as the strategies to further reduce the background level. Finally, we will describe the R&D paths to achieve sub-keV energy thresholds, which could broaden the physics case of axion helioscopes.
  • Lowering the background level and the energy threshold of Micromegas x-ray detectors for axion searches (1501.01466)

    F.J. Iguaz, S. Aune, F. Aznar, J.F. Castel, T. Dafni, M. Davenport, E. Ferrer-Ribas, J. Galan, J.A. Garcia, J.G. Garza, I. Giomataris, I.G. Irastorza, T. Papaevangelou, A. Rodriguez, A. Tomas, T. Vafeiadis, S.C. Yildiz
    Jan. 7, 2015 hep-ex, physics.ins-det, astro-ph.IM
    ... ... ... ... ... ...
    Axion helioscopes search for solar axions by their conversion in x-rays in the presence of high magnetic fields. The use of low background x-ray detectors is an essential component contributing to the sensitivity of these searches. In this work, we review the recent advances on Micromegas detectors used in the CERN Axion Solar Telescope (CAST) and proposed for the future International Axion Observatory (IAXO). The actual setup in CAST has achieved background levels below 10$^{-6}$ keV$^{-1}$ cm$^{-2}$ s$^{-1}$, a factor 100 lower than the first generation of Micromegas detectors. This reduction is based on active and passive shielding techniques, the selection of radiopure materials, offline discrimination techniques and the high granularity of the readout. We describe in detail the background model of the detector, based on its operation at CAST site and at the Canfranc Underground Laboratory (LSC), as well as on Geant4 simulations. The best levels currently achieved at LSC are low than 10$^{-7}$ keV$^{-1}$ cm$^{-2}$ s$^{-1}$ and show good prospects for the application of this technology in IAXO. Finally, we present some ideas and results for reducing the energy threshold of these detectors below 1 keV, using high-transparent windows, autotrigger electronics and studying the cluster shape at different energies. As a high flux of axion-like-particles is expected in this energy range, a sub-keV threshold detector could enlarge the physics case of axion helioscopes.
  • Background optimization for a new spherical gas detector for very light WIMP detection (1412.0161)

    Ali Dastgheibi-Fard, I. Giomataris, G. Gerbierb, J. Derree, M. Gros, P. Magnier, D. Jourde, E .Bougamont, X-F. Navick, T. Papaevangelou, J. Galan, G. Tsiledakis, F. Piquemal, M. Zampaolo, P. Loaiza, I. Savvidis
    Nov. 29, 2014 physics.ins-det, astro-ph.IM
    ... ... ... ... ... ...
    The Spherical gaseous detector (or Spherical Proportional Counter, SPC) is a novel type of par- ticle detector, with a broad range of applications. Its main features include a very low energy threshold independent of the volume (due to its very low capacitance), a good energy resolution, robustness and a single detection readout channel, in its simplest version. Applications range from radon emanation gas monitoring, neutron flux and gamma counting and spectroscopy to dark matter searches, in particular low mass WIMPs and coherent neutrino scattering measure- ment. Laboratories interested in these various applications share expertise within the NEWS (New Experiments With Sphere) network. SEDINE, a low background prototype installed at underground site of Laboratoire Souterrain de Modane is currently being operated and aims at measuring events at very low energy threshold, around 100 eV. We will present the energy cali- bration with 37Ar, the surface background reduction, the measurement of detector background at sub-keV energies, and show anticipated sensitivities for light dark matter search.
  • CAST solar axion search with 3^He buffer gas: Closing the hot dark matter gap (1307.1985)

    M. Arik, S. Aune, K. Barth, A. Belov, S. Borghi, H. Brauninger, G. Cantatore, J. M. Carmona, S. A. Cetin, J. I. Collar, E. Da Riva, T. Dafni, M. Davenport, C. Eleftheriadis, N. Elias, G. Fanourakis, E. Ferrer-Ribas, P. Friedrich, J. Galan, J. A. Garcia, A. Gardikiotis, J. G. Garza, E. N. Gazis, T. Geralis, E. Georgiopoulou, I. Giomataris, S. Gninenko, H. Gomez, M. Gomez Marzoa, E. Gruber, T. Guthorl, R. Hartmann, S. Hauf, F. Haug, M. D. Hasinoff, D. H. H. Hoffmann, F. J. Iguaz, I. G. Irastorza, J. Jacoby, K. Jakovcic, M. Karuza, K. Konigsmann, R. Kotthaus, M. Krcmar, M. Kuster, B. Lakic, P. M. Lang, J. M. Laurent, A. Liolios, A. Ljubicic, V. Lozza, G. Luzon, S. Neff, T. Niinikoski, A. Nordt, T. Papaevangelou, M. J. Pivovaroff, G. Raffelt, H. Riege, A. Rodriguez, M. Rosu, J. Ruz, I. Savvidis, I. Shilon, P. S. Silva, S. K. Solanki, L. Stewart, A. Tomas, M. Tsagri, K. van Bibber, T. Vafeiadis, J. Villar, J. K. Vogel, S. C. Yildiz, K. Zioutas
    Sept. 15, 2014 hep-ex, physics.ins-det, astro-ph.IM
    ... ... ... ... ... ...
    The CERN Axion Solar Telescope (CAST) has finished its search for solar axions with 3^He buffer gas, covering the search range 0.64 eV < m_a <1.17 eV. This closes the gap to the cosmological hot dark matter limit and actually overlaps with it. From the absence of excess X-rays when the magnet was pointing to the Sun we set a typical upper limit on the axion-photon coupling of g_ag < 3.3 x 10^{-10} GeV^{-1} at 95% CL, with the exact value depending on the pressure setting. Future direct solar axion searches will focus on increasing the sensitivity to smaller values of g_a, for example by the currently discussed next generation helioscope IAXO.
  • NEWS : a new spherical gas detector for very low mass WIMP detection (1401.7902)

    G. Gerbier, I. Giomataris, P. Magnier, A. Dastgheibi, M. Gros, D. Jourde, E. Bougamont, X.F. Navick, T. Papaevangelou, J. Galan, J. Derre, I. Savvidis, G. Tsiledakis
    Jan. 30, 2014 hep-ex, physics.ins-det, astro-ph.IM
    ... ... ... ... ... ...
    The main characteristics of a new concept of spherical gaseous detectors, with some details on its operation are first given. The very low energy threshold of such detector has led to investigations of its potential performance for dark matter particle searches, in particular low mass WIMP's : original methods for energy and fiducial volume calibration and background rejection are described and preliminary results obtained with a low radioactivity prototype operated in Laboratoire Souterrain de Modane ("Frejus" lab) are presented. Typical expected sensitivities in cross section for low mass WIMP's are also shown, and other applications briefly discussed.
  • Conceptual Design of the International Axion Observatory (IAXO) (1401.3233)

    E. Armengaud, F. T. Avignone, M. Betz, P. Brax, P. Brun, G. Cantatore, J. M. Carmona, G. P. Carosi, F. Caspers, S. Caspi, S. A. Cetin, D. Chelouche, F. E. Christensen, A. Dael, T. Dafni, M. Davenport, A.V. Derbin, K. Desch, A. Diago, B. Döbrich, I. Dratchnev, A. Dudarev, C. Eleftheriadis, G. Fanourakis, E. Ferrer-Ribas, J. Galán, J. A. García, J. G. Garza, T. Geralis, B. Gimeno, I. Giomataris, S. Gninenko, H. Gómez, D. González-Díaz, E. Guendelman, C. J. Hailey, T. Hiramatsu, D. H. H. Hoffmann, D. Horns, F. J. Iguaz, I. G. Irastorza, J. Isern, K. Imai, A. C. Jakobsen, J. Jaeckel, K. Jakovčić, J. Kaminski, M. Kawasaki, M. Karuza, M. Krčmar, K. Kousouris, C. Krieger, B. Lakić, O. Limousin, A. Lindner, A. Liolios, G. Luzón, S. Matsuki, V. N. Muratova, C. Nones, I. Ortega, T. Papaevangelou, M. J. Pivovaroff, G. Raffelt, J. Redondo, A. Ringwald, S. Russenschuck, J. Ruz, K. Saikawa, I. Savvidis, T. Sekiguchi, Y. K. Semertzidis, I. Shilon, P. Sikivie, H. Silva, H. ten Kate, A. Tomas, S. Troitsky, T. Vafeiadis, K. van Bibber, P. Vedrine, J. A. Villar, J. K. Vogel, L. Walckiers, A. Weltman, W. Wester, S. C. Yildiz, K. Zioutas
    Jan. 14, 2014 hep-ex, physics.ins-det
    ... ... ... ... ... ...
    The International Axion Observatory (IAXO) will be a forth generation axion helioscope. As its primary physics goal, IAXO will look for axions or axion-like particles (ALPs) originating in the Sun via the Primakoff conversion of the solar plasma photons. In terms of signal-to-noise ratio, IAXO will be about 4-5 orders of magnitude more sensitive than CAST, currently the most powerful axion helioscope, reaching sensitivity to axion-photon couplings down to a few $\times 10^{-12}$ GeV$^{-1}$ and thus probing a large fraction of the currently unexplored axion and ALP parameter space. IAXO will also be sensitive to solar axions produced by mechanisms mediated by the axion-electron coupling $g_{ae}$ with sensitivity $-$for the first time$-$ to values of $g_{ae}$ not previously excluded by astrophysics. With several other possible physics cases, IAXO has the potential to serve as a multi-purpose facility for generic axion and ALP research in the next decade. In this paper we present the conceptual design of IAXO, which follows the layout of an enhanced axion helioscope, based on a purpose-built 20m-long 8-coils toroidal superconducting magnet. All the eight 60cm-diameter magnet bores are equipped with focusing x-ray optics, able to focus the signal photons into $\sim 0.2$ cm$^2$ spots that are imaged by ultra-low-background Micromegas x-ray detectors. The magnet is built into a structure with elevation and azimuth drives that will allow for solar tracking for $\sim$12 h each day.
  • X-ray detection with Micromegas with background levels below 10$^{-6}$ keV$^{-1}$cm$^{-2}$s$^{-1}$ (1312.4282)

    S. Aune, F. Aznar, D. Calvet, T. Dafni, A. Diago, F. Druillole, G. Fanourakis, E. Ferrer-Ribas, J. Galán, J.A. García, A. Gardikiotis, J.G. Garza, T. Geralis, I. Giomataris, H. Gómez, D. González-Díaz, D.C. Herrera, F.J. Iguaz, I.G. Irastorza, D. Jourde, G. Luzón, H. Mirallas, J.P. Mols, T. Papaevangelou, A. Rodríguez, L. Seguí, A.Tomás, T. Vafeiadis, S.C. Yildiz
    Dec. 16, 2013 physics.ins-det
    Micromegas detectors are an optimum technological choice for the detection of low energy x-rays. The low background techniques applied to these detectors yielded remarkable background reductions over the years, being the CAST experiment beneficiary of these developments. In this document we report on the latest upgrades towards further background reductions and better understanding of the detectors' response. The upgrades encompass the readout electronics, a new detector design and the implementation of a more efficient cosmic muon veto system. Background levels below 10$^{-6}$keV$^{-1}$cm$^{-2}$s$^{-1}$ have been obtained at sea level for the first time, demonstrating the feasibility of the expectations posed by IAXO, the next generation axion helioscope. Some results obtained with a set of measurements conducted in the x-ray beam of the CAST Detector Laboratory will be also presented and discussed.
  • Low background x-ray detection with Micromegas for axion research (1310.3391)

    S. Aune, J.F. Castel, T. Dafni, M. Davenport, G. Fanourakis, E. Ferrer-Ribas, J. Galan, J.A. Garcia, A. Gardikiotis, T. Geralis, I. Giomataris, H. Gomez, J.G. Garza, D.C. Herrera, F.J. Iguaz, I.G. Irastorza, D. Jourde, G. Luzon, J.P. Mols, T. Papaevangelou, A. Rodriguez, J. Ruz, L. Segui, A. Tomas, T. Vafeiadis, S.C. Yildiz
    Oct. 12, 2013 hep-ex, physics.ins-det
    ... ... ... ... ... ...
    Axion helioscopes aim at the detection of solar axions through their conversion into x-rays in laboratory magnetic fields. The use of low background x-ray detectors is an essential component contributing to the sensitivity of these searches. Here we review the recent advances on Micromegas detectors used in the CERN Axion Solar Telescope (CAST) and proposed for the future International Axion Observatory (IAXO). The most recent Micromegas setups in CAST have achieved background levels of 1.5$\times10^{-6}$\ckcs, a factor of more than 100 lower than the ones obtained by the first generation of CAST detectors. This improvement is due to the development of active and passive shielding techniques, offline discrimination techniques allowed by highly granular readout patterns, as well as the use of radiopure detector components. The status of the intensive R&D to reduce the background levels will be described, including the operation of replica detectors in test benches and the detailed Geant4 simulation of the detector setup and the detector response, which has allowed the progressive understanding of background origins. The best levels currently achieved in a test setup operating in the Canfranc Underground Laboratory (LSC) are as low as $\sim10^{-7}$\ckcs, showing the good prospects of this technology for application in the future IAXO.
  • Piggyback resistive Micromegas (1310.1242)

    D.Attié, A. Chaus, D. Durand, D. Deforges E. Ferrer-Ribas, J. Galán, Y. Giomataris, A. Gongadze, F. J. Iguaz, F. Jeanneau, R. de Oliveira, T. Papaevangelou, A. Peyaud, A. Teixeira
    Oct. 4, 2013 physics.ins-det
    ... ... ... ... ... ...
    Piggyback Micromegas consists in a novel readout architecture where the anode element is made of a resistive layer on a ceramic substrate. The resistive layer is deposited on the thin ceramic substrate by an industrial process which provides large dynamic range of resistivity (10$^6$ to 10$^{10}$\,M$\Omega$/square). The particularity of this new structure is that the active part is entirely dissociated from the read-out element. This gives a large flexibility on the design of the anode structure and the readout scheme. Without significant loss, signals are transmitted by capacitive coupling to the read-out pads. The detector provides high gas gain, good energy resolution and the resistive layer assures spark protection for the electronics. This assembly could be combined with modern pixel array electronic ASICs. First tests with different Piggyback detectors and configurations will be presented. This structure is adequate for cost effective fabrication and low outgassing detectors. It was designed to perform in sealed mode and its long term stability has been extensively studied. In addition perspectives on the future developments will be evoked.
  • CAST constraints on the axion-electron coupling (1302.6283)

    K. Barth, A. Belov, B. Beltran, H. Brauninger, J. M. Carmona, J.I. Collar, T. Dafni, M. Davenport, L. Di Lella, C. Eleftheriadis, J. Englhauser, G. Fanourakis, E. Ferrer Ribas, H. Fischer, J. Franz, P. Friedrich, J. Galan, J. A. Garcia, T. Geralis, I. Giomataris, S. Gninenko, H. Gomez, M. D. Hassinoff, F. H. Heinsius, D. H. H. Hoffmann, I.G. Irastorza, J. Jacoby, K. Jakovcic, D. Kang, K. Konigsmann, R. Kotthaus, K. Kousouris, M. Krcmar, M. Kuster, B. Lakic, A. Liolios, A. Ljubicic, G. Lutz, G. Luzon, D.W. Miller, T. Papaevangelou, M.J. Pivovaroff, G. Raffelt, J. Redondo, H. Riege, A. Rodriguez, J. Ruz, I. Savvidis, Y. Semertzidis, L. Stewart, K. Van Bibber, J.D. Vieira, J.A. Villar, J.K. Vogel, L. Walckiers, K. Zioutas
    April 19, 2013 hep-ph, astro-ph.SR
    In non-hadronic axion models, which have a tree-level axion-electron interaction, the Sun produces a strong axion flux by bremsstrahlung, Compton scattering, and axio-recombination, the "BCA processes." Based on a new calculation of this flux, including for the first time axio-recombination, we derive limits on the axion-electron Yukawa coupling g_ae and axion-photon interaction strength g_ag using the CAST phase-I data (vacuum phase). For m_a < 10 meV/c2 we find g_ag x g_ae< 8.1 x 10^-23 GeV^-1 at 95% CL. We stress that a next-generation axion helioscope such as the proposed IAXO could push this sensitivity into a range beyond stellar energy-loss limits and test the hypothesis that white-dwarf cooling is dominated by axion emission.
  • Ageing studies of resistive Micromegas detectors for the HL-LHC (1304.2053)

    J. Galan, D. Attie, E. Ferrer-Ribas, A. Giganon, I. Giomataris, S. Herlant, F. Jeanneau, A. Peyaud, Ph. Schune, T. Alexopoulos, M. Byszewski, G. Iakovidis, P. Iengo, K. Ntekas, S. Leontsinis, R. de Oliveira, Y. Tsipolitis, J. Wotschack
    April 7, 2013 hep-ex, physics.ins-det
    ... ... ... ... ... ...
    Resistive-anode Micromegas detectors are in development since several years, in an effort to solve the problem of sparks when working in high flux and high radiations environment like in the HL-LHC (ten times the luminosity of the LHC). They have been chosen as one of the technologies that will be part of the ATLAS New Small Wheel project (forward muon system). An ageing study is mandatory to assess their capabilities to handle the HL-LHC environment on a long-term period. A prototype has been exposed to several types of irradiations (X-rays, cold neutrons, 60 Co gammas) up to an equivalent HL-LHC time of more than five years without showing any degradation of the performances in terms of gain and energy resolution. Beam test studies took place in October 2012 to assess the tracking performances (efficiency, spatial resolution,...). Results of ageing studies and beam test performances are reported in this paper.
  • Characterization and simulation of resistive-MPGDs with resistive strip and layer topologies (1304.2057)

    J. Galan, D. Attie, A. Chaus, P. Colas, A. Delbart, E. Ferrer-Ribas, I. Giomataris, F.J. Iguaz, A. Gongadze, T. Papaevangelou, A. Peyaud
    April 7, 2013 physics.comp-ph, physics.ins-det
    ... ... ... ... ... ...
    The use of resistive technologies to MPGD detectors is taking advantage for many new applications, including high rate and energetic particle flux scenarios. The recent use of these technologies in large area detectors makes necessary to understand and characterize the response of this type of detectors in order to optimize or constrain the parameters used in its production, material resistivity, strip width, or layer thickness. The values to be chosen will depend on the environmental conditions in which the detector will be placed, and the requirements in time resolution and gain, improving the detector performance for each given application. We present two different methods to calculate the propagation of charge diffusion through different resistive topologies; one is based on a FEM of solving the telegraph equation in our particular strip detector scheme, the other is based on a semi-analytical approach of charge diffusion and is used to determine the charge evolution in a resistive layer.
  • IAXO - The International Axion Observatory (1302.3273)

    J. K. Vogel, F. T. Avignone, G. Cantatore, J. M. Carmona, S. Caspi, S. A. Cetin, F. E. Christensen, A. Dael, T. Dafni, M. Davenport, A. V. Derbin, K. Desch, A. Diago, A. Dudarev, C. Eleftheriadis, G. Fanourakis, E. Ferrer-Ribas, J. Galan, J. A. Garcia, J. G. Garza, T. Geralis, B. Gimeno, I. Giomataris, S. Gninenko, H. Gomez, C. J. Hailey, T. Hiramatsu, D. H. H. Hoffmann, F. J. Iguaz, I. G. Irastorza, J. Isern, J. Jaeckel, K. Jakovcic, J. Kaminski, M. Kawasaki, M. Krcmar, C. Krieger, B. Lakic, A. Lindner, A. Liolios, G. Luzon, I. Ortega, T. Papaevangelou, M. J. Pivovaroff, G. Raffelt, J. Redondo, A. Ringwald, S. Russenschuck, J. Ruz, K. Saikawa, I. Savvidis, T. Sekiguchi, I. Shilon, H. Silva, H. H. J. ten Kate, A. Tomas, S. Troitsky, K. van Bibber, P. Vedrine, J. A. Villar, L. Walckiers, W. Wester, S. C. Yildiz, K. Zioutas
    Feb. 13, 2013 hep-ex, physics.ins-det
    ... ... ... ... ... ...
    The International Axion Observatory (IAXO) is a next generation axion helioscope aiming at a sensitivity to the axion-photon coupling of a few 10^{-12} GeV^{-1}, i.e. 1-1.5 orders of magnitude beyond sensitivities achieved by the currently most sensitive axion helioscope, the CERN Axion Solar Telescope (CAST). Crucial factors in improving the sensitivity for IAXO are the increase of the magnetic field volume together with the extensive use of x-ray focusing optics and low background detectors, innovations already successfully tested at CAST. Electron-coupled axions invoked to explain the white dwarf cooling, relic axions, and a large variety of more generic axion-like particles (ALPs) along with other novel excitations at the low-energy frontier of elementary particle physics could provide additional physics motivation for IAXO.
  • A Piggyback resistive Micromegas (1208.6525)

    D. Attie, A. Chaus, P. Colas, E. Ferrer, J. Galan, I. Giomatari, F.J. Iguaz, A. Gongadze, R. De Oliveira, T. Papaevangelou, A. Peyaud
    Feb. 5, 2013 physics.ins-det
    ... ... ... ... ... ...
    A novel read-out architecture has been developed for the Micromegas detector. The anode element is made of a resistive layer on a ceramic substrate. The detector part is entirely separated from the read-out element. Without significant loss, signals are transmitted by capacitive coupling to the read-out pads. The detector provides high gas gain, good energy resolution and the resistive layer assures spark protection to the electronics. This assembly could be combined with modern pixel array electronic ASICs. This readout organization is free on how the pixels are designed, arranged and connected. We present first results taken with a MediPix read-out chip.
  • An ageing study of resistive micromegas for the HL-LHC environment (1301.7648)

    J. Galán, D. Attié, E. Ferrer-Ribas, A. Giganon, I. Giomataris, S. Herlant, F. Jeanneau, A. Peyaud, Ph. Schune, T. Alexopoulos, M. Byszewski, G. Iakovidis, P. Iengo, K. Ntekas, S. Leontsinis, R. de Oliveira, Y. Tsipolitis, J. Wotschack
    Jan. 31, 2013 hep-ex, physics.ins-det, physics.acc-ph
    ... ... ... ... ... ...
    Resistive-anode micromegas detectors are in development since several years, in an effort to solve the problem of sparks when working at high flux and high ionizing radiation like in the HL-LHC (up to ten times the luminosity of the LHC). They have been chosen as one of the technologies that will be part of the ATLAS New Small Wheel project (forward muon system). An ageing study is mandatory to assess their capabilities to handle the HL-LHC environment on a long-term period. A prototype has been exposed to several types of irradiation (X-rays, cold neutrons, $^{60}$Co gammas and alphas) above the equivalent charge produced at the detector in five HL-LHC running years without showing any degradation of the performances in terms of gain and energy resolution. This study has been completed with the characterization of the tracking performances in terms of efficiency and spatial resolution, verifying the compatibility of results obtained with both resistive micromegas detectors, irradiated and non-irradiated one.